EPC

®

-3311 Hardware Reference

The bios.rom file is 512KB. At 38.4K baud, the download takes about 3.5 minutes. When the download is complete, the Crisis Reflash program automatically reflashes the FBD and displays these messages:

Block:(MAIN BLOCK 1) Erase:Ok. Programming:Ok

Block:(MAIN BLOCK 2) Erase:Ok. Programming:Ok

Block:(MAIN BLOCK 3) Erase:Ok. Programming:Ok

Block:(MAIN BLOCK 4) Erase:Ok. Programming:Ok

Flash Update Successful!

RadiSys Flash Recovery Console, Version EPC-3311 1.0

Copyright (c) RadiSys Corporation. All rights reserved.

Valid Commands:

BIOS Reflash the System BIOS

EXIT Exit the Flash Recovery Console

Enter Command:

11. Move the jumper on J7 pins back to the original position:

J7

1 3

Re-connect pins 1 and 2 to return the header to default position.

12. Reset the system, then ensure that the update completed by checking the version number of the updated BIOS in the sign-on screen or BIOS Setup Main menu.

Perform Crisis Reflash from LS-120 drive

The EPC-3311 Crisis Reflash Program can boot and reflash from 1.44MB floppy diskette inserted in an IDE LS-120 Superdrive installed on either the on-board IDE connector or the RTM IDE connector.

1. Ensure that you have the following:

• The files in nnnncris.zip.

• (Optional) An installed RadiSys POST card. The LS-120 crisis reflash gives no other indication of progress or completion. If you don't have a POST

Card, wait 3 minutes and try the BIOS.

2. Disconnect IDE devices from all IDE connectors and busses, including devices on the MM50 and the CompactFlash.

3. Jumper the LS-120 drive as IDE Master.

4. Create a Crisis Reflash diskette:

This process is supported only on MS Windows. Linux is not supported.

A. Insert a1.44MB 2HD IBM/DOS formatted diskette in floppy drive A: of the system where you unzipped the nnnncris.zip file. Make sure the floppy is not write-protected.

Ensure that the data on the disk is either not valuable or backed up.

This process will re-format the diskette and erase all previous data.

13

2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Appendix I: Re-programming the flash chip

B. Run one of these programs: crisdisk.bat

1. Run wincris.exe from the command line or Explorer.

2. Ensure that Disk Options is set to “Create MiniDOS Crisis

Disk”.

3. Click Start. When the Format

A: dialog box displays, you may elect to check the "Quick

Format" checkbox.

4. Click Start, then OK. When the format finishes, close the

Format A: dialog. wincris.exe copies the files.

5. Remove the diskette when prompted, then click OK.

wincris.exe

1. Run crisdisk.bat, either from a command line or the Explorer. The batchfile prompts you for input.

2. Enter information as prompted. The batch file eventually displays this message:

QuickFormatting 1.44M

Format complete.

Volume label (11 characters,

ENTER for none)?

3. Press the Enter key. The batch file displays this message:

Volume Serial Number is D87F-

D24A

QuickFormat another (Y/N)?

press N.

The batch file copies files to the diskette and creates the special boot sector.

4. Label the diskette:

Recovery Diskette

BIOS Version N.MM.LL

Where N.MM.LL is the version number from README.TXT.

5. Boot the Crisis Reflash Diskette on the EPC-3311:

A. Connect these J7 pins to activate the Crisis Reflash program:

J7

1 3

You must jumper pins 2 and 3 to activate the Crisis Recovery program

For more information about this jumper, see

ROM_TOP (J7)

on page 12.

A. Insert the special 1.44MB Crisis Reflash diskette in the LS-120 drive.

B. Reset or power-up the EPC-3311.

The Crisis Reflash program boots from the LS-120 drive, loads the bios.rom file, and tries to reflash the BIOS.

C. Do one of these to ensure that boot is complete before moving to the next step:

• Wait until the POST card indicates success by displaying “1Eh”.

• Wait three minutes.

6. Move the jumper on J7 pins back to the original position:

J7

1 3

Re-connect pins 1 and 2 to return the header to default position.