Troubleshooting. Graco 332453G - ExactaBlend AGP Advanced Glazing Proportioner - Accessories

Add to my manuals
16 Pages

advertisement

Troubleshooting. Graco 332453G - ExactaBlend AGP Advanced Glazing Proportioner - Accessories | Manualzz

Troubleshooting

Troubleshooting

Problem

The sensor does not activate.

Screen 4 does not show the USB option.

1. Follow Pressure Relief Procedure in the Exacta

Blend AGP Advanced Glazing Proportioner,

Setup-Operation manual before checking or repair ing gun.

2. Check all possible problems and causes before dis assembling gun.

Cause

S100 Low Level Sensors

The low level sensor option has not been activated on the DM.

The sensor has not been mounted correctly.

The collar has been installed too high on the shaft.

Bad connection or cable

Solution

Navigate to Screen 1 and activate the low level sensor option.

Adjust the sensor until it is activated by the collar.

Lower the collar until the sensor is activated.

Ensure cable is connected or replace the cable.

Replace sensor.

Bad sensor

USB Kit

Bad connection or cable.

Bad GCA components.

Ensure cable is connected or replace the cable.

Replace the GCA components.