- Home
- Do-It-Yourself tools
- Hand tools
- Measuring & layout tools
- ENDRESS+HAUSER
- Levelflex FMP55
- Datasheet
The Levelflex FMP55 is a premium device with a coated multiparameter probe for interface measurement in the oil & gas, chemical and power industries. This device is designed for safe and reliable measurement both for the interface layer and the overall level by a redundant measuring system. The Levelflex FMP55 is factory precalibrated and features a menu-guided operating concept in national languages for intuitive operation and easy integration into control or asset management systems. It also comes with advanced diagnostics and approvals for various hazardous areas.
advertisement
Levelflex FMP55
Compact device Levelflex
Ordering information
1
2
3
5 6
4
Product structure FMP55
å
13 Design of the Levelflex
1 Electronics housing
2 Process connection (here as an example: flange)
3 Rope probe
4 End-of-probe weight
5 Rod probe
6 Coax probe
This overview does not mark options which are mutually exclusive.
Option with * = in preparation
010 Approval:
AA Non-hazardous area
BA ATEX II 1G Ex ia IIC T6
BB ATEX II 1/2G Ex ia IIC T6
BC ATEX II 1/2G Ex d(ia) IIC T6
BD ATEX II 1/3G Ex ic(ia) IIC T6
BG ATEX II 3G Ex nA IIC T6
BH ATEX II 3G Ex ic IIC T6
B2 ATEX II 1/2G Ex ia IIC T6, 1/2D Ex tD IIIC IP6x
B3 ATEX II 1/2G Ex d(ia) IIC T6, 1/2D Ex tD IIIC IP6x
B4 ATEX II 1/2G Ex ia IIC T6, Ex d(ia) IIC T6
CA CSA General Purpose
C2 CSA C/US IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 Div.2, Ex ia
C3 CSA C/US XP Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 Div.2, Ex d
FB FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia, NI Cl.1 Div.2
FD FM XP Cl.I,II,III Div.1 Gr.A-G, AEx d, NI Cl.1 Div.2
IA IEC Ex Zone 0 Ex ia IIC T6 Ga
IB IEC Ex Zone 0/1 Ex ia IIC T6 Ga/Gb
IC IEC Ex Zone 0/1 Ex d(ia) IIC T6 Ga/Gb
42
A0012399
Endress+Hauser
Levelflex FMP55
Endress+Hauser
010 Approval:
ID IEC Ex Zone 0/2 Ex ic(ia) IIC T6 Ga/Gc
IG IEC Ex Zone 2 Ex nA IIC T6 Gc
IH IEC Ex Zone 2 Ex ic IIC T6 Gc
I2 IEC Ex Zone 0/1 Ex ia IIC T6 Ga/Gb, Zone 20/21 Ex tD IIIC A20/21 IP6x Da/Db
I3 IEC Ex Zone 0/1 Ex d(ia) IIC T6 Ga/Gb, Zone 20/21 Ex tD IIIC A20/21 IP6x Da/Db
NA *NEPSI zone 0 Ex ia IIC T6 Ga
NB *NEPSI zone 0/1 Ex ia IIC T6 Ga/Gb
NC *NEPSI zone 0/1 Ex d(ia) IIC T6 Ga/Gb
NG *NEPSI zone 2 Ex nA II T6 Gc
NH *NEPSI zone 2 Ex ic IIC T6 Gc
N2 *NEPSI zone 0/1 Ex ia IIC T6 Ga/Gb, zone 20/21 Ex tD IIIC A20/21 IP6x Da/Db
N3 *NEPSI zone 0/1 Ex d(ia) IIC T6 Ga/Gb, zone 20/21 Ex tD IIIC A20/21 IP6x Da/Db
8A FM/CSA IS+XP Cl.I,II,III Div.1 Gr.A-G
99 Special version, TSP-no. to be sepc.
020 Power Supply, Output
A 2-wire; 4-20mA HART
C 2-wire; 4-20mA HART, 4-20mA
G 2-wire; PROFIBUS PA; switch output
K 4-wire 90-253VAC; 4-20mA HART
L 4-wire 10,4-48VDC; 4-20mA HART
Y Special version, TSP-no. to be sepc.
030 Display, Operation:
A W/o, via communication
C SD02 4-line, push buttons + data backup function
Y Special version, TSP-no. to be sepc.
040 Housing:
A GT19 dual compartment, Plastics PBT
B GT18 dual compartment, 316L
C GT20 dual compartment, Alu coated
Y Special version, TSP-no. to be sepc.
