3.2.16 Operating System Status Codes. ABB MicroSCADA

Add to My manuals
212 Pages

MicroSCADA Status Codes is a technical reference manual that lists all MicroSCADA status codes. It provides explanations of the codes and their possible causes, and divides them into groups based on their relation to the base system or communication and NET units.

advertisement

3.2.16 Operating System Status Codes. ABB MicroSCADA | Manualzz

1MRS751251-MEN

3.2.16

3.3

3.3.1

3.3.2

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

8809 MFEL_CONNECTION_IN_PROGRESS

Operating System Status Codes

9000 UNIX_BASE_STATUS

9001..9199 UNIX_STATUS_CODES

The code minus 9000 is a UNIX error code

9200 RMX_BASE_STATUS

NET Status Codes

Common NET Status Codes

10500

10501

10502

10503

10504

10505

10506

10507

10508

10509

10001

10002

10003

10004

10005

NETP_SYSTEM_INITIALIZED

NETP_IU_ATRIBUTE_WAS_EXPECTED

The base system and the frontend do not communicate properly with each other. Contact an ABB representative.

NETP_TIMEOUT_WHILE_WAITING_ACKNOWLEDGE

The base system and the frontend do not communicate properly with each other. Contact an ABB representative.

NETP_UNKNOWN_CONFIGURATION_OBJECT

NETP_UNKNOWN_SCM_FUNCTION

The base system and the fron-endt do not communicate properly with each other. Contact an ABB representative.

10006

10007

10008

10009

NETP_OUT_OF_MEMORY

NETP_CONFLICT_IN_PRECONFIGURATION

NETP_PROTOCOL_NOT_SUPPORTED

NETP_NAME_IS_LOGICAL_OR_UNDEFINED

Redundant Frontend Status Codes

REFP_NO_REPLY_FROM_STANDBY_FE

REFP_NO_REPLY_FROM_HOT_FE

REFP_NO_BUFFER

REFC_HOT_FE_NOT_RESPONDING

REFC_UNDEFINED_PEER_NODE

REFC_INVALID_PEER_NODE_NUMBER

REFC_INVALID_RUNNING_MODE

REFC_INVALID_SHADOWING_MODE

REFC_TRANSFER_DATA_LENGTH_MISMATCH

REFC_INVALID_TRANSFER_DATA_ID

67

MicroSCADA

3 Status Codes

3.3.3

68

Status Codes

Technical Reference Manual

1MRS751251-MEN

11025

11026

11027

11028

11029

11030

11031

11017

11018

11019

11020

11021

11022

11023

11024

11001

11002

11003

11005

11006

11007

11009

11010

11011

11012

11014

11015

11016

10510

10511

10512

10513

10514

REFC_SC_DATA_OVERFLOW

REFC_INVALID_INDEX_RANGE

REFC_INVALID_SH_AND_RM_VALUE_COMBINATION

REFP_PEER_HAS_LOST_APL_CONNECTION

REFC_INITIALIZATION_NOT_COMPLETE

Errors in Message Structure NET - Basesystem

BUFMS_BINARY_TYPE_EXPECTED

BUFMS_BUFFER_OVERFLOW

BUFMS_CHARACTER_TYPE_EXPECTED

BUFMS_SIGNED_16_OUT_OF_RANGE

BUFMS_SIGNED_16_TYPE_EXPECTED

BUFMS_SIGNED_32_TYPE_EXPECTED

BUFMS_TIMESTAMP_ITEM_EXPECTED

BUFMS_UNKNOWN_DATA_TYPE

BUFMS_UNSIGNED_16_OUT_OF_RANGE

BUFMS_UNSIGNED_16_TYPE_EXPECTED

BUFMS_UNSIGNED_8_OUT_OF_RANGE

BUFMS_UNSIGNED_8_TYPE_EXPECTED

BUFMS_ZERO_LENGTH_DATA_ARRAY

The base system and the frontend do not communicate properly. Contact an ABB representative.

BUFMS_BIT_VALUE_TYPE_EXPECTED

BUFMS_FULL_TIMESTAMP_TYPE_EXPECTED

BUFMS_ADDRESS_TYPE_EXPECTED

BUFMS_BIT_STREAM_TYPE_EXPECTED

BUFMS_SIGNED_8_OUT_OF_RANGE

BUFMS_SIGNED_8_TYPE_EXPECTED

BUFMS_SIGNED_32_OUT_OF_RANGE

BUFMS_UNSIGNED_32_OUT_OF_RANGE

BUFMS_UNSIGNED_32_TYPE_EXPECTED

BUFMS_FLOAT_32_TYPE_EXPECTED

BUFMS_EXTENDED_ADDRESS_TYPE_EXPECTED

BUFMS_SIGNED_64_OUT_OF_RANGE

BUFMS_SIGNED_64_TYPE_EXPECTED

BUFMS_UNSIGNED_64_OUT_OF_RANGE

BUFMS_UNSIGNED_64_TYPE_EXPECTED

ABB Automation

1MRS751251-MEN

3.3.4

3.3.5

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

11032 BUFMS_FLOAT_64_TYPE_EXPECTED

Common NET Application Layer Status Codes

12101

12102

12103

12104

12105

12106

12002

12003

12004

12006

12007

12008

12010

12011

APPL_DEVICE_ALREADY_RESERVED

The device is occupied by another MicroSCADA process.

APPL_DEVICE_ATTRIBUTE_NOT_CHANGEABLE

APPL_DEVICE_NOT_RESERVED

APPL_ILLEGAL_SOURCE_FOR_GIVEN_CMD

The sender has not the right to give the command in question.

APPL_MESSAGE_BUFFER_OVERFLOW

APPL_INVALID_VALUE_FOR_CHOSEN_ATTRIBUTE

APPL_NONEXISTENT_DEVICE_ATTRIBUTE

APPL_UNKNOWN_COMMAND_SOURCE

The sender of the command is unknown.

12012

12013

12014

12015

12016

12017

12018

12019

12020

12021

12022

APPL_RELEASE_CMD_FROM_WRONG_PROCESS

APPL_INVALID_AL_ATTRIBUTE_VALUE

APPL_INVALID_MI_ATTRIBUTE_VALUE

APPL_INVALID_MS_ATTRIBUTE_VALUE

APPL_INVALID_MI_ATTRIBUTE_INDEX

APPL_INVALID_ED_INDEX

APPL_UNKNOWN_ED_TRANSLATION

APPL_DATA_TYPE_OVERFLOW

APPL_INVALID_AS_ATTRIBUTE_VALUE

APPL_UNKNOWN_EDEV_DEVICE_TYPE

APPL_INVALID_MS_ATTRIBUTE_INDEX

System Process Status Codes

SYSC_REPLY_MESSAGE_TIMEOUT

SYSC_SCM_DATA_IGNORED

SYSC_UNDEFINED_SYS_CONNECTION

SYSC_INVALID_RT_ATTRIBUTE_VALUE

SYSC_INVALID_SU_ATTRIBUTE_VALUE

SYSC_STATION_NOT_DEFINED_IN_BASE_SYSTEM

ABB Automation

69

MicroSCADA

3 Status Codes

3.3.6

3.3.7

70

Status Codes

Technical Reference Manual

1MRS751251-MEN

NET device errors in NET

12306

12307

12308

12309

12310

12311

12317

12318

12319

12320

12321

12322

12323

ANSI Station Status Codes

12301

12302

12303

12304

12305

12312

12314

12315

12316

12324

12325

12326

STAC_AB_DATA_ITEM_OVERFLOW

STAC_AB_DATA_OVERFLOW

STAC_ATTRIBUTE_IS_READ_ONLY

STAC_ATTRIBUTE_IS_WRITE_ONLY

STAC_COMMAND_AND_DATA_TYPE_IN_CONFLICT

The command type (read/write) is not allowed for the chosen memory area.

STAC_COMMAND_NOT_IMPLEMENTED

STAC_DIAGNOSTIC_CT_RESET_DATA_ERROR

STAC_DIAGNOSTIC_LOOP_TEST_DATA_ERROR

STAC_DOWNLOAD_NOT_IMPLEMENTED

STAC_FUNCTION_NOT_IMPLEMENTED

STAC_ILLEGAL_DIGIT_IN_BCD_NUMBER

Undefined or incorrectly defined memory area.

STAC_ILLEGAL_MESSAGE_LENGTH

STAC_ILLEGAL_PLC2_COMMAND_CODE

STAC_ILLEGAL_SC_DATA_TYPE_COMBINATION

Analog and digital data cannot be included in the same message.

STAC_INDEX_RANGE_CROSSES_RUNG_BOUNDARY

A read or write command refers to an address area which is not totally within the same memory area.

STAC_INTERNET_COMM_NOT_IMPLEMENTED

STAC_MEMORY_RUNG_DEFINITION_ERROR

STAC_NONCONTIGOUS_BIT_WRITE_MEMORY_AREA

STAC_NO_MEMORY_RUNG_CHOSEN_FOR_READ_DATA

STAC_PLC2_DATA_CODE_NOT_IMPLEMENTED

STAC_SC_DATA_OVERFLOW

STAC_SC_TO_AB_ITEM_TYPE_INCOMPATIBILITY

The data elements of the SCM message can not be transformed according to the memory area code attribute.

STAC_UNDEFINED_PLC2_MEMORY_ADDRESS

STAC_UNKNOWN_DESTINATION_STATION

STAC_UNKNOWN_LOGICAL_DESTINATION

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

12336

12337

12338

12339

12340

12327

12328

12329

12330

12332

12333

12334

12335

12341

12342

12343

12344

12345

12346

12347

12348

12349

12350

12351

12352

STAC_UNKNOWN_LOGICAL_SOURCE

STAC_UNKNOWN_SOURCE_STATION

STAC_ZERO_LENGTH_DATA_ARRAY

STAP_AB_SC_CONVERSION_ERROR

The message can not be transformed from the form used in the RTU to the one used by the main program (SCM).

STAP_ILLEGAL_AB_COMMAND_DESTINATION

STAP_STATION_LINE_ERROR

The CTS or the DCD line of the RS232 connection is inactive. The cable is uncoupled, the hand shaking signals are uncorrectly coupled or the modem is uncorrectly coupled.

STAP_REPLY_TIMEOUT

STAP_SC_AB_CONVERSION_ERROR

The message can not be transformed from the form used by the main program (SCM) to the one used by the RTU (ABM).

STAP_SIGNAL_QUEUE_EMPTY

STAP_STATION_SUSPENDED

The RTU is suspended. The reason may be:

STAP_STATION_SUSPENDED_AND_LINE_ERROR

The error situations 12333 and 12337 have occurred simultaneously.

STAP_STOPPED

The IU attribute of the station is 0 (not in use).

STAC_ILLEGAL_OCTAL_BCD_DIGIT

The memory address appearing in a spontaneous message does not follow the coding way chosen in the memory area definition (the attribute BF).

STAC_INVALID_AD_ATTRIBUTE_VALUE

STAC_INVALID_AT_ATTRIBUTE_VALUE

STAC_INVALID_BF_ATTRIBUTE_VALUE

STAC_INVALID_CO_ATTRIBUTE_VALUE

STAC_INVALID_DI_ATTRIBUTE_VALUE

STAC_INVALID_DT_ATTRIBUTE_VALUE

STAC_INVALID_LE_ATTRIBUTE_VALUE

STAC_INVALID_MEMORY_RUNG_NUMBER

STAC_INVALID_MR_ATTRIBUTE_VALUE

STAC_INVALID_PH_ATTRIBUTE_VALUE

STAC_INVALID_RT_ATTRIBUTE_VALUE

STAC_INVALID_SE_ATTRIBUTE_VALUE

71

MicroSCADA

3 Status Codes

72

Status Codes

Technical Reference Manual

1MRS751251-MEN

12373

12374

12375

12376

12377

12378

12379

12380

12381

12382

12365

12366

12367

12368

12369

12370

12371

12372

12353

12354

12355

12357

12358

12359

12360

12361

12362

12383

12384

12385

12386

12387

12388

12389

STAC_INVALID_SU_ATTRIBUTE_VALUE

STAC_INVALID_TS_ATTRIBUTE_VALUE

STAC_UNKNOWN_MEMORY_RUNG

STAC_MEMORY_RUNG_ALREADY_EXISTS

STAC_UNKNOWN_STA_ATTRIBUTE

STAC_DIAGNOSTIC_CMD_TRANSMISSION_ERROR

STAC_INVALID_DE_ATTRIBUTE_VALUE

STAC_STATION_RESERVED_BY_OTHER_SYSTEM

STAC_MEMORY_ALLOCATION_FAILED

Memory reservation does not succeed. Contact an ABB representative.

STAC_INVALID_FS_ATTRIBUTE_VALUE

STAC_UNKNOWN_DIAGNOSTIC_COUNTER

STAC_INVALID_INDEX_RANGE

STAP_SUSPENSIVE_STATUS_IN_REPLY_MSG

STAC_PLC_IN_PROGRAM_LOAD_MODE

STAC_PLC_IN_TEST_MODE

STAC_PLC_IN_REMOTE_PROGRAM_LOAD_MODE

STAC_PLC_IN_REMOTE_TEST_MODE

STAC_PLC_IN_DOWNLOAD_MODE

STAC_UNKNOWN_PLC_MODE

STAC_ERROR_IN_PLC_PROG_COMM_ZONE

STAC_NO_INTERFACE_PLC_PROCESSOR_COMM

STAC_PLC_SHUTDOWN_IN_EFFECT

STAC_PLC_SHUTDOWN_REQUESTED

STAC_MAJOR_PLC_PROCESSOR_FAULT

STAC_UNKNOWN_COMMUNICATION_INTERFACE_TYPE

STAC_INVALID_DIAGNOSTIC_STATUS

STAC_SPLIT_PROCESS_DOES_NOT_EXIST

The SPLIT function has not been activated for the station in question.

STAC_PROGRAM_CASE_ERROR

STAC_INVALID_SP_ATTRIBUTE_VALUE

STAC_INVALID_WORD_ADDRESS

STAP_REPLY_TX_FAILURE

STAC_INVALID_CP_ATTRIBUTE_VALUE

STAC_READ_SIZE_OVERFLOW

STAC_INVALID_MC_ATTRIBUTE_VALUE

ABB Automation

1MRS751251-MEN

3.3.8

3.3.9

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

12390

12391

12392

12393

12394

12395

STAC_ORIGINAL_STATION_DOES_NOT_EXIST

STAC_ORIGINAL_MEMORY_AREA_DOES_NOT_EXIST

STAC_AB_DATA_LENGTH_MISMATCH

STAC_AB_DATA_TYPE_MISMATCH

STAC_ITEM_ADDRESS_OVERFLOW

STAC_READ_SIZE_MISMATCH

Mismatch in the read reply data length.

12396

12397

12399

STAC_INVALID_ST_ATTRIBUTE_VALUE

STAC_TIMESYNC_MEMORY_AREA_NOT_DEFINED

STAC_INVALID_TIMESTAMP_RECEIVED

ANSI Station Message SPLIT Status Codes

12401

12402

12403

12404

12405

12406

12407

STMC_NON_VALID_SPLIT_REPLY

STMP_SPLIT_ORIG_DEST_FAIL

Failed to send the message to the stations defined in the RTU.

STMP_SPLIT_SEC_DEST_FAIL

Failed to send the message to the receivers of the SPLIT message defined in NET.

STMP_SPLIT_TOTAL_FAIL

The message was not successfully sent to any receiving station.

STMC_SPLIT_ORIG_DEST_FAIL

Sending of the message to the target station defined in the RTU did not succeed.

STMC_SPLIT_SEC_DEST_FAIL

Failed to send the message to the receivers of the SPLIT message defined in NET.

STMC_SPLIT_TOTAL_FAIL

The message was not successfully sent to any receiving station.

12408

12409

12410

STMC_SPLIT_NEAR_SEC_DEST_FAIL

STMC_SPLIT_NEAR_TOTAL_FAIL

STMC_SEC_OK_STATUS

SINDAC ADLP180 Status Codes

12450

12451

12453

12454

SIDC_INVALID_INDEX_RANGE

SIDC_ILLEGAL_ATTRIBUTE_VALUE

SIDC_UNKNOWN_DIAGNOSTIC_COUNTER

SIDC_SC_DATA_OVERFLOW

73

MicroSCADA

3 Status Codes

3.3.10

74

Status Codes

Technical Reference Manual

1MRS751251-MEN

12501

12502

12503

12504

12505

12506

12463

12464

12465

12466

12467

12468

12469

12470

12455

12456

12457

12458

12459

12460

12461

12462

12471

12472

12474

12475

12480

12481

12482

12483

12484

12485

12486

12487

SINDAC Status Codes

SIDC_UNKNOWN_SID_ATTRIBUTE

SIDC_TEV_BUFFER_OVERFLOW

SIDC_UNKNOWN_FNC_RECEIVED

SIDC_INVALID_FNC_RECEIVED

SIDC_FCOM_COLDSTART_RECEIVED

SIDC_UNKNOWN_FCOM_RECEIVED

SIDC_ILLEGAL_FCOM_RECEIVED

SIDC_CBXC_RECEIVED

SIDC_IHC_RECEIVED

SIDC_IHC_FAILED

SIDC_EXC_FAILED

SIDC_ERMI_BUFFER_OVERFLOW

SIDC_PREV_PC_VALUE_NOT_YET_REPORTED

SIDC_PULSECOUNTER_IS_BLOCKED

SIDC_ARGUMENT_EXPECTED

SIDC_TOO_MANY_ARGUMENTS

SIDC_NOT_ACTIVE_OR_NO_FTAB_LOADED

SIDC_FCOM_ACTIVATE_RECEIVED

SIDC_UNKNOWN_FTAB_RECEIVED

SIDC_POINT_NOT_INITIALIZED_WHILE_DI_0

SIDP_CBXC_RECEIVED

SIDP_IHC_RECEIVED

SIDP_EXC_FAILED

SIDP_ILLEGAL_FNC_RECEIVED

SIDP_COMMUNICATION_WITH_CS_LOST

SIDP_COMMUNICATION_WITH_CS_ESTABLISHED

SIDP_UNIMPLEMENTED_FNC_RECEIVED

SIDP_UNABLE_TO_ALLOCATE_MEMORY

SINC_AD_DATA_ITEM_OVERFLOW

SINC_AD_DATA_OVERFLOW

SINC_ATTRIBUTE_IS_READ_ONLY

SINC_ATTRIBUTE_IS_WRITE_ONLY

SINC_COMMAND_AND_DATA_TYPE_IN_CONFLICT

SINC_COMMAND_NOT_IMPLEMENTED

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

12562

12566

12567

12568

12580

12581

12585

12542

12543

12544

12550

12556

12557

12558

12559

12517

12518

12521

12522

12523

12525

12526

12527

12507

12508

12509

12510

12512

12514

12515

12516

12528

12529

12539

12540

12541

SINC_DIAGNOSTIC_CT_RESET_DATA_ERROR

SINC_DIAGNOSTIC_LOOP_TEST_DATA_ERROR

SINC_DOWNLOAD_NOT_IMPLEMENTED

SINC_FUNCTION_NOT_IMPLEMENTED

SINC_ILLEGAL_MESSAGE_LENGTH

SINC_ILLEGAL_SINDAC_COMMAND_CODE

SINC_ILLEGAL_SC_DATA_TYPE_COMBINATION

SINC_INDEX_RANGE_CROSSES_PRIORITY_BOUNDARY

SINC_INTERNET_COMM_NOT_IMPLEMENTED

SINC_MEMORY_DEFINITION_ERROR

SINC_EVENT_BUFFER_OVERFLOW

SINC_SC_DATA_OVERFLOW

SINC_SC_TO_AD_ITEM_TYPE_INCOMPATIBILITY

SINC_UNKNOWN_DESTINATION_STATION

SINC_UNKNOWN_LOGICAL_DESTINATION

SINC_UNKNOWN_LOGICAL_SOURCE

SINC_UNKNOWN_SOURCE_STATION

SINC_ZERO_LENGTH_DATA_ARRAY

SINP_STOPPED

SINP_SCI_RECEIVED

SINP_CBXC_RECEIVED

SINP_IHC_RECEIVED

SINP_EXC_FAILED

SINP_IHC_FAILED

SINC_NO_PENDING_EVENTS

SINC_ILLEGAL_ATTRIBUTE_VALUE

SINC_ILLEGAL_SIN_ATTRIBUTE

SINC_UNKNOWN_SIN_ATTRIBUTE

SINC_DIAGNOSTIC_CMD_TRANSMISSION_ERROR

SINC_MEMORY_ALLOCATION_FAILED

SINC_UNKNOWN_DIAGNOSTIC_COUNTER

SINC_INVALID_INDEX_RANGE

SINC_INVALID_CONFIGURATION

SINC_UNKNOWN_COMMUNICATION_INTERFACE_TYPE

SINC_INVALID_DIAGNOSTIC_STATUS

SINC_INVALID_WORD_ADDRESS

75

MicroSCADA

3 Status Codes

3.3.11

76

Status Codes

Technical Reference Manual

1MRS751251-MEN

RTU 200 Status Codes

12625

12626

12627

12628

12629

12630

12651

12652

12653

12654

12617

12618

12619

12620

12621

12622

12623

12624

12609

12610

12611

12612

12613

12614

12615

12616

12601

12602

12603

12604

12605

12606

12607

12608

RTUP_UNEXPECTED_RESPONSE

RTUP_DEVICE_SUSPENDED

RTUP_TIMEOUT_WHILE_WAITING_RESPONSE

RTUP_DEVICE_STOPPED

RTUP_DEVICE_STARTED

RTUP_STATUS_CHECK_REQUESTED

RTUP_TOTAL_BROADCAST_FAILURE

RTUP_PARTIAL_BROADCAST_FAILURE

RTUP_FAILED_TO_INITIALIZE_BC_TELEGRAM

RTUP_BROADCAST_SUCCESSFULL

RTUP_SB_TRANSFER_NOT_CONFIRMED

RTUS_SUB_RTU_DOES_NOT_EXIST

RTUS_SUB_RTU_DOES_NOT_ANSWER

RTUS_OUT_OF_SERVICE

RTUS_UNEXPECTED_ANSWER_FROM_SUB_RTU

RTUS_NEXT_LEVEL_ROUTER_DOES_NOT_ANSWER

RTUS_NEXT_LEVEL_ROUTER_OUT_OF_SERVICE

RTUS_UNEXPECTED_ANSWER_FROM_NEXT_ROUTER

RTUS_COMMAND_BUFFER_OVERFLOW

RTUS_SUB_RTU_COMLINE_INOPERABLE

RTUS_THIS_ROUTER_IS_DEACTIVATED

RTUS_COMMAND_TO_SUB_RTU_IS_ACTIVE

RTUS_INTERNAL_ERROR_23ZG20

RTUS_INTERNAL_ERROR_23LK20

RTUS_COMM_LOST_WITH_OTHER_CC

RTUS_COMM_OK_WITH_OTHER_CC

RTUS_SYNCHRONIZED_FROM_THIS_CC

RTUS_NOT_SYNCHRONIZED_FROM_THIS_CC

RTUS_FTAB_LOADED_FROM_THIS_CC

RTUS_FTAB_NOT_LOADED_FROM_THIS_CC

RTUC_UNKNOWN_DIAGNOSTIC_COUNTER

RTUC_INVALID_RT_ATTRIBUTE_VALUE

RTUC_SC_DATA_OVERFLOW

RTUC_INVALID_TAG_NUMBER

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

12684

12685

12686

12687

12688

12689

12690

12676

12677

12678

12679

12680

12681

12682

12683

12663

12664

12665

12666

12667

12668

12669

12670

12655

12656

12657

12658

12659

12660

12661

12662

12671

12672

12673

12674

12675

RTUC_TAGGED_EVENT_NOT_FOUND

RTUC_TAGGED_MESSAGE_NOT_FOUND

RTUC_UNKNOWN_RTU_ATTRIBUTE

RTUC_INVALID_INDEX_RANGE

RTUC_INVALID_IDENT_NUMBER

RTUC_INVALID_SE_ATTRIBUTE_VALUE

RTUC_ILLEGAL_APPLICATION_FOR_OPERATION

RTUC_ATTRIBUTE_IS_WRITE_ONLY

RTUC_ONLY_CHARACTER_ARRAYS_ALLOWED

RTUC_ILLEGAL_LENGTH_FOR_TD

RTUC_NOT_EXECUTED_RESPONSE

RTUC_UNEXPECTED_RESPONSE

RTUC_INVALID_FCOM_NUMBER

RTUC_FCOM_NUMBER_NOT_USED

RTUC_NOT_ENOUGH_INFO_FOR_FCOM

RTUC_ILLEGAL_FCOM_INFO

RTUC_TERMINAL_STATUS_OVERFLOW

RTUC_EVENT_RECORDING_MESSAGES_LOST

RTUC_ONLY_WRITE_IS_POSSIBLE

RTUC_ILLEGAL_OBJECT_TYPE

RTUC_ILLEGAL_OBJECT_ADDRESS

RTUC_UNEXPECTED_VALUE

RTUC_UNEXPECTED_COMMAND_TYPE

RTUC_ILLEGAL_LENGTH_FOR_FT

RTUC_DEVICE_MUST_BE_ALLOCATED

RTUC_RTU_ADDRESS_NOT_CONFIGURED

RTUC_INVALID_SC_ATTRIBUTE_VALUE

RTUC_ILLEGAL_BROADCAST_ACTION

RTUC_TRANSPARENT_DATA_PENDING

RTUC_TRANSPARENT_DATA_OVERFLOW

RTUC_NO_TRANSPARENT_DATA_PENDING

RTUC_TRANSFER_DATA_LENGTH_MISMATCH

RTUC_MEMORY_ALLOCATION_FAILED

RTUC_ROUTER_RTU_ADDRESS_NOT_FOUND

RTUC_INVALID_HR_ATTRIBUTE_VALUE

RTUC_INVALID_SM_ATTRIBUTE_VALUE

MicroSCADA

3 Status Codes

77

MicroSCADA

3 Status Codes

3.3.12

78

Status Codes

Technical Reference Manual

12691

12692

12693

RTUC_INVALID_TA_ATTRIBUTE_VALUE

RTUC_CANNOT_GET_MESSAGE_BUFFER

RTUC_INVALID_TA_ATTRIBUTE_INDEX

RTU 200 Terminal Status Codes

12725

12726

12727

12728

12729

12730

12731

12717

12718

12719

12720

12721

12722

12723

12724

12709

12710

12711

12712

12713

12714

12715

12716

12701

12702

12703

12704

12705

12706

12707

12708

RTUS_INDICATION_FAULTY

RTUS_INDICATION_OK

RTUS_ANALOG_VALUE_FAULTY

RTUS_ANALOG_VALUE_OK

RTUS_DIGITAL_VALUE_FAULTY

RTUS_DIGITAL_VALUE_OK

RTUS_PULSE_COUNTER_FAULTY

RTUS_PULSE_COUNTER_OK

RTUS_COMMAND_OUTPUT_FAULTY

RTUS_COMMAND_OUTPUT_OK

RTUS_SETPOINT_OUTPUT_FAULTY

RTUS_SETPOINT_OUTPUT_OK

RTUS_GENERAL_OUTPUT_FAULTY

RTUS_GENERAL_OUTPUT_OK

RTUS_RTU_FAULTY

RTUS_RTU_OK

RTUS_RTU_ACTIVE

RTUS_RTU_NOT_ACTIVE

RTUS_RTU_SYNCHRONIZED

RTUS_RTU_NOT_SYNCHRONIZED

RTUS_EXTERNAL_CLOCK_INOPERABLE

RTUS_EXTERNAL_CLOCK_OPERABLE

RTUS_LOCAL_PRINTER_OFFLINE

RTUS_LOCAL_PRINTER_ONLINE

RTUS_COMMAND_OUTPUTS_BLOCKED

RTUS_COMMAND_OUTPUTS_DEBLOCKED

RTUS_AC_FAILURE

RTUS_AC_OK

RTUS_BATTERY_LOW

RTUS_BATTERY_OK

RTUS_LOCAL_PRINTER_FAILURE

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

12761

12762

12763

12764

12765

12766

12767

12753

12754

12755

12756

12757

12758

12759

12760

12740

12741

12742

12743

12744

12745

12746

12747

12732

12733

12734

12735

12736

12737

12738

12739

12748

12749

12750

12751

12752

RTUS_LOCAL_PRINTER_OK

RTUS_RWM_BATTERY_FAULTY

RTUS_RWM_BATTERY_OK

RTUS_PLAIN_TEXTS_LOADED

RTUS_PLAIN_TEXTS_NOT_LOADED

RTUS_BACKUP_FOR_PLAIN_TEXTS_FAULTY

RTUS_BACKUP_FOR_PLAIN_TEXTS_OK

RTUS_PROCESS_VOLTAGE_FAULTY

RTUS_PROCESS_VOLTAGE_OK

RTUS_LOCAL_WARNING

RTUS_END_OF_LOCAL_WARNING

RTUS_SUBORDINARE_RTU_IS_INOPERABLE

RTUS_SUBORDINARE_RTU_IS_OPERABLE

RTUS_SUBORDINARE_RTU_IS_OUT_OF_SERVICE

RTUS_SUBORDINARE_RTU_IS_INSERVICE

RTUS_HOST1_IS_DISCONNECTED

RTUS_HOST1_IS_CONNECTED

RTUS_HOST2_IS_DISCONNECTED

RTUS_HOST2_IS_CONNECTED

RTUS_HOST3_IS_DISCONNECTED

RTUS_HOST3_IS_CONNECTED

RTUS_HOST1_IS_PRIMARY_HOST

RTUS_HOST2_IS_PRIMARY_HOST

RTUS_HOST3_IS_PRIMARY_HOST

RTUS_YOU_ARE_PRIMARY_HOST

RTUS_YOU_ARE_NOT_PRIMARY_HOST

RTUS_SUBORD_RTU_LINE_1_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_1_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_2_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_2_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_3_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_3_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_4_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_4_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_5_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_5_IS_OPERABLE

MicroSCADA

3 Status Codes

79

MicroSCADA

3 Status Codes

3.3.13

80

Status Codes

Technical Reference Manual

12801

12802

12803

12804

12805

12806

12807

12808

12809

12810

12811

12812

12776

12777

12778

12779

12780

12781

12782

12783

12784

12785

12786

12787

12788

12789

12768

12769

12770

12771

12772

12773

12774

12775

RTUS_SUBORD_RTU_LINE_6_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_6_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_7_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_7_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_8_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_8_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_9_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_9_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_10_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_10_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_11_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_11_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_12_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_12_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_13_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_13_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_14_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_14_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_15_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_15_IS_OPERABLE

RTUS_SUBORD_RTU_LINE_16_IS_INOPERABLE

RTUS_SUBORD_RTU_LINE_16_IS_OPERABLE

PROCONTROL 214 Status Codes

PCLP_STATION_SUSPENDED

PCLP_REPLY_TIMEOUT

PCLP_STOPPED

PCLP_UNEXPECTED_PR_COMMAND

PCLP_SIGNAL_QUEUE_EMPTY

PCLP_UNEXPECTED_PR_REPLY

PCLP_STATION_LINE_ERROR

PCLC_UNKNOWN_DESTINATION_STATION

PCLC_ATTRIBUTE_IS_WRITE_ONLY

PCLC_COMM_NOT_IMPLEMENTED

PCLC_INTERNET_COMM_NOT_IMPLEMENTED

PCLC_UNKNOWN_STA_ATTRIBUTE

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

3.3.14

ABB Automation

Status Codes

Technical Reference Manual

12824

12825

12826

12827

12828

12829

12830

12816

12817

12818

12819

12820

12821

12822

12823

12813

12814

12815

12831

PCLC_NOT_VALID_COMMAND

PCLC_ILLEGAL_COMMAND_CODE

PCLC_MESSAGE_CODING_ERROR

Result of an invalid transaction length.

