GSM-VAC4+

Add to my manuals
57 Pages

advertisement

GSM-VAC4+ | Manualzz

GSM-VAC4+ INSTALLATION MANUAL

12.9

RECEIVE CREDIT CHECK PARSE STRING PARAM. (PCREF)

By sending this command to GSM-VAC4+ you receive SMS message with all currently programmed credit parse string parameters (CREF, CTIM and CVODA) . Send: ;PCREF;

12.10

RECEIVE CREDIT STATUS FOR CC1 (PCC1)

By sending this command to GSM-VAC4+ you receive SMS message with current credit status and

SMS received from the GSM provider. Send: ;PCC1;

12.11

RECEIVE CREDIT STATUS FOR CC2 (PCC2)

By sending this command to GSM-VAC4+ you receive SMS message with current credit status and

SMS received from the GSM provider. Send: ;PCC2;

12.12

RECEIVE CREDIT STATUS FOR CC3 (PCC3)

By sending this command to GSM-VAC4+ you receive SMS message with current credit status and

SMS received from the GSM provider. Send: ;PCC3;

12.13

RECEIVE CLIP IDENTIFICATION FUNCTIONS (PTC)

By sending this command to GSM-VAC4+ you receive SMS message with all currently programmed CLIP function to dedicated telephone number (TC1 – TC0). Send: ;PTC;

12.14

RECEIVE ACCESS TELEPHONE NUMBERS (PSL)

By sending this command to GSM-VAC4+ you receive SMS message with programmed SL level.

Send: ;PSL;

12.15

RECEIVE OUTPUT PARAMETERS (POS)

By sending this command to GSM-VAC4+ you receive SMS message with all currently programmed Outputs parameters (OS1 – OS4). Send: ;POS;

12.16

RECEIVE LINK FOR LOCAL ALARM OUTPUT (POD)

By sending this command to GSM-VAC4+ you receive SMS message with all currently programmed direct output alarm links (OD1 – OD11). Send: ;POD;

12.17

RECEIVE ALL PROGRAMMED SMS MESSAGES (P#)

By sending this command to GSM-VAC4+ you receive SMS message with all currently programmed alarm SMS messages (#0 - #4). Send: ;P#;

37

GSM-VAC4+ INSTALLATION MANUAL

12.18

RECEIVE THE POWER LEVEL ON THE UNIT (PPWR)

By sending this command to GSM-VAC4+ you receive SMS message with current main power level in volts or current battery voltage when the unit runs on the backup battery. Send: ;PPWR;

12.19

RECEIVE SET-UP PARAMETERS VALUE (PPA)

By sending this command to GSM-VAC4+ you receive SMS message with all currently programmed Setup parameters (CRE, MNF, MAIN…). Send: ;PPA;

12.20

STATE OF THE CREDIT FOR THE PREPAID CARD

By sending this command to GSM-VAC4+ you receive SMS message with Credit amount on your prepaid SIM card. Send: ;PCCX; Where X is the number of programmed prepaid card provider.

12.21

RECEIVE CID PARAMETERS (PCID)

By sending this command to GSM-VAC4+ you receive SMS message with CID configuration.

Send:v;PCID;

12.22

RECEIVE SIMPLE CLIP PARAMETERS (PCLP)

By sending this command to GSM-VAC4+ you receive SMS message with simple CLIP configuration. Send: ;PCLP;

12.23

RECEIVE LOG PARAMETERS AND EVENTS (PLOG)

By sending this command to GSM-VAC4+ you receive SMS messages with log parameters and log events. Send: ;PLOG;

NOTE

When working with SMS use this parameter print with care. It might generate lot of

SMS messages in replay.

12.24

STATE OF THE OUTPUTS (PORC)

By sending this command to GSM-VAC4+ you receive SMS message with current outputs state.

Send: ;PORC;

12.25

STATE OF THE INPUTS (INS)

By sending this command to GSM-VAC4+ you receive SMS message with current input state.

Send: ;INS;

12.26

RECEIVE SYSTEM STATUS (PSYS)

By sending this command to GSM-VAC4+ you receive SMS message system current time and up time. Send: ;PSYS;

38

GSM-VAC4+ INSTALLATION MANUAL

13

SYSTEM COMMANDS

Next system commands are used to help the user to control the operation of GSM-VAC4+ device.

13.1

FACTORY DEFAULT COMMAND (SDCLR)

SDCLR command is used to delete all parameters and SMS on SIM card. After delete process is completed the system will be restarted. Now GSM-VAC4+ will be loaded with factory default settings (Paragraph 20).

;SDCLR;

13.2

GSM MODULE RESTART (MRES)

MRES command is used to restart GSM module.

