TLE8457
LIN Transceiver with integrated Voltage Regulator
Functional Description
4.1.1
Normal Operation Mode
In Normal Operation Mode both the voltage regulator and the LIN transceiver are active. The TLE8457 supports data transmission rates up to 20 kBit/s: Data from the microcontroller is transmitted to the LIN bus via the TxD input, while the receiver detects the data stream on the LIN bus and forwards it to the RxD output.
After entering Normal Operation Mode the TLE8457 requires a logical “high” signal for the time t to,rec
on the
TxD input before releasing the data communication; The transmitter remains deactivated as long as the signal on the TxD input pin remains logical “low”, preventing possible bus communication disturbance (see
Figure 4
).
From Normal Operation Mode the TLE8457 can be set to Standby Mode or Sleep Mode.
EN
t
MODE,HIGH
t
MODE,LOW t
V
CC t
NRST t
RxD
Data transmission
t
to,rec t
TxD Data transmission
Standby mode Normal Operation mode t
Sleep mode
TLE8457_NORMAL_MODE
Figure 4 Entering Normal Operation Mode, transition to Sleep Mode
4.1.2
Standby Mode
Standby Mode is a low power mode with ultra low quiescent current consumption while the voltage regulator remains active, supplying for example a microcontroller in Stop mode. No LIN bus communication is possible, the transmitter and the receiver are disabled. The low power receiver is still active and the device can wakeup by a message on the LIN bus.
For changing the operation mode change from Standby Mode to Sleep Mode, the device has first to be set in
Normal Operation Mode, then in Sleep Mode (see
Figure 4
).
Data Sheet 8 Rev. 1.0
2016-08-05
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Overview
- 3 Table of Contents
- 4 Block Diagram
- 5 Pin Configuration
- 5 Pin Assignment
- 5 Pin Definitions and Functions
- 6 Functional Description
- 6 Operating Modes
- 8 Normal Operation Mode
- 8 Standby Mode
- 9 Init Mode
- 10 Sleep Mode
- 10 Bus Wake-up event
- 11 Mode Transition via EN pin
- 12 Power Supplies
- 12 Power-Up / Power-Down
- 13 Undervoltage Detection
- 14 Voltage Regulator
- 14 VCC Undervoltage Detection
- 14 Reset Output
- 15 Initialization Watchdog
- 17 LIN Transceiver
- 18 TxD Time-out
- 18 Short Circuit
- 18 Over-temperature Protection
- 19 General Product Characteristics
- 19 Absolute Maximum Ratings
- 20 Functional Range
- 21 Thermal Characteristics
- 22 Electrical Characteristics
- 22 Functional Device Characteristics
- 28 Diagrams
- 29 Application Information
- 29 Application Example
- 30 ESD Robustness according to IEC
- 30 Transient Robustness according to ISO
- 30 LIN Physical Layer Compatibility
- 31 Package Outlines
- 32 Revision History