PCLC_UNKNOWN_PCL_ATTRIBUTE

PCLC_UNKNOWN_DIAGNOSTIC_COUNTER

PCLC_SC_DATA_OVERFLOW

PCLC_INVALID_INDEX_RANGE

PCLC_INVALID_RT_ATTRIBUTE_VALUE

PCLC_ILLEGAL_LENGTH_FOR_GP

PCLC_ONLY_CHARACTER_TYPE_ALLOWED

PCLC_UNDEFINED_EV_CODE

PCLC_NO_MESSAGE_DATA

PCLC_ILLEGAL_LENGTH_FOR_ST

PCLC_ATTRIBUTE_IS_BROADCAST_ONLY

PCLC_ILLEGAL_BROADCAST_ATTRIBUTE

PCLC_INVALID_PCL_ADDRESS

PCLC_DEVICE_MUST_BE_ALLOCATED

PCLC_UNKNOWN_EVENT_TYPE

Result of an event type which has no handling routine.

PCLC_INTERNAL_BUFFER_FILLING_ERROR

Result of a buffer overflow in the protocol conversion.

SAT Device Status Codes

12851

12852

12853

12854

12855

12856

12857

12858

12859

12860

12861

12862

SATC_EVENT_QUEUE_EMPTY

SATC_EVENT_QUEUE_OVERFLOW

SATC_EVENT_QUEUE_CORRUPTED

SATP_STOPPED

SATC_UNKNOWN_ATTRIBUTE

SATC_INVALID_BCD_CODE

SATP_MESSAGE_TRANSLATION_ERROR

SATP_CHARACTER_FORMAT_ERROR

SATC_SCM_MESSAGE_FILLING_ERROR

SATC_EVENT_QUEUE_FULL

SATC_INVALID_EVENT_QUEUE_ADDRESS

SATC_NO_UNACCEPTED_EVENTS

MicroSCADA

3 Status Codes

81

MicroSCADA

3 Status Codes

3.3.15

3.3.16

82

Status Codes

Technical Reference Manual

12863

12864

12865

12866

12867

12868

12869

12870

12871

12872

12873

SATC_UNKNOWN_DIAGNOSTIC_COUNTER

SATC_INVALID_RT_ATTRIBUTE_VALUE

SATC_INVALID_REGISTER_ADDRESS

SATC_SC_DATA_OVERFLOW

SATC_INVALID_INDEX_RANGE

SATC_EMPTY_MESSAGE

SATC_INVALID_EVENT_CODE

SATC_THIS_EVENT_QUEUE_SLOT_IS_EMPTY

SATC_IV_NUM_OUT_OF_RANGE

SATC_EV_NUM_OUT_OF_RANGE

SATC_RV_NUM_OUT_OF_RANGE

BAG Device Status Codes

12950

12951

12952

12953

12954

12955

12956

12957

12958

12959

12960

12961

12901

12902

12903

12904

12905

12906

12907

12908

12909

12910

BAGP_STOPPED

BAGC_UNKNOWN_BAG_ATTRIBUTE

BAGP_REPLY_TIMEOUT

BAGP_STATION_LINE_ERROR

BAGP_STATION_SUSPENDED

BAGP_CANNOT_GET_POLL_MESSAGE

BAGP_CANNOT_GET_REPLY_BUFFER

BAGP_SYS_TIMEOUT

BAGC_ATTRIBUTE_IS_READ_ONLY

BAGC_ATTRIBUTE_IS_WRITE_ONLY

LCU Device Status Codes

LCUC_INVALID_ATTRIBUTE_VALUE

LCUC_INVALID_ATTRIBUTE_INDEX

LCUC_MEMORY_ALLOC_FAILED

LCUC_NO_DATA_AVAILABLE

LCUC_UNEXPECTED_VALUE_TYPE

LCUC_ILLEGAL_ANALOG_OUTPUT_ADDR

LCUC_ILLEGAL_DIGITAL_OUTPUT_ADDR

LCUC_ILLEGAL_OBJECT_TYPE

LCUC_DEVICE_MUST_BE_ALLOCATED

LCUC_REQ_D_DATA_AVAILABLE

LCUC_SC_DATA_OVERFLOW

LCUC_TOO_LONG_D_MES_RECEIVED

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

12987

12988

12989

12990

12991

12992

12994

12995

12996

12997

12998

12999

12970

12971

12972

12973

12974

12975

12976

12978

12962

12963

12964

12965

12966

12967

12968

12969

12979

12980

12981

12985

12986

LCUC_LCU_ADDRESS_NOT_CONFIGURED

LCUC_UNKNOWN_DIAGNOSTIC_COUNTER

LCUC_REQ_D_FAILED

LCUC_INVALID_INDEX_RANGE

LCUC_UNKNOWN_LCU_ATTRIBUTE

LCUC_SET_D_FAILED

LCUC_DO_DATABASE_NOT_VALID

LCUC_REQ_S_AFTER_SET_D_FAILED

LCUC_STS_AFTER_SET_D_AVAILABLE

LCUC_RTM_NO_DESTINATION_LINES_AVAILABLE

LCUC_UNEXPECTED_RESPONSE

LCUC_ATTRIBUTE_IS_READ_ONLY

LCUC_ILLEGAL_APPLICATION_FOR_OPERATION

LCUC_ATTRIBUTE_IS_WRITE_ONLY

LCUC_ILLEGAL_BROADCAST_ACTION

LCUC_RTM_MEMORY_ALLOC_FAILED

LCUC_INVALID_RTM_ATTR_ARRAY

LCUC_RTM_ALREADY_ACTIVE

LCUC_RTM_INVALID_LINE_NUMBER

LCUP_UNEXPECTED_DEV_REPLY_MSG_TYPE

LCUP_LOCAL_GI_RESET_FAILED

LCUP_TIMEOUT_WHILE_DOING_LOCAL_SET_GI

LCUP_LOCAL_SET_GI_FAILED

LCUP_DEVICE_SUSPENDED

LCUP_DEVICE_STOPPED

LCUP_DEVICE_STARTED

LCUP_OUT_OF_BUFFERS

LCUP_TIMEOUT_WHILE_WAITING_RESPONSE

LCUP_UNEXPECTED_BC_REPLY

LCUP_BROADCAST_FAILURE

LCUP_EXCEPTION_DETECTED

LCUP_LINE_ERROR_CAUSED_PA_READ_FAIL

LCUP_TIMEOUT_WHILE_DOING_PERIODIC_PA_READ

Timeout when a reply to PA poll is waited.

ABB Automation

83

MicroSCADA

3 Status Codes

3.3.17

3.3.18

3.3.19

84

Status Codes

Technical Reference Manual

1MRS751251-MEN

PAC Device Status Codes

13009

13010

13011

13012

13013

13014

13015

13016

13001

13002

13003

13004

13005

13006

13007

13008

13017

13018

13019

13020

13021

13022

13023

CCT Device Status Codes

PACP_ALLOCATION_FAILED

PACP_CANNOT_GET_MESSAGE

PACP_NO_PAC_REPLY

PACP_NOT_CORRECT_PAC_REPLY

PACP_TRANSITION_TO_SUSPENDED

PACP_TRANSITION_TO_STOPPED

PACP_IN_SUSPENDED_STATE

PACP_IN_STOPPED_STATE

PACC_UNKNOWN_PAC5_ATTRIBUTE

PACC_UNKNOWN_DIAGNOSTIC_COUNTER

PACC_SC_DATA_OVERFLOW

PACC_INVALID_INDEX_RANGE

PACC_INVALID_RT_ATTRIBUTE_VALUE

PACC_INVALID_ART_ATTRIBUTE_VALUE

PACC_INVALID_PD_ATTRIBUTE_VALUE

PACC_UNKNOWN_BASE_ADDRESS

PACC_LED_IMAGE_INDEX_OUT_OF_RANGE

PACC_INVALID_KEY_COUNT_ATTRIBUTE_VALUE

PACC_INVALID_LED_COUNT_ATTRIBUTE_VALUE

PACC_DIAGNOSTIC_COUNTER_OVERFLOW

PACC_PAC_MESSAGE_OVERFLOW

PACC_PAC_MESSAGE_READ_ERROR

PACC_INVALID_SCM_KEY_ADDRESS

Printer Status Codes

13101

13102

13103

PRIP_INVALID_PRINT_COMMAND_SOURCE

PRIC_MESSAGE_BUFFER_OVERFLOW

Contact an ABB representative.

PRIP_PRINTER_OFF_LINE

The printer is in off-line state (the printouts remain in the MicroSCADA printout queue). The reason may be, e.g.:

Paper is out.

The printer has been switched off manually.

ABB Automation

1MRS751251-MEN

3.3.20

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13104

13105

13106

13107

13108

13109

13110

13111

13112

13113

13115

13116

The printer is erronous.

NET sends a ssystem message (address = the MI attribute of the printer) when the printer is switched off-line (value = 13103) or on-line (value =

0).

PRIP_PRINTER_ON_LINE

PRIP_PRINTER_RESERVED_BY_OTHER_PROCESS

PRIC_UNKNOWN_PRINTER_ATTRIBUTE

PRIC_RELEASE_CMD_FROM_WRONG_PROCESS

PRIC_INVALID_COLOR_MESSAGE_FORMAT

The reason may be that printer has not been defined as a color printer in the basesystem.

PRIC_MESSAGE_FILLING_ERROR

PRIC_PRINTER_IN_USE

The attribute can not be changed while the printer is in use.

PRIC_INVALID_PT_ATTRIBUTE_VALUE

PRIC_INVALID_PE_ATTRIBUTE_VALUE

PRIP_NO_MORE_ITEMS_IN_BUFFER

PRIC_INVALID_INDEX_RANGE

PRIC_EMPTY_MESSAGE

The reason may be that printout format has not been defined or that there is no format picture.

13117

13118

13119

13120

13121

13122

13123

13124

13125

13126

PRIC_SC_DATA_OVERFLOW

PRIC_NO_MORE_LINE_PAIRS_IN_BUFFER

PRIP_NO_PRINTER_CONNECTION

PRIP_PRINTER_OFF_LINE_AND_NO_CONNECTION

PRIP_PRINTER_NOT_IN_USE

PRIC_INVALID_PIXEL_PATTERN

PRIC_MEMORY_ALLOCATION_FAILED

PRIP_PRINTER_STOPPED

PRIP_PRINTER_NOT_READY

PRIC_PRINTER_OFF_LINE_STATE_CANCELLED

SPA Device Status Codes

13201

13202

13203

13204

SPAC_SC_DATA_OVERFLOW

SPAC_TOO_LONG_REPLY_RECEIVED

SPAC_SPA_ADDRESS_NOT_CONFIGURED

SPAC_DEVICE_MUST_BE_ALLOCATED

85

MicroSCADA

3 Status Codes

86

Status Codes

Technical Reference Manual

1MRS751251-MEN

13234

13235

13251

13252

13253

13254

13255

13226

13227

13228

13229

13230

13231

13232

13233

13213

13214

13215

13216

13217

13218

13219

13220

13205

13206

13207

13208

13209

13210

13211

13212

13221

13222

13223

13224

13225

SPAC_UNKNOWN_DIAGNOSTIC_COUNTER

SPAC_INVALID_INDEX_RANGE

SPAC_INVALID_RT_ATTRIBUTE_VALUE

SPAC_UNKNOWN_SPA_ATTRIBUTE

SPAC_ILLEGAL_APPLICATION_FOR_OPERATION

SPAC_ATTRIBUTE_IS_WRITE_ONLY

SPAC_ILLEGAL_BROADCAST_ACTION

SPAC_UNEXPECTED_RESPONSE

SPAC_INVALID_ATTRIBUTE_VALUE

SPAC_CHAR_TYPE_EXPECTED

SPAC_INTERNAL_ERROR

SPAC_INVALID_POINT_DEFINITION

SPAC_DATABASE_UPDATE_COMPLETED

SPAC_TOO_MANY_ARGUMENTS

SPAC_ARGUMENT_EXPECTED

SPAC_UNABLE_TO_ALLOCATE_MEMORY

SPAC_POINT_DEFINITION_NOT_FOUND

SPAC_NO_ACKNOWLEDGE_RESPONSE

SPAC_UNEXPECTED_VALUE_TYPE

SPAC_ILLEGAL_OBJECT_TYPE

SPAC_ONLY_WRITE_IS_POSSIBLE

SPAC_NO_ACKNOWLEDGE_REPLY

SPAC_EVENT_DATA_DISCREPANCY_DETECTED

SPAC_NO_SM_REPLY_AVAILABLE

SPAC_OUT_OF_BUFFERS

SPAC_SM_ATTR_ACCESS_VIOLATION

SPAC_PARAMETER_TRANSFER_RESERVED

SPAC_PARAMETER_TRANSFER_RELEASE_DENIED

SPAC_POINT_ALREADY_EXISTS

SPAC_NV_INDEX_ALREADY_EXISTS

SPAC_NV_POLL_FAILED

SPAP_DEVICE_SUSPENDED

SPAP_DEVICE_STOPPED

SPAP_DEVICE_STARTED

SPAP_OUT_OF_BUFFERS

SPAP_TIMEOUT_WHILE_WAITING_RESPONSE

ABB Automation

1MRS751251-MEN

3.3.21

3.3.22

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13256

13257

13258

SPAP_UNEXPECTED_BC_REPLY

SPAP_BROADCAST_FAILURE

SPAP_DATABASE_UPDATE_COMPLETED

Bit Pad One (BPO) Device Status Codes

13272

13273

13274

13275

13276

13277

13278

13279

13280

13281

13282

13283

13302

13303

13304

13305

13306

BPOC_UNKNOWN_BIT_PAD_ONE_ATTRIBUTE

BPOC_UNKNOWN_MONITOR_NUMBER

BPOC_INVALID_MO_ATTRIBUTE_VALUE

BPOC_INVALID_INDEX_RANGE

BPOC_INVALID_BT_ATTRIBUTE_VALUE

REX Device Status Codes

13284

13285

13311

13312

13313

13314

REXP_DEVICE_STOPPED

REXP_DEVICE_STARTED

REXP_DEVICE_HALTED

REXP_OUT_OF_BUFFERS

REXP_TIMEOUT_WHILE_WAITING_RESPONSE

REXP_DEVICE_CONNECTING

REXP_DISCONN_IND_RECEIVED

REXP_CONN_CON_RECEIVED

REXP_EVENT_SESSION_REJECTED

REXP_EVENT_SESSION_SETUP_TIMEOUT

REXP_RUNNING_MODE_OPERATION_CONFLICT

REXP_DEVICE_WAITING_GO_COMMANDS

When session setup command has been successfully executed, the REX device in PC-NET sends this status code to indicate that it is ready to receive the General Object Handling Commands (REX GO attribute) from the MicroSCADA application.

REXP_SETUP_SESSION_REJECTED

If the device sends a negative response to the General Object Handling command, the SCIL command will get this status.

REXP_SETUP_SESSION_TIMEOUT

If the device sends a negative response to the General Object Handling command, the SCIL command will get this status.

REXC_SC_DATA_OVERFLOW

REXC_LON_ADDRESS_NOT_CONFIGURED

REXC_DEVICE_MUST_BE_ALLOCATED

REXC_UNKNOWN_DIAGNOSTIC_COUNTER

87

MicroSCADA

3 Status Codes

88

Status Codes

Technical Reference Manual

1MRS751251-MEN

13323

13324

13325

13326

13327

13328

13329

13330

13315

13316

13317

13318

13319

13320

13321

13322

13331

13332

13333

13334

13335

13336

13337

13338

13339

13340

13341

13342

13345

13346

13347

13348

REXC_INVALID_INDEX_RANGE

REXC_ILLEGAL_APPLICATION_FOR_OPERATION

REXC_ATTRIBUTE_IS_WRITE_ONLY

REXC_INVALID_ATTRIBUTE_VALUE

REXC_CHAR_TYPE_EXPECTED

REXC_INTERNAL_ERROR

REXC_INVALID_POINT_DEFINITION

REXC_TOO_MANY_ARGUMENTS

REXC_ARGUMENT_EXPECTED

REXC_UNABLE_TO_ALLOCATE_MEMORY

REXC_POINT_DEFINITION_NOT_FOUND

REXC_NO_ACKNOWLEDGE_RESPONSE

REXC_UNEXPECTED_VALUE_TYPE

REXC_ILLEGAL_OBJECT_TYPE

REXC_ONLY_WRITE_IS_POSSIBLE

REXC_NO_ACKNOWLEDGE_REPLY

REXC_NO_SM_REPLY_AVAILABLE

REXC_OUT_OF_BUFFERS

REXC_SM_ATTR_ACCESS_VIOLATION

REXC_PARAMETER_TRANSFER_RESERVED

REXC_PARAMETER_TRANSFER_RELEASE_DENIED

REXC_ILLEGAL_BROADCAST_ACTION

REXC_ILLEGAL_IEC_EVENT_RECEIVED

REXC_GI_ACTIVATION_CONF_RECEIVED

REXC_GI_TERMINATION_RECEIVED

REXC_UNABLE_TO_CONVERT_FROM_SC_COMMAND

REXC_INVALID_RT_ATTRIBUTE_VALUE

REXC_UNKNOWN_LON_ATTRIBUTE

REXC_FT_CHECKSUM_ERROR

Checksum error in download or upload procedure

REXC_FT_DEVICE_MEMORY_ERROR

Unsuccesful memory allocation in device

REXC_FT_COMMUNICATION_SERVICE_ERROR

REXC_FT_FILE_OR_DIR_ID_ERROR

File or directory with given ID does not exist

ABB Automation

1MRS751251-MEN

3.3.23

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13409

13421

13422

13423

13424

13425

13426

13427

13401

13402

13403

13404

13405

13406

13407

13408

13428

13429

13430

13431

13432

13433

13434

13435

13436

13437

13349 REXC_FT_DEVICE_UNABLE_TO_PERFORM_COMMAND

The requested file from device could not uploaded or deleted. Negative response from device.

13350

13351

13352

13353

13354

13371

REXC_FT_COMMUNICATION_TIMEOUT

REXC_FT_SIMULTANEOUS_SERVICE_NOT_ALLOWED

REXC_FT_CANCELLED_BY_DEVICE

REXC_FT_DIRECTORY_ENTRY_CREATED_BY_DEVICE

REXC_FT_FILE_OR_DIRECTORY_DOES_NOT_EXIST

REXP_DEVICE_SUSPENDED

LMK Device Status Codes

LMKP_DEVICE_SUSPENDED

LMKP_DEVICE_STARTED

LMKP_DEVICE_STOPPED

LMKP_DEVICE_ALREADY_STARTED

LMKP_DEVICE_ALREADY_STOPPED

LMKP_OUT_OF_MESSAGE_BUFFERS

LMKP_TIMEOUT_WHILE_WAITING_COMPLETION

LMKP_TIMEOUT_WHILE_WAITING_REPLY

LMKP_NV_POLL_FAILED

LMKC_ATTRIBUTE_IS_WRITE_ONLY

LMKC_ILLEGAL_APPLICATION_FOR_OPERATION

LMKC_ONLY_WRITE_IS_POSSIBLE

LMKC_NO_POINT_FOR_THIS_SYS_INDEX_FOUND

LMKC_POINT_NOT_AN_OUTPUT

LMKC_DATA_OUT_OF_RANGE_FOR_OUTPUT_TYPE

LMKC_WRONG_DATA_TYPE_FOR_OUTPUT_TYPE

LMKC_UNKNOWN_LMK_ATTRIBUTE

LMKC_INTERNAL_ERROR

LMKC_SC_DATA_OVERFLOW

LMKC_NO_LM_REPLY_AVAILABLE

LMKC_INVALID_RT_ATTRIBUTE_VALUE

LMKC_ARGUMENT_EXPECTED

LMKC_INVALID_INDEX_RANGE

LMKC_INVALID_ATTRIBUTE_VALUE

LMKC_PARAMETER_TRANSFER_RESERVED

LMKC_PARAMETER_TRANSFER_RELEASE_DENIED

89

MicroSCADA

3 Status Codes

3.3.24

90

Status Codes

Technical Reference Manual

13467

13468

13469

13470

13471

13472

13473

13474

13475

13476

13477

13459

13460

13461

13462

13463

13464

13465

13466

13450

13451

13453

13454

13455

13456

13457

13458

13438

13439

13440

13441

13442

13443

13444

LMKC_UNKNOWN_DIAGNOSTIC_COUNTER

LMKC_DEVICE_MUST_BE_ALLOCATED

LMKC_UNABLE_TO_ALLOCATE_MEMORY

LMKC_TOO_MANY_ARGUMENTS

LMKC_POINT_ALREADY_EXISTS

LMKC_NV_INDEX_ALREADY_EXISTS

LMKC_POINT_DEFINITION_NOT_FOUND

RP570 Slave Status Codes

SPIC_INVALID_INDEX_RANGE

SPIC_ILLEGAL_ATTRIBUTE_VALUE

SPIC_UNKNOWN_DIAGNOSTIC_COUNTER

SPIC_SC_DATA_OVERFLOW

SPIC_UNKNOWN_SPI_ATTRIBUTE

SPIC_TEV_BUFFER_OVERFLOW

SPIC_UNKNOWN_FNC_RECEIVED

SPIC_INVALID_FNC_RECEIVED

SPIC_FCOM_COLDSTART_RECEIVED

SPIC_UNKNOWN_FCOM_RECEIVED

SPIC_ILLEGAL_FCOM_RECEIVED

SPIC_CBXC_RECEIVED

SPIC_IHC_RECEIVED

SPIC_IHC_FAILED

SPIC_EXC_FAILED

SPIC_ERMI_BUFFER_OVERFLOW

SPIC_PREV_PC_VALUE_NOT_YET_REPORTED

SPIC_PULSECOUNTER_IS_BLOCKED

SPIC_ARGUMENT_EXPECTED

SPIC_TOO_MANY_ARGUMENTS

SPIC_NOT_ACTIVE_OR_NO_FTAB_LOADED

SPIC_FCOM_ACTIVATE_RECEIVED

SPIC_FCOM_DEACTIVATE_RECEIVED

SPIC_UNKNOWN_FTAB_RECEIVED

SPIC_INVALID_FTAB

SPIC_FTAB_NOT_IMPLEMENTED

SPIC_POINT_NOT_INITIALIZED_WHILE_DI_0

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

3.3.25

3.3.26

3.3.27

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13486

13487

13488

13490

13491

13492

13493

13494

13495

13478

13479

13480

13481

13482

13483

13484

13485

Monitor Status Codes

SPIC_ERMX_NOT_RECORDED

SPIC_INVALID_FUNCTION_CODE

SPIP_CBXC_RECEIVED

SPIP_IHC_RECEIVED

SPIP_EXC_FAILED

SPIP_ILLEGAL_FNC_RECEIVED

SPIP_COMMUNICATION_WITH_CS_LOST

SPIP_COMMUNICATION_WITH_CS_ESTABLISHED

SPIP_UNIMPLEMENTED_FNC_RECEIVED

SPIP_UNABLE_TO_ALLOCATE_MEMORY

SPIP_COMMANDS_BLOCKED_FROM_MASTER

SPIC_NOT_IN_EXCLUSIVE_COMMAND_MODE

SPIC_INVALID_TEV_NUMBER

SPIC_TDR_QUEUE_FULL

SPIC_EXCLUSIVE_COMMAND_TIMEOUT

SPIC_INVALID_TDR_LENGTH

SPIC_INVALID_TSTA_ID

13501

13502

13503

13504

MONC_INVALID_MONITOR_ADDRESS

MONC_MONITOR_IN_USE

MONC_UNKNOWN_MONITOR_ATTRIBUTE

MONC_INVALID_INDEX_RANGE

ADE Device Status Codes

13551

13552

13553

ADEC_INVALID_INDEX_RANGE

ADEC_SC_DATA_OVERFLOW

ADEC_UNKNOWN_ADEMCO_ATTRIBUTE

PCO Device Status Codes

13601

13602

13603

13604

13605

13606

13621

PCOP_DEVICE_STARTED

PCOP_TIMEOUT_WHILE_WAITING_RESPONSE

PCOP_DEVICE_SUSPENDED

PCOP_DEVICE_RESPONDING_AGAIN

PCOP_DEVICE_RESTARTED_QUEUE_EMPTY

PCOP_DEVICE_STOPPED

PCOC_INVALID_INDEX_RANGE

91

MicroSCADA

3 Status Codes

3.3.28

92

Status Codes

Technical Reference Manual

13659

13660

13661

13662

13663

13664

13665

13666

13651

13652

13653

13654

13655

13656

13657

13658

13667

13668

13669

13630

13631

13632

13633

13634

13635

13636

13622

13623

13624

13625

13626

13627

13628

13629

PCOC_SC_DATA_OVERFLOW

PCOC_UNKNOWN_RCOM_ATTRIBUTE

PCOC_INVALID_ATTRIBUTE_VALUE

PCOC_PLC_PROGRAM_NOT_RESPONDING

PCOC_ILLEGAL_APPLICATION_FOR_OPERATION

PCOC_ATTRIBUTE_IS_WRITE_ONLY

PCOC_FCOM_NUMBER_NOT_USED

PCOC_INVALID_FCOM_NUMBER

PCOC_UNEXPECTED_RESPONSE

PCOC_SYSTEM_MESSAGE_RECEIVED

PCOC_INVALID_RT_ATTRIBUTE_VALUE

PCOC_RCOM_UNIT_NOT_NORMALIZED

PCOC_NOT_VALID_FOR_BROADCAST

PCOC_OUT_OF_BUFFERS

PCOC_SUBSTATION_PLC_STOPPED

WESC Device Status Codes

WESC_TT_QUEUE_EMPTY

WESC_TT_QUEUE_OVERFLOW

WESC_TT_QUEUE_CORRUPTED

WESP_STOPPED

WESC_UNKNOWN_ATTRIBUTE

WESC_INVALID_CRC_CODE

WESP_MESSAGE_TRANSLATION_ERROR

WESP_CHARACTER_FORMAT_ERROR

WESC_SCM_MESSAGE_FILLING_ERROR

WESC_EVENT_QUEUE_FULL

WESC_INVALID_EVENT_QUEUE_ADDRESS

WESC_NO_UNACCEPTED_EVENTS

WESC_UNKNOWN_DIAGNOSTIC_COUNTER

WESC_INVALID_RT_ATTRIBUTE_VALUE

WESC_INVALID_REGISTER_ADDRESS

WESC_SC_DATA_OVERFLOW

WESC_INVALID_INDEX_RANGE

WESC_EMPTY_MESSAGE

WESC_INVALID_EVENT_CODE

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

3.3.29

3.3.30

3.3.31

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13670

13671

13672

13673

13674

13675

13676

13677

13678

13679

WESC_THIS_EVENT_QUEUE_SLOT_IS_EMPTY

WESC_ID_NUM_OUT_OF_RANGE

WESC_AV_NUM_OUT_OF_RANGE

WESC_TT_NUM_OUT_OF_RANGE

WESC_TT_QUEUE_FULL

WESC_NOT_IMPLEMENTED

WESC_INVALID_FT_VECTOR_LENGTH

WESC_INVALID_CATEGORY_NUMBER

WESC_INVALID_GROUP_NUMBER

WESC_INVALID_BINARY_VALUE

Errors in ACP/MDLC Gateway (Motorola)

ATR Device Status Codes

13800

13801

13802

13803

13804

13805

13806

13807

13808

13751

13752

13753

13754

13755

13756

13757

13758

13759

13760

13761

13762

ATRP_SESSION_BEGIN

ATRP_NOT_ALLOWED_WHILE_COMMUNICATING

ATRP_SESSION_END

ATRP_SESSION_ABORTED

ATRP_SESSION_STOPPED

ATRC_UNKNOWN_ATTRIBUTE

ATRC_SESSION_FIFO_FULL

ATRC_TOO_LONG_MESSAGE

ATRC_STATION_NOT_IN_USE

ATRC_LINE_NOT_IN_USE

ATRC_ILLEGAL_ATTRIBUTE_VALUE

ATRC_LINE_RESERVED

PLC Device Status Codes

PLCP_IN_INITIALIZE_DB_STATE

PLCP_DEVICE_SUSPENDED

PLCP_STOPPED

PLCP_STARTTED

PLCC_MESSAGE_FILLING_ERROR

PLCC_INVALID_OBJECT_TYPE

PLCC_INVALID_ADDRESS

PLCC_INVALID_DATA

PLCC_INVALID_OBJECT_INDEX

93

MicroSCADA

3 Status Codes

3.3.32

Status Codes

Technical Reference Manual

1MRS751251-MEN

13817

13818

13819

13820

13821

13822

13823

13824

13825

13826

13827

13828

13829

13830

13831

13809

13810

13811

13812

13813

13814

13815

13816

IEC Device Status Codes

PLCC_NOT_IMPLENTED_FUNCTION

PLCC_NOT_EXPECTED_FUNCTION_CODE_FROM_PLC

PLCC_ILLEGAL_PLC_FUNCTION

PLCC_ILLEGAL_PLC_DATA_ADDRESS

PLCC_ILLEGAL_PLC_DATA_VALUE

PLCC_SLAVE_DEVICE_FAILURE

PLCC_ACKNOWLEDGE

PLCC_SLAVE_DEVICE_BUSY

PLCC_NEGATIVE_ACKNOWLEDGE

PLCC_MEMORY_PARITY_ERROR

PLCC_UNKNOWN_DIAGNOSTIC_COUNTER

PLCC_INVALID_TOPIC_NUMBER

PLCC_INVALID_OBJECT_ADDRESS

PLCC_INVALID_OBJECT_FORMAT

PLCC_SC_DATA_OVERFLOW

PLCC_INVALID_INDEX_RANGE

PLCC_UNKNOWN_ATTRIBUTE

PLCC_LOCAL_RESPONSE

PLCP_TIMEOUT_WHILE_WAITING_RESPONSE

PLCP_EVENT_BUFFER_OK

PLCP_EVENT_BUFFER_OVERFLOW

PLCP_EVENT_BUFFER_ERROR

PLCC_UNKNOWN_FUNCTION

13851

13852

13853

13854

ICCC_INVALID_ATTRIBUTE_VALUE

The value set to an attribute of a IEC station is incorrect, e.g. one of the elements of the vector written to the SD attribute is out of range.

ICCC_INVALID_INDEX_RANGE

The index range used when accessing an attribute of an IEC station is incorrect.

ICCC_INVALID_ATTRIBUTE

The STA object attribute used is not valid for IEC 60870-5-101 slave protocol.

ICCC_ASDU_TABLE_NOT_CREATED

Internal software error.

94

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13855

13856

13857

13858

13859

13860

13861

13862

13863

13864

13865

13866

13867

13868

13869

ICCC_UNKNOWN_ASDU_NAME

The name of the ASDU written to the SD or EV attribute is not supported.

ICCC_ASDU_QUEUE_FULL

No more events can be written to one of the queues by using the SD or

EV attribute since the queue is full.

ICCC_MESSAGE_BUFFER_FULL

Internal software error. The value of ML attribute may be too small.

ICCC_MESSAGE_FILLING_ERROR

Internal software error. The value of ML attribute may be too small.

ICCC_UNKNOWN_ASDU

The number of the ASDU written to the SD or EV attribute is not supported.

ICCC_NO_ACTIVE_COMMAND

There is not a preceding command with the address given when confirming a command using the CF attribute. Either the address is incorrect or the command has not been received.

ICCC_INVALID_QUEUE_NUMBER

The index of the SD or EV attribute is incorrect.

ICCC_SC_DATA_OVERFLOW

Internal software error.

ICCC_DEVICE_SUSPENDED

The IEC station is in suspended state. The reason for this could be that the link is not properly established (e.g. incorrect cable wiring) or the master station does not respond.

ICCC_MESSAGE_SENDING_ERROR

Internal software error. This may be a result of problem in wiring or hardware.

