advertisement
2.3.
CS-A12HKD CU-A12HKD
N
G
T
I
E
A
G
H
I
N
O
L
Item
Performance Test Condition
C
O Capacity
EER
Noise Level
Capacity
Cop
Noise Level
Moisture Removal
Lo
Me
Air Volume
Hi
SHi
Refrigerant Control Device
Refrigerant Oil (Charged)
Refrigerant (Charged) R22
Dimension
Height
Width
Depth
Net Weight
Pipe Diameter
Gas
Liquid
Height Difference
Pipe Length Range
Additional Gas Amount
Refrigeration Charge Less
Drain Hose
Compressor
Fan
Inner diameter
Length
Type
Motor Type
Rated Output
Type
Material
Motor Type
Input power
Output power
Fan Speed
Lo (Cool / Heat)
Me (Cool / Heat)
Hi (Cool / Heat)
SHi (Cool / Heat) m
3 m
3
Unit
/m (ft
3
/m (ft
3
/m)
/m) cm
3 kg (oz) mm (inch) mm (inch) mm (inch) kg (lbs) mm (inch) mm (inch) m (ft) m (ft) g/m (oz/ft) m (ft) mm mm kW
BTU/h kcal/h
W/W
BTU/hW dB (A)
Power level dB kW
BTU/h kcal/h
W/W
BTU/hW dB (A)
Power level dB l/h
(pt/h) m
3
/m (ft
3
/m) m
3
/m (ft
3
/m)
W
W
W rpm rpm rpm rpm
Indoor unit
High: 39 Low: 29
High: 52
NEW JIS
3.52 - 3.54
12000 - 12100
3030 - 3040
3.26 - 3.16
11.1 - 10.8
4.00 - 4.05
13640 - 13810
3440 - 3480
3.67 - 3.62
12.5 - 12.3
High: 40 Low: 29
High: 53
2.0
4.2
Cooling; 6.1 (220)
Heating; 6.5 (230)
Cooling; 8.5 (300)
Heating; 8.5 (300)
Cooling; 9.9 (350)
Heating; 10.0 (350)
Cooling; 10.1 (360)
Outdoor unit
High: 48 - 49
High: 63 - 64
High: 48 - 49
High: 64 - 65
—
—
Cooling;
32.5 (1150) - 33.0 (1160)
—
—
—
—
280 (11 - 1/32)
799 (31 - 15/32)
183 (7 - 7/32)
9 (20)
16
650
—
12.70 (1/2”)
6.35 (1/4”)
5 (16.4)
3 (9.8) ~ 15 (49.2)
20 (0.2)
7.5 (24.6)
Capillary Tube
ATMOS NM56M or
SUNISO 4GDID (350cm
3
)
1.01 (35.7)
540 (21 - 9/32)
780 (30 - 23/32)
289 (11 - 13/32)
34 (75)
—
—
Rotary (1 cylinder) rolling piston type
Induction (2-poles) —
—
Cross-flow Fan
ASG20K1
Induction (4-poles)
42 - 47
15
800 / 860
1120 / 1120
1300 / 1320
1320 / —
950
Propeller Fan
PP Resin
Induction (6-poles)
64 - 73
31
—
—
845 - 860 / —
—
9
Heat Exchanger
Air Filter Type
Item
Fin material
Fin Type
Row
× Stage × FPI
Size (W
× H × L)
Material
Style
Unit
mm (inch)
Indoor unit
Aluminium (Pre Coat)
Slit Fin
2
× 15 × 21
610
× 315 × 25.4
Polypropelene
One-touch
Outdoor unit
Aluminium (Blue Coat)
Corrugate Fin
2
× 24 × 17
36.38
× 504 × 713:684
—
—
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Power Source (Phase, Voltage, Cycle)
Input power
Item
Cooling
Heating
Hz
W
W
A
Unit
ø Single
V 220
50
1.08
1.09
20 Starting Current
Running Current Cooling
Heating
A
A
Maximum Current
Cooling
A
%
Power Factor
Heating %
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
5.1
5.2
6.0
96
95
Power Cord
Thermostat
Protection Device
Number of core
Length m (ft)
3 (1.5mm)
2 (6)
—
—
Note:
• Specification are subjected to change without prior notice for further improvement.
