01_XS1872_EN.fm Page 12 Thursday, September 25, 2008 8:31 PM
USING THE 1-HOUR OFF
TIMER
1. 1-Hour OFF Timer
ADJUSTING THE AIRFLOW
DIRECTION
The vertical airflow can be adjusted by moving the flap with the remote control unit. Do not move the flap with your hands. Confirm that the remote control unit has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.
This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed.
The operating.
indicator in the display indicates that this function is
Setting procedure:
Regardless of whether the unit is operating or stopped, press the 1
HR. TIMER button.
appears in the display.
Cancellation procedure:
Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again.
The 1-Hour Timer function is now cancelled and the unit operates normally.
NOTE
• If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.
• It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1
HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later.
2. Operation together with the daily ON/OFF repeat timer
The 1-Hour OFF Timer setting is given priority over the DAILY ON/
OFF REPEAT setting.
A. Sweep function
The flap starts moving up and down to deliver air over the sweep range.
B. Setting the airflow manually
Referring to the above illustration, use the
COOL
FLAP button to set the
DRY
airflow direction within the range used during cooling or dehumidifying operation.
SWEEP
C. Auto flap function
The flap is set to the recommended position.
NOTE
The flap automatically closes when the unit is off.
CAUTION
SWEEP
FAN
TIPS FOR ENERGY SAVING
Do not
• Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged.
• Let direct sunlight into the room. Use sunshades, blinds or curtains.
If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.
Do
• Always try to keep the air filter clean. (Refer to “CARE AND
CLEANING”.) A clogged filter will impair the performance of the unit.
• To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
• Use the FLAP button on the remote control to adjust the position of the flap. If you move the flap by hand, the flap position according to the remote control and the actual flap position may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again.
• Do not have the flap pointed down during cooling operation.
Condensation may begin to form around the air vent and drip down.
12 OI-108-12-EG
advertisement
Related manuals
advertisement
Table of contents
- 2 FEATURES
- 3 PRODUCT INFORMATION
- 3 ALERT SYMBOLS
- 3 INSTALLATION LOCATION
- 3 ELECTRICAL REQUIREMENTS
- 3 SAFETY INSTRUCTIONS
- 4 NAMES OF PARTS
- 8 USING THE REMOTE CONTROL UNIT
- 9 OPERATION WITH THE REMOTE CONTROL UNIT
- 9 1. Operation
- 9 2. Adjusting the Fan Speed
- 9 3. Fan Only
- 10 4. Night Setback Mode
- 10 5. HIGH POWER Mode
- 10 SPECIAL REMARKS
- 10 SETTING THE TIMER
- 12 USING THE 1-HOUR OFF TIMER
- 12 TIPS FOR ENERGY SAVING
- 12 ADJUSTING THE AIRFLOW DIRECTION
- 13 OPERATION WITHOUT THE REMOTE CONTROL UNIT
- 13 CARE AND CLEANING
- 15 TROUBLESHOOTING
- 15 OPERATING RANGE
- 15 WIRED REMOTE CONTROLLER