ICCC_REMOTE_DEVICE_REPLIES_WITH_NACK

The master did not accept the message but responded with negative acknowledgement instead. Not used in unbalanced mode.

ICCC_LINK_NOT_READY

A message is sent to a line with a non-established communication.

ICCC_CONFIRMATION_OF_CMD_IS_NOT_READY

ICCC_OUT_OF_BUFFERS

Internal software error. Operation could not be completed since the buffer pool has ran out of buffers

ICCC_DONT_REPLY

Internal software error.

95

MicroSCADA

3 Status Codes

3.3.33

96

Status Codes

Technical Reference Manual

1MRS751251-MEN

13870

13871

13872

13873

13874

13875

13876

13877

13878

13879

13880

13881

ICCC_CONFIRMATION_TIMEOUT

An activation confirmation to a command was not received from the IEC slave in the time defined by the RT attribute.

ICCC_NEGATIVE_CONFIRMATION

The activation confirmation received from the IEC slave was negative, i.e. the command failed.

ICCC_DEVICE_STOPPED

The station has been set out of use using the IU attribute.

ICCC_NO_ADDRESS_IN_ACP

Internal software error.

ICCC_UNEXPECTED_OV_VALUE

ICCC_UNEXPECTED_TYPE_IN_ACP

Internal software error.

ICCC_UNSUPPORTED_COMMAND_TYPE

The value of the TY attribute written to an output process object is not a type id of a supported ASDU.

ICCC_OV_VALUE_NOT_FOUND

OV attribute is missing from the list written to an output process object.

ICCC_OG_VALUE_NOT_FOUND

ICCC_QL_VALUE_NOT_FOUND

QL attribute is missing from the list written to an output process object.

ICCC_TY_VALUE_NOT_FOUND

TY attribute is missing from the list written to an output process object.

ICCC_DEVICE_STARTED

The station has been set out of use using the IU attribute.

Status codes for DNP devices

13901

13902

13903

13904

DNPC_INVALID_ATTRIBUTE_VALUE

The value set to an attribute of a DNP station is out of range.

DNPC_INVALID_INDEX_RANGE

The index range used when accessing an attribute of a DNP station is incorrect.

DNPC_INVALID_ATTRIBUTE

The STA object attribute used is not valid for DNP V3.00 slave protocol.

DNPC_EVENT_QUEUE_FULL

No more events can be written to one of the unsolicited message queues using the EV attribute since the queue is full.

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13905

13906

13907

13909

13910

13912

13913

13914

13915

13918

13919

13920

13921

13911

13916

DNPC_MESSAGE_BUFFER_FULL

Internal software error.

DNPC_MESSAGE_FILLING_ERROR

Internal software error.

DNPC_UNKNOWN_OBJECT_TYPE

The data object type used with the SD or EV attributes is not supported.

DNPC_SC_DATA_OVERFLOW

Internal software error.

DNPC_DEVICE_SUSPENDED

The DNP station is in suspended state. The reason for this could be that the link is not properly established (e.g. incorrect cable wiring) or the master station does not respond.

DNPC_MESSAGE_SENDING_ERROR

Internal software error. Device status is set to this value if the message handling has failed. The sending may fail due to e.g. an error in the physical communication link.

DNPC_REMOTE_DEVICE_REPLIES_WITH_NACK

The DNP slave station responses with a negative acknowledgement.

DNPC_LINE_NOT_READY

A command is sent to a line with a non-established communication.

DNPC_OUT_OF_BUFFERS

Internal software error.

DNPC_RESPONSE_TIMEOUT

The time determined by the RT attribute (first APDU) or RT+AT attributes (last APDU) has expired while waiting for a response from the slave.

DNPC_CONFIRMATION_TIMEOUT

The time determined by the CT attribute has expired while waiting for a confirmation from the slave.

DNPC_DEVICE_STOPPED

The station has been set out of use using the IU attribute.

DNPC_DEVICE_STARTED

The station has been set to use using the IU attribute.

DNPC_UNEXPECTED_OV_VALUE

The value set to the OV attribute of an output process object is not valid.

DNPC_ERROR_IN_ACP

Internal software error.

97

MicroSCADA

3 Status Codes

98

Status Codes

Technical Reference Manual

1MRS751251-MEN

13931

13934

13936

13937

13938

13939

13940

13941

13924

13925

13926

13927

13928

13929

13930

13942

DNPC-NET_BUFFER_ERROR

Internal software error.

DNPC_NO_ACTIVE_COMMAND

There is not a preceding command with the address given when confirming a command using the CF attribute. Either the address is incorrect or the command has not been received.

DNPC_INTERNAL_ERROR

Internal software error.

DNPC_LINK_LINE_DOES_NOT_EXIST

The line to which the DNP station is created is incorrect (not a DNP line).

DNPC_NOT_ENOUGH_ITEMS

The vector, that is written to SD or EV attribute does not have correct number of elements.

DNPC_INVALID_EVENT_CLASS

The index of the SD or EV attribute is incorrect.

DNPC_POINT_NOT_INITIALIZED_WHILE_DI_0

Data is written to a data point which has not been initialised using the SD attribute while the DI attribute is set to 0.

DNPC_UNKNOWN_CONTROL_BLOCK

The CODE item of a received control block message is unknown.

DNPC_UNEXPECTED_TYPE_IN_SUBITEM

Internal software error.

DNPC_APDU_SCAN_ERROR

Internal software error.

DNPC_UNKNOWN_VARIATION

The variation received from the slave is not supported.

DNPC_ACP_MESSAGE_FULL

Internal use only.

DNPC_UNKNOWN_QUALIFIER

Internal use only.

DNPC_ALLOCATION_FAILED

Internal software error.

DNPC_BACKGROUND_POLL_ACTIVE

A command was issued while the DNP master station was waiting for a response to a data poll request.

DNPC_PREVIOUS_CMD_STILL_ACTIVE

A command was issued while the DNP master station was waiting for a response to the previous command.

ABB Automation

1MRS751251-MEN

3.3.34

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

13943

13944

DNPC_POLL_NOT_DEFINED

A poll has not been defined for the index used when reading the SD attribute.

DNPC_ANOTHER_COMMAND_ALREADY_PENDING

This status is returned when one command from SCIL is already waiting to be sent (MT-timer is on) and user issues a new command from SCIL.

This situation is possible only when parallel execution of SCIL procedures is possible.

14016

14017

14018

14019

14020

14024

14025

14026

14029

14030

14006

14007

14009

14010

14012

14013

14014

14015

NET Network Layer Status Codes

14001

14002

14003

14004

14005

NETW_APPLICATION_PROCESS_DOES_NOT_EXIST

NETW_ATTRIBUTE_ACCESS_RIGHT_VIOLATION

You have tried to set an attribute that can be read only, or read an attribute that can be set only.

NETW_ATTRIBUTE_INDEX_RANGE_ERROR

NETW_DESTINATION_DEVICE_IN_USE

While a device is in use (IU = 1) it cannot be deleted on-line.

NETW_DESTINATION_DEVICE_NOT_IN_USE

While the device is out of use, it is not possible to communicate with it.

NETW_DESTINATION_LINE_NOT_IN_USE

NETW_INVALID_AB_MESSAGE_LENGTH

NETW_INVALID_SC_FUNCTION_VALUE

NETW_INVALID_SC_FUNCTION_VALUE_FOR_REPLY

NETW_LINK_PROCESS_DOES_NOT_EXIST

NETW_LOGICAL_NAME_TRANSLATION_ERROR

NETW_LOGICAL_NAME_WITHOUT_TRANSLATION

NETW_NET_PROCESS_DOES_NOT_EXIST

NETW_UNKNOWN_DESTINATION_DEVICE

NETW_UNKNOWN_DESTINATION_LINE

NETW_UNKNOWN_DEVICE_ATTRIBUTE

NETW_UNKNOWN_LOGICAL_NAME

NETW_UNKNOWN_PHYSICAL_NAME

NETW_DEVICE_DOES_NOT_EXIST

NETW_DEVICE_IN_USE_CANT_BE_DELETED

NETW_ERROR_IN_MESSAGE_DATA_STRUCTURE

NETW_INDEX_RANGE_NOT_ALLOWED

NETW_LINE_MUST_BE_STOPPED_FIRST

The operation demands that the line is taken out of use first (IU=0).

99

MicroSCADA

3 Status Codes

100

Status Codes

Technical Reference Manual

1MRS751251-MEN

14056

14057

14058

14059

14060

14061

14062

14063

14064

14065

14042

14043

14044

14045

14046

14047

14048

14049

14050

14051

14052

14053

14054

14055

14031

14032

14033

14034

14037

14038

14040

14041

NETW_MAX_PHYSICAL_BPO_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_SID_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_PAC_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_SAT_NUMBER_EXCEEDED

NETW_UNACCEPTABLE_CHARACTER_ITEM

NETW_UNACCEPTABLE_LOGICAL_NAME_FORMAT

NETW_MAX_PHYSICAL_MON_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_SYS_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_STA_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_PRI_NUMBER_EXCEEDED

NETW_INVALID_STATION_ADDRESS

NETW_MESSAGE_BUFFER_OVERFLOW

NETW_LINE_NUMBER_OUT_OF_RANGE

NETW_LINE_DOES_NOT_EXIST

NETW_DEVICE_TYPES_CANT_BE_MIXED

NETW_ROUTING_INFO_MISSING

NETW_UNKNOWN_SOURCE_DEVICE

NETW_SOURCE_DEVICE_NOT_IN_USE

NETW_WRONG_DESTINATION_TYPE

NETW_UNWAITED_REPLY

NETW_INVALID_DEVICE_TYPE

NETW_OUT_OF_MEMORY

The free memory in NET is not enough for the execution of the desired operation.

NETW_FUNCTION_NOT_IMPLEMENTED

NETW_INVALID_LOGICAL_NAME_TRANSLATION

NETW_UNKNOWN_LOGICAL_NAME_TRANSLATION

NETW_INVALID_LOGICAL_NAME

NETW_INVALID_LOGICAL_NAME_RANGE

NETW_NAME_IS_PHYSICAL

NETW_LOGICAL_NAME_ALREADY_RESERVED

NETW_UNKNOWN_DEVICE_TYPE

NETW_DEVICE_ALREADY_EXISTS

NETW_LDS_TRANSLATION_LIMIT_EXCEEDED

The message has been routed forwards in the NET network as many times as defined for maximum by the TL attribute. The message is no

ABB Automation

1MRS751251-MEN

3.3.35

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

14066

14067 more sent to the object device. An answer message with this error code is sent to the message sender.

NETW_LINK_ACE_PROCESS_DOES_NOT_EXIST

The line has not an autocaller process.

NETW_DESTINATION_LINE_IN_USE

The destination line is in use and therefore its attributes may not be updated.

14076

14077

14078

14079

14080

14081

14082

14083

14068

14069

14070

14071

14072

14073

14074

14075

14084

14085

14086

14087

14088

NETW_LINE_IS_NOT_AN_ACE_LINE

NETW_NO_CONNECTION_ON_ACE_LINE

NETW_MAX_PHYSICAL_NET_NUMBER_EXCEEDED

NETW_INVALID_PHYSICAL_DEVICE_NUMBER

NETW_MAX_PHYSICAL_RTU_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_PCL_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_SIN_NUMBER_EXCEEDED

NETW_TC_TELEGRAM_TYPE_UNDEFINED

NETW_TRANSLATION_LOOP_NOT_ALLOWED

NETW_PROCESS_TABLE_FULL

NETW_MAX_PHYSICAL_LCU_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_ADE_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_SPA_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_EDEV_NUMBER_EXCEEDED

NETW_INVALID_DV_ATTRIBUTE_INDEX

NETW_MAX_PHYSICAL_SPI_NUMBER_EXCEEDED

NETW_NODE_REFERENCED_CANT_BE_DELETED

NETW_LINE_IS_FULL

NETW_INVALID_DEVICE_TYPE_FOR_THIS_LINE

NETW_MAX_PHYSICAL_REX_NUMBER_EXCEEDED

NETW_MAX_PHYSICAL_LMK_NUMBER_EXCEEDED

Common NET Link Layer Status Codes

16001

16002

16003

LINK_CTS_LINE_IS_INACTIVE

NET does not get Clear To Send signal.

LINK_CTS_LINE_REMAINS_INACTIVE

NET does not get Clear To Send signal.

LINK_DCD_LINE_IS_INACTIVE

NET does not get Data Carrier Detect.

101

MicroSCADA

3 Status Codes

102

Status Codes

Technical Reference Manual

1MRS751251-MEN

16013

16014

16015

16016

16018

16019

16004

16005

16006

16007

16008

16009

16011

16012

16020

16021

16022

16023

16024

16025

16026

16027

16028

16029

16030

16031

16032

16033

16034

16035

LINK_DCD_LINE_REMAINS_INACTIVE

LINK_ATTRIBUTE_NOT_YET_IMPLEMENTED

LINK_CN_ATTRIBUTE_NOT_YET_IMPLEMENTED

LINK_CREATION_OF_LINK_PROCESSES_FAILED

LINK_DEVICES_MUST_BE_DELETED_FIRST

LINK_IS_ATTRIBUTE_NOT_YET_IMPLEMENTED

LINK_LINE_ATTRIBUTE_VALUE_OUT_OF_RANGE

LINK_MEMORY_EXCEEDED_FOR_PRIORITY_POOL

LINK_NOT_ENOUGH_MEMORY_FOR_LINE_BUFFERS

LINK_ONLY_RAM_PROTOCOL_ALLOWED_ON_LIN_13

LINK_RAM_PROTOCOL_ALLOWED_ONLY_ON_LIN_13

LINK_REDUNDANCY_REQUIRED_FOR_ANSI_X3

LINK_MEMORY_EXCEEDED_FOR_NORMAL_POOL

LINK_LINE_MUST_FIRST_BE_STOPPED

The operation demands that the line is taken out of use (IU = 0).

LINK_ONLY_8_DATA_BITS_ALLOWED

LINK_OPERATION_NOT_ALLOWED_ON_LINE_13

LINK_NOT_ENOUGH_MEMORY

There is not enough free memory for this operation.

LINK_LINE_NOT_CREATED

LINK_INVALID_LINE_NUMBER

LINK_STATION_ADDRESS_ALREADY_IN_USE

LINK_INVALID_DEV_SA_ATTRIBUTE_VALUE

Allowed values for the ANSI station address:

In decimal form: 8..63, 72..254 (255 = Broadcast)

In octal form: 10..77, 110..376 (377 = Broadcast

LINK_INDEX_RANGE_ERROR

LINK_NONACCEPTABLE_PHONE_NUMBER

LINK_NO_CONNECTION_OPEN

LINK_CONNECTED_ACE_LINE_CANT_BE_STOPPED

A connection is open on the line, and therefore it cannot be stopped.

LINK_DIAL_FAILS_BECAUSE_LINE_NOT_IDLE

LINK_NO_ACE_ON_THIS_LINE

LINK_INVALID_DEV_PA_ATTRIBUTE_VALUE

LINK_LINE_NUMBER_OUT_OF_RANGE

LINK_LINE_DOES_NOT_EXIST

ABB Automation

1MRS751251-MEN

3.3.36

3.3.37

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

16036

16037

16038

16039

16040

16041

16042

16043

16044

16045

16046

LINK_DEVICE_TYPE_NOT_ALLOWED_ON_LINE

LINK_ONLY_RAM_OR_COM1_PROTOCOL_ON_LIN_13

LINK_RAM_OR_COM1_PROTOCOL_ONLY_ON_LIN_13

LINK_REDUNDANCY_NOT_CONFIGURABLE

LINK_SA_USED_ON_ANOTHER_LINE

LINK_CTS_FAILURE

LINK_ONLY_RM_OR_IL_ALLOWED_ON_LIN_13

LINK_IL_PROTOCOL_ALLOWED_ONLY_ON_LIN_13

LINK_LINE_OPEN_FAIL

LINK_LINE_CLOSE_ABNORMAL

LINK_LINE_ALREADY_RUNNING

Full Duplex Protocol Status Codes

16101

16102

16103

16104

16105

16106

16107

XFTP_ENQ_LIMIT_EXCEEDED

The device did not answer until the ENQ limit was reached. The reason may be e.g. that the transmission speed has been incorrectly defined

(differently in NET and the RTU).

XFTP_LINE_STUCKED

Clear To Send and Data Carrier Detect are OK, but the messages are not transmitted on the line. The reason may be e.g. that Transmit Data and

Receive Data are connected incorrectly.

XFTP_MODEM_LINE_ERROR_DURING_TRANSMISSION

XFTP_MODEM_LINE_ERROR_IN_RESPONSE_WAIT

XFTP_NAK_LIMIT_EXCEEDED

XFTP_LINE_PASSIVATED

The connection has been broken.

XFTP_LINE_ACTIVATED_BY_LOCAL

The dialling is successful and connection is arising (full duplex).

16108 XFTP_LINE_ACTIVATED_BY_REMOTE

NET is answering to the call and connection is arising.

16109 XFTP_LINE_IS_PASSIVE

Half Duplex Protocol Status Codes

16201

16202

16204

XHCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

The Clear To Send signal changed to inactive during the transmission (on

ANSI X3.28/AB Half Duplex protocol).

XHCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

XHCP_DST_STATION_IS_NOT_ON_THIS_LINE

103

MicroSCADA

3 Status Codes

3.3.38

3.3.39

3.3.40

3.3.41

Status Codes

Technical Reference Manual

1MRS751251-MEN

16205

16206

16207

16208

XHCP_TIMEOUT_WHILE_WAITING_ACK

The RTU did not answer with ACK until the waiting time (the TI attribute) was up, although the message has been sent again. The reason may be, e.g. that NET does not get Data Carrier Detect signal or that the transmission speed has been defined diff

XHCP_TIMEOUT_WHILE_WAITING_CTS

XHCP_LINE_PASSIVATED

The connection has been broken.

XHCP_LINE_ACTIVATED_BY_LOCAL

The dialling is successful and connection is arising (half duplex).

16209 XHCP_LINE_ACTIVATED_BY_REMOTE

NET is answering to the call and connection is arising.

16210

16211

16212

16213

XHCP_LINE_IS_PASSIVE

XHCP_TIMEOUT_WHILE_WAITING_PASSIVE_CTS

XHCP_ACTIVE_DCD_PREVENTS_ACK_TX

XHCP_ACTIVE_DCD_PREVENTS_NAK_TX

ADLP-80 Protocol Status Codes

16250

16251

16252

ADCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

ADCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

ADCP_TIMEOUT_WHILE_WAITING_CTS

ADLP-180 Protocol Status Codes

16270

16271

16272

ALCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

ALCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

ALCP_TIMEOUT_WHILE_WAITING_CTS

RP570 Slave Protocol Status Codes

16280

16281

16282

RPCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

RPCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

RPCP_TIMEOUT_WHILE_WAITING_CTS

RAM Protocol Status Codes

16301 RMTP_MESSAGE_RESPONDED_TO_BY_NAK

1. NET has no free message buffer for the message sent by

MicroSCADA. This is not an error situation, only an occasional overload situation. A new at-tempt after a while may succeed.

2. MicroSCADA has no free memory for the message sent by NET.

104

ABB Automation

1MRS751251-MEN

3.3.42

3.3.43

3.3.44

3.3.45

3.3.46

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

16302 RMTP_TIMEOUT_WHILE_WAITING_ACK line in NET is raised with one

16303 RMTP_NET_NOT_RUNNING

Integrated Link Status Codes

16311

16312

16313

ILTP_MESSAGE_RESPONDED_TO_BY_NAK

ILTP_TIMEOUT_WHILE_WAITING_ACK

ILTP_NET_NOT_RUNNING

LN protocol status codes

16320

16321

16325

16326

16327

LNTP_SENDING_FAILED

Internal use only.

LNTP_NO_LOCAL_CONNECTION

Line is out of use since local connection has failed.

LNRP_ALLOCATION_FAILED

Line is out of use since dynamic data allocation has failed.

LNRP_LISTEN_PORT_USED

Line is out of use since the listen socket creation failed.

LNRP_LOCAL_CONNECTION_OK

Local connection has been succesfully created.

ASCII Protocol Status Codes

XY protocol errors in NET

16604

16605

16606

16607

16608

16609

16610

On Line Configuration Errors Detected by NETC Modules

16600

16601

16602

16603

NETC_DATA_OUT_OF_LIMITS_IN_CONFIG_WRITE

NETC_DC_COUNTERS_FOR_NET_NOT_IMPLEMENTED

NETC_DIAGNOSTIC_COUNTER_INDEX_TOO_LARGE

NETC_DIAGNOSTIC_COUNTER_INDEX_TOO_SMALL

Does not apply for the VMS operating system.

NETC_ERROR_IN_MESSAGE_DATA_FORMAT

NETC_IU_ALREADY_CLEARED

NETC_IU_ALREADY_SET

NETC_LAST_INDEX_SMALLER_THAN_FIRST

NETC_LINE_DOES_NOT_EXIST

NETC_LINE_NUMBER_OUT_OF_RANGE

NETC_LINE_MUST_BE_STOPPED_FIRST

105

MicroSCADA

3 Status Codes

106

Status Codes

Technical Reference Manual

1MRS751251-MEN

16639

16640

16641

16642

16643

16644

16645

16631

16632

16633

16634

16635

16636

16637

16638

16619

16620

16621

16622

16623

16624

16625

16626

16611

16612

16613

16614

16615

16616

16617

16618

16627

16628

16629

16630

NETC_MESSAGE_DATA_STRUCTURE_ERROR

NETC_MI_ATTRIBUTE_INDEX_TOO_LARGE

NETC_MI_ATTRIBUTE_INDEX_TOO_SMALL

NETC_MS_ATTRIBUTE_VALUE_OUT_OF_RANGE

NETC_NN_EXCEEDS_MAX_PHYSICAL_NET_NUMBER

NETC_NO_APPLICATION_PROCESS_PRESENT

NETC_NO_DATA_ITEMS_IN_MESSAGE

NETC_OLD_PROTOCOL_MUST_BE_RESET_FIRST

NETC_SA_ATTRIBUTE_VALUE_OUT_OF_RANGE

NETC_STATION_ADDRESS_ALREADY_IN_USE

NETC_SUGGESTED_NAME_ALREADY_IN_USE

NETC_SYS_MUST_BE_CONFIGURED_FIRST

NETC_TL_ATTRIBUTE_NOT_YET_IMPLEMENTED

NETC_UNKNOWN_ATTRIBUTE

NETC_ZERO_NOT_ALLOWED_AS_FIRST_INDEX

NETC_ZERO_TRANSLATION_LIMIT_NOT_ALLOWED

NETC_ATTRIBUTE_NOT_YET_IMPLEMENTED

NETC_ERROR_IN_MESSAGE_INDEX_RANGE

NETC_LINE_BUFFER_ATTR_INDEX_TOO_SMALL

NETC_LINE_BUFFER_ATTR_INDEX_TOO_LARGE

Does not apply for the VMS operating system.

NETC_INVALID_MA_INDEX

NETC_INVALID_MU_INDEX

NETC_MAIL_UPDATED

NETC_TRANSLATION_LIMIT_TOO_LARGE

NETC_CS_IMPLEMENTED_FOR_XH_PROTOCOL_ONLY

NETC_INVALID_SE_VALUE

NETC_PROGRAM_RESTART_NOT_IMPLEMENTED

NETC_UNDEFINED_NET_CONNECTION

NETC_NET_CONNECTION_NR_OUT_OF_RANGE

NETC_NOT_ATTRIBUTE_OF_CURRENT_PROTOCOL

NETC_MESSAGE_NOT_LEFT_IN_QUEUE

NETC_RETRANSMISSION_ALREADY_ACTIVE

NETC_INVALID_ED_INDEX

NETC_INVALID_TIME

NETC_INVALID_ME_WRITE_COMMAND

ABB Automation

1MRS751251-MEN

3.3.47

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

16646

16647

16648

16649

16650

NETC_NO_PRIVILEGE_FOR_THIS_OPERATION

NETC_SIGNAL_WRITE_NOT_ALLOWED

NETC_INVALID_SG_ATTRIBUTE_VALUE

NETC_SIGNAL_NOT_READABLE

NETC_NOT_IMPLEMENTED_IN_NT

Auto-Dialling Status Codes

16700

16701

16702

16703

16704

16705

16706

16707

16708

16709

16710

16711

16712

16713

16714

ACEP_NO_ANSWER_FROM_ACE

The autocaller device does not give an acceptable reply within a certain time in spite of repeated sendings.

ACEP_ERROR_FROM_ACE

An ERROR reply has been received from the autocaller.

ACEP_DISCONNECTION_FAILED

ACEP_PHYSICAL_DISCONNECTION_FAILED

From the ACE has been received an ERROR reply, an undefined reply or no reply to a connection break command. The ACE process is set into

IDLE state.

ACEP_DIALING_FAILED

No contact arising, although the dialling may be OK. ACE has answered to the dialling command by the reply NO CARRIER (3), ERROR (4) or with an undefined reply, or the ACE has not answered at all.

ACEP_UNKNOWN_ACE_ATTRIBUTE

ACEP_CONNECTION_LIMIT_NOT_BOOLEAN

The CL attribute has been assigned an unallowed value. Allowed values are 0 and 1.

ACEP_ACE_LINE_IN_USE

The attributes may not be updated while the line is in use.

ACEP_INVALID_CONNECTION_TIME

The CT attribute may not be given a negative value.

ACEP_INVALID_RADIO_WAIT_TIME

The RW attribute may not be given a negative value.

ACEP_PULSE_DIAL_NOT_BOOLEAN

The PU attribute has been assigned an unallowed value. Allowed values are 0 and 1.

ACEP_INVALID_S_REGISTER_VALUE

ACEC_ZERO_NOT_ALLOWED_AS_FIRST_INDEX

ACEC_S_REGISTER_INDEX_TOO_SMALL

ACEC_S_REGISTER_INDEX_TOO_LARGE

The number of the S register is > 12.

107

MicroSCADA

3 Status Codes

3.3.48

108

Status Codes

Technical Reference Manual

1MRS751251-MEN

16750

16751

16752

16753

16754

16755

16715

16716

16717

16718

16719

16720

16721

16722

16723

16724

16725

16726

16727

16728

ACEC_LINE_NUMBER_OUT_OF_RANGE

ACEC_LAST_INDEX_SMALLER_THAN_FIRST

ACEC_S_REGISTERS_FOR_NET_NOT_IMPLEMENTED

ACEC_LINE_DOES_NOT_EXIST

ACEC_AS_ATTRIBUTE_IS_READ_ONLY

ACEP_LINE_AND_ATTRIBUTES_NOT_INITIALIZED

ACEC_YOU_CANNOT_CHANGE_THE_FIRST_REGISTER

ACEC_ESCAPE_CHAR_NOT_AN_ASCII_CODE

"Unallowed ESCAPE character. Allowed values are the ASCII codes (0

... 127). The NET programs use the default ( ""+"" = 43), and if this is changed, NET cannot break the connection."

ACEC_YOU_CANNOT_CHANGE_THE_THIRD_REGISTER

ACEC_YOU_CANNOT_CHANGE_THE_FOURTH_REGISTER

ACEC_YOU_CANNOT_CHANGE_THE_FIFTH_REGISTER

ACEC_DIALING_TONE_WAIT_OUT_OF_RANGE

Illegal wait time for the dialling tone. Allowed values are 1 . . 255 seconds (default is 2).

ACEC_CARRIER_WAVE_WAIT_OUT_OF_RANGE

Illegal for the carrier wave. Allowed values are 1 . . 255 seconds (default is 30).

ACEC_DIALING_DELAY_OUT_OF_RANGE

Illegal length of delay caused by the delay character. Allowed values are

1 . . 255 seconds. Default = 2.

