3.2.13 DECNET Status Codes. ABB MicroSCADA

Add to My manuals
212 Pages

MicroSCADA Status Codes is a technical reference manual that lists all MicroSCADA status codes. It provides explanations of the codes and their possible causes, and divides them into groups based on their relation to the base system or communication and NET units.

advertisement

3.2.13 DECNET Status Codes. ABB MicroSCADA | Manualzz

MicroSCADA

3 Status Codes

3.2.13

3.2.14

3.2.15

66

Status Codes

Technical Reference Manual

1MRS751251-MEN

8101

8102

8103

8104

8105

8106

8107

8108

8109

8110

8111

8112

MIIF_TOO_MANY_ARGUMENTS

MIIF_INVALID_LINE_NUMBER

MIIF_INVALID_COLUMN_NUMBER

MIIF_INVALID_VARIABLE_NAME

MIIF_INVALID_INPUT

MIIF_INVALID_PROMPT

MIIF_FILE_OPEN_ERROR

MIIF_FILE_READ_ERROR

MIIF_FILE_CREATE_ERROR

MIIF_FILE_APPEND_ERROR

MIIF_FILE_WRITE_ERROR

MIIF_FILE_CLOSE_ERROR

DECNET Status Codes

8201

8202

8203

8204

8205

DNPC_DECNET_COMMUNICATION_INIT_FAILED

DNPC_DECNET_LINK_ABORTED

DNPC_DECNET_CONNECTION_REQUEST_FAILED

DNPC_DECNET_TRANSMIT_IO_FAILED

DNPC_DECNET_TRANSMIT_QIO_FAILED

TCP/IP Status Codes

8801

8802

8803

8804

8805

8806

8807

8808

8301

8302

8303

8304

8305

8306

INPC_TCPIP_COMMUNICATION_INIT_FAILED

INPC_TCPIP_LINK_ABORTED

INPC_TCPIP_CONNECTION_REQUEST_FAILED

INPC_TCPIP_TRANSMIT_IO_FAILED

INPC_TCPIP_TRANSMIT_QIO_FAILED

INPC_TCPIP_UNKNOWN_HOST

Stand-alone Frontend (MFEL) Status Codes

MFEL_NO_FREE_BUFFERS

MFEL_UNKNOWN_DESTINATION_NODE

MFEL_INDEX_RANGE_ERROR

MFEL_ATTRIBUTE_ACCESS_RIGHT_CONFLICT

MFEL_INVALID_ATTRIBUTE_VALUE

MFEL_TIME_SETTING_FAILED

MFEL_LINK_NOT_DEFINED

MFEL_SYS_CONNECTION_SUSPENDED

ABB Automation

advertisement

Key Features

  • Lists all MicroSCADA status codes
  • Provides explanations of the codes
  • Divides codes into groups
  • Covers base system and NET units
  • Technical reference manual

Related manuals

Frequently Answers and Questions

What is the purpose of the MicroSCADA Status Codes?
Status codes are used to indicate the reliability of data, inform about errors during SCIL program execution, and communicate events in the process communication system or communication units.
How are status codes grouped?
Status codes are grouped into categories: reliability of data, base system status codes, NET status codes, operating system status codes, data transfer status codes, and status codes transmitted by a NET unit to external devices.
What is the OK status code?
The OK status code is 0, indicating that no error has occurred.
What is the difference between almost OK status codes and error codes?
Almost OK status codes (1, 2, 3) indicate a warning or uncertain value that can be used in expressions but may result in a non-zero status. Error codes (10 .. 10 000) are used for errors in the system.