The Levelflex FMP55 is a premium device with a coated multiparameter probe for interface measurement in the oil & gas, chemical and power industries. This device is designed for safe and reliable measurement both for the interface layer and the overall level by a redundant measuring system. The Levelflex FMP55 is factory precalibrated and features a menu-guided operating concept in national languages for intuitive operation and easy integration into control or asset management systems. It also comes with advanced diagnostics and approvals for various hazardous areas.

advertisement

Operating conditions: Environment. ENDRESS+HAUSER Levelflex FMP55 | Manualzz

Levelflex FMP55

Ambient temperature range

Operating conditions: Environment

Measuring device

Local display

Connection cable (for

"Probe Design" = "Sensor remote")

–40 to +80 °C (–40 to +176 °F)

–20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at temperatures outside the temperature range.

85 °C (185 °F)

Ambient temperature limits

When operating the device in the open with strong sunlight:

• Mount the device in a shady position.

• Avoid direct sunlight, especially in warmer regions.

• Use a weather protection cover (see accessories).

The following diagrams take into account only function requirements. There may be further restrictions

for certified device versions. Please refere to the separate Safety Instructions (® ä 51).

26 Endress+Hauser

Levelflex FMP55

Endress+Hauser

With a temperature (T p

) at the process connection the admissible ambient temperature (T a

) is reduced according to the following diagram (temperature derating):

Temperature derating for FMP55

Ta

[°C] ([°F]) Ta

+80 (+176)

Tp

GT20:

+59 (+138)

GT18:

+56 (+133)

GT19:

+33 (+91)

A:

GT19:

-36 (-33)

GT18/20:

-38 (-36)

-40 (-40)

-50

(-58)

-40

(-40)

[°C] ([°F]) Ta

GT18/20:

+79 (+174)

GT19:

+74 (+165)

C:

+82

(+180)

+79

(+174)

+200

(+392)

Tp

[°C]

([°F])

GT20:

+55 (+131)

GT18:

+52 (+126)

GT19:

+33 (+91)

GT19:

-36 (-33)

GT18:

-37 (-35)

GT20:

-38 (-36)

-40 (-40)

-50

(-58)

-40

(-40)

K:

L:

[°C] ([°F]) Ta

+81 (+178)

90–253 VAC

10.4–48 VDC

+74

(+165)

+200

(+392)

Tp

[°C]

([°F])

GT20:

+58 (+136)

GT18:

+55 (+131)

GT18:

-37 (-35)

GT20:

-38 (-36)

-40 (-40)

-50

(-58)

1

G :

PROFIBUS PA

-40

(-40)

+81

(+178)

+200

(+392)

Tp

[°C]

([°F])

[°C] ([°F]) Ta

+79 (+173)

GT20:

+55 (+130)

GT18:

+52 (+126)

2

G :

PROFIBUS PA

Switch output

GT18:

-37 (-35)

GT20:

-38 (-36)

-40 (-40)

-50

(-58)

-40

(-40)

+79

(+173)

+200

(+392)

Tp

[°C]

([°F])

GT18 = stainless steel housing

GT19 = plastic housing

GT20 = aluminum housing

1)

A = 1 current output

C = 2 current outputs

G

1

, G

2

= PROFIBUS PA

1)

K, L = 4-wire

For PROFIBUS PA the temperature derating depends on the usage of the switch output. (G 1 : switch output not connected; G2: switch output connected).

A0013630

T a

= ambient temperature

T p

= temperature at the process connection

27

advertisement

Key Features

  • Coated multiparameter probe
  • Redundant measuring system
  • Measuring range up to 10m
  • Factory precalibrated
  • Menu-guided operating concept
  • Simple integration
  • Advanced diagnostics
  • ATEX, IEC Ex, CSA, FM approvals

Related manuals

Frequently Answers and Questions

What is the measuring range of the Levelflex FMP55?
The measuring range of the Levelflex FMP55 is up to 10 m (33 ft).
What types of interfaces are available for system integration with the Levelflex FMP55?
The Levelflex FMP55 offers the following interfaces for system integration: HART with 4...20 mA analog and PROFIBUS PA (Profile 3.02).
What are the temperature and pressure ranges of the Levelflex FMP55?
The temperature range of the Levelflex FMP55 is -50 to +200 °C (-58 to +392 °F). The pressure range is -1 to 40 bar (-14.5 to 580 psi).
Download PDF

advertisement

Table of contents