- No category
advertisement
Overview of the installation procedure
Installing the controller in an unconfigured server blade
New HP ProLiant server models autoconfigure when they are powered up for the first time. For more information about the autoconfiguration process, see the server-specific setup and installation guide or the
HP ROM-Based Setup Utility User Guide. These guides are available on the server Documentation CD.
IMPORTANT: Do not power up the server until the hardware configuration is satisfactory, as described in the procedure given in this section.
To install the controller in an unconfigured server blade:
1.
Install the controller hardware in the server blade.
2.
3.
4.
5.
6.
Install the server blade in a blade enclosure.
Install an HP 3Gb SAS BL-c Pass-Thru Module in the blade enclosure.
Connect the server blade to the pass-thru module.
Connect the pass-thru module to a drive enclosure.
If necessary, install physical drives in the drive enclosure.
The number of drives connected to the pass-thru module determines the RAID level that is autoconfigured when the server is powered up. For details, see the server-specific setup and installation guide or the HP ROM-Based Setup Utility User Guide.
7.
8.
9.
10.
11.
Power up the server. The autoconfiguration process runs.
Update the server firmware ("
Methods for updating the firmware " on page 10 ).
Update the controller firmware ("
Methods for updating the firmware " on page 10 ).
Install the operating system and device drivers ("
Installing device drivers " on page 14 ). Instructions
are provided with the CD that is supplied in the controller kit.
(Optional) Create additional logical drives ("
Configuring an array " on page 11 ).
The server is now ready to use.
Installing the controller in a previously-configured server
1.
2.
3.
Back up data on the system.
Update the server blade firmware ("
Methods for updating the firmware " on page 10 ).
If the new controller will be the boot device, install the device drivers ("
Installing device drivers " on
page
14 ). Otherwise, go directly to step 4.
Overview of the installation procedure 7
9.
10.
11.
12.
13.
14.
15.
4.
5.
6.
7.
8.
16.
17.
18.
Power down the server blade.
Remove the server blade from the enclosure.
Remove the access panel from the server blade.
Install the controller hardware ("
Installing the controller hardware " on page 9 ).
Reinstall the access panel.
Reinstall the server blade in the enclosure.
Install an HP 3Gb SAS BL-c Pass-Thru Module in the enclosure.
Connect the server blade to the pass-thru module.
Connect the pass-thru module to a drive enclosure.
Power up the server blade.
Update the controller firmware ("
Methods for updating the firmware " on page 10 ).
(Optional) Set this controller as the boot controller using ORCA ("
Setting a controller as the boot controller " on page 12 ).
(Optional) Change the controller boot order using RBSU ("
Setting the controller order " on page 12 ).
If the controller will not be the boot device, install the device drivers ("
Installing device drivers " on
page
If new versions of the Management Agents are available, update the Management Agents
("
Installing Management Agents " on page 14 ).
Overview of the installation procedure 8
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 HP Smart Array P700m Controller for HP ProLiant Servers User Guide
- 2 Notice
- 3 Contents
- 5 Hardware features
- 5 Main components on the controller board
- 5 Controller specifications
- 7 Overview of the installation procedure
- 7 Installing the controller in an unconfigured server blade
- 7 Installing the controller in a previously-configured server
- 9 Installing the controller hardware
- 9 Preparing the server blade
- 9 Installing the controller board
- 10 Updating the firmware
- 10 Methods for updating the firmware
- 11 Configuring an array
- 11 Utilities available for configuring an array
- 12 Setting the boot controller and controller order
- 12 Setting a controller as the boot controller
- 12 Setting the controller order
- 14 Installing device drivers and Management Agents
- 14 Installing device drivers
- 14 Installing Management Agents
- 15 Upgrading or replacing controller options
- 15 Replacing the battery
- 18 Replacing, moving, or adding hard drives
- 18 Identifying the status of a hard drive
- 19 Recognizing hard drive failure
- 20 Effects of a hard drive failure
- 20 Compromised fault tolerance
- 20 Recovering from compromised fault tolerance
- 21 Replacing hard drives
- 21 Factors to consider before replacing hard drives
- 22 Automatic data recovery (rebuild)
- 22 Time required for a rebuild
- 23 Abnormal termination of a rebuild
- 24 Upgrading hard drive capacity
- 24 Moving drives and arrays
- 25 Adding drives
- 27 Diagnosing array problems
- 27 Controller board runtime LEDs
- 28 Battery pack LEDs
- 29 Diagnostic tools
- 31 Electrostatic discharge
- 31 Preventing electrostatic discharge
- 31 Grounding methods to prevent electrostatic discharge
- 32 Regulatory compliance notices
- 32 European Union regulatory notice
- 32 BSMI notice
- 33 Korean class A notice
- 33 Battery replacement notice
- 33 Taiwan battery recycling notice
- 34 Acronyms and abbreviations
- 35 Index