16729

16730

16731

16732

16733

16734

16735

ACEC_CARRIER_DETECTION_DELAY_OUT_OF_RANGE

ACEC_BREAK_DOWN_DELAY_OUT_OF_RANGE

ACEC_LENGTH_OF_MARK_AND_SPACE_TONE_NOT_OK

ACEC_ESCAPE_FRAME_DELAY_OUT_OF_RANGE

ACEP_LINE_IDLE

ACEP_INVALID_RADIO_DISCONNECTION_DELAY

ACEP_NO_MODEM_COMMAND_REPLY

CO Protocol Errors in NET

COPC_COM1_ERROR_WHILE_TRANSMITTING

COPC_COM1_ERROR_WHILE_WAITING_ACK

COPC_COM1_ERROR_WHILE_RECEIVING_ACK

COPC_COM1_ERROR_DURING_COLLISION

COPC_BUFFER_ERROR_DURING_COLLISION

COPC_TOO_MANY_COLLISIONS

ABB Automation

1MRS751251-MEN

3.3.49

3.3.50

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

16756

16757

16758

16759

COPC_MESSAGE_RESPONDED_TO_BY_NAK

COPC_TIMEOUT_WHILE_TRANSMITTING

COPC_TIMEOUT_WHILE_WAITING_ACK

COPC_TIMEOUT_WHILE_RECEIVING_ACK

SRC 570 Protocol Status Codes

16817

16818

16819

16820

16821

16822

16823

16824

16825

16826

16827

16809

16810

16811

16812

16813

16814

16815

16816

16801

16802

16803

16804

16805

16806

16807

16808

P214 Protocol Status Codes

SRCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

SRCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

SRCP_TIMEOUT_WHILE_WAITING_CTS

SRCP_RTU_NOT_ON_THIS_LINE

SRCP_FAILED_TO_DELIVER_RESPONSE

SRCP_REDUNDANCY_ERRORS_IN_RESPONSE

SRCP_RECEIVE_ERRORS_IN_RESPONSE

SRCP_TIMEOUT_WHILE_WAITING_RESPONSE

SRCP_TIMEOUT_WHILE_WAITING_APPL_ACK

SRCP_LINE_PASSIVATED

SRCP_LINE_IS_PASSIVE

SRCP_BUILD_UP_READY

SRCP_LOOP_CONFIGURATION_FAILED

SRCP_READ_NOT_ALLOWED_HERE

SRCP_INVALID_ATTRIBUTE_VALUE

SRCP_ERROR_IN_APPLICATION_QUEUE

SRCP_NEW_CONFIGURATION_MUST_FIRST_BE_LOADED

SRCP_ONLY_START_OF_BUILD_ALLOWED_HERE

SRCP_ONLY_STOP_COMMAND_ALLOWED_HERE

SRCP_ONLY_STOP_BREAK_DOWN_ALLOWED_HERE

SRCP_LINE_MUST_BE_IN_LOOP_MODE

SRCP_TRANSMISSION_BLOCKED

SRCP_UNKNOWN_SR_PROTOCOL_MODE

SRCP_NOT_LINE_WITH_SR_PROTOCOL

SRCP_LINE_ACTIVATED_BY_LOCAL

SRCP_LINE_ACTIVATED_BY_REMOTE

SRCP_COMMAND_TO_INOPERABLE_RTU

16851

16852

PRCP_DST_STATION_NOT_ON_THIS_LINE

PRCP_RESPONSE_BUFFER_NOT_READY

109

MicroSCADA

3 Status Codes

3.3.51

3.3.52

3.3.53

3.3.54

110

Status Codes

Technical Reference Manual

1MRS751251-MEN

16853

16854

16855

16856

16857

16858

16859

16860

16861

PRCP_WAITING_CTS_TIMEOUT

PRCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

PRCP_ALTERNATING_BIT_ERROR

PRCP_BUFFER_NOT_READY

PRCP_CTS_LINE_IS_CONTINUOSLY_INACTIVE

PRCP_REDUNDANCY_ERRORS_IN_RESPONSE

PRCP_RECEIVE_ERRORS_IN_RESPONSE

PRCP_DST_STATION_BLOCKED

PRCP_INVALID_ATTRIBUTE_VALUE

TC57 Protocol Status Codes

16901 TCPC_INVALID_ATTRIBUTE_VALUE

IS Protocol Status Codes

16950

16951

16952

16953

16954

16955

16956

ISCP_ACTIVE_BAG_NOT_FOUND

ISCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

ISCP_REDUNDANCY_ERRORS_IN_RESPONSE

ISCP_RX_ERRORS_IN_RESPONSE

ISCP_CTS_LINE_IS_CONTINUOSLY_INACTIVE

ISCP_WAITING_CTS_TIMEOUT

ISCP_BUFFER_NOT_READY

CL Protocol Status Codes

17001

17002

17003

17004

CLCP_REPLY_MESSAGE_NOT_ACCEPTED

CLCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

CLCP_BUFFER_NOT_READY

CLCP_WAITING_CTS_TIMEOUT

LC Protocol Status Codes

17101

17102

17103

17104

17105

17107

17108

17109

LCCP_LCU_NOT_ON_THIS_LINE

LCCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

LCCP_TIMEOUT_WHILE_WAITING_RESPONSE

LCCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

LCCP_TIMEOUT_WHILE_WAITING_APPL_ACK

LCCP_TIMEOUT_WHILE_WAITING_CTS

LCCP_REDUNDANCY_ERRORS_IN_RESPONSE

LCCP_RECEIVE_ERRORS_IN_RESPONSE

ABB Automation

1MRS751251-MEN

3.3.55

3.3.56

3.3.57

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

17110

17111

17112

17113

LCPC_OUT_OF_MESSAGE_BUFFERS

LCPC_INVALID_ATTRIBUTE_VALUE

LCPC_UNKNOWN_PROTOCOL_MODE

LCPC_NOT_LINE_WITH_LC_PROTOCOL

AM Protocol Status Codes

17151

17152

17153

17154

17155

17156

17157

17158

AMCP_RTU_NOT_ON_THIS_LINE

AMCP_TIMEOUT_WHILE_WAITING_CTS

AMCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

AMCP_REDUNDANCY_ERRORS_IN_RESPONSE

AMCP_RECEIVE_ERRORS_IN_RESPONSE

AMCP_TIMEOUT_WHILE_WAITING_RESPONSE

AMCP_TIMEOUT_WHILE_WAITING_APPL_ACK

AMCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

SP Protocol Status Codes

17251

17252

17253

17254

17255

17256

17257

17258

17259

17260

17201

17202

17203

17204

17205

17230

17231

17232

17233

SPCP_TIMEOUT_WHILE_WAITING_CTS

SPCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

SPCP_REDUNDANCY_ERRORS_IN_RESPONSE

SPCP_TIMEOUT_WHILE_WAITING_RESPONSE

SPCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

SPPC_INVALID_ATTRIBUTE_VALUE

SPPC_ERROR_IN_MESSAGE_DATA_FORMAT

SPPC_INVALID_LINE_NUMBER

SPPC_LINE_DOES_NOT_EXIST

AG Protocol Status Codes

AGCP_BUFFER_NOT_READY

AGPC_UNKNOWN_ASCII_PROTOCOL_MODE

AGPC_NOT_LINE_WITH_AG_PROTOCOL

AGPC_TELEGRAM_LENGTH_PARAMETER_ERROR

AGPC_TELEGRAM_FRAME_LENGTH_PARAM_ERROR

AGCP_SYNC_RECEIVED

AGCP_SYNC_MESSAGE_REJECTED

AGPC_INVALID_CLOCK_SYNC_FORMAT

AGPC_MASTER_CLOCK_NOT_SYNCHRONIZED

AGCP_NO_MESSAGE_RECEIVED

111

MicroSCADA

3 Status Codes

3.3.58

3.3.59

3.3.60

3.3.61

112

Status Codes

Technical Reference Manual

1MRS751251-MEN

PC Protocol Status Codes

17301

17302

17303

17304

17305

17306

17307

17326

17327

PCCP_TIMEOUT_WHILE_WAITING_CTS

PCCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

PCCP_REDUNDANCY_ERRORS_IN_RESPONSE

PCCP_TIMEOUT_WHILE_WAITING_RESPONSE

PCCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

PCCP_RECEIVE_ERRORS_IN_RESPONSE

PCCP_STATION_NOT_ON_THIS_LINE

PCPC_UNKNOWN_PC_PROTOCOL_MODE

PCPC_NOT_LINE_WITH_PC_PROTOCOL

WE Protocol Status Codes

17351

17352

17353

17354

WECP_REPLY_MESSAGE_NOT_ACCEPTED

WECP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

WECP_BUFFER_NOT_READY

WECP_WAITING_CTS_TIMEOUT

AT Protocol Status Codes

17450

17451

17452

17453

17454

17455

17401

17402

17403

17404

17405

17406

17407

17408

17409

17410

ATCP_APLHA_CONNECTED

ATCP_SESSION_STOPPED

ATCP_SESSION_ABORTTED

ATCP_BUFFER_NOT_READY

ATCP_ERR_REPLY_FROM_ALPHA

ATCP_NO_REPLY_FROM_ALPHA

ATCP_SESSION_READY

ATCP_HANDSHAKING_FAILED

ATCP_LINE_PASSIVATED

ATCP_MODEM_CONNECTED

IE Protocol Status Codes

IECP_SESSION_READY

IECP_SESSION_ABORTED

IECP_LINE_PASSIVATED

IECP_BUFFER_NOT_READY

IECP_ERR_REPLY_FROM_DEVICE

IECP_NO_REPLY_FROM_DEVICE

ABB Automation

1MRS751251-MEN

3.3.62

3.3.63

3.3.64

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

17456

17457

17458

IECP_SESSION_STOPPED

IECP_SESSION_ENDS_TO_CTS_ERROR

IECP_CONNECTION_ESTABILISHED

PG Protocol Status Codes

17500

17501

17502

17503

17504

17505

17506

17507

17508

17509

PGCP_TIMEOUT_WHILE_WAITING_CTS

PGCP_CTS_LINE_FAILURE_WHILE_TRANSMITTING

PGCP_BUFFER_NOT_READY

PGCP_CTS_LINE_IS_CONTINUOUSLY_INACTIVE

PGCP_REDUNDANCY_ERRORS_IN_RESPONSE

PGCP_TIMEOUT_WHILE_WAITING_RESPONSE

PGCP_LINE_PASSIVATED

PGCP_LINE_ACTIVATED_BY_LOCAL

PGCP_LINE_ACTIVATED_BY_REMOTE

PGCP_LINE_IS_PASSIVE

LO Protocol Status Codes

17550

17551

17552

17553

17554

17555

17556

LOCP_OPEN_FAILED_WITH_INVALID_HANDLE

LOPC_CLOSE_FAILED

LOPC_INVALID_ATTR_VALUE

LOPC_INVALID_ATTR_INDEX

LOPC_INVALID_LINE_NUMBER

LOPC_LINE_DOES_NOT_EXIST

LOPC_NV_INDEX_NOT_CONFIGURED

IEC Protocol Status Codes

17600

17601

17602

17603

IGTP_REMOTE_LINK_CONTINUOUSLY_BUSY

The Data Flow Control bit of the messages from the master is set for more than 15 seconds.

IGTP_TIMEOUT_WHILE_TRANSMITTING

The CTS signal or the end of transmitted message is not received in correct time. The attribute DE controls CTS waiting time, the transmit time of message is automatically calculated.

IGTP_TIMEOUT_WHILE_WAITING_RESPONSE

Timeout while waiting for an acknowledgement to a message.

IGTP_LINK_INITIALIZING

ABB Automation

113

MicroSCADA

3 Status Codes

3.3.65

114

Status Codes

Technical Reference Manual

1MRS751251-MEN

17604

17605

17606

17607

17608

17609

17610

17611

17612

17620

IGTP_LINK_NOT_READY

The application level sends a command before the communication between the master and the slave is established.

IGTP_REMOTE_LINK_BUSY

Data sending fails since the Data Flow Control bit (DFC) is set in remote station and there is already one data message waiting for its reset. Not used in unbalanced slave.

IGTP_REMOTE_LINK_NOT_RESPONDING

The slave does not receive a reply from the master.

IGTP_LINE_STARTED

The station has been set in use by using the IU attribute.

IGTP_LINE_STOPPED

The station has been set out of use by using the IU attribute.

IGTP_MESSAGE_RECEIVING_STOPPED

IGTP_RECEIVER_OUT_OF_BUFFERS

Internal software error. This error can for example occur in a situation where the station is set out of use but commands are received from the master.

IGTP_LINE_PASSIVATED

The autodialling system controls the line. IEC communication is possible not until the line is activated with a call.

IGTP_LINE_ACTIVATED

The line is activated by the autodialling system, but the handshaking sequence between master and slave is not yet ready.

IGPC_ILLEGAL_ATTRIBUTE_VALUE

The value written to one of the line attributes is incorrect.

DNP Protocol Status Codes

17650

17651

17652

17654

DGTP_REMOTE_LINK_CONTINUOUSLY_BUSY

The Data Flow Control bit of the messages from the master is set for more than 15 seconds.

DGTP_TIMEOUT_WHILE_TRANSMITTING

The DCD or CTS signal or the end of transmitted message is not received in correct time. The attribute DE controls CTS waiting time, the attribute

TI the message time and DCD waiting time is constant.

DGTP_TIMEOUT_WHILE_WAITING_RESPONSE

Timeout while waiting for an acknowledgement to a request.

DGTP_LINK_NOT_READY

The application level sends a command before the communication between the master and the slave is established.

ABB Automation

1MRS751251-MEN

3.3.66

3.3.67

3.3.68

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

17655

17656

17657

17658

17659

17670

17700

DGTP_REMOTE_STATION_BUSY

The Data Flow Control bit of the messages from the master is set for too long.

DGTP_REMOTE_STATION_NOT_RESPONDING

The salve does not receive a reply from the master.

DGTP_LINE_STARTED

The station has been set in use using the IU attribute.

DGTP_LINE_STOPPED

The line has been set out of use using the IU attribute.

DGTP_RECEIVER_OUT_OF_BUFFERS

Internal software error.

DGPC_ILLEGAL_ATTRIBUTE_VALUE

The value written to one of the line attributes is incorrect.

DCPC_INVALID_ATTRIBUTE_VALUE

The value written to one of the line attributes is of wrong data type.

LN protocol status codes

17750

17751

17752

LNPC_NONACCEPTABLE_HOSTNAME

The given hostname is too long.

LNPC_NOT_LINE_WITH_LN_PROTOCOL

Hostname configuration impossible since the TCP/IP is has not yet been created.

LNPC_CONFIGURATION_FAILED

The starting of the configuration thread failed.

PLC Related Status Codes

20000

20002

PLC2_STATUS_BIAS

PLC_DOES_NOT_RESPOND

PLC Status Codes

20016

20048

20064

PLC2_INVALID_CMD_OR_FNC_OR_SIZE_BYTE

The station does not accept the used data type.

PLC2_PROCESSOR_FAULTY_OR_DISCONNECTED

PLC2_INTERFACE_PROCESSOR_COMM_FAILED

The communication unit of the PLC does not get contact to the processor of the PLC.

ABB Automation

115

MicroSCADA

3 Status Codes

3.4

3.4.1

116

Status Codes

Technical Reference Manual

1MRS751251-MEN

20080

20096

PLC2_ACCESS_DENIED

You have tried to write to a station by a protected write command, but there is no corresponding ACCESS RUNG in the PLC program.

PLC2_EXECUTION_PREVENTED_BY_SWITCHES

The switch settings of the PLC communication unit prevent the command execution. The reason may be that an unprotected write command has been used, but the switch PHYSICAL/UNPROTECTED WRITE is in

DISABLED state.

20112

20128

20144

20176

PLC2_STATION_IN_PROGRAM_MODE

PLC2_STATION_IN_ERROR_SHUTDOWN_MODE

PLC2_INTERFACE_MODULE_OUT_OF_BUF_SPACE

PLC2_STATION_IN_DOWNLOAD_MODE

Operating System Status Codes

Win32 Error Codes

0

1

2

3

4

5

6

7

8

9

10

ERROR_SUCCESS

The operation completed successfully.

ERROR_INVALID_FUNCTION

Incorrect function.

ERROR_FILE_NOT_FOUND

The system cannot find the file specified.

ERROR_PATH_NOT_FOUND

The system cannot find the path specified.

ERROR_TOO_MANY_OPEN_FILES

The system cannot open the file.

ERROR_ACCESS_DENIED

Access is denied.

ERROR_INVALID_HANDLE

The handle is invalid.

ERROR_ARENA_TRASHED

The storage control blocks were destroyed.

ERROR_NOT_ENOUGH_MEMORY

Not enough storage is available to process this command.

ERROR_INVALID_BLOCK

The storage control block address is invalid.

ERROR_BAD_ENVIRONMENT

The environment is incorrect.

ABB Automation

1MRS751251-MEN

ABB Automation

25

26

23

24

27

28

21

22

19

20

17

18

15

16

13

14

11

12

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_BAD_FORMAT

An attempt was made to load a program with an incorrect format.

ERROR_INVALID_ACCESS

The access code is invalid.

ERROR_INVALID_DATA

The data is invalid.

ERROR_OUTOFMEMORY

Not enough storage is available to complete this operation.

ERROR_INVALID_DRIVE

The system cannot find the drive specified.

ERROR_CURRENT_DIRECTORY

The directory cannot be removed.

ERROR_NOT_SAME_DEVICE

The system cannot move the file to a different disk drive.

ERROR_NO_MORE_FILES

There are no more files.

ERROR_WRITE_PROTECT

The media is write protected.

ERROR_BAD_UNIT

The system cannot find the device specified.

ERROR_NOT_READY

The device is not ready.

ERROR_BAD_COMMAND

The device does not recognize the command.

ERROR_CRC

Data error (cyclic redundancy check).

ERROR_BAD_LENGTH

The program issued a command but the command length is incorrect.

ERROR_SEEK

The drive cannot locate a specific area or track on the disk.

ERROR_NOT_DOS_DISK

The specified disk or diskette cannot be accessed.

ERROR_SECTOR_NOT_FOUND

The drive cannot find the sector requested.

ERROR_OUT_OF_PAPER

The printer is out of paper.

117

MicroSCADA

3 Status Codes

118

31

32

29

30

33

34

52

53

50

51

36

38

39

56

57

54

55

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_WRITE_FAULT

The system cannot write to the specified device.

ERROR_READ_FAULT

The system cannot read from the specified device.

ERROR_GEN_FAILURE

A device attached to the system is not functioning.

ERROR_SHARING_VIOLATION

The process cannot access the file because it is being used by another process.

ERROR_LOCK_VIOLATION

The process cannot access the file because another process has locked a portion of the file.

ERROR_WRONG_DISK

The wrong diskette is in the drive. Insert %2 (Volume Serial Number:

%3) into drive %1.

ERROR_SHARING_BUFFER_EXCEEDED

Too many files opened for sharing.

ERROR_HANDLE_EOF

Reached the end of the file.

ERROR_HANDLE_DISK_FULL

The disk is full.

ERROR_NOT_SUPPORTED

The network request is not supported.

ERROR_REM_NOT_LIST

The remote computer is not available.

ERROR_DUP_NAME

A duplicate name exists on the network.

ERROR_BAD_NETPATH

The network path was not found.

ERROR_NETWORK_BUSY

The network is busy.

ERROR_DEV_NOT_EXIST

The specified network resource or device is no longer available.

ERROR_TOO_MANY_CMDS

The network BIOS command limit has been reached.

ERROR_ADAP_HDW_ERR

A network adapter hardware error occurred.

ABB Automation

1MRS751251-MEN

ABB Automation

69

70

71

72

80

82

64

65

62

63

60

61

58

59

66

67

68

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_BAD_NET_RESP

The specified server cannot perform the requested operation.

ERROR_UNEXP_NET_ERR

An unexpected network error occurred.

ERROR_BAD_REM_ADAP

The remote adapter is not compatible.

ERROR_PRINTQ_FULL

The printer queue is full.

ERROR_NO_SPOOL_SPACE

Space to store the file waiting to be printed is not available on the server.

ERROR_PRINT_CANCELLED

Your file waiting to be printed was deleted.

ERROR_NETNAME_DELETED

The specified network name is no longer available.

ERROR_NETWORK_ACCESS_DENIED

Network access is denied.

ERROR_BAD_DEV_TYPE

The network resource type is not correct.

ERROR_BAD_NET_NAME

The network name cannot be found.

ERROR_TOO_MANY_NAMES

The name limit for the local computer network adapter card was exceeded.

ERROR_TOO_MANY_SESS

The network BIOS session limit was exceeded.

ERROR_SHARING_PAUSED

The remote server has been paused or is in the process of being started.

ERROR_REQ_NOT_ACCEP

No more connections can be made to this remote computer at this time because there are already as many connections as the computer can accept.

ERROR_REDIR_PAUSED

The specified printer or disk device has been paused.

ERROR_FILE_EXISTS

The file exists.

ERROR_CANNOT_MAKE

The directory or file cannot be created.

119

MicroSCADA

3 Status Codes

120

105

106

107

108

101

102

103

104

109

110

87

88

89

100

85

86

83

84

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_FAIL_I24

Fail on INT 24.

ERROR_OUT_OF_STRUCTURES

Storage to process this request is not available.

ERROR_ALREADY_ASSIGNED

The local device name is already in use.

ERROR_INVALID_PASSWORD

The specified network password is not correct.

ERROR_INVALID_PARAMETER

The parameter is incorrect.

ERROR_NET_WRITE_FAULT

A write fault occurred on the network.

ERROR_NO_PROC_SLOTS

The system cannot start another process at this time.

ERROR_TOO_MANY_SEMAPHORES

Cannot create another system semaphore.

ERROR_EXCL_SEM_ALREADY_OWNED

The exclusive semaphore is owned by another process.

ERROR_SEM_IS_SET

The semaphore is set and cannot be closed.

ERROR_TOO_MANY_SEM_REQUESTS

The semaphore cannot be set again.

ERROR_INVALID_AT_INTERRUPT_TIME

Cannot request exclusive semaphores at interrupt time.

ERROR_SEM_OWNER_DIED

The previous ownership of this semaphore has ended.

ERROR_SEM_USER_LIMIT

Insert the diskette for drive %1.

ERROR_DISK_CHANGE

The program stopped because an alternate diskette was not inserted.

ERROR_DRIVE_LOCKED

The disk is in use or locked by another process.

ERROR_BROKEN_PIPE

The pipe has been ended.

ERROR_OPEN_FAILED

The system cannot open the device or file specified.

ABB Automation

1MRS751251-MEN

ABB Automation

126

127

128

129

130

121

122

124

125

117

118

119

120

111

112

113

114

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_BUFFER_OVERFLOW

The file name is too long.

ERROR_DISK_FULL

There is not enough space on the disk.

ERROR_NO_MORE_SEARCH_HANDLES

No more internal file identifiers available.

ERROR_INVALID_TARGET_HANDLE

The target internal file identifier is incorrect.

ERROR_INVALID_CATEGORY

The IOCTL call made by the application program is not correct.

ERROR_INVALID_VERIFY_SWITCH

The verify-on-write switch parameter value is not correct.

ERROR_BAD_DRIVER_LEVEL

The system does not support the command requested.

ERROR_CALL_NOT_IMPLEMENTED

This function is not supported on this system.

ERROR_SEM_TIMEOUT

The semaphore timeout period has expired.

ERROR_INSUFFICIENT_BUFFER

The data area passed to a system call is too small.

ERROR_INVALID_LEVEL

The system call level is not correct.

ERROR_NO_VOLUME_LABEL

The disk has no volume label.

ERROR_MOD_NOT_FOUND

The specified module could not be found.

ERROR_PROC_NOT_FOUND

The specified procedure could not be found.

ERROR_WAIT_NO_CHILDREN

There are no child processes to wait for.

ERROR_CHILD_NOT_COMPLETE

The %1 application cannot be run in Win32 mode.

ERROR_DIRECT_ACCESS_HANDLE

Attempt to use a file handle to an open disk partition for an operation other than raw disk I/O.

121

MicroSCADA

3 Status Codes

122

131

132

133

134

135

136

137

144

145

146

138

139

140

141

142

143

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_NEGATIVE_SEEK

An attempt was made to move the file pointer before the beginning of the file.

ERROR_SEEK_ON_DEVICE

The file pointer cannot be set on the specified device or file.

ERROR_IS_JOIN_TARGET

A JOIN or SUBST command cannot be used for a drive that contains previously joined drives.

ERROR_IS_JOINED

An attempt was made to use a JOIN or SUBST command on a drive that has already been joined.

ERROR_IS_SUBSTED

An attempt was made to use a JOIN or SUBST command on a drive that has already been substituted.

ERROR_NOT_JOINED

The system tried to delete the JOIN of a drive that is not joined.

ERROR_NOT_SUBSTED

The system tried to delete the substitution of a drive that is not substituted.

ERROR_JOIN_TO_JOIN

The system tried to join a drive to a directory on a joined drive.

ERROR_SUBST_TO_SUBST

The system tried to substitute a drive to a directory on a substituted drive.

ERROR_JOIN_TO_SUBST

The system tried to join a drive to a directory on a substituted drive.

ERROR_SUBST_TO_JOIN

The system tried to SUBST a drive to a directory on a joined drive.

ERROR_BUSY_DRIVE

The system cannot perform a JOIN or SUBST at this time.

ERROR_SAME_DRIVE

The system cannot join or substitute a drive to or for a directory on the same drive.

ERROR_DIR_NOT_ROOT

The directory is not a subdirectory of the root directory.

ERROR_DIR_NOT_EMPTY

The directory is not empty.

ERROR_IS_SUBST_PATH

The path specified is being used in a substitute.

ABB Automation

1MRS751251-MEN

ABB Automation

147

148

149

151

152

153

154

159

160

161

162

155

156

157

158

164

167

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_IS_JOIN_PATH

Not enough resources are available to process this command.

ERROR_PATH_BUSY

The path specified cannot be used at this time.

ERROR_IS_SUBST_TARGET

An attempt was made to join or substitute a drive for which a directory on the drive is the target of a previous substitute.

ERROR_INVALID_EVENT_COUNT

The number of specified semaphore events for DosMuxSemWait is not correct.

ERROR_TOO_MANY_MUXWAITERS

DosMuxSemWait did not execute; too many semaphores are already set.

ERROR_INVALID_LIST_FORMAT

The DosMuxSemWait list is not correct.

ERROR_LABEL_TOO_LONG

The volume label you entered exceeds the label character limit of the target file system.

ERROR_TOO_MANY_TCBS

Cannot create another thread.

ERROR_SIGNAL_REFUSED

The recipient process has refused the signal.

ERROR_DISCARDED

The segment is already discarded and cannot be locked.

ERROR_NOT_LOCKED

The segment is already unlocked.

ERROR_BAD_THREADID_ADDR

The address for the thread ID is not correct.

ERROR_BAD_ARGUMENTS

The argument string passed to DosExecPgm is not correct.

ERROR_BAD_PATHNAME

The specified path is invalid.

ERROR_SIGNAL_PENDING

A signal is already pending.

ERROR_MAX_THRDS_REACHED

No more threads can be created in the system.

ERROR_LOCK_FAILED

Unable to lock a region of a file.

123

MicroSCADA

3 Status Codes

124

192

193

194

195

188

189

190

191

196

197

182

183

186

187

170

173

174

180

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_BUSY

The requested resource is in use.

ERROR_CANCEL_VIOLATION

A lock request was not outstanding for the supplied cancel region.

ERROR_ATOMIC_LOCKS_NOT_SUPPORTED

The file system does not support atomic changes to the lock type.

ERROR_INVALID_SEGMENT_NUMBER

The system detected a segment number that was not correct.

ERROR_INVALID_ORDINAL

The operating system cannot run %1.

ERROR_ALREADY_EXISTS

Cannot create a file when that file already exists.

ERROR_INVALID_FLAG_NUMBER

The flag passed is not correct.

ERROR_SEM_NOT_FOUND

The specified system semaphore name was not found.

ERROR_INVALID_STARTING_CODESEG

The operating system cannot run %1.

ERROR_INVALID_STACKSEG

The operating system cannot run %1.

ERROR_INVALID_MODULETYPE

The operating system cannot run %1.

ERROR_INVALID_EXE_SIGNATURE

Cannot run %1 in Win32 mode.

ERROR_EXE_MARKED_INVALID

The operating system cannot run %1.

ERROR_BAD_EXE_FORMAT

%1 is not a valid Win32 application.

ERROR_ITERATED_DATA_EXCEEDS_64k

The operating system cannot run %1.

ERROR_INVALID_MINALLOCSIZE

The operating system cannot run %1.

ERROR_DYNLINK_FROM_INVALID_RING

The operating system cannot run this application program.

ERROR_IOPL_NOT_ENABLED

The operating system is not presently configured to run this application.

ABB Automation

1MRS751251-MEN

ABB Automation

215

230

231

232

202

203

205

206

198

199

200

201

207

209

210

212

214

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_INVALID_SEGDPL

The operating system cannot run %1.

ERROR_AUTODATASEG_EXCEEDS_64k

The operating system cannot run this application program.

ERROR_RING2SEG_MUST_BE_MOVABLE

The code segment cannot be greater than or equal to 64K.

ERROR_RELOC_CHAIN_XEEDS_SEGLIM

The operating system cannot run %1.

ERROR_INFLOOP_IN_RELOC_CHAIN

The operating system cannot run %1.

ERROR_ENVVAR_NOT_FOUND

The system could not find the environment option that was entered.

ERROR_NO_SIGNAL_SENT

No process in the command subtree has a signal handler.

ERROR_FILENAME_EXCED_RANGE

The filename or extension is too long.

ERROR_RING2_STACK_IN_USE

The ring 2 stack is in use.

ERROR_INVALID_SIGNAL_NUMBER

The signal being posted is not correct.

ERROR_THREAD_1_INACTIVE

The signal handler cannot be set.

ERROR_LOCKED

The segment is locked and cannot be reallocated.

ERROR_TOO_MANY_MODULES

Too many dynamic-link modules are attached to this program or dynamic-link module.

ERROR_NESTING_NOT_ALLOWED

Cannot nest calls to LoadModule.

ERROR_BAD_PIPE

The pipe state is invalid.

ERROR_PIPE_BUSY

All pipe instances are busy.

ERROR_NO_DATA

The pipe is being closed.

125

MicroSCADA

3 Status Codes

126

278

282

288

298

299

267

275

276

277

255

258

259

266

233

234

240

254

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_PIPE_NOT_CONNECTED

No process is on the other end of the pipe.

ERROR_MORE_DATA

More data is available.

ERROR_VC_DISCONNECTED

The session was canceled.

ERROR_INVALID_EA_NAME

The specified extended attribute name was invalid.

ERROR_EA_LIST_INCONSISTENT

The extended attributes are inconsistent.

WAIT_TIMEOUT

The wait operation timed out.

ERROR_NO_MORE_ITEMS

No more data is available.

ERROR_CANNOT_COPY

The copy functions cannot be used.

ERROR_DIRECTORY

The directory name is invalid.

ERROR_EAS_DIDNT_FIT

The extended attributes did not fit in the buffer.

ERROR_EA_FILE_CORRUPT

The extended attribute file on the mounted file system is corrupt.

ERROR_EA_TABLE_FULL

The extended attribute table file is full.

ERROR_INVALID_EA_HANDLE

The specified extended attribute handle is invalid.

ERROR_EAS_NOT_SUPPORTED

The mounted file system does not support extended attributes.

ERROR_NOT_OWNER

Attempt to release mutex not owned by caller.

ERROR_TOO_MANY_POSTS

Too many posts were made to a semaphore.

ERROR_PARTIAL_COPY

Only part of a ReadProcessMemory or WriteProcessMemory request was completed.

ABB Automation

1MRS751251-MEN

ABB Automation

300

301

317

487

534

535

536

994

995

999

1001

1002

1003

1004

996

997

998

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_OPLOCK_NOT_GRANTED

The oplock request is denied.

ERROR_INVALID_OPLOCK_PROTOCOL

An invalid oplock acknowledgment was received by the system.

ERROR_MR_MID_NOT_FOUND

The system cannot find message text for message number 0x%1 in the message file for %2.

ERROR_INVALID_ADDRESS

Attempt to access invalid address.

ERROR_ARITHMETIC_OVERFLOW

Arithmetic result exceeded 32 bits.

ERROR_PIPE_CONNECTED

There is a process on other end of the pipe.

ERROR_PIPE_LISTENING

Waiting for a process to open the other end of the pipe.

ERROR_EA_ACCESS_DENIED

Access to the extended attribute was denied.

ERROR_OPERATION_ABORTED

The I/O operation has been aborted because of either a thread exit or an application request.

ERROR_IO_INCOMPLETE

Overlapped I/O event is not in a signaled state.

ERROR_IO_PENDING

Overlapped I/O operation is in progress.

ERROR_NOACCESS

Invalid access to memory location.

ERROR_SWAPERROR

Error performing inpage operation.

ERROR_STACK_OVERFLOW

Recursion too deep; the stack overflowed.

ERROR_INVALID_MESSAGE

The window cannot act on the sent message.

ERROR_CAN_NOT_COMPLETE

Cannot complete this function.

ERROR_INVALID_FLAGS

Invalid flags.

127

MicroSCADA

3 Status Codes

128

1005

1006

1010

1011

1012

1013

1014

1007

1008

1009

1018

1019

1020

1021

1022

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_UNRECOGNIZED_VOLUME

The volume does not contain a recognized file system. Please make sure that all required file system drivers are loaded and that the volume is not corrupted.

ERROR_FILE_INVALID

The volume for a file has been externally altered so that the opened file is no longer valid.

ERROR_FULLSCREEN_MODE

The requested operation cannot be performed in full-screen mode.

ERROR_NO_TOKEN

An attempt was made to reference a token that does not exist.

ERROR_BADDB

The configuration registry database is corrupt.

ERROR_BADKEY

The configuration registry key is invalid.

ERROR_CANTOPEN

The configuration registry key could not be opened.

ERROR_CANTREAD

The configuration registry key could not be read.

ERROR_CANTWRITE

The configuration registry key could not be written.

ERROR_REGISTRY_RECOVERED

One of the files in the registry database had to be recovered by use of a log or alternate copy. The recovery was successful.

ERROR_KEY_DELETED

Illegal operation attempted on a registry key that has been marked for deletion.

ERROR_NO_LOG_SPACE

System could not allocate the required space in a registry log.

ERROR_KEY_HAS_CHILDREN

Cannot create a symbolic link in a registry key that already has subkeys or values.

ERROR_CHILD_MUST_BE_VOLATILE

Cannot create a stable subkey under a volatile parent key.

ERROR_NOTIFY_ENUM_DIR

A notify change request is being completed and the information is not being returned in the caller’s buffer. The caller now needs to enumerate the files to find the changes.

ABB Automation

1MRS751251-MEN

ABB Automation

1051

1052

1053

1066

1067

1068

1062

1063

1064

1065

1057

1059

1060

1061

1054

1055

1056

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DEPENDENT_SERVICES_RUNNING

A stop control has been sent to a service that other running services are dependent on.

ERROR_INVALID_SERVICE_CONTROL

The requested control is not valid for this service.

ERROR_SERVICE_REQUEST_TIMEOUT

The service did not respond to the start or control request in a timely fashion.

ERROR_SERVICE_NO_THREAD

A thread could not be created for the service.

ERROR_SERVICE_DATABASE_LOCKED

The service database is locked.

ERROR_SERVICE_ALREADY_RUNNING

An instance of the service is already running.

ERROR_INVALID_SERVICE_ACCOUNT

The account name is invalid or does not exist.

ERROR_CIRCULAR_DEPENDENCY

Circular service dependency was specified.

ERROR_SERVICE_DOES_NOT_EXIST

The specified service does not exist as an installed service.

ERROR_SERVICE_CANNOT_ACCEPT_CTRL

The service cannot accept control messages at this time.

ERROR_SERVICE_NOT_ACTIVE

The service has not been started.

ERROR_FAILED_SERVICE_CONTROLLER_CONNECT

The service process could not connect to the service controller.

