GSM-VAC4+

Add to my manuals
57 Pages

advertisement

GSM-VAC4+ | Manualzz

GSM-VAC4+ INSTALLATION MANUAL

11.8

EVENT LOG PARAMETERS

GSM-VAC4+ has a small set of parameters to manage log memory.

11.8.1

LOGN parameter

LOGN parameter is used to define the number of log events that will be send out in case of PLOG command

11.8.2

LOGI parameter

LOGN parameter is used to enable and define GSM-VAC4+ log storage.

⇒ LOGI=0 Logging is OFF

⇒ LOGI=1 Logging in internal memory

⇒ LOGI=2 Logging to USB interface

11.8.3

ALC parameter

ALC parameter defines an action in case when the LOG memory is FULL

⇒ ALC=0 Automatically delete buffer when memory is FULL

⇒ ALC=1 Memory buffer must be deleted manually when it is FULL

Table of parameters:

Name

LOGI

LOGN

ALC

Comment

Log storage

Number of log events for print

Control for memory handling in case memory storage is full

Table 33: LOG parameters

Example:

Direct programming on the SIM card

Name

LOGI

LOGN

ALC

GSM-VAC4+ PROGRAMMING TABLE

SIM CARD PHONE BOOK

Number

1

10

1

Description

Use internal GSM-VAC4+ storage

Send 10 events in case of PLOG request

Automatically delete memory buffer when is full

Table 34: LOG parameters example

Remote programming by SMS

;LOGI=1;LOGN=10;ALC=1;