6.10 Alarm-Output. ERNITEC DigiOpG2 EDNS3000 Series

Add to My manuals
51 Pages

advertisement

6.10 Alarm-Output. ERNITEC DigiOpG2 EDNS3000 Series | Manualzz

DigiOpG2 Digital Video Recorder

6.10

Alarm-Output

This is to set alarm actions regarding recording and relay output.

6.10.1.

Relay

Select the relay number to operate.

6.10.2.

Alarm Mode

Select either Set or Duration depending on the desired alarm action.

Set:

In this mode, the alarmed camera will be recorded (at the recording speed described in 6.9.1) during the setting time in Dwell tab from the moment sensor is activated. i.e. Sensor activation triggers alarm-activated recording, regardless of the deactivation of the sensor during alarm action.

Duration:

In this mode, the alarmed camera will be recorded (at the recording speed described in 6.9.1) upon sensor activation. i.e. The deactivation of the sensor stops the alarm-activated recording.

The corresponding relay will function in accordance with recording if the relay output is selected in the sensor, i.e. the relay starts when alarm-activated recording starts and ends when alarm-activated recording stops.

6.10.3.

Dwell

Set the period for which the alarmed camera will be recorded and the relay output is turned on. The recording stops and alarm output is turned off when the setting period is elapsed. Set the alarm-operating period (5~99 seconds).