;MRES;

13.3

SYSTEM RESTART (SSRES)

SSRES command is used to restart GSM-VAC4+.

;SSRES;

13.4

LOG MEMORY CLEAR (LCLR)

LCLR command is used to manually clear internal memory storage of log.

;LCLR;

13.5

REMOVE ALL CLP USER (CLPCL)

CLPCL command is used to delete all CLIP users (CLP1 - CLP50).

;CLPCL;

39

GSM-VAC4+ INSTALLATION MANUAL

14

CHECKING AND CHANGING SYSTEM STATUS

(ON/OFF)

14.1

CHECKING SYSTEM STATUS BY SMS COMMAND

By sending this command to GSM-VAC4+ you receive SMS message with state of the system:

;SYS;

Return SMS can be:

;SYS= ON; System is ON (active inputs)

;SYS= OFF; System is OFF (inputs are not active)

14.2

CHANGING SYSTEM STATUS TO ON (SYSTEM ON)

By sending this command to GSM-VAC4+ it switches the system ON.

;SYS=1; or ;SYS=ON;

14.3

CHANGING SYSTEM STATUS TO OFF (SYSTEM OFF)

By sending this command to GSM-VAC4+ it switches the system OFF.

;SYS=0; or ;SYS=OFF;

40

GSM-VAC4+ INSTALLATION MANUAL

15

CHECKING THE INPUT STATUS

User can check input status with the use of SMS command.

15.1

CHECKING INPUT STATUS BY SMS COMMAND

By sending this command to GSM-VAC4+ you receive SMS message with all Input status:

;INS;

Return SMS message is:

;INS(1-4)=(OPEN-ON) – alarm loop is open and the input is in alarm state

;INS(1-4)=(OPEN-OFF) – alarm loop is open and the alarm input is in idle state

;INS(1-4)=(LOW-ON) – alarm loop is close on GND and the input is in alarm state

;INS(1-4)=(LOW-OFF) – alarm loop is close on the GND and the alarm input is in idle state

;INS(1-4)=(HGH-ON) – alarm loop is close on +12MCC and the input is in alarm state

⇒ ;INS(1-4)=(HIGH-OFF) – alarm loop is close on +12V and the alarm input is in idle state

41

GSM-VAC4+ INSTALLATION MANUAL

42

GSM-VAC4+ INSTALLATION MANUAL

16

CHECKING AND CHANGING OUTPUT STATUS

User can manage outputs with the use of SMS command.

16.1

CHECKING OUTPUT STATUS BY SMS COMMAND

By sending this command to GSM-VAC4+ you receive SMS message with all Output status:

;PORC;

Return SMS message is:

⇒ ;Output 1=(ON-OFF) – status on output 1.

⇒ ;Output 2=(ON-OFF) – status on output 2.

⇒ ;Output 3=(ON-OFF) – status on output 3.

⇒ ;Output 4=(ON-OFF) – status on output 4.

16.2

ORC PARAMETER

This parameter is used to control outputs directly via SMS message.

16.3

OUTPUT REMOTE CONTROL BY SMS COMMAND

By sending this command to GSM-VAC4+ the output X is switched ON:

;ORCX=1;

For X please choose one of the output numbers from 1 to 4.

By sending this command to GSM-VAC4+ the output X is switched OFF:

;ORCX=0;

For X please choose one of the output numbers from 1 to 4.

If you would like to receive SMS message with the Output status write “+” before SMS command:

;+ORCX=1;

For X please choose one of the output numbers from 1 to 4.

Return SMS message is:

ORCX=(ON)

Where X is one of the output numbers from 1 to 4.

Table of parameters:

Name

ORC1

ORC2

ORC3

ORC4

Comment

Control of output 1

Control of output 2

Control of output 3

Control of output 4

Table 35: ORC parameters

Example:

Remote programming by SMS

SMS commad

;ORC1=1;

;ORC2=0;

Activate output 1

Deactivate output 2

Description

Table 36: ORC parameters example

43

GSM-VAC4+ INSTALLATION MANUAL

17

CHANGING PARAMETERS USING THE SMS

COMMAND

All programming parameters for GSM-VAC4+ can also be sent by SMS command. Each SMS command should start and stop with semicolon. If the confirmation SMS is needed, put “+” at the beginning of the command SMS.

