INSTALLATION INSTRUCTIONS

INTERIOR-MOUNTED VENT MOTOR

Island location

Venting Methods - Interior Mounted Vent Motor Only

Determine which venting method is best for your application.

Vent system can terminate through either the wall or floor.

Island Location

Vent system installed under a concrete slab using PVC sewer pipe.

Front (Standard) Mounted Blower Motor

Front (standard) mounted blower motor

Rear mounted blower motor

B

A

D

A. Down vent

NOTE: For island locations, the blower motor can be mounted for right, left, or rear venting if needed for your application. Most island applications would still require the venting to be directed down through the floor.

Built-in cabinet locations

A

A

B

A

M

C

E

F

H

G

L

K

J

Rear Mounted Blower Motor

B

I

A

D

M

C

E

F

G

L

H

K

J

I

A. Wall cap

B. 6" (15.2 cm) round metal vent

C. 16" (40.6 cm) maximum

D. 6" (15.2 cm) round PVC sewer pipe

E. 6" (15.2 cm) round metal vent

F. 6" (15.2 cm) round PVC coupling

G. Concrete slab

H. 6" (15.2 cm) round PVC sewer pipe

I. 6" (15.2 cm) round 90° PVC sewer pipe elbow

J. Tightly pack gravel or sand completely around pipe.

K. 6" (15.2 cm) round 90° PVC sewer pipe elbow

L. 6" (15.2 cm) round PVC coupling

M. 12" (30.5 cm) minimum

D

C

A. Down vent

B. Rear vent

C. Left vent

D. Right vent

Calculating Vent System Length

It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 6" (15.2 cm) round vent as soon as possible.

Maximum Length of Vent System

Vent Length

6" (15.2 cm) round

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

35 ft (8.9 m)

35 ft (8.9 m)