ADVANCED FEATURES . INSTEON ApplianceLinc 2456S


Add to my manuals
12 Pages

advertisement

ADVANCED FEATURES . INSTEON ApplianceLinc 2456S | Manualzz

ApplianceLinc Owner’s Manual

ADVANCED FEATURES

Enabling/Disabling Load Sensing

Load Sensing allows you to manually turn on the load plugged into ApplianceLinc by using the switch on the load itself, without sending a command from an INSTEON or X10 controller. When the load is in the off state (with Load Sensing enabled), ApplianceLinc will “sense” that you are trying to turn it on with its built-in switch. When ApplianceLinc senses this, it will turn on the load automatically.

CAUTION: With Load Sensing, some lamps have been known to turn on ApplianceLinc after you have turned it off. Please use this feature with caution.

By default, Load Sensing is disabled on product versions 2.0 or higher and enabled on product versions

1.4 or higher.

Enable Load Sensing

1) Press & hold the Set button on ApplianceLinc for 3 seconds

The ApplianceLinc Status LED will begin blinking

2) Triple-tap the Set button on ApplianceLinc

The ApplianceLinc Status LED will stop blinking and turn on solid

3) Test that Load Sensing has been enabled by turning the load on and off from its built-in switch

The load will turn on and off

Disable Load Sensing

1) Press & hold the Set button on ApplianceLinc for 3 seconds

The ApplianceLinc Status LED will begin blinking

2) Double-tap the Set button on ApplianceLinc

The ApplianceLinc Status LED will stop blinking and turn on solid

3) Test that Load Sensing has been disabled by turning the load on and off from its built-in switch

The load will not respond

Restoring Power to ApplianceLinc

ApplianceLinc stores all of its settings, such as Links to other INSTEON devices, with non-volatile memory. Because settings are saved in this non-volatile memory, they will not be lost in the event of a power failure.

In the event of a power loss ApplianceLinc will automatically default the load to off when power is restored.

Resetting ApplianceLinc to its Factory Default Settings

The factory reset procedure can be used to clear the ApplianceLinc memory of all INSTEON Links and

X10 addresses

1) If you are using a Controller to control ApplianceLinc, be sure to Unlink it from the Controller. See

Unlinking ApplianceLinc from an INSTEON Controller.

2) Unplug ApplianceLinc for about 10 seconds

3) While holding down the Set button on ApplianceLinc, plug it back in, making sure not to let go of the

Set button

4) Continue to hold down the Set button for 3 seconds and then release

The ApplianceLinc Status LED will flash once and then turn off

After a few seconds, the Status LED and the load will turn on