3.2.3

30

Status Codes

Technical Reference Manual

1MRS751251-MEN

Report Database and REPR Status Codes

1045

1046

1047

1048

1049

1050

1051

1052

1053

1054

1036

1037

1038

1039

1040

1042

1043

1044

1023

1024

1027

1028

1029

1033

1034

1035

1005

1007

1009

1012

1016

1019

1021

1022

REPF_END_OF_LIST

REPF_INDEX_TOO_HIGH

REPF_LR_TOO_HIGH

REPF_SOURCE_DOES_NOT_EXIST

REPF_UNKNOWN_ATTRIBUTE

REPF_NOT_A_COMMAND_PROCEDURE_ATTRIBUTE

REPF_ATTRIBUTE_NOT_WRITABLE

REPF_INVALID_REPORT_OBJECT_VALUE

REPF_EVENT_CHANNEL_OBJECTS_ARE_NOT_INDEXED

REPF_UNKNOWN_EVENT_CHANNEL_ATTRIBUTE

REPF_ON_ATTRIBUTE_TOO_LONG

REPF_ON_ATTRIBUTE_NON_TEXT

REPF_CM_ATTRIBUTE_NON_TEXT

REPF_UNKNOWN_DC_ATTRIBUTE

REPF_DC_ATTRIBUTE_NOT_INDEXED

REPF_NO_PS_ATTRIBUTE_IN_OBJECT

REPF_NO_SR_ATTRIBUTE_IN_OBJECT

REPF_UNKNOWN_TIME_CHANNEL_ATTRIBUTE

REPF_ATTRIBUTE_NOT_INDEXED

REPF_INDEX_OUT_OF_RANGE

REPF_NON_TEXT_COMMENT

REPF_ATTRIBUTE_MUST_BE_INDEXED

REPF_VECTOR_TOO_SHORT

REPF_SU_ATTRIBUTE_OUT_OF_RANGE

REPF_SU_ATTRIBUTE_NON_INTEGER

REPF_NON_TIME_SY_ATTRIBUTE

REPF_NEGATIVE_CY_ATTRIBUTE

REPF_NON_INTEGER_CY_ATTRIBUTE

REPF_NON_TEXT_CD_ATTRIBUTE

REPF_DC_OBJECT_TABLE_FULL

REPF_TIME_CHANNEL_TABLE_FULL

REPF_EVENT_CHANNEL_TABLE_FULL

REPF_EVENT_CHANNEL_DOES_NOT_EXIST

REPF_TIME_CHANNEL_DOES_NOT_EXIST

ABB Automation

1MRS751251-MEN

ABB Automation

1085

1086

1087

1088

1089

1090

1091

1077

1078

1079

1080

1081

1082

1083

1084

1064

1065

1066

1067

1068

1069

1070

1071

1072

1073

1074

1075

1076

1055

1057

1058

1059

1060

1061

1062

1063

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

REPF_DC_OBJECT_DOES_NOT_EXIST

REPF_ROD_DATA_DOES_NOT_EXIST

REPF_ROD_HISTORY_RECORD_DOES_NOT_EXIST

REPF_INVALID_OT_ATTRIBUTE_VALUE

REPF_INVALID_ON_ATTRIBUTE_VALUE

REPF_INVALID_CM_ATTRIBUTE_VALUE

REPF_BAD_EVENT_CHANNEL_ATTRIBUTE_STATUS

REPF_ON_ATTRIBUTE_MISSING

REPF_OT_ATTRIBUTE_MISSING

REPF_EVENT_CHANNEL_ALREADY_EXISTS

REPF_IU_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_IU_ATTRIBUTE_VALUE

REPF_BAD_TIME_CHANNEL_ATTRIBUTE_STATUS

REPF_INVALID_SY_SU_CY_OR_CD_ATTR_VALUE

REPF_INVALID_SY_ATTRIBUTE_VALUE

REPF_INVALID_SU_ATTRIBUTE_VALUE

REPF_INVALID_CY_ATTRIBUTE_VALUE

REPF_INVALID_CD_ATTRIBUTE_VALUE

REPF_TIME_CHANNEL_ALREADY_EXISTS

REPF_TIME_CHANNEL_NOT_EMPTY

REPF_EP_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_EP_ATTRIBUTE_VALUE

REPF_HR_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_HR_ATTRIBUTE_VALUE

REPF_LF_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_LF_ATTRIBUTE_VALUE

REPF_PS_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_PS_ATTRIBUTE_VALUE

REPF_INVALID_IN_ATTRIBUTE_VALUE

REPF_BAD_DC_OBJECT_ATTRIBUTE_STATUS

REPF_COMMAND_PROCEDURE_TOO_LONG

REPF_PS_ATTRIBUTE_MISSING