ERROR_EXCEPTION_IN_SERVICE

An exception occurred in the service when handling the control request.

ERROR_DATABASE_DOES_NOT_EXIST

The database specified does not exist.

ERROR_SERVICE_SPECIFIC_ERROR

The service has returned a service-specific error code.

ERROR_PROCESS_ABORTED

The process terminated unexpectedly.

ERROR_SERVICE_DEPENDENCY_FAIL

The dependency service or group failed to start.

129

MicroSCADA

3 Status Codes

130

1074

1075

1076

1069

1071

1072

1073

1077

1078

1079

1082

1083

1100

1101

1102

1103

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_SERVICE_LOGON_FAILED

The service did not start due to a logon failure.

ERROR_INVALID_SERVICE_LOCK

The specified service database lock is invalid.

ERROR_SERVICE_MARKED_FOR_DELETE

The specified service has been marked for deletion.

ERROR_SERVICE_EXISTS

The specified service already exists.

ERROR_ALREADY_RUNNING_LKG

The system is currently running with the last-known-good configuration.

ERROR_SERVICE_DEPENDENCY_DELETED

The dependency service does not exist or has been marked for deletion.

ERROR_BOOT_ALREADY_ACCEPTED

The current boot has already been accepted for use as the last-knowngood control set.

ERROR_SERVICE_NEVER_STARTED

No attempts to start the service have been made since the last boot.

ERROR_DUPLICATE_SERVICE_NAME

The name is already in use as either a service name or a service display name.

ERROR_DIFFERENT_SERVICE_ACCOUNT

The account specified for this service is different from the account specified for other services running in the same process.

ERROR_NO_RECOVERY_PROGRAM

No recovery program has been configured for this service.

ERROR_SERVICE_NOT_IN_EXE

The executable program that this service is configured to run in does not implement the service.

ERROR_END_OF_MEDIA

The physical end of the tape has been reached.

ERROR_FILEMARK_DETECTED

A tape access reached a filemark.

ERROR_BEGINNING_OF_MEDIA

The beginning of the tape or a partition was encountered.

ERROR_SETMARK_DETECTED

A tape access reached the end of a set of files.

ABB Automation

1MRS751251-MEN

ABB Automation

1114

1115

1116

1109

1110

1111

1112

1113

1104

1105

1107

1108

1117

1118

1119

1120

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_NO_DATA_DETECTED

No more data is on the tape.

ERROR_PARTITION_FAILURE

Tape could not be partitioned.

ERROR_DEVICE_NOT_PARTITIONED

Tape partition information could not be found when loading a tape.

ERROR_UNABLE_TO_LOCK_MEDIA

Unable to lock the media eject mechanism.

ERROR_UNABLE_TO_UNLOAD_MEDIA

Unable to unload the media.

ERROR_MEDIA_CHANGED

The media in the drive may have changed.

ERROR_BUS_RESET

The I/O bus was reset.

ERROR_NO_MEDIA_IN_DRIVE

No media in drive.

ERROR_NO_UNICODE_TRANSLATION

No mapping for the Unicode character exists in the target multi-byte code page.

ERROR_DLL_INIT_FAILED

A dynamic link library (DLL) initialization routine failed.

ERROR_SHUTDOWN_IN_PROGRESS

A system shutdown is in progress.

ERROR_NO_SHUTDOWN_IN_PROGRESS

Unable to abort the system shutdown because no shutdown was in progress.

ERROR_IO_DEVICE

The request could not be performed because of an I/O device error.

ERROR_SERIAL_NO_DEVICE

No serial device was successfully initialized. The serial driver will unload.

ERROR_IRQ_BUSY

Unable to open a device that was sharing an interrupt request (IRQ) with other devices. At least one other device that uses that IRQ was already opened.

ERROR_MORE_WRITES

A serial I/O operation was completed by another write to the serial port.

(The IOCTL_SERIAL_XOFF_COUNTER reached zero.)

131

MicroSCADA

3 Status Codes

132

1121

1122

1123

1124

1125

1129

1130

1131

1132

1140

1141

1142

1150

1151

1152

1153

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_COUNTER_TIMEOUT

A serial I/O operation completed because the timeout period expired.

(The IOCTL_SERIAL_XOFF_COUNTER did not reach zero.)

ERROR_FLOPPY_ID_MARK_NOT_FOUND

No ID address mark was found on the floppy disk.

ERROR_FLOPPY_WRONG_CYLINDER

Mismatch between the floppy disk sector ID field and the floppy disk controller track address.

ERROR_FLOPPY_UNKNOWN_ERROR

The floppy disk controller reported an error that is not recognized by the floppy disk driver.

ERROR_FLOPPY_BAD_REGISTERS

The floppy disk controller returned inconsistent results in its registers.

ERROR_EOM_OVERFLOW

Physical end of tape encountered.

ERROR_NOT_ENOUGH_SERVER_MEMORY

Not enough server storage is available to process this command.

ERROR_POSSIBLE_DEADLOCK

A potential deadlock condition has been detected.

ERROR_MAPPED_ALIGNMENT

The base address or the file offset specified does not have the proper alignment.

ERROR_SET_POWER_STATE_VETOED

An attempt to change the system power state was vetoed by another application or driver.

ERROR_SET_POWER_STATE_FAILED

The system BIOS failed an attempt to change the system power state.

ERROR_TOO_MANY_LINKS

An attempt was made to create more links on a file than the file system supports.

ERROR_OLD_WIN_VERSION

The specified program requires a newer version of Windows.

ERROR_APP_WRONG_OS

The specified program is not a Windows or MS-DOS program.

ERROR_SINGLE_INSTANCE_APP

Cannot start more than one instance of the specified program.

ERROR_RMODE_APP

The specified program was written for an earlier version of Windows.

ABB Automation

1MRS751251-MEN

ABB Automation

1154

1155

1156

1157

1158

1166

1167

1168

1169

1170

1163

1164

1165

1159

1160

1161

1162

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_INVALID_DLL

One of the library files needed to run this application is damaged.

ERROR_NO_ASSOCIATION

No application is associated with the specified file for this operation.

ERROR_DDE_FAIL

An error occurred in sending the command to the application.

ERROR_DLL_NOT_FOUND

One of the library files needed to run this application cannot be found.

ERROR_NO_MORE_USER_HANDLES

The current process has used all of its system allowance of handles for

Window Manager objects.

ERROR_MESSAGE_SYNC_ONLY

The message can be used only with synchronous operations.

ERROR_SOURCE_ELEMENT_EMPTY

The indicated source element has no media.

ERROR_DESTINATION_ELEMENT_FULL

The indicated destination element already contains media.

ERROR_ILLEGAL_ELEMENT_ADDRESS

The indicated element does not exist.

ERROR_MAGAZINE_NOT_PRESENT

The indicated element is part of a magazine that is not present.

ERROR_DEVICE_REINITIALIZATION_NEEDED

The indicated device requires reinitialization due to hardware errors.

ERROR_DEVICE_REQUIRES_CLEANING

The device has indicated that cleaning is required before further operations are attempted.

ERROR_DEVICE_DOOR_OPEN

The device has indicated that its door is open.

ERROR_DEVICE_NOT_CONNECTED

The device is not connected.

ERROR_NOT_FOUND

Element not found.

ERROR_NO_MATCH

There was no match for the specified key in the index.

ERROR_SET_NOT_FOUND

The property set specified does not exist on the object.

133

MicroSCADA

3 Status Codes

134

1171

1172

1173

1174

1175

1176

1177

1203

1204

1205

1206

1200

1201

1202

1178

1179

1181

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_POINT_NOT_FOUND

The point passed to GetMouseMovePointsEx is not in the buffer.

ERROR_NO_TRACKING_SERVICE

The tracking (workstation) service is not running.

ERROR_NO_VOLUME_ID

The Volume ID could not be found.

ERROR_INVALID_VLM_OPERATION

The specified Very Large Memory (64-bit) operation is invalid.

ERROR_UNABLE_TO_REMOVE_REPLACED

Unable to remove the file to be replaced.

ERROR_UNABLE_TO_MOVE_REPLACEMENT

Unable to move the replacement file to the file to be replaced. The file to be replaced has retained its original name.

ERROR_UNABLE_TO_MOVE_REPLACEMENT_2

Unable to move the replacement file to the file to be replaced. The file to be replaced has been renamed using the backup name.

ERROR_JOURNAL_DELETE_IN_PROGRESS

The volume change journal is being deleted.

ERROR_JOURNAL_NOT_ACTIVE

The volume change journal service is not active.

ERROR_JOURNAL_ENTRY_DELETED

The journal entry has been deleted from the journal.

ERROR_BAD_DEVICE

The specified device name is invalid.

ERROR_CONNECTION_UNAVAIL

The device is not currently connected but it is a remembered connection.

ERROR_DEVICE_ALREADY_REMEMBERED

An attempt was made to remember a device that had previously been remembered.

ERROR_NO_NET_OR_BAD_PATH

No network provider accepted the given network path.

ERROR_BAD_PROVIDER

The specified network provider name is invalid.

ERROR_CANNOT_OPEN_PROFILE

Unable to open the network connection profile.

ERROR_BAD_PROFILE

The network connection profile is corrupted.

ABB Automation

1MRS751251-MEN

ABB Automation

1222

1223

1224

1215

1216

1217

1218

1219

1221

1211

1212

1213

1214

1207

1208

1209

1210

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_NOT_CONTAINER

Cannot enumerate a noncontainer.

ERROR_EXTENDED_ERROR

An extended error has occurred.

ERROR_INVALID_GROUPNAME

The format of the specified group name is invalid.

ERROR_INVALID_COMPUTERNAME

The format of the specified computer name is invalid.

ERROR_INVALID_EVENTNAME

The format of the specified event name is invalid.

ERROR_INVALID_DOMAINNAME

The format of the specified domain name is invalid.

ERROR_INVALID_SERVICENAME

The format of the specified service name is invalid.

ERROR_INVALID_NETNAME

The format of the specified network name is invalid.

ERROR_INVALID_SHARENAME

The format of the specified share name is invalid.

ERROR_INVALID_PASSWORDNAME

The format of the specified password is invalid.

ERROR_INVALID_MESSAGENAME

The format of the specified message name is invalid.

ERROR_INVALID_MESSAGEDEST

The format of the specified message destination is invalid.

ERROR_SESSION_CREDENTIAL_CONFLICT

The credentials supplied conflict with an existing set of credentials.

ERROR_DUP_DOMAINNAME

The workgroup or domain name is already in use by another computer on the network.

ERROR_NO_NETWORK

The network is not present or not started.

ERROR_CANCELLED

The operation was canceled by the user.

ERROR_USER_MAPPED_FILE

The requested operation cannot be performed on a file with a usermapped section open.

135

MicroSCADA

3 Status Codes

136

1235

1236

1237

1238

1239

1240

1241

1229

1230

1231

1232

1225

1226

1227

1228

1233

1234

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_CONNECTION_REFUSED

The remote system refused the network connection.

ERROR_GRACEFUL_DISCONNECT

The network connection was gracefully closed.

ERROR_ADDRESS_ALREADY_ASSOCIATED

The network transport endpoint already has an address associated with it.

ERROR_ADDRESS_NOT_ASSOCIATED

An address has not yet been associated with the network endpoint.

ERROR_CONNECTION_INVALID

An operation was attempted on a nonexistent network connection.

ERROR_CONNECTION_ACTIVE

An invalid operation was attempted on an active network connection.

ERROR_NETWORK_UNREACHABLE

The remote network is not reachable by the transport.

ERROR_HOST_UNREACHABLE

The remote system is not reachable by the transport.

ERROR_PROTOCOL_UNREACHABLE

The remote system does not support the transport protocol.

ERROR_PORT_UNREACHABLE

No service is operating at the destination network endpoint on the remote system.

ERROR_REQUEST_ABORTED

The request was aborted.

ERROR_CONNECTION_ABORTED

The network connection was aborted by the local system.

ERROR_RETRY

The operation could not be completed. A retry should be performed.

ERROR_CONNECTION_COUNT_LIMIT

A connection to the server could not be made because the limit on the number of concurrent connections for this account has been reached.

ERROR_LOGIN_TIME_RESTRICTION

Attempting to log in during an unauthorized time of day for this account.

ERROR_LOGIN_WKSTA_RESTRICTION

The account is not authorized to log in from this station.

ERROR_INCORRECT_ADDRESS

The network address could not be used for the operation requested.

ABB Automation

1MRS751251-MEN

ABB Automation

1242

1243

1244

1245

1246

1247

1251

1300

1301

1302

1303

1248

1249

1250

1304

1305

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_ALREADY_REGISTERED

The service is already registered.

ERROR_SERVICE_NOT_FOUND

The specified service does not exist.

ERROR_NOT_AUTHENTICATED

The operation being requested was not performed because the user has not been authenticated.

ERROR_NOT_LOGGED_ON

The operation being requested was not performed because the user has not logged on to the network. The specified service does not exist.

ERROR_CONTINUE

Continue with work in progress.

ERROR_ALREADY_INITIALIZED

An attempt was made to perform an initialization operation when initialization has already been completed.

ERROR_NO_MORE_DEVICES

No more local devices.

ERROR_NO_SUCH_SITE

The specified site does not exist.

ERROR_DOMAIN_CONTROLLER_EXISTS

A domain controller with the specified name already exists.

ERROR_ONLY_IF_CONNECTED

This operation is supported only when you are connected to the server.

ERROR_NOT_ALL_ASSIGNED

Not all privileges referenced are assigned to the caller.

ERROR_SOME_NOT_MAPPED

Some mapping between account names and security IDs was not done.

ERROR_NO_QUOTAS_FOR_ACCOUNT

No system quota limits are specifically set for this account.

ERROR_LOCAL_USER_SESSION_KEY

No encryption key is available. A well-known encryption key was returned.

ERROR_NULL_LM_PASSWORD

The Windows NT password is too complex to be converted to a LAN

Manager password. The LAN Manager password returned is a NULL string.

ERROR_UNKNOWN_REVISION

The revision level is unknown.

137

MicroSCADA

3 Status Codes

138

1306

1307

1308

1309

1310

1311

1312

1317

1318

1319

1321

1313

1314

1315

1316

1322

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_REVISION_MISMATCH

Indicates two revision levels are incompatible.

ERROR_INVALID_OWNER

This security ID may not be assigned as the owner of this object.

ERROR_INVALID_PRIMARY_GROUP

This security ID may not be assigned as the primary group of an object.

ERROR_NO_IMPERSONATION_TOKEN

An attempt has been made to operate on an impersonation token by a thread that is not currently impersonating a client.

ERROR_CANT_DISABLE_MANDATORY

The group may not be disabled.

ERROR_NO_LOGON_SERVERS

There are currently no logon servers available to service the logon request.

ERROR_NO_SUCH_LOGON_SESSION

A specified logon session does not exist. It may already have been terminated.

ERROR_NO_SUCH_PRIVILEGE

A specified privilege does not exist.

ERROR_PRIVILEGE_NOT_HELD

A required privilege is not held by the client.

ERROR_INVALID_ACCOUNT_NAME

The name provided is not a properly formed account name.

ERROR_USER_EXISTS

The specified user already exists.

ERROR_NO_SUCH_USER

The specified user does not exist.

ERROR_GROUP_EXISTS

The specified group already exists.

ERROR_NO_SUCH_GROUP

The specified group does not exist.

ERROR_MEMBER_NOT_IN_GROUP

The specified user account is not a member of the specified group account.

ERROR_LAST_ADMIN

The last remaining administration account cannot be disabled or deleted.

ABB Automation

1MRS751251-MEN

1323

1324

1325

1330

1331

1332

1333

1326

1327

1328

1329

1334

1335

1336

1337

1338

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_WRONG_PASSWORD

Unable to update the password. The value provided as the current password is incorrect.

ERROR_ILL_FORMED_PASSWORD

Unable to update the password. The value provided for the new password contains values that are not allowed in passwords.

ERROR_PASSWORD_RESTRICTION

Unable to update the password because a password update rule has been violated.

ERROR_LOGON_FAILURE

Logon failure: unknown user name or bad password.

ERROR_ACCOUNT_RESTRICTION

Logon failure: user account restriction.

ERROR_INVALID_LOGON_HOURS

Logon failure: account logon time restriction violation.

ERROR_INVALID_WORKSTATION

Logon failure: user not allowed to log on to this computer.

ERROR_PASSWORD_EXPIRED

Logon failure: the specified account password has expired.

ERROR_ACCOUNT_DISABLED

Logon failure: account currently disabled.

ERROR_NONE_MAPPED

No mapping between account names and security IDs was done.

ERROR_TOO_MANY_LUIDS_REQUESTED

Too many local user identifiers (LUIDs) were requested at one time.

ERROR_LUIDS_EXHAUSTED

No more local user identifiers (LUIDs) are available.

ERROR_INVALID_SUB_AUTHORITY

The subauthority part of a security ID is invalid for this particular use.

ERROR_INVALID_ACL

The access control list (ACL) structure is invalid.

ERROR_INVALID_SID

The security ID structure is invalid.

ERROR_INVALID_SECURITY_DESCR

The security descriptor structure is invalid.

ABB Automation

139

MicroSCADA

3 Status Codes

140

1340

1347

1348

1349

1350

1341

1342

1343

1344

1352

1353

1354

1355

1356

1357

1358

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_BAD_INHERITANCE_ACL

The inherited access control list (ACL) or access control entry (ACE) could not be built.

ERROR_SERVER_DISABLED

The server is currently disabled.

ERROR_SERVER_NOT_DISABLED

The server is currently enabled.

ERROR_INVALID_ID_AUTHORITY

The value provided was an invalid value for an identifier authority.

ERROR_ALLOTTED_SPACE_EXCEEDED

No more memory is available for security information updates.

ERROR_CANT_OPEN_ANONYMOUS

Cannot open an anonymous level security token.

ERROR_BAD_VALIDATION_CLASS

The validation information class requested was invalid.

ERROR_BAD_TOKEN_TYPE

The type of the token is inappropriate for its attempted use.

ERROR_NO_SECURITY_ON_OBJECT

Unable to perform a security operation on an object that has no associated security.

ERROR_INVALID_SERVER_STATE

The security account manager (SAM) or local security authority (LSA) server was in the wrong state to perform the security operation.

ERROR_INVALID_DOMAIN_STATE

The domain was in the wrong state to perform the security operation.

ERROR_INVALID_DOMAIN_ROLE

This operation is only allowed for the Primary Domain Controller of the domain.

ERROR_NO_SUCH_DOMAIN

The specified domain did not exist.

ERROR_DOMAIN_EXISTS

The specified domain already exists.

ERROR_DOMAIN_LIMIT_EXCEEDED

An attempt was made to exceed the limit on the number of domains per server.

ERROR_INTERNAL_DB_CORRUPTION

Unable to complete the requested operation because of either a catastrophic media failure or a data structure corruption on the disk.

ABB Automation

1MRS751251-MEN

ABB Automation

1359

1360

1361

1362

1363

1364

1365

1366

1367

1368

1369

1370

1371

1372

1373

1374

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_INTERNAL_ERROR

The security account database contains an internal inconsistency.

ERROR_GENERIC_NOT_MAPPED

Generic access types were contained in an access mask which should already be mapped to nongeneric types.

ERROR_BAD_DESCRIPTOR_FORMAT

A security descriptor is not in the right format (absolute or self-relative).

ERROR_NOT_LOGON_PROCESS

The requested action is restricted for use by logon processes only. The calling process has not registered as a logon process.

ERROR_LOGON_SESSION_EXISTS

Cannot start a new logon session with an ID that is already in use.

ERROR_NO_SUCH_PACKAGE

A specified authentication package is unknown.

ERROR_BAD_LOGON_SESSION_STATE

The logon session is not in a state that is consistent with the requested operation.

ERROR_LOGON_SESSION_COLLISION

The logon session ID is already in use.

ERROR_INVALID_LOGON_TYPE

A logon request contained an invalid logon type value.

ERROR_CANNOT_IMPERSONATE

Unable to impersonate using a named pipe until data has been read from that pipe.

ERROR_RXACT_INVALID_STATE

The transaction state of a registry subtree is incompatible with the requested operation.

ERROR_RXACT_COMMIT_FAILURE

An internal security database corruption has been encountered.

ERROR_SPECIAL_ACCOUNT

Cannot perform this operation on built-in accounts.

ERROR_SPECIAL_GROUP

Cannot perform this operation on this built-in special group.

ERROR_SPECIAL_USER

Cannot perform this operation on this built-in special user.

ERROR_MEMBERS_PRIMARY_GROUP

The user cannot be removed from a group because the group is currently the user’s primary group.

141

MicroSCADA

3 Status Codes

142

1375

1376

1377

1378

1379

1380

1381

1382

1383

1385

1386

1387

1388

1389

1390

1391

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_TOKEN_ALREADY_IN_USE

The token is already in use as a primary token.

ERROR_NO_SUCH_ALIAS

The specified local group does not exist.

ERROR_MEMBER_NOT_IN_ALIAS

The specified account name is not a member of the local group.

ERROR_MEMBER_IN_ALIAS

The specified account name is already a member of the local group.

ERROR_ALIAS_EXISTS

The specified local group already exists.

ERROR_LOGON_NOT_GRANTED

Logon failure: the user has not been granted the requested logon type at this computer.

ERROR_TOO_MANY_SECRETS

The maximum number of secrets that may be stored in a single system has been exceeded.

ERROR_SECRET_TOO_LONG

The length of a secret exceeds the maximum length allowed.

ERROR_INTERNAL_DB_ERROR

The local security authority database contains an internal inconsistency.

ERROR_LOGON_TYPE_NOT_GRANTED

Logon failure: the user has not been granted the requested logon type at this computer.

ERROR_NT_CROSS_ENCRYPTION_REQUIRED

A cross-encrypted password is necessary to change a user password.

ERROR_NO_SUCH_MEMBER

A new member could not be added to a local group because the member does not exist.

ERROR_INVALID_MEMBER

A new member could not be added to a local group because the member has the wrong account type.

ERROR_TOO_MANY_SIDS

Too many security IDs have been specified.

ERROR_LM_CROSS_ENCRYPTION_REQUIRED

A cross-encrypted password is necessary to change this user password.

ERROR_NO_INHERITANCE

Indicates an ACL contains no inheritable components.

ABB Automation

1MRS751251-MEN

ABB Automation

1392

1393

1394

1395

1396

1397

1402

1403

1404

1405

1398

1400

1401

1406

1407

1408

1409

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_FILE_CORRUPT

The file or directory is corrupted and unreadable.

ERROR_DISK_CORRUPT

The disk structure is corrupted and unreadable.

ERROR_NO_USER_SESSION_KEY

There is no user session key for the specified logon session.

ERROR_LICENSE_QUOTA_EXCEEDED

The service being accessed is licensed for a particular number of connections. No more connections can be made to the service at this time because there are already as many connections as the service

ERROR_WRONG_TARGET_NAME

Logon Failure: The target account name is incorrect.

ERROR_MUTUAL_AUTH_FAILED

Mutual Authentication failed. The server’s password is out of date at the domain controller.

ERROR_TIME_SKEW

There is a time difference between the client and server.

ERROR_INVALID_WINDOW_HANDLE

Invalid window handle.

ERROR_INVALID_MENU_HANDLE

Invalid menu handle.

ERROR_INVALID_CURSOR_HANDLE

Invalid cursor handle.

ERROR_INVALID_ACCEL_HANDLE

Invalid accelerator table handle.

ERROR_INVALID_HOOK_HANDLE

Invalid hook handle.

ERROR_INVALID_DWP_HANDLE

Invalid handle to a multiple-window position structure.

ERROR_TLW_WITH_WSCHILD

Cannot create a top-level child window.

ERROR_CANNOT_FIND_WND_CLASS

Cannot find window class.

ERROR_WINDOW_OF_OTHER_THREAD

Invalid window; it belongs to other thread.

ERROR_HOTKEY_ALREADY_REGISTERED

Hot key is already registered.

143

MicroSCADA

3 Status Codes

144

1422

1423

1424

1425

1418

1419

1420

1421

1426

1427

1414

1415

1416

1417

1410

1411

1412

1413

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_CLASS_ALREADY_EXISTS

Class already exists.

ERROR_CLASS_DOES_NOT_EXIST

Class does not exist.

ERROR_CLASS_HAS_WINDOWS

Class still has open windows.

ERROR_INVALID_INDEX

Invalid index.

ERROR_INVALID_ICON_HANDLE

Invalid icon handle.

ERROR_PRIVATE_DIALOG_INDEX

Using private DIALOG window words.

ERROR_LISTBOX_ID_NOT_FOUND

The list box identifier was not found.

ERROR_NO_WILDCARD_CHARACTERS

No wildcards were found.

ERROR_CLIPBOARD_NOT_OPEN

Thread does not have a clipboard open.

ERROR_HOTKEY_NOT_REGISTERED

Hot key is not registered.

ERROR_WINDOW_NOT_DIALOG

The window is not a valid dialog window.

ERROR_CONTROL_ID_NOT_FOUND

Control ID not found.

ERROR_INVALID_COMBOBOX_MESSAGE

Invalid message for a combo box because it does not have an edit control.

ERROR_WINDOW_NOT_COMBOBOX

The window is not a combo box.

ERROR_INVALID_EDIT_HEIGHT

Height must be less than 256.

ERROR_DC_NOT_FOUND

Invalid device context (DC) handle.

ERROR_INVALID_HOOK_FILTER

Invalid hook procedure type.

ERROR_INVALID_FILTER_PROC

Invalid hook procedure.

ABB Automation

1MRS751251-MEN

ABB Automation

1442

1443

1444

1436

1437

1438

1439

1440

1441

1432

1433

1434

1435

1428

1429

1430

1431

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_HOOK_NEEDS_HMOD

Cannot set nonlocal hook without a module handle.

ERROR_GLOBAL_ONLY_HOOK

This hook procedure can only be set globally.

ERROR_JOURNAL_HOOK_SET

The journal hook procedure is already installed.

ERROR_HOOK_NOT_INSTALLED

The hook procedure is not installed.

ERROR_INVALID_LB_MESSAGE

Invalid message for single-selection list box.

ERROR_SETCOUNT_ON_BAD_LB

LB_SETCOUNT sent to non-lazy list box.

ERROR_LB_WITHOUT_TABSTOPS

This list box does not support tab stops.

ERROR_DESTROY_OBJECT_OF_OTHER_THREAD

Cannot destroy object created by another thread.

ERROR_CHILD_WINDOW_MENU

Child windows cannot have menus.

ERROR_NO_SYSTEM_MENU

The window does not have a system menu.

ERROR_INVALID_MSGBOX_STYLE

Invalid message box style.

ERROR_INVALID_SPI_VALUE

Invalid system-wide (SPI_*) parameter.

ERROR_SCREEN_ALREADY_LOCKED

Screen already locked.

ERROR_HWNDS_HAVE_DIFF_PARENT

All handles to windows in a multiple-window position structure must have the same parent.

ERROR_NOT_CHILD_WINDOW

The window is not a child window.

ERROR_INVALID_GW_COMMAND

Invalid GW_* command.

ERROR_INVALID_THREAD_ID

Invalid thread identifier.

145

MicroSCADA

3 Status Codes

146

1445

1458

1459

1460

1461

1454

1455

1456

1457

1450

1451

1452

1453

1446

1447

1448

1449

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_NON_MDICHILD_WINDOW

Cannot process a message from a window that is not a multiple document interface (MDI) window.

ERROR_POPUP_ALREADY_ACTIVE

Popup menu already active.

ERROR_NO_SCROLLBARS

The window does not have scroll bars.

ERROR_INVALID_SCROLLBAR_RANGE

Scroll bar range cannot be greater than 0x7FFF.

ERROR_INVALID_SHOWWIN_COMMAND

Cannot show or remove the window in the way specified.

ERROR_NO_SYSTEM_RESOURCES

Insufficient system resources exist to complete the requested service.

ERROR_NONPAGED_SYSTEM_RESOURCES

Insufficient system resources exist to complete the requested service.

ERROR_PAGED_SYSTEM_RESOURCES

Insufficient system resources exist to complete the requested service.

ERROR_WORKING_SET_QUOTA

Insufficient quota to complete the requested service.

ERROR_PAGEFILE_QUOTA

Insufficient quota to complete the requested service.

ERROR_COMMITMENT_LIMIT

The paging file is too small for this operation to complete.

ERROR_MENU_ITEM_NOT_FOUND

A menu item was not found.

ERROR_INVALID_KEYBOARD_HANDLE

Invalid keyboard layout handle.

ERROR_HOOK_TYPE_NOT_ALLOWED

Hook type not allowed.

ERROR_REQUIRES_INTERACTIVE_WINDOWSTATION

This operation requires an interactive window station.

ERROR_TIMEOUT

This operation returned because the timeout period expired.

ERROR_INVALID_MONITOR_HANDLE

Invalid monitor handle.

ABB Automation

1MRS751251-MEN

ABB Automation

1611

1612

1613

1614

1607

1608

1609

1610

1615

1616

1602

1603

1605

1606

1500

1502

1503

1601

Status Codes

Technical Reference Manual

ERROR_EVENTLOG_FILE_CORRUPT

The event log file is corrupted.

ERROR_LOG_FILE_FULL

The event log file is full.

ERROR_EVENTLOG_FILE_CHANGED

The event log file has changed between read operations.

ERROR_INSTALL_SERVICE_FAILURE

Failure accessing installation service.

ERROR_INSTALL_USEREXIT

User cancelled installation.

ERROR_INSTALL_FAILURE

Fatal error during installation.

ERROR_UNKNOWN_PRODUCT

Product is not installed.

ERROR_UNKNOWN_FEATURE

Feature ID not registered.

ERROR_UNKNOWN_COMPONENT

Component ID not registered.

ERROR_UNKNOWN_PROPERTY

Unknown property.

ERROR_INVALID_HANDLE_STATE

Handle is in an invalid state.

ERROR_BAD_CONFIGURATION

Configuration data corrupt.

ERROR_INDEX_ABSENT

Component qualifier not present.

ERROR_INSTALL_SOURCE_ABSENT

Install source unavailable.

ERROR_INSTALL_PACKAGE_VERSION

Database version unsupported.

ERROR_PRODUCT_UNINSTALLED

Product is uninstalled.

ERROR_BAD_QUERY_SYNTAX

SQL query syntax invalid or unsupported.

ERROR_INVALID_FIELD

Record field does not exist.

MicroSCADA

3 Status Codes

147

MicroSCADA

3 Status Codes

148

1629

1630

1631

1632

1625

1626

1627

1628

1633

1634

1621

1622

1623

1624

1617

1618

1619

1620

Status Codes

Technical Reference Manual

ERROR_DEVICE_REMOVED

The device has been removed.

ERROR_INSTALL_ALREADY_RUNNING

An installation is in progress.

ERROR_INSTALL_PACKAGE_OPEN_FAILED

Installation package could not be opened.

ERROR_INSTALL_PACKAGE_INVALID

Installation package invalid.

ERROR_INSTALL_UI_FAILURE

Could not initialize installer user interface.

ERROR_INSTALL_LOG_FAILURE

Error opening installation log file.

ERROR_INSTALL_LANGUAGE_UNSUPPORTED

Product language not supported by system.

ERROR_INSTALL_TRANSFORM_FAILURE

Error applying transform to install package.

ERROR_INSTALL_PACKAGE_REJECTED

Install package signature not accepted.

ERROR_FUNCTION_NOT_CALLED

Function could not be executed.

ERROR_FUNCTION_FAILED

Function failed during execution.

ERROR_INVALID_TABLE

Invalid or unknown table specified.

ERROR_DATATYPE_MISMATCH

Data supplied is of wrong type.

ERROR_UNSUPPORTED_TYPE

Data of this type is not supported.

ERROR_CREATE_FAILED

Unable to create requested object.

