General specifications for system features
This table lists general specifications for system features for the 7000 Series platform.
Item
Transceiver modules hot swap
Power supply hot swap
Jumbo frames
Virtual Clustered Multiprocessing
(vCMP
™
)
™
Specification
Support for hot swap of SFP, SFP+, and QSFP+ transceiver modules
Support for hot swap of the power supplies
Support for maximum Ethernet frame size of 9216 bytes and MTU of 9128 bytes
Supports provisioning and managing multiple, hosted instances of the BIG-IP software on a single hardware device
Important: Specifications are subject to change without notification.
Platform hardware specifications
This table lists hardware specifications for the BIG-IP
®
7000 Series platform.
Item
Dimensions
Weight
Processor
Communication interfaces
Specification
H: 3.45 inches (8.76 cm) x W: 17.3 inches (43.94 cm) x D: 21.4 inches (54.36 cm)
(per unit) 2U industry standard rack-mount chassis
40 pounds (18.14 kg) with one power supply, two hard drives, and bezel installed (per unit)
43 pounds (19.50 kg) with two power supplies, two hard drives, and bezel installed
(per unit)
42.4 pounds (19.23 kg) with two power supplies, one solid-state drive, and bezel installed (per unit)
42.6 pounds (19.32 kg) with two power supplies, two solid-state drives, and bezel installed (per unit)
• Front mount rack brackets add 2 pounds (0.9 kg).
• Quick install rail kit adds 5.5 pounds (2.27 kg).
1 x Quad-Core Intel
®
Xeon
® processor
4 x 1GbE Cu RJ45 ports
8 x 10GbE SFP+ ports
1 x 10/100/1000 Ethernet Management port
1 x RJ45 console port
1 x RJ45 failover port
2 x USB 2.0 interfaces
Platform Specifications
Item
Storage drive capacity
Specification
2 x 1 TB hard disk drive (HDD)
1 x 400 GB solid-state drive (SSD) (7050 platform only)
2 x 400 GB solid-state drive (SSD) (7055 platform only)
RAM
AC power input requirements
32 GB
2 x 400 W 90-240VAC, 50-60hz
DC power supply 1-2 x 300 W DC
Operating range: 40 to 72 VDC
Important: Specifications are subject to change without notification.
Important: F5
®
Networks only provides support for F5-branded or F5-provided optical modules.
Platform environmental operating specifications
This table lists platform environmental operating specifications.
Item
Operational relative humidity
Non-operational temperature
Specification
Operational temperature 32 to 104°F (0 to 40°C)
GR-63-CORE table 4-4
5% to 85% (40°C) non-condensing
5% to 90% (40°C) non-condensing for a maximum of
96 hours
-40 to 158°F (-40 to 70°C)
Non-operational relative humidity
5 to 95% (40°C) non-condensing
Important: Specifications are subject to change without notification.
Platform power specifications - 7000s/7200v
This table lists power specifications for the BIG-IP
®
7000s/7200v platform.
Item Single Power Supply
Typical power draw (AC power; 50% load; temp
25°C)
110VAC input: 200W
220VAC input: 195W
Typical power draw (DC power; 50% load; temp
25°C)
48VDC input: 205W
Maximum power draw (AC power) 90VAC input: 290W
Dual Power Supply
110VAC input: 205W
220VAC input: 200W
48VDC input: 210W
90VAC input: 295W
50
Platform Guide: 7000 Series
Item
Maximum power draw (DC power)
Typical heat generated (AC power)
Typical heat generated (DC power)
Maximum heat generated (AC power)
Maximum heat generated (DC power)
Single Power Supply
40VDC input: 310W
110VAC input: 683
BTU/hour
220VAC input: 666
BTU/hour
48VDC input: 700
BTU/hour
90VAC input: 990
BTU/hour
40VDC input: 1058
BTU/hour
Dual Power Supply
40VDC input: 315W
110VAC input: 700
BTU/hour
220VAC input: 683
BTU/hour
48VDC input: 717
BTU/hour
90VAC input: 1007
BTU/hour
40VDC input: 1075
BTU/hour
Important: Specifications are subject to change without notification.
Platform power specifications - 7050 Series
This table lists power specifications for the 7050 Series platform.
Item Single Power Supply
Typical power draw (AC power; 50% load; temp
25°C)
110VAC input: 210W
220VAC input: 200W
Typical power draw (DC power; 50% load; temp
25°C)
48VDC input: 215W
Maximum power draw (AC power)
Maximum power draw (DC power)
Typical heat generated (AC power)
90VAC input: 300W
40VDC input: 320W
110VAC input: 715
BTU/hour
220VAC input: 680
BTU/hour
Typical heat generated (DC power)
Maximum heat generated (AC power)
Maximum heat generated (DC power)
48VDC input: 735
BTU/hour
90VAC input: 1025
BTU/hour
40VDC input: 1090
BTU/hour
Dual Power Supply
110VAC input: 215W
220VAC input: 210W
48VDC input: 220W
90VAC input: 305W
40VDC input: 325W
110VAC input: 735
BTU/hour
220VAC input: 715
BTU/hour
48VDC input: 750
BTU/hour
90VAC input: 1040
BTU/hour
40VDC input: 1075
BTU/hour
Important: Specifications are subject to change without notification.
51
Platform Specifications
Safety requirements
This equipment complies with these requirements of the Low Voltage Directive 2006/95/EC:
EC Type Examination Certificates: Master Contract 252302
CB Scheme
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
IEC 60950-1:2005, A1:2009
CSA 60950-1-07, Including Amendment 1:2011
ANSI/UL 60950-1-2011
Important: Specifications are subject to change without notification.
EMC requirements
USA--FCC Class A, Canada--Industry Canada Class A
This equipment complies with Subpart B of Part 15 of FCC Rules for Class A digital devices, Industry
Canada ICES-003, Issue 5. Operation is subject to these two conditions:
1.
This equipment may not cause harmful interference.
2.
This device must accept any interference received, including interference that may cause undesired operation.
Important: Specifications are subject to change without notification.
Acoustic, airflow, and altitude specifications
This table lists acoustic levels, airflow movement, and operational altitude specifications for the BIG-IP
®
7000 Series platform.
Specification type
Acoustic
1
Detail
Front
Back
Left
Right
Top
Units
dBA dBA dBA dBA dBA
Value
67
78
66
69
69
1
Acoustic measurements taken at 0.6 meter with two power supplies operational and fans at normal operating conditions
(27°C and 80% duty cycle). Maximum acoustic noise is 83dBA at 100% duty cycle. Measurements recorded in Decibels
A-weighting.
52
Platform Guide: 7000 Series
Specification type
Altitude
2
Detail
Open air
Units
Operational
Non-operational
Feet
(Meters)
Feet
(Meters)
CFM
Value
6,000 (1,829)
40,000
(12,192)
135.7
Airflow
3
Important: Specifications are subject to change without notification.
2
3
Per BELCORE GR-63-CORE, section 4.1.3: This unit is functional when installed at elevations between 60m (197 feet) below sea level and 1800m (6000 feet) above sea level at the aisle ambient temperatures of 40°C.