Centurion R3 is a reliable and versatile swing gate operator designed to automate residential and light industrial gates. It features a maintenance-free, lead-acid battery and a solar panel for backup power, ensuring uninterrupted operation even during power outages. The R3's independent motor drive units provide self-locking security, preventing forced entry. Advanced lightning protection circuitry ensures reliable operation in stormy conditions. With its automatic closing, pedestrian keyswitch, and adjustable security light timer, the R3 offers enhanced convenience and security.

advertisement

Intercom Pushbutton. Centurion R3, R5 | Manualzz

If the gate is opening with the automatic closing facility selected, and the transmitter is then pressed, the gate will stop, but will close automatically after the auto-close delay time.

Intercom Push button (Optional)

Press to open gate

A visitor outside the gate requests entrance Gate opened from intercom pushbutton inside house

Most automatic gate installations are fitted with an intercom which provides for communication between the house and the gate.

The intercom handset is usually provided with a GATE or DOOR RELEASE pushbutton which, when pressed, sends a signal to the gate controller to open the gate.

The sequence of operation of this pushbutton is identical to the operation when using the radio transmitter as described above.

REVERSING MODE

The system offers an alternative mode of operation to the above. Referred to as reversing mode, if the transmitter is pressed while the gate is moving, the gate will automatically reverse direction. This mode offers greater security than STANDARD mode as the gate can never be left in a midway position.

CONDOMINIUM MODE

The system can be set for CONDOMINIUM operation. This facility is designed for greater safety and security, in applications where there will be a number of users, such as the entrance to a townhouse estate, factory or office park.

In CONDOMINIUM mode the gate is opened by pressing the pushbutton on the remote transmitter or intercom. If the system is re-triggered while the gate is opening, the signal is ignored and the gate will continue to open. The gate closes automatically as per the AUTO-CLOSE facility described later in this user guide. In CONDOMINIUM mode the AUTO-CLOSE cannot be overridden. If the remote transmitter or intercom pushbutton is pressed while the gate is closing the gate will immediately reopen.

The gate cannot be stopped in a midway position and will therefore always close.

If the gate is triggered while the gate is in the open position, the AUTO-CLOSE timer is reset.

NOTE: It is highly recommended that a protection beam be used in conjunction with this facility to prevent the AUTO-CLOSE from closing the gate onto a vehicle passing through.

PIRAC (PASSIVE INFRA RED AUTO-CLOSE)

This facility is an extension of the CONDOMINIUM facility described above. It is designed for applications