ERROR_INSTALL_TEMP_UNWRITABLE

Temp folder is full or inaccessible.

ERROR_INSTALL_PLATFORM_UNSUPPORTED

Product platform not supported.

ERROR_INSTALL_NOTUSED

Component not used on this computer.

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

ABB Automation

1708

1709

1710

1711

1704

1705

1706

1707

1700

1701

1702

1703

1635

1636

1637

1638

1712

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_PATCH_PACKAGE_OPEN_FAILED

Patch package could not be opened.

ERROR_PATCH_PACKAGE_INVALID

Patch package invalid.

ERROR_PATCH_PACKAGE_UNSUPPORTED.

Patch package unsupported.

ERROR_INVALID_COMMAND_LINE

Invalid command line argument.

RPC_S_INVALID_STRING_BINDING

The string binding is invalid.

RPC_S_WRONG_KIND_OF_BINDING

The binding handle is not the correct type.

RPC_S_INVALID_BINDING

The binding handle is invalid.

RPC_S_PROTSEQ_NOT_SUPPORTED

The RPC protocol sequence is not supported.

RPC_S_INVALID_RPC_PROTSEQ

The RPC protocol sequence is invalid.

RPC_S_INVALID_STRING_UUID

The string universal unique identifier (UUID) is invalid.

RPC_S_INVALID_ENDPOINT_FORMAT

The endpoint format is invalid.

RPC_S_INVALID_NET_ADDR

The network address is invalid.

RPC_S_NO_ENDPOINT_FOUND

No endpoint was found.

RPC_S_INVALID_TIMEOUT

The timeout value is invalid.

RPC_S_OBJECT_NOT_FOUND

The object universal unique identifier (UUID) was not found.

RPC_S_ALREADY_REGISTERED

The object universal unique identifier (UUID) has already been registered.

RPC_S_TYPE_ALREADY_REGISTERED

The type universal unique identifier (UUID) has already been registered.

149

MicroSCADA

3 Status Codes

150

1725

1726

1727

1728

1721

1722

1723

1724

1730

1732

1717

1718

1719

1720

1713

1714

1715

1716

Status Codes

Technical Reference Manual

1MRS751251-MEN

RPC_S_ALREADY_LISTENING

The RPC server is already listening.

RPC_S_NO_PROTSEQS_REGISTERED

No protocol sequences have been registered.

RPC_S_NOT_LISTENING

The RPC server is not listening.

RPC_S_UNKNOWN_MGR_TYPE

The manager type is unknown.

RPC_S_UNKNOWN_IF

The interface is unknown.

RPC_S_NO_BINDINGS

There are no bindings.

RPC_S_NO_PROTSEQS

There are no protocol sequences.

RPC_S_CANT_CREATE_ENDPOINT

The endpoint cannot be created.

RPC_S_OUT_OF_RESOURCES

Not enough resources are available to complete this operation.

RPC_S_SERVER_UNAVAILABLE

The RPC server is unavailable.

RPC_S_SERVER_TOO_BUSY

The RPC server is too busy to complete this operation.

RPC_S_INVALID_NETWORK_OPTIONS

The network options are invalid.

RPC_S_NO_CALL_ACTIVE

There are no remote procedure calls active on this thread.

RPC_S_CALL_FAILED

The remote procedure call failed.

RPC_S_CALL_FAILED_DNE

The remote procedure call failed and did not execute.

RPC_S_PROTOCOL_ERROR

A remote procedure call (RPC) protocol error occurred.

RPC_S_UNSUPPORTED_TRANS_SYN

The transfer syntax is not supported by the RPC server.

RPC_S_UNSUPPORTED_TYPE

The universal unique identifier (UUID) type is not supported.

ABB Automation

1MRS751251-MEN

ABB Automation

1733

1734

1735

1736

1737

1739

1743

1744

1745

1746

1740

1741

1742

1747

1748

1749

1750

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

RPC_S_INVALID_TAG

The tag is invalid.

RPC_S_INVALID_BOUND

The array bounds are invalid.

RPC_S_NO_ENTRY_NAME

The binding does not contain an entry name.

RPC_S_INVALID_NAME_SYNTAX

The name syntax is invalid.

RPC_S_UNSUPPORTED_NAME_SYNTAX

The name syntax is not supported.

RPC_S_UUID_NO_ADDRESS

No network address is available to use to construct a universal unique identifier (UUID).

RPC_S_DUPLICATE_ENDPOINT

The endpoint is a duplicate.

RPC_S_UNKNOWN_AUTHN_TYPE

The authentication type is unknown.

RPC_S_MAX_CALLS_TOO_SMALL

The maximum number of calls is too small.

RPC_S_STRING_TOO_LONG

The string is too long.

RPC_S_PROTSEQ_NOT_FOUND

The RPC protocol sequence was not found.

RPC_S_PROCNUM_OUT_OF_RANGE

The procedure number is out of range.

RPC_S_BINDING_HAS_NO_AUTH

The binding does not contain any authentication information.

RPC_S_UNKNOWN_AUTHN_SERVICE

The authentication service is unknown.

RPC_S_UNKNOWN_AUTHN_LEVEL

The authentication level is unknown.

RPC_S_INVALID_AUTH_IDENTITY

The security context is invalid.

RPC_S_UNKNOWN_AUTHZ_SERVICE

The authorization service is unknown.

151

MicroSCADA

3 Status Codes

152

1763

1764

1765

1766

1759

1760

1761

1762

1767

1768

1755

1756

1757

1758

1751

1752

1753

1754

Status Codes

Technical Reference Manual

1MRS751251-MEN

EPT_S_INVALID_ENTRY

The entry is invalid.

EPT_S_CANT_PERFORM_OP

The server endpoint cannot perform the operation.

EPT_S_NOT_REGISTERED

There are no more endpoints available from the endpoint mapper.

RPC_S_NOTHING_TO_EXPORT

No interfaces have been exported.

RPC_S_INCOMPLETE_NAME

The entry name is incomplete.

RPC_S_INVALID_VERS_OPTION

The version option is invalid.

RPC_S_NO_MORE_MEMBERS

There are no more members.

RPC_S_NOT_ALL_OBJS_UNEXPORTED

There is nothing to unexport.

RPC_S_INTERFACE_NOT_FOUND

The interface was not found.

RPC_S_ENTRY_ALREADY_EXISTS

The entry already exists.

RPC_S_ENTRY_NOT_FOUND

The entry is not found.

RPC_S_NAME_SERVICE_UNAVAILABLE

The name service is unavailable.

RPC_S_INVALID_NAF_ID

The network address family is invalid.

RPC_S_CANNOT_SUPPORT

The requested operation is not supported.

RPC_S_NO_CONTEXT_AVAILABLE

No security context is available to allow impersonation.

RPC_S_INTERNAL_ERROR

An internal error occurred in a remote procedure call (RPC).

RPC_S_ZERO_DIVIDE

The RPC server attempted an integer division by zero.

RPC_S_ADDRESS_ERROR

An addressing error occurred in the RPC server.

ABB Automation

1MRS751251-MEN

ABB Automation

1769

1770

1771

1772

1773

1774

1775

1781

1782

1783

1784

1777

1778

1779

1780

1785

1786

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

RPC_S_FP_DIV_ZERO

A floating-point operation at the RPC server caused a division by zero.

RPC_S_FP_UNDERFLOW

A floating-point underflow occurred at the RPC server.

RPC_S_FP_OVERFLOW

A floating-point overflow occurred at the RPC server.

RPC_X_NO_MORE_ENTRIES

The list of RPC servers available for the binding of auto handles has been exhausted.

RPC_X_SS_CHAR_TRANS_OPEN_FAIL

Unable to open the character translation table file.

RPC_X_SS_CHAR_TRANS_SHORT_FILE

The file containing the character translation table has fewer than 512 bytes.

RPC_X_SS_IN_NULL_CONTEXT

A null context handle was passed from the client to the host during a remote procedure call.

RPC_X_SS_CONTEXT_DAMAGED

The context handle changed during a remote procedure call.

RPC_X_SS_HANDLES_MISMATCH

The binding handles passed to a remote procedure call do not match.

RPC_X_SS_CANNOT_GET_CALL_HANDLE

The stub is unable to get the remote procedure call handle.

RPC_X_NULL_REF_POINTER

A null reference pointer was passed to the stub.

RPC_X_ENUM_VALUE_OUT_OF_RANGE

The enumeration value is out of range.

RPC_X_BYTE_COUNT_TOO_SMALL

The byte count is too small.

RPC_X_BAD_STUB_DATA

The stub received bad data.

ERROR_INVALID_USER_BUFFER

The supplied user buffer is not valid for the requested operation.

ERROR_UNRECOGNIZED_MEDIA

The disk media is not recognized. It may not be formatted.

ERROR_NO_TRUST_LSA_SECRET

The workstation does not have a trust secret.

153

MicroSCADA

3 Status Codes

154

1787

1788

1789

1799

1800

1801

1802

1803

1804

1795

1796

1797

1798

1790

1791

1793

1794

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_NO_TRUST_SAM_ACCOUNT

The SAM database on the Windows NT Server does not have a computer account for this workstation trust relationship.

ERROR_TRUSTED_DOMAIN_FAILURE

The trust relationship between the primary domain and the trusted domain failed.

ERROR_TRUSTED_RELATIONSHIP_FAILURE

The trust relationship between this workstation and the primary domain failed.

ERROR_TRUST_FAILURE

The network logon failed.

RPC_S_CALL_IN_PROGRESS

A remote procedure call is already in progress for this thread.

ERROR_ACCOUNT_EXPIRED

The user’s account has expired.

ERROR_REDIRECTOR_HAS_OPEN_HANDLES

The redirector is in use and cannot be unloaded.

ERROR_PRINTER_DRIVER_ALREADY_INSTALLED

The specified printer driver is already installed.

ERROR_UNKNOWN_PORT

The specified port is unknown.

ERROR_UNKNOWN_PRINTER_DRIVER

The printer driver is unknown.

ERROR_UNKNOWN_PRINTPROCESSOR

The print processor is unknown.

ERROR_INVALID_SEPARATOR_FILE

The specified separator file is invalid.

ERROR_INVALID_PRIORITY

The specified priority is invalid.

ERROR_INVALID_PRINTER_NAME

The printer name is invalid.

ERROR_PRINTER_ALREADY_EXISTS

The printer already exists.

ERROR_INVALID_PRINTER_COMMAND

The printer command is invalid.

ERROR_INVALID_DATATYPE

The specified datatype is invalid.

ABB Automation

1MRS751251-MEN

ABB Automation

1805

1806

1807

1808

1809

1810

1815

1816

1817

1818

1811

1812

1813

1814

1819

1820

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_INVALID_ENVIRONMENT

The environment specified is invalid.

RPC_S_NO_MORE_BINDINGS

There are no more bindings.

ERROR_NOLOGON_INTERDOMAIN_TRUST_ACCOUNT

The account used is an interdomain trust account. Use your global user account or local user account to access this server.

ERROR_NOLOGON_WORKSTATION_TRUST_ACCOUNT

The account used is a computer account. Use your global user account or local user account to access this server.

ERROR_NOLOGON_SERVER_TRUST_ACCOUNT

The account used is a server trust account. Use your global user account or local user account to access this server.

ERROR_DOMAIN_TRUST_INCONSISTENT

The name or security ID (SID) of the domain specified is inconsistent with the trust information for that domain.

ERROR_SERVER_HAS_OPEN_HANDLES

The server is in use and cannot be unloaded.

ERROR_RESOURCE_DATA_NOT_FOUND

The specified image file did not contain a resource section.

ERROR_RESOURCE_TYPE_NOT_FOUND

The specified resource type cannot be found in the image file.

ERROR_RESOURCE_NAME_NOT_FOUND

The specified resource name cannot be found in the image file.

ERROR_RESOURCE_LANG_NOT_FOUND

The specified resource language ID cannot be found in the image file.

ERROR_NOT_ENOUGH_QUOTA

Not enough quota is available to process this command.

RPC_S_NO_INTERFACES

No interfaces have been registered.

RPC_S_CALL_CANCELLED

The remote procedure call was cancelled.

RPC_S_BINDING_INCOMPLETE

The binding handle does not contain all required information.

RPC_S_COMM_FAILURE

A communications failure occurred during a remote procedure call.

155

MicroSCADA

3 Status Codes

156

1898

1899

1900

1901

1829

1830

1831

1832

1902

1903

1825

1826

1827

1828

1821

1822

1823

1824

Status Codes

Technical Reference Manual

1MRS751251-MEN

RPC_S_UNSUPPORTED_AUTHN_LEVEL

The requested authentication level is not supported.

RPC_S_NO_PRINC_NAME

No principal name registered.

RPC_S_NOT_RPC_ERROR

The error specified is not a valid Windows RPC error code.

RPC_S_UUID_LOCAL_ONLY

A UUID that is valid only on this computer has been allocated.

RPC_S_SEC_PKG_ERROR

A security package specific error occurred.

RPC_S_NOT_CANCELLED

Thread is not canceled.

RPC_X_INVALID_ES_ACTION

Invalid operation on the encoding/decoding handle.

RPC_X_WRONG_ES_VERSION

Incompatible version of the serializing package.

RPC_X_WRONG_STUB_VERSION

Incompatible version of the RPC stub.

RPC_X_INVALID_PIPE_OBJECT

The RPC pipe object is invalid or corrupted.

RPC_X_WRONG_PIPE_ORDER

An invalid operation was attempted on an RPC pipe object.

RPC_X_WRONG_PIPE_VERSION

Unsupported RPC pipe version.

RPC_S_GROUP_MEMBER_NOT_FOUND

The group member was not found.

EPT_S_CANT_CREATE

The endpoint mapper database entry could not be created.

RPC_S_INVALID_OBJECT

The object universal unique identifier (UUID) is the nil UUID.

ERROR_INVALID_TIME

The specified time is invalid.

ERROR_INVALID_FORM_NAME

The specified form name is invalid.

ERROR_INVALID_FORM_SIZE

The specified form size is invalid.

ABB Automation

1MRS751251-MEN

ABB Automation

1904

1905

1906

1907

1908

1909

1913

1914

1915

1916

1910

1911

1912

1917

1918

1919

1920

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_ALREADY_WAITING

The specified printer handle is already being waited on

ERROR_PRINTER_DELETED

The specified printer has been deleted.

ERROR_INVALID_PRINTER_STATE

The state of the printer is invalid.

ERROR_PASSWORD_MUST_CHANGE

The user must change his password before he logs on the first time.

ERROR_DOMAIN_CONTROLLER_NOT_FOUND

Could not find the domain controller for this domain.

ERROR_ACCOUNT_LOCKED_OUT

The referenced account is currently locked out and may not be logged on to.

OR_INVALID_OXID

The object exporter specified was not found.

OR_INVALID_OID

The object specified was not found.

OR_INVALID_SET

The object resolver set specified was not found.

RPC_S_SEND_INCOMPLETE

Some data remains to be sent in the request buffer.

RPC_S_INVALID_ASYNC_HANDLE

Invalid asynchronous remote procedure call handle.

RPC_S_INVALID_ASYNC_CALL

Invalid asynchronous RPC call handle for this operation.

RPC_X_PIPE_CLOSED

The RPC pipe object has already been closed.

RPC_X_PIPE_DISCIPLINE_ERROR

The RPC call completed before all pipes were processed.

RPC_X_PIPE_EMPTY

No more data is available from the RPC pipe.

ERROR_NO_SITENAME

No site name is available for this machine.

ERROR_CANT_ACCESS_FILE

The file can not be accessed by the system.

157

MicroSCADA

3 Status Codes

158

2003

2004

2005

2010

1929

2000

2001

2002

2011

2012

1925

1926

1927

1928

1921

1922

1923

1924

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_CANT_RESOLVE_FILENAME

The name of the file cannot be resolved by the system.

RPC_S_ENTRY_TYPE_MISMATCH

The entry is not of the expected type.

RPC_S_NOT_ALL_OBJS_EXPORTED

Not all object UUIDs could be exported to the specified entry.

RPC_S_INTERFACE_NOT_EXPORTED

Interface could not be exported to the specified entry.

RPC_S_PROFILE_NOT_ADDED

The specified profile entry could not be added.

RPC_S_PRF_ELT_NOT_ADDED

The specified profile element could not be added.

RPC_S_PRF_ELT_NOT_REMOVED

The specified profile element could not be removed.

RPC_S_GRP_ELT_NOT_ADDED

The group element could not be added.

RPC_S_GRP_ELT_NOT_REMOVED

The group element could not be removed.

ERROR_INVALID_PIXEL_FORMAT

The pixel format is invalid.

ERROR_BAD_DRIVER

The specified driver is invalid.

ERROR_INVALID_WINDOW_STYLE

The window style or class attribute is invalid for this operation.

ERROR_METAFILE_NOT_SUPPORTED

The requested metafile operation is not supported.

ERROR_TRANSFORM_NOT_SUPPORTED

The requested transformation operation is not supported.

ERROR_CLIPPING_NOT_SUPPORTED

The requested clipping operation is not supported.

ERROR_INVALID_CMM

The specified color management module is invalid.

ERROR_INVALID_PROFILE

The specified color profile is invalid.

ERROR_TAG_NOT_FOUND

The specified tag was not found.

ABB Automation

1MRS751251-MEN

ABB Automation

2401

2402

2404

3000

2021

2022

2202

2250

3001

3002

2017

2018

2019

2020

2013

2014

2015

2016

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_TAG_NOT_PRESENT

A required tag is not present.

ERROR_DUPLICATE_TAG

The specified tag is already present.

ERROR_PROFILE_NOT_ASSOCIATED_WITH_DEVICE

The specified color profile is not associated with any device.

ERROR_PROFILE_NOT_FOUND

The specified color profile was not found.

ERROR_INVALID_COLORSPACE

The specified color space is invalid.

ERROR_ICM_NOT_ENABLED

Image Color Management is not enabled.

ERROR_DELETING_ICM_XFORM

There was an error while deleting the color transform.

ERROR_INVALID_TRANSFORM

The specified color transform is invalid.

ERROR_COLORSPACE_MISMATCH

The specified transform does not match the bitmap’s color space.

ERROR_INVALID_COLORINDEX

The specified named color index is not present in the profile.

ERROR_BAD_USERNAME

The specified username is invalid.

ERROR_NOT_CONNECTED

This network connection does not exist.

ERROR_OPEN_FILES

This network connection has files open or requests pending.

ERROR_ACTIVE_CONNECTIONS

Active connections still exist.

ERROR_DEVICE_IN_USE

The device is in use by an active process and cannot be disconnected.

ERROR_UNKNOWN_PRINT_MONITOR

The specified print monitor is unknown.

ERROR_PRINTER_DRIVER_IN_USE

The specified printer driver is currently in use.

ERROR_SPOOL_FILE_NOT_FOUND

The spool file was not found.

159

MicroSCADA

3 Status Codes

160

3007

3008

3009

3003

3004

3005

3006

3010

3011

3012

4000

4001

4002

4003

4004

4005

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_SPL_NO_STARTDOC

A StartDocPrinter call was not issued.

ERROR_SPL_NO_ADDJOB

An AddJob call was not issued.

ERROR_PRINT_PROCESSOR_ALREADY_INSTALLED

The specified print processor has already been installed.

ERROR_PRINT_MONITOR_ALREADY_INSTALLED

The specified print monitor has already been installed.

ERROR_INVALID_PRINT_MONITOR

The specified print monitor does not have the required functions.

ERROR_PRINT_MONITOR_IN_USE

The specified print monitor is currently in use.

ERROR_PRINTER_HAS_JOBS_QUEUED

The requested operation is not allowed when there are jobs queued to the printer.

ERROR_SUCCESS_REBOOT_REQUIRED

The requested operation is successful. Changes will not be effective until the system is rebooted.

ERROR_SUCCESS_RESTART_REQUIRED

The requested operation is successful. Changes will not be effective until the service is restarted.

ERROR_PRINTER_NOT_FOUND

No printers were found.

ERROR_WINS_INTERNAL

WINS encountered an error while processing the command.

ERROR_CAN_NOT_DEL_LOCAL_WINS

The local WINS can not be deleted.

ERROR_STATIC_INIT

The importation from the file failed.

ERROR_INC_BACKUP

The backup failed. Was a full backup done before?

ERROR_FULL_BACKUP

The backup failed. Check the directory to which you are backing the database.

ERROR_REC_NON_EXISTENT

The name does not exist in the WINS database.

ABB Automation

1MRS751251-MEN

ABB Automation

4006

4100

4200

4201

4202

4203

4204

4205

4209

4210

4211

4212

4213

4206

4207

4208

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_RPL_NOT_ALLOWED

Replication with a nonconfigured partner is not allowed.

ERROR_DHCP_ADDRESS_CONFLICT

The DHCP client has obtained an IP address that is already in use on the network. The local interface will be disabled until the DHCP client can obtain a new address.

ERROR_WMI_GUID_NOT_FOUND

The GUID passed was not recognized as valid by a WMI data provider.

ERROR_WMI_INSTANCE_NOT_FOUND

The instance name passed was not recognized as valid by a WMI data provider.

ERROR_WMI_ITEMID_NOT_FOUND

The data item ID passed was not recognized as valid by a WMI data provider.

ERROR_WMI_TRY_AGAIN

The WMI request could not be completed and should be retried.

ERROR_WMI_DP_NOT_FOUND

The WMI data provider could not be located.

ERROR_WMI_UNRESOLVED_INSTANCE_REF

The WMI data provider references an instance set that has not been registered.

ERROR_WMI_ALREADY_ENABLED

The WMI data block or event notification has already been enabled.

ERROR_WMI_GUID_DISCONNECTED

The WMI data block is no longer available.

ERROR_WMI_SERVER_UNAVAILABLE

The WMI data service is not available.

ERROR_WMI_DP_FAILED

The WMI data provider failed to carry out the request.

ERROR_WMI_INVALID_MOF

The WMI MOF information is not valid.

ERROR_WMI_INVALID_REGINFO

The WMI registration information is not valid.

ERROR_WMI_ALREADY_DISABLED

The WMI data block or event notification has already been disabled.

ERROR_WMI_READ_ONLY

The WMI data item or data block is read only.

161

MicroSCADA

3 Status Codes

162

4214

4300

4301

4302

4303

4304

4310

4311

4312

4313

4305

4308

4309

4314

4315

4316

4317

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_WMI_SET_FAILURE

The WMI data item or data block could not be changed.

ERROR_INVALID_MEDIA

The media identifier does not represent a valid medium.

ERROR_INVALID_LIBRARY

The library identifier does not represent a valid library.

ERROR_INVALID_MEDIA_POOL

The media pool identifier does not represent a valid media pool.

ERROR_DRIVE_MEDIA_MISMATCH

The drive and medium are not compatible or exist in different libraries.

ERROR_MEDIA_OFFLINE

The medium currently exists in an offline library and must be online to perform this operation.

ERROR_LIBRARY_OFFLINE

The operation cannot be performed on an offline library.

ERROR_MEDIA_UNAVAILABLE

No media is currently available in this media pool or library.

ERROR_RESOURCE_DISABLED

A resource required for this operation is disabled.

ERROR_INVALID_CLEANER

The media identifier does not represent a valid cleaner.

ERROR_UNABLE_TO_CLEAN

The drive cannot be cleaned or does not support cleaning.

ERROR_OBJECT_NOT_FOUND

The object identifier does not represent a valid object.

ERROR_DATABASE_FAILURE

Unable to read from or write to the database.

ERROR_DATABASE_FULL

The database is full.

ERROR_MEDIA_INCOMPATIBLE

The medium is not compatible with the device or media pool.

ERROR_RESOURCE_NOT_PRESENT

The resource required for this operation does not exist.

ERROR_INVALID_OPERATION

The operation identifier is not valid.

ABB Automation

1MRS751251-MEN

ABB Automation

4330

4331

4332

4333

4326

4327

4328

4329

4322

4323

4324

4325

4318

4319

4320

4321

4334

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_MEDIA_NOT_AVAILABLE

The media is not mounted or ready for use.

ERROR_DEVICE_NOT_AVAILABLE

The device is not ready for use.

ERROR_REQUEST_REFUSED

The operator or administrator has refused the request.

ERROR_INVALID_DRIVE_OBJECT

The drive identifier does not represent a valid drive.

ERROR_LIBRARY_FULL

Library is full. No slot is available for use.

ERROR_MEDIUM_NOT_ACCESSIBLE

The transport cannot access the medium.

ERROR_UNABLE_TO_LOAD_MEDIUM

Unable to load the medium into the drive.

ERROR_UNABLE_TO_INVENTORY_DRIVE

Unable to retrieve status about the drive.

ERROR_UNABLE_TO_INVENTORY_SLOT

Unable to retrieve status about the slot.

ERROR_UNABLE_TO_INVENTORY_TRANSPORT

Unable to retrieve status about the transport.

ERROR_TRANSPORT_FULL

Cannot use the transport because it is already in use.

ERROR_CONTROLLING_IEPORT

Unable to open or close the inject/eject port.

ERROR_UNABLE_TO_EJECT_MOUNTED_MEDIA

Unable to eject the media because it is in a drive.

ERROR_CLEANER_SLOT_SET

A cleaner slot is already reserved.

ERROR_CLEANER_SLOT_NOT_SET

A cleaner slot is not reserved.

ERROR_CLEANER_CARTRIDGE_SPENT

The cleaner cartridge has performed the maximum number of drive cleanings.

ERROR_UNEXPECTED_OMID

Unexpected on-medium identifier.

163

MicroSCADA

3 Status Codes

4335

4336

4337

4338

4339

4350

4351

4352

4390

4391

4392

4393

4394

5001

5002

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_CANT_DELETE_LAST_ITEM

The last remaining item in this group or resource cannot be deleted.

ERROR_MESSAGE_EXCEEDS_MAX_SIZE

The message provided exceeds the maximum size allowed for this parameter.

ERROR_VOLUME_CONTAINS_SYS_FILES

The volume contains system or paging files.

ERROR_INDIGENOUS_TYPE

The media type cannot be removed from this library since at least one drive in the library reports it can support this media type.

ERROR_NO_SUPPORTING_DRIVES

This offline media cannot be mounted on this system since no enabled drives are present which can be used.

ERROR_FILE_OFFLINE

The remote storage service was not able to recall the file.

ERROR_REMOTE_STORAGE_NOT_ACTIVE

The remote storage service is not operational at this time.

ERROR_REMOTE_STORAGE_MEDIA_ERROR

The remote storage service encountered a media error.

ERROR_NOT_A_REPARSE_POINT

The file or directory is not a reparse point.

ERROR_REPARSE_ATTRIBUTE_CONFLICT

The reparse point attribute cannot be set because it conflicts with an existing attribute.

ERROR_INVALID_REPARSE_DATA

The data present in the reparse point buffer is invalid.

ERROR_REPARSE_TAG_INVALID

The tag present in the reparse point buffer is invalid.

ERROR_REPARSE_TAG_MISMATCH

There is a mismatch between the tag specified in the request and the tag present in the reparse point.

ERROR_DEPENDENT_RESOURCE_EXISTS

The cluster resource cannot be moved to another group because other resources are dependent on it.

ERROR_DEPENDENCY_NOT_FOUND

The cluster resource dependency cannot be found.

164

ABB Automation

1MRS751251-MEN

5003

5015

5016

5017

5008

5009

5010

5011

5004

5005

5006

5007

5012

5013

5014

5018

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DEPENDENCY_ALREADY_EXISTS

The cluster resource cannot be made dependent on the specified resource because it is already dependent.

ERROR_RESOURCE_NOT_ONLINE

The cluster resource is not online.

ERROR_HOST_NODE_NOT_AVAILABLE

A cluster node is not available for this operation.

ERROR_RESOURCE_NOT_AVAILABLE

The cluster resource is not available.

ERROR_RESOURCE_NOT_FOUND

The cluster resource could not be found.

ERROR_SHUTDOWN_CLUSTER

The cluster is being shut down.

ERROR_CANT_EVICT_ACTIVE_NODE

A cluster node cannot be evicted from the cluster while it is online.

ERROR_OBJECT_ALREADY_EXISTS

The object already exists.

ERROR_OBJECT_IN_LIST

The object is already in the list.

ERROR_GROUP_NOT_AVAILABLE

The cluster group is not available for any new requests.

ERROR_GROUP_NOT_FOUND

The cluster group could not be found.

ERROR_GROUP_NOT_ONLINE

The operation could not be completed because the cluster group is not online.

ERROR_HOST_NODE_NOT_RESOURCE_OWNER

The cluster node is not the owner of the resource.

ERROR_HOST_NODE_NOT_GROUP_OWNER

The cluster node is not the owner of the group.

ERROR_RESMON_CREATE_FAILED

The cluster resource could not be created in the specified resource monitor.

ERROR_RESMON_ONLINE_FAILED

The cluster resource could not be brought online by the resource monitor.

ABB Automation

165

MicroSCADA

3 Status Codes

166

5019

5020

5021

5022

5023

5024

5025

5031

5032

5033

5026

5027

5028

5029

5030

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_RESOURCE_ONLINE

The operation could not be completed because the cluster resource is online.

ERROR_QUORUM_RESOURCE

The cluster resource could not be deleted or brought offline because it is the quorum resource.

ERROR_NOT_QUORUM_CAPABLE

The cluster could not make the specified resource a quorum resource because it is not capable of being a quorum resource.

ERROR_CLUSTER_SHUTTING_DOWN

The cluster software is shutting down.

ERROR_INVALID_STATE

The group or resource is not in the correct state to perform the requested operation.

ERROR_RESOURCE_PROPERTIES_STORED

The properties were stored but not all changes will take effect until the next time the resource is brought online.

ERROR_NOT_QUORUM_CLASS

The cluster could not make the specified resource a quorum resource because it does not belong to a shared storage class.

ERROR_CORE_RESOURCE

The cluster resource could not be deleted since it is a core resource.

ERROR_QUORUM_RESOURCE_ONLINE_FAILED

The quorum resource failed to come online.

ERROR_QUORUMLOG_OPEN_FAILED

The quorum log could not be created or mounted successfully.

ERROR_CLUSTERLOG_CORRUPT

The cluster log is corrupt.

ERROR_CLUSTERLOG_RECORD_EXCEEDS_MAXSIZE

The record could not be written to the cluster log since it exceeds the maximum size.

ERROR_CLUSTERLOG_EXCEEDS_MAXSIZE

The cluster log exceeds its maximum size.

ERROR_CLUSTERLOG_CHKPOINT_NOT_FOUND

No checkpoint record was found in the cluster log.

ERROR_CLUSTERLOG_NOT_ENOUGH_SPACE

The minimum required disk space needed for logging is not available.

ABB Automation

1MRS751251-MEN

ABB Automation

5047

5048

5049

5050

5043

5044

5045

5046

5051

5052

5039

5040

5041

5042

5035

5036

5037

5038

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_NETWORK_NOT_AVAILABLE

A cluster network is not available for this operation.

ERROR_NODE_NOT_AVAILABLE

A cluster node is not available for this operation.

ERROR_ALL_NODES_NOT_AVAILABLE

All cluster nodes must be running to perform this operation.

ERROR_RESOURCE_FAILED

A cluster resource failed.

ERROR_CLUSTER_INVALID_NODE

The cluster node is not valid.

ERROR_CLUSTER_NODE_EXISTS

The cluster node already exists.

ERROR_CLUSTER_JOIN_IN_PROGRESS

A node is in the process of joining the cluster.

ERROR_CLUSTER_NODE_NOT_FOUND

The cluster node was not found.

ERROR_CLUSTER_LOCAL_NODE_NOT_FOUND

The cluster local node information was not found.

ERROR_CLUSTER_NETWORK_EXISTS

The cluster network already exists.

ERROR_CLUSTER_NETWORK_NOT_FOUND

The cluster network was not found.

ERROR_CLUSTER_NETINTERFACE_EXISTS

The cluster network interface already exists.

