Chapter 3

How to use the LCD Display Monitor

LAN remote control

When you connect the display and the computer using a LAN hub and a LAN cable (see page 31), and then configure the network settings using ETHERNET SETTING in the SETUP menu of the OSD, you can control the LCD display remotely using the same commands as for RS-232C.

Setting procedure:

1

Select LAN as the communication interface used for the serial communication function. (See page 55, and see also the Control Setting in the "Setup Menu Screen" on page 65).

2

Set the following network paramaters using the OSD menu.

• DHCP client ON/OFF, IP address, subnet mask and default gateway.

3

Set the IP address described above and the port number (4660) using the application program of your computer to perform the socket communication.

4

Send the same control command as for RS-232RC via TCP/IP socket communication.

5

Check the return command sent from the LCD display. When it is received successfully, the setting is complete.