The first SMS is SMS with telephone numbers (TN1 – TN0). If you would like to check which telephone numbers are programmed in GSM-VAC4+ please use the following command:

;PTN;

Return SMS is (example):

;TN0=0;TN1=0;TN2=0;TN3=0;TN4=0;TN5=0;TN6=0;TN7=0;TN 8=0;TN9=0;

If you would like to enter telephone numbers in to GSM-VAC4+ you can use the following example:

;

TN0=040713470;TN1=+38643364850;TN2=041255630;TN3=0;TN4=0;TN5=0;TN6=0;TN

7=0;TN8=0;TN9=0;

;

If you would like to receive confirmation SMS write “+” before SMS command:

+TN0=040713470;TN1=+38643364850;TN2=041255630;TN3=0;TN4=0;TN5=0;TN6=0;T

N7=0;TN8=0;TN9=0;

Return SMS from GSM-VAC4+ is:

;

TN0=040713470;TN1=+38643364850;TN2=041255630;TN3=0;TN4=0;TN5=0;TN6=0;TN

7=0;TN 8=0;TN9=0;

NOTE

You can use the same programming procedure for all parameters.

NOTE

It is also possible to change different parameters with one SMS. Consider that the SMS message should not be longer than 160 characters (included space characters).

If you would like to change the following parameters TN1, IN1, IN2, OS3, OS4; ID1, LN1 and

CRE and would like to receive confirmation SMS, try next example:

;+TN1=+38640713470;IN1=1;IN2=1;OS3=15;ID1=120;LN1=1;CRE=4;

44

GSM-VAC4+ INSTALLATION MANUAL

Send SMS message to GSM-VAC4+ telephone number and in a few seconds you receive SMS message from GSM-VAC4+. The sentence of the SMS must be the same as the one you have sent to GSM-VAC4+ before.

45

GSM-VAC4+ INSTALLATION MANUAL

18

CONFIGURATION EXAMPLES

Here are listed few simple configuration examples.

18.1

ALARM CONFIGURATION

To send alarm on input 1 please set these parameters:

;LN1=123;TN1=040211411;TN2M=041211511;TN3=051334556;

With these configuration alarm notification will be send to TN1 (voice and SMS), TN2 (only SMS) and TN3 (only voice).

18.2

CID EVENT REPORTING

This example represents how to enable CID function for GSM-VAC4+ event reporting. The data will be sending to 1 CMS.

;CID=1;CIN=15;COUT=12;TN11=042340880;

46

GSM-VAC4+ INSTALLATION MANUAL

19

TECHNICAL SPECIFICATIONS

Description

Power Supply

Battery backup (optional)

Current consumption - peak

Current consumption - transmitting mode

Current consumption - idle mode

QUAD band GSM module

PCB dimensions

Unit dimensions

Unit dimensions - IP56 box

Antenna SMA

Weight (without battery)

Alarm inputs

Alarm outputs (open collector)