Single
230
50
1.12
1.12
20
5.1
5.1
6.0
95
95
—
Overload Protector
10
3 Features
• E-ion Air Purifying System with Patrol Sensor
- Active e-ions are released to catch dust particles and bring them back the large positively charged filter
- Patrol Sensor color changes to indicate the dirt level in the air
• Long Installation Piping
- CS/CU-A7HK, CS/CU-A9HK, long piping up to 10 meter
- CS/CU-A12HK, long piping up to 15 meter
• Easy to use remote control
• Quality Improvement
- Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect Compressor
- Noise prevention during soft dry operation
- Blue Coated Condenser for high resistance to corrosion
• Operation Improvement
- Quiet mode to reduce the indoor unit operating sound
- Powerful mode to reach the desired room temperature quickly
- 24-hour timer setting
11
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 8 Order No. MAC
- 5 2.1. CS-A7HKD CU-A7HKD
- 7 2.2. CS-A9HKD CU-A9HKD
- 9 2.3. CS-A12HKD CU-A12HKD
- 12 4.1. Indoor Unit
- 12 4.2. Outdoor Unit
- 12 4.3. Outdoor Unit
- 13 5.1. Indoor Unit & Remote Control
- 14 5.2. Outdoor Unit
- 16 A9HKD
- 17 7.2. CS-A12HKD CU-A12HKD
- 18 A9HKD
- 19 8.2. CS-A12HKD CU-A12HKD
- 21 10.1. Main Printed Circuit Board
- 22 10.2. Power Printed Circuit Board
- 23 10.3. Indicator Printed Circuit Board
- 23 10.4. Patrol Printed Circuit Board
- 24 11.1. Select The Best Location
- 24 11.2. Indoor/Outdoor Unit Installation Diagram
- 25 11.3. Indoor Unit
- 28 11.4. Outdoor Unit
- 31 12.1. Heating Operation
- 32 12.2. Cooling Operation
- 33 12.3. Soft Dry Operation
- 34 12.4. Automatic Operation
- 35 12.5. Indoor Fan Speed Control
- 37 12.6. Outdoor Fan Speed Control
- 37 12.7. Vertical Airflow Direction Control
- 38 12.8. Horizontal Airflow Direction Control
- 38 12.9. Powerful Operation
- 39 12.10. Quiet Operation
- 41 12.11. Timer Control
- 41 12.12. Random Auto Restart Control
- 41 12.13. Remote Control Signal Receiving Sound
- 42 12.14. Patrol Operation
- 45 12.15. e-ion Operation
- 47 13.1. Restart Control (Time Delay Safety Control)
- 47 13.2. 7 Minutes Time Save Control
- 47 13.3. 60 Seconds Forced Operation
- 47 13.4. Starting current Control
- 47 13.5. Freeze Preventive Control
- 48 Control
- 48 13.7. Dew Prevention control
- 48 13.8. 30 Minutes Time Save Control
- 49 13.9. Compressor Overload Protection Control
- 49 13.10. 4-Way Valve Control
- 49 13.11. Outdoor Fan Motor Control
- 49 13.12. Hot Start Control
- 49 13.13. Cold Draft Prevention Control
- 50 13.14. Deice Control
- 52 14.1. Auto OFF/ON Button
- 52 14.2. Select Remote Control Transmission Code
- 53 14.3. Remote Control Button
- 54 15.1. Refrigeration cycle system
- 56 Board Removal Procedures
- 58 Removal Procedures
- 60 17.1. Thermostat Characteristics
- 61 17.2. Operation Characteristics
- 73 18.1. Indoor Unit
- 75 18.2. Outdoor Unit