ERROR_CLUSTER_NETINTERFACE_NOT_FOUND

The cluster network interface was not found.

ERROR_CLUSTER_INVALID_REQUEST

The cluster request is not valid for this object.

ERROR_CLUSTER_INVALID_NETWORK_PROVIDER

The cluster network provider is not valid.

ERROR_CLUSTER_NODE_DOWN

The cluster node is down.

ERROR_CLUSTER_NODE_UNREACHABLE

The cluster node is not reachable.

ERROR_CLUSTER_NODE_NOT_MEMBER

The cluster node is not a member of the cluster.

167

MicroSCADA

3 Status Codes

168

5058

5059

5060

5061

5053

5054

5056

5057

5062

5063

5064

5065

5066

5067

5068

5069

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_CLUSTER_JOIN_NOT_IN_PROGRESS

A cluster join operation is not in progress.

ERROR_CLUSTER_INVALID_NETWORK

The cluster network is not valid.

ERROR_CLUSTER_NODE_UP

The cluster node is up.

ERROR_CLUSTER_IPADDR_IN_USE

The cluster IP address is already in use.

ERROR_CLUSTER_NODE_NOT_PAUSED

The cluster node is not paused.

ERROR_CLUSTER_NO_SECURITY_CONTEXT

No cluster security context is available.

ERROR_CLUSTER_NETWORK_NOT_INTERNAL

The cluster network is not configured for internal cluster communication.

ERROR_CLUSTER_NODE_ALREADY_UP

The cluster node is already up.

ERROR_CLUSTER_NODE_ALREADY_DOWN

The cluster node is already down.

ERROR_CLUSTER_NETWORK_ALREADY_ONLINE

The cluster network is already online.

ERROR_CLUSTER_NETWORK_ALREADY_OFFLINE

The cluster network is already offline.

ERROR_CLUSTER_NODE_ALREADY_MEMBER

The cluster node is already a member of the cluster.

ERROR_CLUSTER_LAST_INTERNAL_NETWORK

The cluster network is the only one configured for internal cluster communication between two or more active cluster nodes. The internal communication capability cannot be removed from the network.

ERROR_CLUSTER_NETWORK_HAS_DEPENDENTS

One or more cluster resources depend on the network to provide service to clients. The client access capability cannot be removed from the network.

ERROR_INVALID_OPERATION_ON_QUORUM

This operation cannot be performed on the cluster resource as it the quorum resource. You may not bring the quorum resource offline or modify its possible owners list.

ERROR_DEPENDENCY_NOT_ALLOWED

The cluster quorum resource is not allowed to have any dependencies.

ABB Automation

1MRS751251-MEN

ABB Automation

5070

5071

5072

5073

5074

5075

5076

5077

5078

5079

5080

5081

5083

5084

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_CLUSTER_NODE_PAUSED

The cluster node is paused.

ERROR_NODE_CANT_HOST_RESOURCE

The cluster resource cannot be brought online. The owner node cannot run this resource.

ERROR_CLUSTER_NODE_NOT_READY

The cluster node is not ready to perform the requested operation.

ERROR_CLUSTER_NODE_SHUTTING_DOWN

The cluster node is shutting down.

ERROR_CLUSTER_JOIN_ABORTED

The cluster join operation was aborted.

ERROR_CLUSTER_INCOMPATIBLE_VERSIONS

The cluster join operation failed due to incompatible software versions between the joining node and its sponsor.

ERROR_CLUSTER_MAXNUM_OF_RESOURCES_EXCEEDED

This resource cannot be created because the cluster has reached the limit on the number of resources it can monitor.

ERROR_CLUSTER_SYSTEM_CONFIG_CHANGED

The system configuration changed during the cluster join or form operation. The join or form operation was aborted.

ERROR_CLUSTER_RESOURCE_TYPE_NOT_FOUND

The specified resource type was not found.

ERROR_CLUSTER_RESTYPE_NOT_SUPPORTED

The specified node does not support a resource of this type. This may be due to version inconsistencies or due to the absence of the resource DLL on this node.

ERROR_CLUSTER_RESNAME_NOT_FOUND

The specified resource name is supported by this resource DLL. This may be due to a bad (or changed) name supplied to the resource DLL.

ERROR_CLUSTER_NO_RPC_PACKAGES_REGISTERED

No authentication package could be registered with the RPC server.

ERROR_CLUSTER_DATABASE_SEQMISMATCH

The join operation failed because the cluster database sequence number has changed or is incompatible with the locker node. This may happen during a join operation if the cluster database was changing

ERROR_RESMON_INVALID_STATE

The resource monitor will not allow the fail operation to be performed while the resource is in its current state. This may happen if the resource is in a pending state.

169

MicroSCADA

3 Status Codes

170

6000

6001

6002

6003

6004

6005

6118

7001

7002

7003

7004

6006

6007

6008

6009

7005

7006

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_ENCRYPTION_FAILED

The specified file could not be encrypted.

ERROR_DECRYPTION_FAILED

The specified file could not be decrypted.

ERROR_FILE_ENCRYPTED

The specified file is encrypted and the user does not have the ability to decrypt it.

ERROR_NO_RECOVERY_POLICY

There is no encryption recovery policy configured for this system.

ERROR_NO_EFS

The required encryption driver is not loaded for this system.

ERROR_WRONG_EFS

The file was encrypted with a different encryption driver than is currently loaded.

ERROR_NO_USER_KEYS

There are no EFS keys defined for the user.

ERROR_FILE_NOT_ENCRYPTED

The specified file is not encrypted.

ERROR_NOT_EXPORT_FORMAT

The specified file is not in the defined EFS export format.

ERROR_FILE_READ_ONLY

The specified file is read only.

ERROR_NO_BROWSER_SERVERS_FOUND

The list of servers for this workgroup is not currently available

ERROR_CTX_WINSTATION_NAME_INVALID

The specified session name is invalid.

ERROR_CTX_INVALID_PD

The specified protocol driver is invalid.

ERROR_CTX_PD_NOT_FOUND

The specified protocol driver was not found in the system path.

ERROR_CTX_WD_NOT_FOUND

The specified terminal connection driver was not found in the system path.

ERROR_CTX_CANNOT_MAKE_EVENTLOG_ENTRY

A registry key for event logging could not be created for this session.

ERROR_CTX_SERVICE_NAME_COLLISION

A service with the same name already exists on the system.

ABB Automation

1MRS751251-MEN

ABB Automation

7007

7008

7009

7010

7011

7012

7013

7014

7022

7023

7025

7015

7016

7017

7035

7037

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_CTX_CLOSE_PENDING

A close operation is pending on the session.

ERROR_CTX_NO_OUTBUF

There are no free output buffers available.

ERROR_CTX_MODEM_INF_NOT_FOUND

The MODEM.INF file was not found.

ERROR_CTX_INVALID_MODEMNAME

The modem name was not found in MODEM.INF.

ERROR_CTX_MODEM_RESPONSE_ERROR

The modem did not accept the command sent to it. Verify that the configured modem name matches the attached modem.

ERROR_CTX_MODEM_RESPONSE_TIMEOUT

The modem did not respond to the command sent to it. Verify that the modem is properly cabled and powered on.

ERROR_CTX_MODEM_RESPONSE_NO_CARRIER

Carrier detect has failed or carrier has been dropped due to disconnect.

ERROR_CTX_MODEM_RESPONSE_NO_DIALTONE

Dial tone not detected within the required time. Verify that the phone cable is properly attached and functional.

ERROR_CTX_MODEM_RESPONSE_BUSY

Busy signal detected at remote site on callback.

ERROR_CTX_MODEM_RESPONSE_VOICE

Voice detected at remote site on callback.

ERROR_CTX_TD_ERROR

Transport driver error

ERROR_CTX_WINSTATION_NOT_FOUND

The specified session cannot be found.

ERROR_CTX_WINSTATION_ALREADY_EXISTS

The specified session name is already in use.

ERROR_CTX_BAD_VIDEO_MODE

An attempt has been made to connect to a session whose video mode is not supported by the current client.

ERROR_CTX_GRAPHICS_INVALID

The application attempted to enable DOS graphics mode. DOS graphics mode is not supported.

ERROR_CTX_LOGON_DISABLED

Your interactive logon privilege has been disabled. Please contact your administrator.

171

MicroSCADA

3 Status Codes

172

7038

7044

7045

7049

7051

7040

7041

7042

7054

7055

8003

8004

8005

8006

7056

8001

8002

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_CTX_NOT_CONSOLE

The requested operation can be performed only on the system console.

This is most often the result of a driver or system DLL requiring direct console access.

ERROR_CTX_CLIENT_QUERY_TIMEOUT

The client failed to respond to the server connect message.

ERROR_CTX_CONSOLE_DISCONNECT

Disconnecting the console session is not supported.

ERROR_CTX_CONSOLE_CONNECT

Reconnecting a disconnected session to the console is not supported.

ERROR_CTX_SHADOW_DENIED

The request to shadow another session was denied.

ERROR_CTX_WINSTATION_ACCESS_DENIED

The requested session access is denied.

ERROR_CTX_INVALID_WD

The specified terminal connection driver is invalid.

ERROR_CTX_SHADOW_DISABLED

The requested session is not configured to allow shadowing.

ERROR_CTX_LICENSE_NOT_AVAILABLE

The system has reached its licensed logon limit. Please try again later.

ERROR_CTX_LICENSE_CLIENT_INVALID

The client you are using is not licensed to use this system. Your logon request is denied.

ERROR_CTX_LICENSE_EXPIRED

The system license has expired. Your logon request is denied.

FRS_ERR_INVALID_API_SEQUENCE

The file replication service API was called incorrectly.

FRS_ERR_STARTING_SERVICE

The file replication service cannot be started.

FRS_ERR_STOPPING_SERVICE

The file replication service cannot be stopped.

FRS_ERR_INTERNAL_API

The file replication service API terminated the request.

FRS_ERR_INTERNAL

The file replication service terminated the request.

FRS_ERR_SERVICE_COMM

The file replication service cannot be contacted.

ABB Automation

1MRS751251-MEN

ABB Automation

8007

8008

8009

8010

8011

8012

8013

8014

8015

8016

8017

8201

8202

8203

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

FRS_ERR_INSUFFICIENT_PRIV

The file replication service cannot satisfy the request because the user is not a member of the Administrators group.

FRS_ERR_AUTHENTICATION

The file replication service cannot satisfy the request because authenticated RPC is not available.

FRS_ERR_PARENT_INSUFFICIENT_PRIV

The file replication service cannot satisfy the request because the user is not a member of Administrators group on the domain controller.

FRS_ERR_PARENT_AUTHENTICATION

The file replication service cannot satisfy the request because authenticated RPC is not available on the domain controller.

FRS_ERR_CHILD_TO_PARENT_COMM

The file replication service cannot communicate with the file replication service on the domain controller.

FRS_ERR_PARENT_TO_CHILD_COMM

The file replication service on the domain controller cannot communicate with the file replication service on this computer.

FRS_ERR_SYSVOL_POPULATE

The file replication service cannot populate the system volume because of an internal error.

FRS_ERR_SYSVOL_POPULATE_TIMEOUT

The file replication service cannot populate the system volume because of an internal timeout.

FRS_ERR_SYSVOL_IS_BUSY

The file replication service cannot process the request. The system volume is busy with a previous request.

FRS_ERR_SYSVOL_DEMOTE

The file replication service cannot stop replicating the system volume because of an internal error.

FRS_ERR_INVALID_SERVICE_PARAMETER

The file replication service detected an invalid parameter.

ERROR_DS_MEMBERSHIP_EVALUATED_LOCALLY

The directory service evaluated group memberships locally.

ERROR_DS_NO_ATTRIBUTE_OR_VALUE

The specified directory service attribute or value does not exist.

ERROR_DS_INVALID_ATTRIBUTE_SYNTAX

The attribute syntax specified to the directory service is invalid.

173

MicroSCADA

3 Status Codes

174

8208

8209

8210

8204

8205

8206

8207

8211

8212

8213

8214

8215

8216

8217

8218

8219

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_DS_ATTRIBUTE_TYPE_UNDEFINED

The attribute type specified to the directory service is not defined.

ERROR_DS_ATTRIBUTE_OR_VALUE_EXISTS

The specified directory service attribute or value already exists.

ERROR_DS_BUSY

The directory service is busy.

ERROR_DS_UNAVAILABLE

The directory service is unavailable.

ERROR_DS_NO_RIDS_ALLOCATED

The directory service was unable to allocate a relative identifier.

ERROR_DS_NO_MORE_RIDS

The directory service has exhausted the pool of relative identifiers.

ERROR_DS_INCORRECT_ROLE_OWNER

The requested operation could not be performed because the directory service is not the master for that type of operation.

ERROR_DS_RIDMGR_INIT_ERROR

The directory service was unable to initialize the subsystem that allocates relative identifiers.

ERROR_DS_OBJ_CLASS_VIOLATION

The requested operation did not satisfy one or more constraints associated with the class of the object.

ERROR_DS_CANT_ON_NON_LEAF

The directory service can perform the requested operation only on a leaf object.

ERROR_DS_CANT_ON_RDN

The directory service cannot perform the requested operation on the RDN attribute of an object.

ERROR_DS_CANT_MOD_OBJ_CLASS

The directory service detected an attempt to modify the object class of an object.

ERROR_DS_CROSS_DOM_MOVE_ERROR

The requested cross-domain move operation could not be performed.

ERROR_DS_GC_NOT_AVAILABLE

Unable to contact the global catalog server.

ERROR_SHARED_POLICY

The policy object is shared and can only be modified at the root.

ERROR_POLICY_OBJECT_NOT_FOUND

The policy object does not exist.

ABB Automation

1MRS751251-MEN

ABB Automation

8233

8234

8235

8236

8229

8230

8231

8232

8237

8238

8225

8226

8227

8228

8220

8221

8222

8224

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_POLICY_ONLY_IN_DS

The requested policy information is only in the directory service.

ERROR_PROMOTION_ACTIVE

A domain controller promotion is currently active.

ERROR_NO_PROMOTION_ACTIVE

A domain controller promotion is not currently active

ERROR_DS_OPERATIONS_ERROR

An operations error occurred.

ERROR_DS_PROTOCOL_ERROR

A protocol error occurred.

ERROR_DS_TIMELIMIT_EXCEEDED

The time limit for this request was exceeded.

ERROR_DS_SIZELIMIT_EXCEEDED

The size limit for this request was exceeded.

ERROR_DS_ADMIN_LIMIT_EXCEEDED

The administrative limit for this request was exceeded.

ERROR_DS_COMPARE_FALSE

The compare response was false.

ERROR_DS_COMPARE_TRUE

The compare response was true.

ERROR_DS_AUTH_METHOD_NOT_SUPPORTED

The requested authentication method is not supported by the server.

ERROR_DS_STRONG_AUTH_REQUIRED

A more secure authentication method is required for this server.

ERROR_DS_INAPPROPRIATE_AUTH

Inappropriate authentication.

ERROR_DS_AUTH_UNKNOWN

The authentication mechanism is unknown.

ERROR_DS_REFERRAL

A referral was returned from the server.

ERROR_DS_UNAVAILABLE_CRIT_EXTENSION

The server does not support the requested critical extension.

ERROR_DS_CONFIDENTIALITY_REQUIRED

This request requires a secure connection.

ERROR_DS_INAPPROPRIATE_MATCHING

Inappropriate matching.

175

MicroSCADA

3 Status Codes

176

8251

8252

8253

8254

8247

8248

8249

8250

8255

8256

8243

8244

8245

8246

8239

8240

8241

8242

Status Codes

Technical Reference Manual

ERROR_DS_CONSTRAINT_VIOLATION

A constraint violation occurred.

ERROR_DS_NO_SUCH_OBJECT

There is no such object on the server.

ERROR_DS_ALIAS_PROBLEM

There is an alias problem.

ERROR_DS_INVALID_DN_SYNTAX

An invalid dn syntax has been specified.

ERROR_DS_IS_LEAF

The object is a leaf object.

ERROR_DS_ALIAS_DEREF_PROBLEM

There is an alias dereferencing problem.

ERROR_DS_UNWILLING_TO_PERFORM

The server is unwilling to process the request.

ERROR_DS_LOOP_DETECT

A loop has been detected.

ERROR_DS_NAMING_VIOLATION

There is a naming violation.

ERROR_DS_OBJECT_RESULTS_TOO_LARGE

The result set is too large.

ERROR_DS_AFFECTS_MULTIPLE_DSAS

The operation affects multiple DSAs

ERROR_DS_SERVER_DOWN

The server is not operational.

ERROR_DS_LOCAL_ERROR

A local error has occurred.

ERROR_DS_ENCODING_ERROR

An encoding error has occurred.

ERROR_DS_DECODING_ERROR

A decoding error has occurred.

ERROR_DS_FILTER_UNKNOWN

The search filter cannot be recognized.

ERROR_DS_PARAM_ERROR

One or more parameters are illegal.

ERROR_DS_NOT_SUPPORTED

The specified method is not supported.

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

ABB Automation

8257

8258

8259

8260

8301

8302

8303

8304

8305

8306

8307

8308

8309

8310

8311

8312

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DS_NO_RESULTS_RETURNED

No results were returned.

ERROR_DS_CONTROL_NOT_FOUND

The specified control is not supported by the server.

ERROR_DS_CLIENT_LOOP

A referral loop was detected by the client.

ERROR_DS_REFERRAL_LIMIT_EXCEEDED

The preset referral limit was exceeded.

ERROR_DS_ROOT_MUST_BE_NC

The root object must be the head of a naming context. The root object cannot have an instantiated parent.

ERROR_DS_ADD_REPLICA_INHIBITED

The add replica operation cannot be performed. The naming context must be writable in order to create the replica.

ERROR_DS_ATT_NOT_DEF_IN_SCHEMA

A reference to an attribute that is not defined in the schema occurred.

ERROR_DS_MAX_OBJ_SIZE_EXCEEDED

The maximum size of an object has been exceeded.

ERROR_DS_OBJ_STRING_NAME_EXISTS

An attempt was made to add an object to the directory with a name that is already in use.

ERROR_DS_NO_RDN_DEFINED_IN_SCHEMA

An attempt was made to add an object of a class that does not have an

RDN defined in the schema.

ERROR_DS_RDN_DOESNT_MATCH_SCHEMA

An attempt was made to add an object using an RDN that is not the RDN defined in the schema.

ERROR_DS_NO_REQUESTED_ATTS_FOUND

None of the requested attributes were found on the objects.

ERROR_DS_USER_BUFFER_TO_SMALL

The user buffer is too small.

ERROR_DS_ATT_IS_NOT_ON_OBJ

The attribute specified in the operation is not present on the object.

ERROR_DS_ILLEGAL_MOD_OPERATION

Illegal modify operation. Some aspect of the modification is not permitted.

ERROR_DS_OBJ_TOO_LARGE

The specified object is too large.

177

MicroSCADA

3 Status Codes

178

8313

8314

8315

8316

8317

8326

8327

8328

8329

8323

8324

8325

8318

8321

8322

8330

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_DS_BAD_INSTANCE_TYPE

The specified instance type is not valid.

ERROR_DS_MASTERDSA_REQUIRED

The operation must be performed at the master DSA. The DNS root attribute is missing on the cross-reference object.

ERROR_DS_OBJECT_CLASS_REQUIRED

The object class attribute must be specified.

ERROR_DS_MISSING_REQUIRED_ATT

A required attribute is missing.

ERROR_DS_ATT_NOT_DEF_FOR_CLASS

An attempt was made to modify an object to include an attribute that is not legal for its class

ERROR_DS_ATT_ALREADY_EXISTS

The specified attribute is already present on the object.

ERROR_DS_SINGLE_VALUE_CONSTRAINT

An attribute’s single value constraint has been violated.

ERROR_DS_RANGE_CONSTRAINT

An attribute’s range constraint has been violated.

ERROR_DS_ATT_VAL_ALREADY_EXISTS

The specified value already exists.

ERROR_DS_CANT_REM_MISSING_ATT

The attribute cannot be removed because it is not present on the object.

ERROR_DS_CANT_REM_MISSING_ATT_VAL

The attribute value cannot be removed because it is not present on the object.

ERROR_DS_ROOT_CANT_BE_SUBREF

The specified root object cannot be a subref.

ERROR_DS_NO_CHAINING

Chaining is not permitted.

ERROR_DS_NO_CHAINED_EVAL

Chained evaluation is not permitted.

ERROR_DS_NO_PARENT_OBJECT

The operation could not be performed because the object’s parent is either uninstantiated or deleted.

ERROR_DS_PARENT_IS_AN_ALIAS

Having a parent that is an alias is not permitted. Aliases are leaf objects.

ABB Automation

1MRS751251-MEN

ABB Automation

8332

8337

8338

8340

8341

8333

8334

8335

8336

8342

8343

8344

8345

8346

8347

8348

8349

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DS_CHILDREN_EXIST

The operation cannot be performed because child objects exist. This operation can only be performed on a leaf object.

ERROR_DS_OBJ_NOT_FOUND

Directory object not found.

ERROR_DS_ALIASED_OBJ_MISSING

The aliased object is missing.

ERROR_DS_BAD_NAME_SYNTAX

The object name has bad syntax.

ERROR_DS_ALIAS_POINTS_TO_ALIAS

It is not permitted for an alias to refer to another alias.

ERROR_DS_CANT_DEREF_ALIAS

The alias cannot be dereferenced.

ERROR_DS_OUT_OF_SCOPE

The operation is out of scope.

ERROR_DS_CANT_DELETE_DSA_OBJ

The DSA object cannot be deleted.

ERROR_DS_GENERIC_ERROR

A directory service error has occurred.

ERROR_DS_DSA_MUST_BE_INT_MASTER

The operation can only be performed on an internal master DSA object.

ERROR_DS_CLASS_NOT_DSA

The object must be of class DSA.

ERROR_DS_INSUFF_ACCESS_RIGHTS

Insufficient access rights to perform the operation.

ERROR_DS_ILLEGAL_SUPERIOR

The object cannot be added because the parent is not on the list of possible superiors.

ERROR_DS_ATTRIBUTE_OWNED_BY_SAM

Access to the attribute is not permitted because the attribute is owned by the Security Accounts Manager (SAM).

ERROR_DS_NAME_TOO_MANY_PARTS

The name has too many parts.

ERROR_DS_NAME_TOO_LONG

The name is too long.

ERROR_DS_NAME_VALUE_TOO_LONG

The name value is too long.

179

MicroSCADA

3 Status Codes

180

8354

8355

8356

8357

8350

8351

8352

8353

8358

8359

8360

8361

8362

8363

8364

8365

8366

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_DS_NAME_UNPARSEABLE

The directory service encountered an error parsing a name.

ERROR_DS_NAME_TYPE_UNKNOWN

The directory service cannot get the attribute type for a name.

ERROR_DS_NOT_AN_OBJECT

The name does not identify an object; the name identifies a phantom.

ERROR_DS_SEC_DESC_TOO_SHORT

The security descriptor is too short.

ERROR_DS_SEC_DESC_INVALID

The security descriptor is invalid.

ERROR_DS_NO_DELETED_NAME

Failed to create name for deleted object.

ERROR_DS_SUBREF_MUST_HAVE_PARENT

The parent of a new subref must exist.

ERROR_DS_NCNAME_MUST_BE_NC

The object must be a naming context.

ERROR_DS_CANT_ADD_SYSTEM_ONLY

It is not permitted to add an attribute which is owned by the system.

ERROR_DS_CLASS_MUST_BE_CONCRETE

The class of the object must be structural; you cannot instantiate an abstract class.

ERROR_DS_INVALID_DMD

The schema object could not be found.

ERROR_DS_OBJ_GUID_EXISTS

A local object with this GUID (dead or alive) already exists.

ERROR_DS_NOT_ON_BACKLINK

The operation cannot be performed on a back link.

ERROR_DS_NO_CROSSREF_FOR_NC

The cross reference for the specified naming context could not be found.

ERROR_DS_SHUTTING_DOWN

The operation could not be performed because the directory service is shutting down.

ERROR_DS_UNKNOWN_OPERATION

The directory service request is invalid.

ERROR_DS_INVALID_ROLE_OWNER

The role owner attribute could not be read.

ABB Automation

1MRS751251-MEN

ABB Automation

8367

8380

8381

8382

8383

8376

8377

8378

8379

8372

8373

8374

8375

8368

8369

8370

8371

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DS_COULDNT_CONTACT_FSMO

The requested FSMO operation failed. The current FSMO holder could not be reached.

ERROR_DS_CROSS_NC_DN_RENAME

Modification of a DN across a naming context is not permitted.

ERROR_DS_CANT_MOD_SYSTEM_ONLY

The attribute cannot be modified because it is owned by the system.

ERROR_DS_REPLICATOR_ONLY

Only the replicator can perform this function.

ERROR_DS_OBJ_CLASS_NOT_DEFINED

The specified class is not defined.

ERROR_DS_OBJ_CLASS_NOT_SUBCLASS

The specified class is not a subclass.

ERROR_DS_NAME_REFERENCE_INVALID

The name reference is invalid.

ERROR_DS_CROSS_REF_EXISTS

A cross reference already exists.

ERROR_DS_CANT_DEL_MASTER_CROSSREF

It is not permitted to delete a master cross reference.

ERROR_DS_SUBTREE_NOTIFY_NOT_NC_HEAD

Subtree notifications are only supported on NC heads.

ERROR_DS_NOTIFY_FILTER_TOO_COMPLEX

Notification filter is too complex.

ERROR_DS_DUP_RDN

Schema update failed: duplicate RDN.

ERROR_DS_DUP_OID

Schema update failed: duplicate OID

ERROR_DS_DUP_MAPI_ID

Schema update failed: duplicate MAPI identifier.

ERROR_DS_DUP_SCHEMA_ID_GUID

Schema update failed: duplicate schema-id GUID.

ERROR_DS_DUP_LDAP_DISPLAY_NAME

Schema update failed: duplicate LDAP display name.

ERROR_DS_SEMANTIC_ATT_TEST

Schema update failed: range-lower less than range upper

181

MicroSCADA

3 Status Codes

182

8384

8385

8386

8387

8388

8389

8390

8391

8396

8397

8398

8399

8400

8392

8393

8394

8395

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_DS_SYNTAX_MISMATCH

Schema update failed: syntax mismatch

ERROR_DS_EXISTS_IN_MUST_HAVE

Schema deletion failed: attribute is used in must-contain

ERROR_DS_EXISTS_IN_MAY_HAVE

Schema deletion failed: attribute is used in may-contain

ERROR_DS_NONEXISTENT_MAY_HAVE

Schema update failed: attribute in may-contain does not exist

ERROR_DS_NONEXISTENT_MUST_HAVE

Schema update failed: attribute in must-contain does not exist

ERROR_DS_AUX_CLS_TEST_FAIL

Schema update failed: class in aux-class list does not exist or is not an auxiliary class

ERROR_DS_NONEXISTENT_POSS_SUP

Schema update failed: class in poss-superiors does not exist

ERROR_DS_SUB_CLS_TEST_FAIL

Schema update failed: class in subclassof list does not exist or does not satisfy hierarchy rules

ERROR_DS_BAD_RDN_ATT_ID_SYNTAX

Schema update failed: Rdn-Att-Id has wrong syntax

ERROR_DS_EXISTS_IN_AUX_CLS

Schema deletion failed: class is used as auxiliary class

ERROR_DS_EXISTS_IN_SUB_CLS

Schema deletion failed: class is used as sub class

ERROR_DS_EXISTS_IN_POSS_SUP

Schema deletion failed: class is used as poss superior

ERROR_DS_RECALCSCHEMA_FAILED

Schema update failed in recalculating validation cache.

ERROR_DS_TREE_DELETE_NOT_FINISHED

The tree deletion is not finished.

ERROR_DS_CANT_DELETE

The requested delete operation could not be performed.

ERROR_DS_ATT_SCHEMA_REQ_ID

Cannot read the governs class identifier for the schema record.

ERROR_DS_BAD_ATT_SCHEMA_SYNTAX

The attribute schema has bad syntax.

ABB Automation

1MRS751251-MEN

ABB Automation

8413

8414

8415

8416

8417

8409

8410

8411

8412

8405

8406

8407

8408

8401

8402

8403

8404

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DS_CANT_CACHE_ATT

The attribute could not be cached.

ERROR_DS_CANT_CACHE_CLASS

The class could not be cached.

ERROR_DS_CANT_REMOVE_ATT_CACHE

The attribute could not be removed from the cache.

ERROR_DS_CANT_REMOVE_CLASS_CACHE

The class could not be removed from the cache.

ERROR_DS_CANT_RETRIEVE_DN

The distinguished name attribute could not be read.

ERROR_DS_MISSING_SUPREF

A required subref is missing.

ERROR_DS_CANT_RETRIEVE_INSTANCE

The instance type attribute could not be retrieved.

ERROR_DS_CODE_INCONSISTENCY

An internal error has occurred.

ERROR_DS_DATABASE_ERROR

A database error has occurred.

ERROR_DS_GOVERNSID_MISSING

The attribute GOVERNSID is missing.

ERROR_DS_MISSING_EXPECTED_ATT

An expected attribute is missing.

ERROR_DS_NCNAME_MISSING_CR_REF

The specified naming context is missing a cross reference.

ERROR_DS_SECURITY_CHECKING_ERROR

A security checking error has occurred.

ERROR_DS_SCHEMA_NOT_LOADED

The schema is not loaded.

ERROR_DS_SCHEMA_ALLOC_FAILED

Schema allocation failed.

ERROR_DS_ATT_SCHEMA_REQ_SYNTAX

Failed to obtain the required syntax for the attribute schema.

ERROR_DS_GCVERIFY_ERROR

The global catalog verification failed. The global catalog is not available or does not support the operation. Some part of the directory is currently not available.

183

MicroSCADA

3 Status Codes

184

8418

8431

8432

8435

8427

8428

8429

8430

8423

8424

8425

8426

8419

8420

8421

8422

8436

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_DS_DRA_SCHEMA_MISMATCH

The replication operation failed because of a schema mismatch between the servers involved.

ERROR_DS_CANT_FIND_DSA_OBJ

The DSA object could not be found.

ERROR_DS_CANT_FIND_EXPECTED_NC

The naming context could not be found.

ERROR_DS_CANT_FIND_NC_IN_CACHE

The naming context could not be found in the cache.

ERROR_DS_CANT_RETRIEVE_CHILD

The child object could not be retrieved.

ERROR_DS_SECURITY_ILLEGAL_MODIFY

The modification was not permitted for security reasons.

ERROR_DS_CANT_REPLACE_HIDDEN_REC

The operation cannot replace the hidden record.

ERROR_DS_BAD_HIERARCHY_FILE

The hierarchy file is invalid.

ERROR_DS_BUILD_HIERARCHY_TABLE_FAILED

The attempt to build the hierarchy table failed.

ERROR_DS_CONFIG_PARAM_MISSING

The directory configuration parameter is missing from the registry.

ERROR_DS_COUNTING_AB_INDICES_FAILED

The attempt to count the address book indices failed.

ERROR_DS_HIERARCHY_TABLE_MALLOC_FAILED

The allocation of the hierarchy table failed.

ERROR_DS_INTERNAL_FAILURE

The directory service encountered an internal failure.

ERROR_DS_UNKNOWN_ERROR

The directory service encountered an unknown failure.

ERROR_DS_ROOT_REQUIRES_CLASS_TOP

A root object requires a class of ’top’.

ERROR_DS_UNABLE_TO_SURRENDER_ROLES

The directory service was unable to transfer ownership of one or more floating single-master operation roles to other servers.

ERROR_DS_DRA_GENERIC

The replication operation failed.

ABB Automation

1MRS751251-MEN

ABB Automation

8437

8438

8439

8440

8441

8442

8443

8444

8445

8446

8447

8448

8449

8450

8451

8452

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DS_DRA_INVALID_PARAMETER

An invalid parameter was specified for this replication operation.