050 Electrical connection:
A Gland M20, IP66/68 NEMA4X/6P
B Thread M20, IP66/68 NEMA4X/6P
C Thread G1/2, IP66/68 NEMA4X/6P
D Thread NPT1/2, IP66/68 NEMA4X/6P
I Plug M12, IP66/68 NEMA4X/6P
M Plug 7/8", IP66/68 NEMA4X/6P
Y Special version, TSP-no. to be sepc.
060 Probe:
CA ..... mm, rod 16mm PFA>316L
CB ..... inch, rod 0.63in PFA>316L
NA ..... mm, rope 4mm PFA>316
ND ..... inch, rope 1/6" PFA>316
43
44
060 Probe:
UA ..... mm, coax 316L
UB ..... inch, coax 316L
YY Special version, TSP-no. to be sepc.
100 Process connection:
AEK 1-1/2" 150lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
AFK 2" 150lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
AGK 3" 150lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
AHK 4" 150lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
AJK 6" 150lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
AQK 1-1/2" 300lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
ARK 2" 300lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
ASK 3" 300lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
ATK 4" 300lbs, PTFE>316/316L flange ANSI B16.5 (CRN)
CFK DN50 PN10/16, PTFE>316L flange EN1092-1
CGK DN80 PN10/16, PTFE>316L flange EN1092-1
CHK DN100 PN10/16, PTFE>316L flange EN1092-1
CJK DN150 PN10/16, PTFE>316L flange EN1092-1
CQK DN40 PN10-40, PTFE>316L flange EN1092-1
CRK DN50 PN25/40, PTFE>316L flange EN1092-1
CSK DN80 PN25/40, PTFE>316L flange EN1092-1
CTK DN100 PN25/40, PTFE>316L flange EN1092-1
KEK 10K 40, PTFE>316L flange JIS B2220
KFK 10K 50, PTFE>316L flange JIS B2220
KGK 10K 80, PTFE>316L flange JIS B2220
KHK 10K 100, PTFE>316L flange JIS B2220
YYY Special version, TSP-no. to be sepc.
500 Additional Operation Language:
AA English
AB German
AC French
AD Spanish
AE Italian
AF Dutch
AG Portuguese
AH Polish
AI Russian
AL Japanese
AM Korean
AR Czech
550 Calibration:
F4
5-point linearity protocol (® ä 46)
F9 Special version, TSP-no. to be sepc.
Levelflex FMP55
Endress+Hauser
Levelflex FMP55
570 Service: (Multiple options can be selected)
HC PWIS free, PWIS = paint-wetting impairment substances
IJ
Customized parametrization HART (® ä 46)
IK
Customized parametrization PA (® ä 46)
IW W/o Tooling DVD (FieldCare setup)
I9 Special version, TSP-no. to be sepc.
580 Test, Certificate: (Multiple options can be selected)
JA 3.1 Material certificate, wetted matallic parts, EN10204-3.1 inspection certificate
JE Conformity to NACE MR0175, wetted metallic parts
JD 3.1 Material certificate, pressure retaining parts, EN10204-3.1 inspection certificate
JE Conformity to NACE MR0103, wetted metallic parts
KE EPressure test, internal procedure, inspection certificate
KG 3.1 Material certificate+PMI test (XRF), internal procedure, wetted metallic parts, EN10204-3.1 inspection certificate
K9 Special version, TSP-no. to be sepc.
590 Additional Approval: (Multiple options can be selected)
LA SIL
L9 Special version, TSP-no. to be sepc.
600 Probe Design: (Multiple options can be selected)
MB Sensor remote, 3m/9ft cable, detachable+mounting bracket
M9 Special version, TSP-no. to be sepc.
610 Accessory mounted: (Multiple options can be selected)
NC Gas-tight feed through
OE Rod center washer d=37mm/1.45", PFA, interface measurement, pipe diameter DN40/1-1/2" + DN50/2"
O9 Special version, TSP-no. to be sepc.
620 Accessory Enclosed:(Multiple options can be selected)
PB Weather protection cover
R9 Special version, TSP-no. to be sepc.
850 Firmware Version:
75 01.01.zz, HART, DevRev02
77 01.00.zz, PROFIBUS PA, DevRev01
78 01.00.zz, HART, DevRev01
895 Tagging: (Multiple options can be selected)
Z1 Tagging (TAG), see additional spec.
Z2 Bus address, see additional spec.
Endress+Hauser 45
Levelflex FMP55
5 point linearity protocol
The following notes must be taken into account if option F4 ("5 point linearity protocol") has been selected in feature 550 ("Calibration").
The five points of the linearity protocol are evenly distributetd throughout the measuring range (0% to 100%).
