The Levelflex FMP55 is a premium device with a coated multiparameter probe for interface measurement in the oil & gas, chemical and power industries. This device is designed for safe and reliable measurement both for the interface layer and the overall level by a redundant measuring system. The Levelflex FMP55 is factory precalibrated and features a menu-guided operating concept in national languages for intuitive operation and easy integration into control or asset management systems. It also comes with advanced diagnostics and approvals for various hazardous areas.

advertisement

Output. ENDRESS+HAUSER Levelflex FMP55 | Manualzz

Levelflex FMP55

Output signal

Signal on alarm

Linearization

Galvanic isolation

Protocol-specific data

Output

HART

Signal coding

Data transmission rate

Galvanic isolation

FSK ±0.5 mA over currency signal

1200 Baud

Yes

PROFIBUS PA

Signal coding

Data transmission rate

Galvanic isolation

Manchester Bus Powered (MBP)

31,25 KBit/s, voltage mode

Yes

Depending on the interface, failure information is displayed as follows:

• Current output (for HART devices)

– Failsafe mode selectable (in accordance with NAMUR Recommendation NE 43):

Minimum alarm (for 2-wire units): 3.6 mA

Minimum alarm (for 4-wire units): 2.4 mA

Maximum alarm (= factory setting): 22 mA

– Failsafe mode with user-selectable value: 3.59 to 22.5 mA

• Local display

– Status signal (in accordance with NAMUR Recommendation NE 107)

– Plain text display

• Operating tool via digital communication (HART, PROFIBUS PA) or service interface (CDI)

– Status signal (in accordance with NAMUR Recommendation NE 107)

– Plain text display

The linearization function of the device allows the conversion of the measured value into any unit of length or volume. Linearization tables for calculating the volume in cylindrical tanks are pre-programmed. Other tables of up to 32 value pairs can be entered manually or semi-automatically.

All circuits for the outputs are galvanically isolated from each other.

HART

Manufacturer ID

Device type ID

HART specification

Device description files (DTM,

DD)

HART load

17 (0x11)

0x34

6.0

Information and files under:

• www.endress.com

• www.hartcomm.org

Min. 250 W

Endress+Hauser 9

10

HART device variables

Levelflex FMP55

The measured values can be freely assigned to the device variables.

Measured values for PV (primary variable)

• Level linearized

• Distance

• Interface

• Interface distance

• Upper interface thickness

• Electronic temperature

• Measured capacity

• Relative echo amplitude

• Relative interface amplitude

Measured values for SV, TV, FV (second, third and fourth variable)

• Level linearized

• Distance

• Interface linearized

• Interface distance

• Upper interface thickness

• Terminal voltage

• Electronic temperature

• Measured capacity

• Absolute echo amplitude

• Relative echo amplitude

• Absolute interface amplitude

• Relative interface amplitude

• Calculated DC

• Burst mode

• Additional transmitter status

Supported functions

PROFIBUS PA

Manufacturer ID

Ident number

Profile version

GSD file

GSD file version

Output values

17 (0x11)

0x1558

3.02

Information and files under:

• www.endress.com

• www.profibus.org

Analog Input:

• Level linearized

• Distance

• Interface

• Interface distance

• Upper interface thickness

• Terminal voltage

• Electronic temperature

• Measured capacity

• Absolute echo amplitude

• Relative echo amplitude

• Absolute interface amplitude

• Relative interface amplitude

• Calculated DC

Digital Input:

• Extended diagnostic blocks

1)

• Status output PFS Block

Endress+Hauser

advertisement

Key Features

  • Coated multiparameter probe
  • Redundant measuring system
  • Measuring range up to 10m
  • Factory precalibrated
  • Menu-guided operating concept
  • Simple integration
  • Advanced diagnostics
  • ATEX, IEC Ex, CSA, FM approvals

Related manuals

Frequently Answers and Questions

What is the measuring range of the Levelflex FMP55?
The measuring range of the Levelflex FMP55 is up to 10 m (33 ft).
What types of interfaces are available for system integration with the Levelflex FMP55?
The Levelflex FMP55 offers the following interfaces for system integration: HART with 4...20 mA analog and PROFIBUS PA (Profile 3.02).
What are the temperature and pressure ranges of the Levelflex FMP55?
The temperature range of the Levelflex FMP55 is -50 to +200 °C (-58 to +392 °F). The pressure range is -1 to 40 bar (-14.5 to 580 psi).