SPECIFICATION
CP84ER5V01 power supply unit)
DC Current draw (Max)
CP84ER5V01 power supply unit)
Maximum solenoid lock current draw
Output shaft rotational speed
Maximum output torque
Maximum number of operations per day (Average)
Maximum number of continuous operations
Typical time to open/close a gate
(For standard pedestal in recommended position)
R3
220V AC ±10% 50Hz
120mA
15A
2A
3.5 rpm
140Nm
100*
20
10 seconds
No. of operations on a 7A/H battery (should the mains power fail)
Limit switches
±20
Sealed optical counter with origin switch
Collision sensitivity
Electronic adjustable
Temperature range
Housing protection
Control card (single or double motor)
Corrosion protection (baseplate and arms)
IP55
CP75
Zinc electro galvanising
Maximum gate length & mass:
Gate Length:
Max. Allowable Leaf Mass:
Max. wind speeds for which the operator
For a 1.8m high gate, 25% coverage:
For a 1.8m high gate, 100% coverage:
1,5m
1000kg
2,0m
550kg
2,5m#
350kg
3,0m#
250kg
3,5m#
180kg
110km/h
55km/h
82km/h
41km/h
66km/h
33km/h
55km/h
27km/h
47km/h
23km/h
*Subject to system power supply. Standard battery driven system with 7A/H battery is limited to 20 operations per day.
# For pedestal mount installations where the gate exceeds 3m, and wall mount installations where the gate exceeds 2,5m, it is recommended that an electric lock be fitted.
† This applies only to STANDARD pedestal mount installations installed according to the RECOMMENDED positions.
Page 18