REPF_COPY_SOURCE_DOES_NOT_EXIST

REPF_SR_ATTRIBUTE_MISSING

REPF_DC_OBJECT_ALREADY_EXISTS

REPF_DATA_STORE_INVALID_INDEX

31

MicroSCADA

3 Status Codes

1121

1122

1123

1124

1125

1126

1113

1114

1115

1116

1117

1118

1119

1120

1100

1101

1102

1103

1104

1105

1106

1107

1108

1109

1110

1111

1112

1092

1093

1094

1095

1096

1097

1098

1099

Status Codes

Technical Reference Manual

REPF_DATA_STORE_OV_INVALID

REPF_DATA_STORE_OV_MISSING

REPF_DATA_STORE_RT_INVALID

REPF_DATA_STORE_OS_INVALID

REPF_CD_ATTRIBUTE_TOO_LONG

REPF_TS_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_TS_ATTRIBUTE_VALUE

REPF_PE_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_PE_ATTRIBUTE_VALUE

REPF_PQ_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_PQ_ATTRIBUTE_VALUE

REPF_MO_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_MO_ATTRIBUTE_VALUE

REPF_HN_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_HN_ATTRIBUTE_VALUE

REPF_SE_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_SE_ATTRIBUTE_VALUE

REPF_APPLICATION_CLOSE_TIMEOUT

REPF_SX_ATTRIBUTE_OUT_OF_RANGE

REPF_INVALID_SX_ATTRIBUTE_VALUE

REPF_OBJECT_IS_LOCKED

REPF_HISTORY_PAGE_TABLE_FULL

REPF_VERSION_NUMBER_MISMATCH

REPF_RDB_HEADER_INCONSISTENT

REPF_INCONSISTENT_DATA_RECORD

REPF_MEMORY_EXHAUSTED

REPF_EXECUTION_QUEUE_FULL

REPF_OBJECT_NOT_IN_USE

REPF_INVALID_ST_ATTRIBUTE_VALUE

REPF_INVALID_SN_ATTRIBUTE_VALUE

REPF_SN_ATTRIBUTE_MISSING

REPF_ST_ATTRIBUTE_MISSING

REPF_INVALID_TC_ATTRIBUTE_VALUE

REPF_INVALID_CP_ATTRIBUTE_VALUE

REPF_INVALID_FI_ATTRIBUTE_VALUE

FI is not an integer.

32

1MRS751251-MEN

ABB Automation

advertisement

Key Features

  • Lists all MicroSCADA status codes
  • Provides explanations of the codes
  • Divides codes into groups
  • Covers base system and NET units
  • Technical reference manual

Related manuals

Frequently Answers and Questions

What is the purpose of the MicroSCADA Status Codes?
Status codes are used to indicate the reliability of data, inform about errors during SCIL program execution, and communicate events in the process communication system or communication units.
How are status codes grouped?
Status codes are grouped into categories: reliability of data, base system status codes, NET status codes, operating system status codes, data transfer status codes, and status codes transmitted by a NET unit to external devices.
What is the OK status code?
The OK status code is 0, indicating that no error has occurred.
What is the difference between almost OK status codes and error codes?
Almost OK status codes (1, 2, 3) indicate a warning or uncertain value that can be used in expressions but may result in a non-zero status. Error codes (10 .. 10 000) are used for errors in the system.