ERROR_DS_DRA_BUSY

The Windows NT directory service is too busy to complete the replication operation at this time.

ERROR_DS_DRA_BAD_DN

The distinguished name specified for this replication operation is invalid.

ERROR_DS_DRA_BAD_NC

The naming context specified for this replication operation is invalid.

ERROR_DS_DRA_DN_EXISTS

The distinguished name specified for this replication operation already exists.

ERROR_DS_DRA_INTERNAL_ERROR

The replication system encountered an internal error.

ERROR_DS_DRA_INCONSISTENT_DIT

The replication operation encountered a database inconsistency.

ERROR_DS_DRA_CONNECTION_FAILED

The server specified for this replication operation could not be contacted.

ERROR_DS_DRA_BAD_INSTANCE_TYPE

The replication operation encountered an object with an invalid instance type.

ERROR_DS_DRA_OUT_OF_MEM

The replication operation failed to allocate memory.

ERROR_DS_DRA_MAIL_PROBLEM

The replication operation encountered an error with the mail system.

ERROR_DS_DRA_REF_ALREADY_EXISTS

The replication reference information for the target server already exists.

ERROR_DS_DRA_REF_NOT_FOUND

The replication reference information for the target server does not exist.

ERROR_DS_DRA_OBJ_IS_REP_SOURCE

The naming context cannot be removed because it is replicated to another server.

ERROR_DS_DRA_DB_ERROR

The replication operation encountered a database error.

ERROR_DS_DRA_NO_REPLICA

The naming context is in the process of being removed or is not replicated from the specified server.

185

MicroSCADA

3 Status Codes

186

8453

8454

8458

8459

8460

8455

8456

8457

8461

8462

8463

8464

8465

8467

8468

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_DS_DRA_ACCESS_DENIED

Replication access was denied.

ERROR_DS_DRA_NOT_SUPPORTED

The requested operation is not supported by this version of the Windows

NT directory service.

ERROR_DS_DRA_RPC_CANCELLED

The replication remote procedure call was cancelled.

ERROR_DS_DRA_SOURCE_DISABLED

The source server is currently rejecting replication requests.

ERROR_DS_DRA_SINK_DISABLED

The destination server is currently rejecting replication requests.

ERROR_DS_DRA_NAME_COLLISION

The replication operation failed due to a collision of object names.

ERROR_DS_DRA_SOURCE_REINSTALLED

The replication source has been reinstalled.

ERROR_DS_DRA_MISSING_PARENT

The replication operation failed because a required parent object is missing.

ERROR_DS_DRA_PREEMPTED

The replication operation was preempted.

ERROR_DS_DRA_ABANDON_SYNC

The replication synchronization attempt was abandoned because of a lack of updates.

ERROR_DS_DRA_SHUTDOWN

The replication operation was terminated because the system is shutting down.

ERROR_DS_DRA_INCOMPATIBLE_PARTIAL_SET

The replication synchronization attempt failed as the destination partial attribute set is not a subset of source partial attribute set.

ERROR_DS_DRA_SOURCE_IS_PARTIAL_REPLICA

The replication synchronization attempt failed because a master replica attempted to sync from a partial replica.

ERROR_DS_INSTALL_SCHEMA_MISMATCH

A schema mismatch is detected between the source and the build used during a replica install. The replica cannot be installed.

ERROR_DS_DUP_LINK_ID

Schema update failed: An attribute with the same link identifier already exists.

ABB Automation

1MRS751251-MEN

ABB Automation

8469

8470

8471

8474

8475

8476

8477

8479

8480

8481

8482

8483

8484

8485

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DS_NAME_ERROR_RESOLVING

Name translation: Generic processing error.

ERROR_DS_NAME_ERROR_NOT_FOUND

Name translation: Could not find the name or insufficient right to see name.

ERROR_DS_NAME_ERROR_NOT_UNIQUE

Name translation: Input name mapped to more than one output name.

ERROR_DS_NAME_ERROR_NO_SYNTACTICAL_MAPPING

Name translation: Unable to perform purely syntactical mapping at the client without going out to the wire.

ERROR_DS_CONSTRUCTED_ATT_MOD

Modification of a constructed att is not allowed.

ERROR_DS_WRONG_OM_OBJ_CLASS

The OM-Object-Class specified is incorrect for an attribute with the specified syntax.

ERROR_DS_DRA_REPL_PENDING

The replication request has been posted; waiting for reply.

ERROR_DS_INVALID_LDAP_DISPLAY_NAME

The LDAP display name of the class or attribute contains non-ASCII characters.

ERROR_DS_NON_BASE_SEARCH

The requested search operation is only supported for base searches.

ERROR_DS_CANT_RETRIEVE_ATTS

The search failed to retrieve attributes from the database.

ERROR_DS_BACKLINK_WITHOUT_LINK

The schema update operation tried to add a backward link attribute that has no corresponding forward link.

ERROR_DS_EPOCH_MISMATCH

Source and destination of a cross domain move do not agree on the object’s epoch number. Either source or destination does not have the latest version of the object.

ERROR_DS_SRC_NAME_MISMATCH

Source and destination of a cross domain move do not agree on the object’s current name. Either source or destination does not have the latest version of the object.

ERROR_DS_SRC_AND_DST_NC_IDENTICAL

Source and destination of a cross domain move operation are identical.

Caller should use local move operation instead of cross domain move operation.

187

MicroSCADA

3 Status Codes

188

8486

8487

8488

8489

8490

8491

8495

8496

8497

8498

8499

8500

8501

Status Codes

Technical Reference Manual

1MRS751251-MEN

ERROR_DS_DST_NC_MISMATCH

Source and destination for a cross domain move are not in agreement on the naming contexts in the forest. Either source or destination does not have the latest version of the Partitions container.

ERROR_DS_NOT_AUTHORITIVE_FOR_DST_NC

Destination of a cross domain move is not authoritative for the destination naming context.

ERROR_DS_SRC_GUID_MISMATCH

Source and destination of a cross domain move do not agree on the identity of the source object. Either source or destination does not have the latest version of the source object.

ERROR_DS_CANT_MOVE_DELETED_OBJECT

Object being moved across domains is already known to be deleted by the destination server. The source server does not have the latest version of the source object.

ERROR_DS_PDC_OPERATION_IN_PROGRESS

Another operation which requires exclusive access to the PDC PSMO is already in progress.

ERROR_DS_CROSS_DOMAIN_CLEANUP_REQD

A cross domain move operation failed such that the two versions of the moved object exist - one each in the source and destination domains. The destination object needs to be removed to restore the sy

ERROR_DS_CR_IMPOSSIBLE_TO_VALIDATE

The directory cannot validate the proposed naming context name because it does not hold a replica of the naming context above the proposed naming context.

ERROR_DS_DST_DOMAIN_NOT_NATIVE

Destination of a cross domain move must be in native mode.

ERROR_DS_MISSING_INFRASTRUCTURE_CONTAINER

The operation can not be performed because the server does not have an infrastructure container in the domain of interest.

ERROR_DS_CANT_MOVE_ACCOUNT_GROUP

Cross domain move of account groups is not allowed.

ERROR_DS_CANT_MOVE_RESOURCE_GROUP

Cross domain move of resource groups is not allowed.

ERROR_DS_INVALID_SEARCH_FLAG

The search flags for the attribute are invalid. The ANR bit is valid only on attributes of Unicode or Teletex strings.

ERROR_DS_NO_TREE_DELETE_ABOVE_NC

Tree deletions starting at an object which has an NC head as a descendant are not allowed.

ABB Automation

1MRS751251-MEN

ABB Automation

8502

8503

8505

9004

9005

9009

9010

8506

9001

9002

9003

9016

9017

9018

9501

9502

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

ERROR_DS_COULDNT_LOCK_TREE_FOR_DELETE

The directory service failed to lock a tree in preparation for a tree deletion because the tree was in use.

ERROR_DS_COULDNT_IDENTIFY_OBJECTS_FOR_TREE_

DELETE

The directory service failed to identify the list of objects to delete while attempting a tree deletion.

ERROR_DS_SENSITIVE_GROUP_VIOLATION

Only an administrator can modify the membership list of an administrative group.

ERROR_DS_CANT_MOD_PRIMARYGROUPID

Cannot change the primary group ID of a domain controller account.

DNS_ERROR_RCODE_FORMAT_ERROR

DNS server unable to interpret format.

DNS_ERROR_RCODE_SERVER_FAILURE

DNS server failure.

DNS_ERROR_RCODE_NAME_ERROR

DNS name does not exist.

DNS_ERROR_RCODE_NOT_IMPLEMENTED

DNS request not supported by name server.

DNS_ERROR_RCODE_REFUSED

DNS operation refused.

DNS_ERROR_RCODE_NOTAUTH

DNS server not authoritative for zone.

DNS_ERROR_RCODE_NOTZONE

DNS name in update or prereq is not in zone.

DNS_ERROR_RCODE_BADSIG

DNS signature failed to verify.

DNS_ERROR_RCODE_BADKEY

DNS bad key.

DNS_ERROR_RCODE_BADTIME

DNS signature validity expired.

DNS_INFO_NO_RECORDS

No records found for given DNS query.

DNS_ERROR_BAD_PACKET

Bad DNS packet.

189

MicroSCADA

3 Status Codes

190

9602

9603

9604

9605

9557

9558

9559

9601

9606

9607

9553

9554

9555

9556

9503

9505

9551

9552

Status Codes

Technical Reference Manual

DNS_ERROR_NO_PACKET

No DNS packet.

DNS_ERROR_UNSECURE_PACKET

Unsecured DNS packet.

DNS_ERROR_INVALID_TYPE

Invalid DNS type.

DNS_ERROR_INVALID_IP_ADDRESS

Invalid IP address.

DNS_ERROR_INVALID_PROPERTY

Invalid property.

DNS_ERROR_TRY_AGAIN_LATER

Try DNS operation again later.

DNS_ERROR_NOT_UNIQUE

Record for given name and type is not unique.

DNS_ERROR_NON_RFC_NAME

DNS name does not comply with RFC specifications.

DNS_STATUS_FQDN

DNS name is a fully-qualified DNS name.

DNS_STATUS_DOTTED_NAME

DNS name is dotted (multi-label).

DNS_STATUS_SINGLE_PART_NAME

DNS name is a single-part name.

DNS_ERROR_ZONE_DOES_NOT_EXIST

DNS zone does not exist.

DNS_ERROR_NO_ZONE_INFO

DNS zone information not available.

DNS_ERROR_INVALID_ZONE_OPERATION

Invalid operation for DNS zone.

DNS_ERROR_ZONE_CONFIGURATION_ERROR

Invalid DNS zone configuration.

DNS_ERROR_ZONE_HAS_NO_SOA_RECORD

DNS zone has no start of authority (SOA) record.

DNS_ERROR_ZONE_HAS_NO_NS_RECORDS

DNS zone has no name server (NS) record.

DNS_ERROR_ZONE_LOCKED

DNS zone is locked.

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

ABB Automation

9652

9653

9654

9655

9616

9617

9618

9651

9701

9702

9612

9613

9614

9615

9608

9609

9610

9611

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

DNS_ERROR_ZONE_CREATION_FAILED

DNS zone creation failed.

DNS_ERROR_ZONE_ALREADY_EXISTS

DNS zone already exists.

DNS_ERROR_AUTOZONE_ALREADY_EXISTS

DNS automatic zone already exists.

DNS_ERROR_INVALID_ZONE_TYPE

Invalid DNS zone type.

DNS_ERROR_SECONDARY_REQUIRES_MASTER_IP

Secondary DNS zone requires master IP address.

DNS_ERROR_ZONE_NOT_SECONDARY

DNS zone not secondary.

DNS_ERROR_NEED_SECONDARY_ADDRESSES

Need secondary IP address.

DNS_ERROR_WINS_INIT_FAILED

WINS initialization failed.

DNS_ERROR_NEED_WINS_SERVERS

Need WINS servers.

DNS_ERROR_NBSTAT_INIT_FAILED

NBTSTAT initialization call failed.

DNS_ERROR_SOA_DELETE_INVALID

Invalid delete of start of authority (SOA)

DNS_ERROR_PRIMARY_REQUIRES_DATAFILE

Primary DNS zone requires datafile.

DNS_ERROR_INVALID_DATAFILE_NAME

Invalid datafile name for DNS zone.

DNS_ERROR_DATAFILE_OPEN_FAILURE

Failed to open datafile for DNS zone.

DNS_ERROR_FILE_WRITEBACK_FAILED

Failed to write datafile for DNS zone.

DNS_ERROR_DATAFILE_PARSING

Failure while reading datafile for DNS zone.

DNS_ERROR_RECORD_DOES_NOT_EXIST

DNS record does not exist.

DNS_ERROR_RECORD_FORMAT

DNS record format error.

191

MicroSCADA

3 Status Codes

192

9715

9716

9717

9718

9719

9711

9712

9713

9714

9707

9708

9709

9710

9703

9704

9705

9706

Status Codes

Technical Reference Manual

1MRS751251-MEN

DNS_ERROR_NODE_CREATION_FAILED

Node creation failure in DNS.

DNS_ERROR_UNKNOWN_RECORD_TYPE

Unknown DNS record type.

DNS_ERROR_RECORD_TIMED_OUT

DNS record timed out.

DNS_ERROR_NAME_NOT_IN_ZONE

Name not in DNS zone.

DNS_ERROR_CNAME_LOOP

CNAME loop detected.

DNS_ERROR_NODE_IS_CNAME

Node is a CNAME DNS record.

DNS_ERROR_CNAME_COLLISION

A CNAME record already exists for given name.

DNS_ERROR_RECORD_ONLY_AT_ZONE_ROOT

Record only at DNS zone root.

DNS_ERROR_RECORD_ALREADY_EXISTS

DNS record already exists.

DNS_ERROR_SECONDARY_DATA

Secondary DNS zone data error.

DNS_ERROR_NO_CREATE_CACHE_DATA

Could not create DNS cache data.

DNS_ERROR_NAME_DOES_NOT_EXIST

DNS name does not exist.

DNS_WARNING_PTR_CREATE_FAILED

Could not create pointer (PTR) record.

DNS_WARNING_DOMAIN_UNDELETED

DNS domain was undeleted.

DNS_ERROR_DS_UNAVAILABLE

The Windows NT directory service is unavailable.

DNS_ERROR_DS_ZONE_ALREADY_EXISTS

DNS zone already exists in Windows NT directory service.

DNS_ERROR_NO_BOOTFILE_IF_DS_ZONE

DNS server not creating or reading the boot file for the directory service integrated DNS zone.

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

9751

9752

9753

9801

9851

9852

10004

10022

10024

10035

10036

10037

10009

10013

10014

10038

DNS_INFO_AXFR_COMPLETE

DNS AXFR (zone transfer) complete.

DNS_ERROR_AXFR

DNS zone transfer failed.

DNS_INFO_ADDED_LOCAL_WINS

Added local WINS server.

DNS_STATUS_CONTINUE_NEEDED

Secure update call needs to continue update request.

DNS_ERROR_NO_TCPIP

TCP/IP network protocol not installed.

DNS_ERROR_NO_DNS_SERVERS

No DNS servers configured for local system.

WSAEINTR

A blocking operation was interrupted by a call to

WSACancelBlockingCall.

WSAEBADF

The file handle supplied is not valid.

WSAEACCES

An attempt was made to access a socket in a way forbidden by its access permissions.

WSAEFAULT

The system detected an invalid pointer address in attempting to use a pointer argument in a call.

WSAEINVAL

An invalid argument was supplied.

WSAEMFILE

Too many open sockets.

WSAEWOULDBLOCK

A non-blocking socket operation could not be completed immediately.

WSAEINPROGRESS

A blocking operation is currently executing.

WSAEALREADY

An operation was attempted on a non-blocking socket that already had an operation in progress.

WSAENOTSOCK

An operation was attempted on something that is not a socket.

193

MicroSCADA

3 Status Codes

194

Status Codes

Technical Reference Manual

1MRS751251-MEN

10049

10050

10051

10052

10039

10041

10044

10045

10046

10047

10048

10053

10054

10055

10056

WSAEDESTADDRREQ

A required address was omitted from an operation on a socket.

WSAEPROTOTYPE

A protocol was specified in the socket function call that does not support the semantics of the socket type requested.

WSAESOCKTNOSUPPORT

The support for the specified socket type does not exist in this address family.

WSAEOPNOTSUPP

The attempted operation is not supported for the type of object referenced.

WSAEPFNOSUPPORT

The protocol family has not been configured into the system or no implementation for it exists.

WSAEAFNOSUPPORT

An address incompatible with the requested protocol was used.

WSAEADDRINUSE

Only one usage of each socket address (protocol/network address/port) is normally permitted.

WSAEADDRNOTAVAIL

The requested address is not valid in its context.

WSAENETDOWN

A socket operation encountered a dead network.

WSAENETUNREACH

A socket operation was attempted to an unreachable network.

WSAENETRESET

The connection has been broken due to keep-alive activity detecting a failure while the operation was in progress.

WSAECONNABORTED

An established connection was aborted by the software in your host machine.

WSAECONNRESET

An existing connection was forcibly closed by the remote host.

WSAENOBUFS

An operation on a socket could not be performed because the system lacked sufficient buffer space or because a queue was full.

WSAEISCONN

A connect request was made on an already connected socket.

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

10062

10063

10064

10065

10066

10067

10068

10069

10070

10071

10091

10057

10058

10059

10061

10092

WSAENOTCONN

A request to send or receive data was disallowed because the socket is not connected and (when sending on a datagram socket using a sendto call) no address was supplied.

WSAESHUTDOWN

A request to send or receive data was disallowed because the socket had already been shut down in that direction with a previous shutdown call.

WSAETOOMANYREFS

Too many references to some kernel object.

WSAECONNREFUSED

No connection could be made because the target machine actively refused it.

WSAELOOP

Cannot translate name.

WSAENAMETOOLONG

Name component or name was too long.

WSAEHOSTDOWN

A socket operation failed because the destination host was down.

WSAEHOSTUNREACH

A socket operation was attempted to an unreachable host.

WSAENOTEMPTY

Cannot remove a directory that is not empty.

WSAEPROCLIM

A Windows Sockets implementation may have a limit on the number of applications that may use it simultaneously.

WSAEUSERS

Ran out of quota.

WSAEDQUOT

Ran out of disk quota.

WSAESTALE

File handle reference is no longer available.

WSAEREMOTE

Item is not available locally.

WSASYSNOTREADY

WSAStartup cannot function at this time because the underlying system it uses to provide network services is currently unavailable.

WSAVERNOTSUPPORTED

The Windows Sockets version requested is not supported.

195

MicroSCADA

3 Status Codes

196

Status Codes

Technical Reference Manual

1MRS751251-MEN

10104

10105

10106

10107

10108

10101

10102

10103

10109

10110

10111

10112

11001

11002

11003

11005

WSAEDISCON

Returned by WSARecv or WSARecvFrom to indicate the remote party has initiated a graceful shutdown sequence.

WSAENOMORE

No more results can be returned by WSALookupServiceNext.

WSAECANCELLED

A call to WSALookupServiceEnd was made while this call was still processing. The call has been canceled.

WSAEINVALIDPROCTABLE

The procedure call table is invalid.

WSAEINVALIDPROVIDER

The requested service provider is invalid.

WSAEPROVIDERFAILEDINIT

The requested service provider could not be loaded or initialized.

WSASYSCALLFAILURE

A system call that should never fail has failed.

WSASERVICE_NOT_FOUND

No such service is known. The service cannot be found in the specified name space.

WSATYPE_NOT_FOUND

The specified class was not found.

WSA_E_NO_MORE

No more results can be returned by WSALookupServiceNext.

WSA_E_CANCELLED

A call to WSALookupServiceEnd was made while this call was still processing. The call has been canceled.

WSAEREFUSED

A database query failed because it was actively refused.

WSAHOST_NOT_FOUND

No such host is known.

WSATRY_AGAIN

This is usually a temporary error during hostname resolution and means that the local server did not receive a response from an authoritative server.

WSANO_RECOVERY

A non-recoverable error occurred during a database lookup.

WSA_QOS_RECEIVERS

At least one reserve has arrived.

ABB Automation

1MRS751251-MEN

3.5

3.5.1

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

11006

11007

11008

11009

11010

11011

11012

11013

11014

11015

WSA_QOS_SENDERS

At least one path has arrived.

WSA_QOS_NO_SENDERS

There are no senders.

WSA_QOS_NO_RECEIVERS

There are no receivers.

WSA_QOS_REQUEST_CONFIRMED

Reserve has been confirmed.

WSA_QOS_ADMISSION_FAILURE

Error due to lack of resources.

WSA_QOS_POLICY_FAILURE

Rejected for administrative reasons - bad credentials.

WSA_QOS_BAD_STYLE

Unknown or conflicting style.

WSA_QOS_BAD_OBJECT

Problem with some part of the filterspec or providerspecific buffer in general.

WSA_QOS_TRAFFIC_CTRL_ERROR

Problem with some part of the flowspec.

WSA_QOS_GENERIC_ERROR

General QOS error.

Data Transfer Status Codes

DDE Status Codes

0

16384

16385

16386

16387

16388

16389

16390

16391

16392

16393

16394

DMLERR_NO_ERROR

DMLERR_ADVACKTIMEOUT

DMLERR_BUSY

DMLERR_DATAACKTIMEOUT

DMLERR_DLL_NOT_INITIALIZED

DMLERR_DLL_USAGE

DMLERR_EXECACKTIMEOUT

DMLERR_INVALID_PARAMETER

DMLERR_LOW_MEMORY

DMLERR_MEMORY_ERROR

DMLERR_NOTPROCESSED

DMLERR_NO_CONV_ESTABLISHED

197

MicroSCADA

3 Status Codes

3.5.2

3.5.3

198

Status Codes

Technical Reference Manual

01000

01002

01004

01006

08004

08007

08S01

21S01

21S02

22003

01S02

01S03

01S04

07001

07006

08001

08002

08003

16395

16396

16397

16398

16399

16400

16401

20483

DMLERR_POKEACKTIMEOUT

DMLERR_POSTMSG_FAILED

DMLERR_REENTRANCY

DMLERR_SERVER_DIED

DMLERR_SYS_ERROR

DMLERR_UNADVACKTIMEOUT

DMLERR_UNFOUND_QUEUE_ID

DMLERR_ITEM_TOO_LONG

ODBC Status Codes

1

2

-1

0

99

100

2001

SQL_ERROR

SQL_SUCCESS

SQL_SUCCESS_WITH_INFO

SQL_STILL_EXECUTING

SQL_NEED_DATA

SQL_NO_DATA_FOUND

SQL_UNSUPPORTED_DATATYPE

ODBC Error Codes

General warning

Disconnect error

Data truncated

Privilege not revoked

Option value changed

No rows updated or deleted

More than one row updated or deleted

Wrong number of parameters

Restricted data type attribute violation

Unable to connect to data source

Connection in use

Connection not open

Data source rejected establishment of connection

Connection failure during transaction

Communication link failure

Insert value list does not match column list

Degree of derived table does not match column list

Numeric value out of range

1MRS751251-MEN

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

S1008

S1009

S1010

S1011

S1012

S1090

S1092

S0011

S0012

S0021

S0022

S1000

S1001

S1002

S1003

37000

40001

42000

IM001

IM002

IM003

IM004

IM005

22005

22008

22012

23000

24000

25000

28000

34000

IM006

IM009

IM013

S0001

S0002

Error in assignment

Datetime field overflow

Division by zero

Integrity constraint violation

Invalid cursor state

Invalid transaction state

Invalid authorization specification

Invalid cursor name

Syntax error or access violation

Serialization failure

Syntax error or access violation

Driver does not support this function

Data source name not found and no default driver specified

Specified driver could not be loaded

Driver’s SQLAllocEnv failed

Driver’s SQLAllocConnect failed

Driver’s SQLSetConnect-Option failed

Unable to load translation DLL

Trace file error

Base table or view already exists

Base table not found

Index already exists

Index not found

Column already exists

Column not found

General error

Memory allocation failure

Invalid column number

Program type out of range

Operation cancelled

Invalid argument value

Function sequence error

Operation invalid at this time

Invalid transaction operation code specified

Invalid string or buffer length

Option type out of range

199

MicroSCADA

3 Status Codes

3.6

3.6.1

200

Status Codes

Technical Reference Manual

1MRS751251-MEN

S1109

S1C00

S1T00

Invalid cursor position

Driver not capable

Timeout expire

Status Codes Transmitted by NET to External Devices

Status Codes Transmitted by NET to a PLC

0

10H

20H

30H

31H

40H

50H

OK_STS

NET_NETWORK_LAYER_ERROR_STS

PLC Error word = 81 a) Error in the reception of an ABM command b) ABM transmission error in STA-STA communication

NET_APPLICATION_LAYER_ERROR_STS

PLC Error word = 82

ABM-SCM transformation error, probably memory area definition error

SPLIT_TOTAL_FAIL_STS

PLC Error word = 83

NET failed to forward a message to the original destination (i.e. the DST of the original message) and all secondary destinations or at least one secondary destination (depending on value of SP-attribute)

SPLIT_NEAR_TOTAL_FAIL_STS

INTERNAL Status Code:

NET failed to forward a message to the original destination (i.e. the DST of the original message) but message is forwarded at least to one (not all) secondary destination. Depending on the value of SP-attribute, the Status

Code sent to substation may be:

SP=1 ==> SPLIT_TOTAL_FAIL_

SP=2 ==> OK_STS

SP=3 ==> SPLIT_TOTAL_FAIL_STS

SP=4 ==> SPLIT_ORIG_DEST_FAIL_STS (Not implemented yet)

SP=5 ==> SPLIT_ORIG_DEST_FAIL_STS (Not implemented yet)

SPLIT_ORIG_DEST_FAIL_STS

PLC Error word = 84

NET failed to forward a message to the original destination (i.e. the DST of the original message)

Depending on the value of SP-attribute, message must be forwarded to all secondary destinations or at least t one secondary destination

SPLIT_SEC_DEST_FAIL_STS

PLC Error word = 85

ABB Automation

1MRS751251-MEN

ABB Automation

Status Codes

Technical Reference Manual

MicroSCADA

3 Status Codes

51H

60H

70H

0C0H

0D0H

0E0H

Message must be forwarded to the original destination (i.e. the DST of the original message), but failed to forward it to all secondary destinations or at least one secondary destination (depending on the value of SP-attribute)

SPLIT_NEAR_SEC_DEST_FAIL_STS

INTERNAL Status Code:

Message must be forwarded to the original destination (i.e. the DST of the original message) and at least to one (not all) secondary destination.

Depending on the value of SP-attribute, the Status Code sent to substation may be:

SP=1 ==> SPLIT_SEC_DESTL_FAIL_STS

SP=2 ==> OK_STS

SP=3 ==> OK_STS

SP=4 ==> OK_STS (Not implemented yet)

SP=5 ==> OK_STS (Not implemented yet)

SCM_MESSAGE_FORWARDING_FAILURE

PLC Error word = 86 a) SCM message transmission error b) SCM message routing error c) SCM message handling error in SCS rev 6.2 and earlier

PROC_SCM_MESSAGE_ERROR

PLC Error word = 87

Generated by SCS program (rev 7.0 and later) in certain error situations

INVALID_SCM_MESSAGE_ERROR

PLC Error word = 8C a) The PLC is undefined in NET b) The PLC does not have the station address defined in NET c) The PLC is not in use

INVALID_COMMAND_DESTINATION_STS

PLC Error word = 8D a) The destinaiton device is undefined in NET b) The destination device does not have the station address defined in

NET c) The destination line is undefined in NET d) The destination line is not in use

INVALID_DESTINATION_STATION_TYPE_STS

PLC Error word = 8E

Destination device is not STA, SYS or NET

201

1MRS751251-MEN

Status Codes

Technical Reference Manual

MicroSCADA

Customer Feedback

About This Chapter

This chapter contains information on how to send customer feedback and how to get technical support from the SA Help Desk.

Customer Feedback Database

Customer Feedback is a Lotus Notes database, using which ABB companies can report errors, make improvement proposals and queries related to products manufactured by ABB Substation Automation Oy. Customer Feedback database is connected to the change management system of ABB Substation Automation Oy, which handles all error corrections and improvements made to the products.

Please note that the Customer Feedback database is primarily intended for writing reports about released products. If you are using for example a beta release in a pilot project, this should be clearly stated.

Writing A Customer Feedback Report

When writing a Customer Feedback report, the following general instructions should be taken in consideration:

Write the report in English.

Write only one error report, query or improvement proposal in a Customer

Feedback report.

If you are reporting an error, try to isolate the error as well as possible. Describe the sequence of events and actions that lead to the error. If any error messages or other debug information is provided by the system, please write it down. Include also information of the system, e.g. a system diagram, revision information and configuration data.

If you are making an improvement proposal, try to describe how the improved function should work and avoid providing solutions. Information about the importance of the improvement, e.g. number of projects that require the improvement, helps us to make the decision whether and when the improvement should be implemented.

To make a Customer Feedback report, select Feedback Report from the Create menu.

This opens an empty Customer Feedback document. Fill out the fields listed below. A question mark next to a field provides help for filling out the field.

1

Subject. This should contain a short description of the issue. A more detailed description can be given in the Description of Feedback field below.

2

Type of Feedback: Comment/Improvement, Query or Complaint/Error.

3

Customer Information.

ABB Automation

MicroSCADA

Status Codes

Technical Reference Manual

1MRS751251-MEN

4

Reporting Information. This should contain detailed information of the product the report is about.

5

The person who you want to send the feedback to and whether you want to get a reply from that person.

6

Information related to internal handling of the report (not obligatory).

7

Category.

You can issue the report by clicking the Issue Feedback button. This will send the report to the selected person and change its status to “in progress”.

Actions

When ABB Substation Automation Oy receives a Customer Feedback report, it is analysed by a sales person or a representative of the technical support. The analyser may ask for additional information in order to completed the analysis. After the report has been analysed, one of the following actions is taken:

In case of a clear error, the report is moved to the change management system of

ABB Substation Automation Oy. In this system, the error is analysed in detail and corrected in a future patch release or major release depending on the severity and impact of the error.

In case of an improvement proposal, the report is also moved to the change management system, where it is taken as a requirement to future releases.

In case of a query, an answer is provided.

When Customer Feedback reports are handled in the change management system, the outcome can be one of the following:

No Actions It is decided that the report requires no further action. If, for example, the problem is caused by a configuration error, it belongs to this category.

Will be implemented in patch/current release

Moved to future release

This result means that the correction or new feature will be available in the next official program release.

This result means that the new feature will be available in some new program release in the near future.

SA Help Desk

ABB Substation Automation Oy provides a technical support service called SA Help

Desk to support local engineering centres in their system projects. The purpose of SA

Help Desk is to provide support for urgent issues such as:

Year 2000 issues.

High-priority issues concerning systems at customers’ sites.

ABB Automation

1MRS751251-MEN

Status Codes

Technical Reference Manual

MicroSCADA

For other kind of technical support, please use the Customer Feedback database. SA

Help Desk is available every day from 06:00 to 21:00 Central European Time.

SA Help Desk can be contacted by telephone. The number is:

+358 50 334 1900

ABB Automation

advertisement

Key Features

  • Lists all MicroSCADA status codes
  • Provides explanations of the codes
  • Divides codes into groups
  • Covers base system and NET units
  • Technical reference manual

Related manuals

Frequently Answers and Questions

What is the purpose of the MicroSCADA Status Codes?
Status codes are used to indicate the reliability of data, inform about errors during SCIL program execution, and communicate events in the process communication system or communication units.
How are status codes grouped?
Status codes are grouped into categories: reliability of data, base system status codes, NET status codes, operating system status codes, data transfer status codes, and status codes transmitted by a NET unit to external devices.
What is the OK status code?
The OK status code is 0, indicating that no error has occurred.
What is the difference between almost OK status codes and error codes?