In order to define the measuring range, Empty calibration (E) and Full calibration (F) have to be specified
.
The following restrictions have to be taken into account when defining E and F:
R
F
E
Sensor
FMP55
A
100 %
B
0 %
C
A0014673
Minimum distance between reference point
(R) and 100% level
A ³ 250 mm (10 in)
Minimum measuring range
B ³ 400 mm (16 in)
Type of probe
Rod
Coax
Rope
Minimum distance from end of probe to 0% level
C ³ 100 mm (4 in)
C ³ 100 mm (4 in)
C ³ 1000 mm (40 in)
Maximum value for
"empty calibration"
E £ 3.9 m (12.8 ft)
E £ 5.9 m (19.4 ft)
E £ 9 m (29 ft)
• For rod and rope probes the linearity check is performed with the complete device.
• For coax probes the electronics is mounted to a reference rod probe and the linearity check is performed to this configuration.
• In both cases the linearity is checked under reference conditions.
Customized parametrization
If the option IJ "Customized parametrization HART" or IK "Customized parametrization PA" has been selected in feature 570 "Service", customer specific presettings can be selected for the following parameters:
Parameter
Setup ® Distance unit
Setup ® Empty calibration
Communication
• HART
• PA
• HART
• PA
Selection list / range of values
• in
• mm
0 to 10 m (0 to 30 ft)
6)
46
If E and F are not specified, probe dependent default values will be used instead.
Endress+Hauser
advertisement
Key Features
- Coated multiparameter probe
- Redundant measuring system
- Measuring range up to 10m
- Factory precalibrated
- Menu-guided operating concept
- Simple integration
- Advanced diagnostics
- ATEX, IEC Ex, CSA, FM approvals
Related manuals
Frequently Answers and Questions
What is the measuring range of the Levelflex FMP55?
What types of interfaces are available for system integration with the Levelflex FMP55?
What are the temperature and pressure ranges of the Levelflex FMP55?
advertisement
Table of contents
- 2 Table of contents
- 3 Important document information
- 3 Document conventions
- 4 Function and system design
- 4 Measuring principle
- 7 Measuring system
- 8 Input
- 8 Measured variable
- 8 Measuring range
- 8 Blocking distance
- 8 Measuring frequency spectrum
- 9 Output
- 9 Output signal
- 9 Signal on alarm
- 9 Linearization
- 9 Galvanic isolation
- 9 Protocol-specific data
- 11 Auxiliary energy
- 11 Electrical connection
- 16 Supply voltage
- 17 Terminals
- 17 Cable entries
- 17 Cable specification
- 17 Device plug connectors
- 18 Power consumption
- 18 Current consumption
- 18 Power supply failure
- 18 Maximum load
- 19 Potential equalization
- 19 Overvoltage protection
- 20 Performance characteristics
- 20 Reference operating conditions
- 20 Maximum measured error
- 21 Resolution
- 21 Reaction time
- 21 Influence of ambient temperature
- 22 Operating conditions: Installation
- 22 Suitable mounting position
- 22 Applications with restricted mounting space
- 23 Notes on the mechanical load of the probe
- 23 Securing the probe
- 23 Special mounting conditions
- 26 Operating conditions: Environment
- 26 Ambient temperature range
- 26 Ambient temperature limits
- 28 Storage temperature
- 28 Climate class
- 28 Geometric height
- 28 Degree of protection
- 28 Vibration resistance
- 28 Cleaning the probe
- 28 Electromagnetic compatibility (EMC)
- 28 Operating conditions: Process
- 28 Process temperature range
- 28 Process pressure limits
- 29 Materials in contact with process
- 29 Dielectric constant (DC) and conductivity
- 29 Extension of the rope probes through temperature
- 30 Mechanical construction
- 30 Design, dimensions
- 33 Tolerance of probe length
- 33 Weight
- 33 Materials
- 36 Operability
- 36 Operating concept
- 36 Local operation
- 37 Remote operation
- 39 Integration in tank gauging system
- 40 System integration via Fieldgate
- 41 Certificates and approvals
- 41 CE mark
- 41 C-Tick symbol
- 41 Ex approval
- 41 Functional Safety
- 41 AD2000
- 41 Telecommunications
- 41 CRN approval
- 41 Other standards and guidelines
- 42 Ordering information
- 42 Compact device Levelflex
- 42 Product structure FMP55
- 47 Accessories
- 47 Device-specific accessories
- 48 Communication-specific accessories
- 49 Service-specific accessories
- 50 System components
- 50 Documentation
- 50 Standard documentation
- 50 Supplementary documentation
- 51 Certificates
- 51 Registered trademarks
- 52 Patents