Doc IT ALL® & Doc IT IN®
Installation and Operation Manual
OPERATION
Initial Preparation
Once the system is properly installed and electrically connected, it is ready for initial startup. Make sure the switch circuit breaker (1) is ON.
When first shipped, the unit will come with a filter bag pre-installed in the vacuum.
Before operating, verify that this is the case by opening the cover on the bottom
1 ON/OFF
Floor Brush
Reset of the unit. To do so, press buttons on both sides of the cabinet to release door.
Lower door to floor and ensure bag is
Motor Drive
Reset attached. (See diagram)
Be sure that the filter dust collection bag is in place in the vacuum. Air exhausts at the bottom of the cabinet.
Caution: WARRANTY VOID IF UNIT IS USED WITHOUT COLLECTION BAG.
NOTE: Bag comes with dust cap to prevent a full bag from blowing back dust during removal.
To use, simply unfold, peel and stick dust cap over bag opening.
Load new bag with arrows pointing to rear of bag chamber.
Hook over Fitting at Rear and push cardboard collar firmly up to seal.
PN: MOD-10102
Canavac Systems Inc © 2013
19
Rev.3.0 www.canavac.com
Doc IT ALL® & Doc IT IN®
Installation and Operation Manual
Hose Handle Controls
Push and hold the OUT button located on the handle keypad on the Hand Grip and the hose will move upward and out of the hose compartment.
• When a sufficient length of hose has been extended so that there is room to vacuum, release the button, remove the rubber cap and connect the vacuum attachments.
• When using an approved Power head, connect it securely to the Telescopic Wand and then connect the two prong connector in the receptacle below the Hand Grip. If you are using nonelectric attachments, be sure they are securely attached to the Hand Grip or Telescopic Wand.
• To start the vacuum only, push the VAC Button. To start the vacuum and the Power head, push the VAC Button again within 3 seconds. To turn off the vacuum and the Power head, push the VAC Button one final time.
• While using the system, you will be able to extend or retract the hose when necessary. When vacuuming is finished, stop the vacuum by pushing the VAC Button on the key pad. Retract the hose by pushing the IN Button. The hose will retract into the wall cavity.
• Place the rubber cap on the end of the handle to permit vacuum at other central vacuum inlets
(such as Vacpan, if installed).
Notes:
• If for any reason it becomes difficult to fully retract the Hose into the Cabinet, refer to the troubleshooting section of this manual.
• When Hose is fully retracted, the IN button will be disabled to prevent damage to the hose.
Similarly when the hose is fully extended, the OUT button will not function to prevent damage to the hose.
• To maximize Vacuum motor life, the software in the system control board prevents the user from rapidly turning the vacuum from OFF to ON and back OFF again. Be patient when operating this function.
• This appliance is equipped with an electronic vacuum motor starting feature to improve system reliability. A short duration buzz when the motor is first started (wthin 1-2 seconds) is normal for this product.
ON/OFF
Button for
VAC and/or
Power Head.
PN: MOD-10102
Canavac Systems Inc © 2013
20
Rev.3.0 www.canavac.com
Doc IT ALL® & Doc IT IN®
Installation and Operation Manual
Bag Replacement
Open vacuum compartment by pressing side buttons located at top of door, inward, until door releases.
To install a new bag, place cardboard collar in top back of vacuum cabinet as shown and tilt upward while applying pressure to the underside of the cardboard collar.
Rubber seal should be fully engaged with pipe fitting in cabinet. Gently pull collar down to check engagement.
Expand pleats of vacuum bag so that bag fills bag space in cabinet.
Close cover until both latches engage in door.
PN: MOD-10102
Canavac Systems Inc © 2013