DigiOpG2 Digital Video Recorder

Fast Playback Backwards Button

Playback Button

Fast Playback Forward Button

Playback Backward Frame by

Frame

Pause Button

Playback Forward Frame by Frame

23

24

25

20

21

22

OSD Button

P/T/Z Button

SEQ Button

26

27

28

Note Button #16: F/O/E Button (use only on remote controller)

The object in the recorded image might show the feathering effect during frame playback because images at

720x480(PAL:720×576) resolution have higher vertical resolution than 640x240(PAL:640×288) or 352×240

(PAL:352×288). The feathering of the image can be solved when only one of two Fields (Odd, Even Field) is selected. Default is frame playback. When the button is pressed, it will change to Odd Field Playback-> Even Field

Playback-> Frame Playback order.

Note

To use the IR Remote Controller, synchronize front panel button and IR remote controller by inputting the initial ID.

The user requires setting the ID only once. Refer to “Settings” for detailed information about ID input.

Note

When the IR Remote Controller is used to change the channel, no. 1 button is also used to select channels after number 10. Press no. 1 button and it will be ready to add another extra number. Example, press no. 1 and once it is ready to add another no., press 2. Then, channel will change to channel no. 12. But press no. 1 button for few seconds and the channel will go to no. 1 channel.

2.3

Rear Panel

The following is the rear panel of the EDNS-3000 series system. The picture below is EDNS3000-16EP model.

Note

The configuration differs according to the model.

Page 10

3040-00052

DigiOpG2 Digital Video Recorder

No.

1

2

3

7

8

9

4

5

6

Camera Input (BNC)

LOOP OUT

MON OUT

Name

SPOT OUT

Power Input

Select NTSC / PAL

SENSOR Input

USB Port

LAN Port

10 S-Video Output

11 Serial Port

12 Audio Out

13 Audio In

14 Alarm Out / P/T/Z

Functions

Connect to Camera (supports NTSC/PAL)

Camera images of each channel will be outputted as is (also used when the corresponding image is required for other product)

Connect to the main monitor for camera image surveillance/management/playback

Use to output the entire surveillance screen one by one, in an interval

Connect main power cable

Select the signal system (NTSC/PAL)

Connect 16 external input sensors (supports N/O or N/C)

Connect USB device

RJ-45 socket for 10/100 Ethernet connection

Secondary main monitor output

RS-232C port

Connect Audio Output Device (with Amp.)

Connect Audio Input Device (with Amp.)

Connect P/T/Z receiver(RS-485) and/or relays

Note

Ensure that the specification for the EDNS-3000 agrees with the specification for the peripheral devices. For details about adding additional peripheral devices, consult your dealer.

Page 11

3040-00052

DigiOpG2 Digital Video Recorder

2.3.1.

Camera

Connect BNC plug of camera video cable into the desired BNC input.

Note

Camera input voltage level is 1Vp-p±10%.

2.3.2.

LOOP OUT

Use to apply the video of camera input to other device. Without using a video distributor, the same image can be connected to the camera input of other product.

2.3.3.

MON OUT

Connect the BNC cable of the monitor to MON OUT BNC cable of the rear panel.

2.3.4.

SPOT OUT

The spot monitor can only be used to display input images in automatic interval mode. Refer to “Settings” for automatic interval time setting of spot monitor.

2.3.5.

Power Input

Connect to main power cord of the system.

Caution

Before plugging-in the power cord to the system, check if the power is in accordance with the system specification (Single Phase AC 115~230V)

2.3.6.

Select NTSC / PAL

Turn off the power of the EDNS-3000 series and select the NTSC/PAL switch correctly. Then turn on the power again.

2.3.7.

SENSOR Input

Connect sensor (dry contact type). Separate the terminal block and wire all devices to desired pins, before connecting the terminal block again. Connect each ground (GND) line to “G” pins.

Note

Support both N/O (Normal Open) and N/C (Normal Close). If connected sensor is not functioning, ensure wiring is correct.

2.3.8.

USB Port

Connect USB storage device.

Note

Refer to “Image Backup” for details on the supported USB storage device of EDNS-3000.

2.3.9.

LAN Port

Connect RJ-45 jack of LAN cable to LAN port. Network has to be TCP/IP base 10/100BASE-TX Ethernet LAN (Local Area

Network), Internet or exclusive line, and IP address should be fixed one. Consult network administrator for proper network configuration.

2.3.10.

S-Video Output

One additional main monitor can be installed by using the S-Video output. Use the S-Video cable to connect the EDNS-3000 with the monitor, which has S-Video Input.

2.3.11.

Serial Port

Port for RS-232 signal output.

2.3.12.

Audio Out

Connect audio output equipment.

Note

Use of audio output device with an amplifier is recommended

2.3.13.

Audio In

Connect Audio Input device.

Note

Input voltage of audio input device is line level.

Use of audio output device with amplifier is recommended.

2.3.14.

Alarm Out / P/T/Z

Connect various alarm devices controlled by relay output. EDNS-3000 series supports RS-485 for P/T/Z control.

3040-00052

Page 12

DigiOpG2 Digital Video Recorder

Note

Refer to the following picture to control P/T/Z controller. General wiring of P/T/Z controllers is as follows. However, the wiring of different P/T/Z controller may differ. Be cautious that the P/T/Z controller will not function properly when wiring is incorrect.

Page 13

EDNS-3000

Consult your dealer to use other than RS-485.