680 Series
L3 Lock Mode (disables the temperature up and down buttons to prevent unauthorized temperature adjustments). Filtration/heating cycle will continue to operate as programmed in this mode. The jets and lights buttons will still continue to operate as normal. The temperature display flashes when this function is enabled.
Note: To exit a Lock Mode you will need to re-enter the filtration/heating modes and select a cycle from F1-F6.
10.6 Programming the CLEARRAY (Ultraviolet) Water Purification
System (If equipped)
A. Programming the CLEARRAY System (U) or Corona Discharge
Ozone (O3)
Press and hold the Jets pump 1 and Cooler button at the same time for 3 seconds to enter the sanitizing system program. The screen will display one of the two menus below:
CLEAR RAY menu
Press
O3 menu
Press or or
1. If the LED screen is displaying “U” then pressing the Jets pump
1 will change the sanitizing system from “U” to “O3” and exit the programming menu. If the LED screen is displaying “O3” then pressing the Jets pump 1 will change the sanitizing system from “O3” to “U” and exit the programming menu.
Note: For the O3 option the “=” disables the duration countdown timer.
2. If you do not wish to change the option do not press any buttons and after 10 seconds the display will return to the main menu.
Note: If the CLEARRAY System has been selected, when the time allotted has expired (365 days) the display screen will flash between the water temperature and “blb.” At this time the UV bulb must be replaced, the quartz tube must be cleaned and the duration countdown timer needs to be reset. If the “blb” message appears on the control panel and you do not have the CLEAR RAY system, just follow the steps in following section to reprogram and clear the message.
Page 31
680 Series
B. Resetting the duration countdown timer (CLEARRAY System
only)
Once the duration countdown timer for the CLEAR RAY System has reached zero, you will need to reset it, replace the UV bulb and clean the quartz tube.
To reset the duration countdown timer:
Press Press
1
1. Press and hold the Jets pump and Cooler button at the same time for 3 seconds.
2. Press the Warmer button until the display shows “0.”
3. If the timer has reached “0,” pressing the Jets pump 1 button will reset it.
If the timer is not at “0” pressing the Jets pump 1 button will not reset it.
Note: If the spa power is interrupted, the duration countdown timer is not affected. The number of days remaining is stored in the memory and will continue to countdown once power is regained.
4. If the duration countdown timer is not at “0” and you need to reset it: a. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
b. Press the Warmer button to scroll to “U.” c. Press the Jets pump 1 button to switch from “U” to “O3.” d. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
e. Press the Warmer button to scroll to “O3.” f. Press the Jets pump 1 button to switch from “O3” to “U.” The timer has been reset to 365 days.
Page 32