ON/OFF input

12V DC Power Supply output

Backup battery input

No. of alarm SMS per unit

No. of prerecorded messages

Programmed telephone numbers

Anti-tamper protection

CLIP numbers

Event log buffer

Table 37: GSM-VAC4+ - Technical specifications

Value

13,8 - 14,7V DC

12V/1,2Ah

2A

250mA

90mA

850/900/1800/1900 MHz

105 × 80 mm

120 × 170 × 60 mm

155 × 220 × 82 mm

1

550g

4

4

1

4

4

Y

Y

10

Y

50

1000

47

GSM-VAC4+ INSTALLATION MANUAL

Name

OD9

OD11

OD11

LN1

LN2

LN3

LN4

LN5

OS4

OD1

OD2

OD3

OD4

OD6

OD7

OD8

IN1

IN2

IN3

IN4

ION

OS1

OS2

OS3

TN1

TN2

TN3

TN4

TN5

TN6

TN7

TN8

TN9

TN0

LN6

LN7

LN8

LN9

LN10

LN11

ID1

ID2

ID3

ID4

DON

20

DEFAULT SETTINGS ON GSM-VAC4+

GSM-VAC4+ PROGRAMMING TABLE

Default Value Short Description

0

0

0

Empty

Empty

Empty

Empty

Empty

4

0

0

0

0

0

1

0

1

1

4

1

0

0

0

0

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

Empty

1

1

1

1

1

Telephone number 1

Telephone number 2

Telephone number 3

Telephone number 4

Telephone number 5

Telephone number 6

Telephone number 7

Telephone number 8

Telephone number 9

Telephone number 0

Input 1 control

Input 2 control

Input 3 control

Input 4 control

System ON/OFF control

Output 1 mode

Output 2 mode

Output 3 mode

Output 4 mode

Input 1 direct output link

Input 2 direct output link

Input 3 direct output link

Input 4 direct output link

GSM network error direct output link

System tamper direct output link

System ON/OFF direct output link

NAC direct output link

Listen in indication

CID transfer error

Input 1, link to tel. numbers

Input 2, link to tel. numbers

Input 3, link to tel. numbers

Input 4, link to tel. numbers

Main power indication, link to tel. numbers

Battery power indication, link to tel. numbers

Periodic SMS, link to tel. numbers

SIM card validity and credits status, link to tel. numbers

System tamper, link to tel. numbers

NAC, link to tel. numbers

LOG status, link to tel. numbers

Input 1 delay filter on input

Input 2 delay filter on input

Input 3 delay filter on input

Input 4 delay filter on input

System ON/OFF delay filter input

48

GSM-VAC4+ INSTALLATION MANUAL

Name

AR2

AR3

AR4

IB1

IB2

IB3

IB4

#0

TC9

TC0

SL

IT1

IT2

IT3

IT4

AR1

DD1

DD2

DD3

DD4

DDN

TC1

TC2

TC3

TC4

TC5

TC6

TC7

TC8

UDC

HTN

SCV

TST

TSTT

MNF

MIC1

MIC2

CC1

CC2

CC3

CRE

#1

#2

#3

#4

SPK

BIDI

AUD

LCV

GSM-VAC4+ PROGRAMMING TABLE

Default Value Short Description

“Input1”, 130

“Input2”, 110

“Input3”, 120

“Input4”, 100

Empty

Empty

Empty

3

Empty

1

0

0

0

0

15

15

12

0

0

4

0

0

0

0

0

0

0

0

0

0

0

0

0

Input 1 delay before dialing

Input 2 delay before dialing

Input 3 delay before dialing

Input 4 delay before dialing

System ON/OFF delay before dialing

Advanced CLIP telephone number 1 function

Advanced CLIP telephone number 2 function

Advanced CLIP telephone number 3 function

Advanced CLIP telephone number 4 function

Advanced CLIP telephone number 5 function

Advanced CLIP telephone number 6 function

Advanced CLIP telephone number 7 function

Advanced CLIP telephone number 8 function

180

180

180

5

0

0

0

180

Advanced CLIP telephone number 9 function

Advanced CLIP telephone number 10 function

Security level

Predefined time for alarm filtering, input 1

Predefined time for alarm filtering, input 2

Predefined time for alarm filtering, input 3

Predefined time for alarm filtering, input 4

Number of allowed events in predefined time, input 1

5

5

5

3600

Number of allowed events in predefined time, input 2

Number of allowed events in predefined time, input 3

Number of allowed events in predefined time, input 4

Input blocked time for alarm filtering, input 1

3600

3600

Input blocked time for alarm filtering, input 2

Input blocked time for alarm filtering, input 3

3600 Input blocked time for alarm filtering, input 4

“User Location”, 1111 SMS main head text

SMS input 1 text

SMS input 2 text

SMS input 3 text

SMS input 4 text

Check credit Num 1

Check credit, TIM Italy

Check credit, Vodafone Italy

Number of dialing attempts

Tel. number of GSM-VAC4+ device

Hidden telephone number

SIM card time validity

Periodic test SMS timeout

Test SMS reference point

Network connection type

Microphone 1 volume setting ( 0 - 40 )

Microphone 2 volume setting ( 0 - 40 )

Speaker volume setting ( 0 - 20 )

Special predefined MIC/SPK group settings

Different audio modes

Low credit value

49

GSM-VAC4+

Name

ARST

LED

ADF

REG

CREF

CTIM

CVODA

SPO

CLPEN

CLPI

CLPOU

CLP1

.

.

.

CLP50

LNG

MAIN

BATT

RTN

LOT

CID

CIN

COUT

TN11

TN12

LOGN

LOGI

ALC

GSM-VAC4+ PROGRAMMING TABLE

Default Value Short Description

0

1

90

30

“EUR”

“EURO”

“DISPON. E.”

1

0

0

1

Empty

.

.

.

Empty

0

15

15

Empty

Empty

5

0

1

0

5

20

45

90

Language selection

Main power down input filter

Battery power loss input filter

Ring time before going to next number

Connection time out value

Contact ID enable/disable

Contact ID input level( 0 - 20 )

Contact ID output level( 0 – 40 )

Contact ID telephone number 1

Contact ID telephone number 2

Number of log events for printing out

Log storage place

Automatic log clear

Automatic reset timeout

Led function enable/disable

Auto dial function

Out of GSM registration

Parse text( contact support )

Parse text( contact support )

Parse text( contact support )

SIM card starting position

Enable CLIP functionality

Precondition for CLIP function

Control output pin when CLIP event

CLIP number 1

CLIP number 50

Table 38: GSM-VAC4+ - Default settings.

INSTALLATION MANUAL

50

GSM-VAC4+

21

CONTACTS

INSTALLATION MANUAL

EDGARSSON SECURITY DESIGNS, CILYMAENLLWYD HOUSE, LOGIN, WHITLAND, SA34 0XA

Phone 01437 563 900 Fax 01437 563475 Email [email protected]

Web pages at www.edgarsson.co.uk

51

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals