CR100 CRM system board User’s Manual
Below you will find brief information for system board CR100 CRM. The CR100 CRM system board is a powerful and versatile motherboard that supports a wide range of features, including Intel® Active Management Technology (AMT), Gigabit LAN, and USB 3.0.
Advertisement
Advertisement
Intel AMT Settings
Enable Intel
®
AMT in the Intel
®
Management
Engine BIOS Extension (MEBX) Screen
1. When the system reboots, the following message will be displayed. Press
<Ctrl-P> as soon as the message is displayed; as this message will be displayed for only a few seconds.
6
American
Megatrends
Version 2. 14. 1219. Copyright (C) 2011 American Megatrends, Inc.
BIOS Date: 02/17/2012 18:13:29 Ver: 1APTJ
Press <Ctrl+P> to enter MEBS setup menu
Press <Del> or <F2> to enter setup
2. You will be prompted for a password. The default password is “admin”. Enter the default password in the space provided under Intel(R) ME Password then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
Main Menu
MEBx Login
> Intel (R) ME General Settings
> Intel (R) AMT Confi guration
MEBx Exit
Intel (R) ME Password
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
133
6
Intel AMT Settings
3. Enter a new password in the space provided under Intel(R) ME New Password then press Enter. The password must include:
• 8-32 characters
• Strong 7-bit ASCII characters excluding : , and ” characters
• At least one digit character (0, 1, ...9)
• At least one 7-bit ASCII non alpha-numeric character, above 0x20, (e.g. !,
$, ;)
• Both lower case and upper case characters
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
Main Menu
MEBx Login
> Intel (R) ME General Settings
> Intel (R) AMT Confi guration
MEBx Exit
Intel (R) ME Password
Intel (R) ME Password
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
134
Intel AMT Settings
4. You will be asked to verify the password. Enter the same new password in the space provided under Verify Password then press Enter.
6
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
Main Menu
MEBx Login
> Intel (R) ME General Settings
> Intel (R) AMT Confi guration
MEBx Exit
Verify Password
Intel (R) ME Password
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
5. Select Intel(R) ME General Settings then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
Main Menu
> Intel (R) ME General Settings
> Intel (R) AMT Confi guration
MEBx Exit
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
135
6
Intel AMT Settings
6. Select Change Intel(R) ME Password then press Enter.
You will be prompted for a password. The default password is “admin”. Enter the default password in the space provided under Intel(R) ME New Password then press Enter.
• 8-32 characters
• Strong 7-bit ASCII characters excluding : , and ” characters
• At least one digit character (0, 1, ...9)
• At least one 7-bit ASCII non alpha-numeric character, above 0x20, (e.g. !,
$, ;)
• Both lower case and upper case characters
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME PLATFORM CONFIGURATION
> Change ME Password
Local FW Updtate <Enabled>
> Power Control
Intel (R) ME New Password
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
136
Intel AMT Settings
7. Select Local FW Update then press Enter. Select Enabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME PLATFORM CONFIGURATION
> Change ME Password
Local FW Updtate <Enabled>
> Power Control
6
Disabled
Enabled
Password Protected
<ENTER> = Complete Entry [ESC]= Discard Changes
8. In the Intel(R) ME Platform Confi guration menu, select Power Control then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME PLATFORM CONFIGURATION
> Change ME Password
Local FW Updtate <Enabled>
> Power Control
Intel (R) ME New Password
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
137
6
Intel AMT Settings
9. In the Intel(R) ME Power Control menu, select Intel(R) ME ON in Host
Sleep States then press Enter. Select an option then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME POWER CONTROL
Intel (R) ME ON in Host Sleep States <Mobile ON in S0>
Idle Timeout 65535
Mobile: ON in S0
Mobile: ON in S0, ME Wake in S3, S4-5 (AC only)
138
<ENTER> = Complete Entry [ESC]= Discard Changes
10. In the Intel(R) ME Power Control menu, select Idle Timeout then press
Enter. Enter the timeout value.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME POWER CONTROL
Intel (R) ME ON in Host Sleep States <Mobile ON in S0>
Idle Timeout 65535
Timeout Value (1-65535)
65535_
<ENTER> = Complete Entry [ESC]= Discard Changes
Intel AMT Settings
11. Select Previous Menu until you return to the Main Menu. Select Intel(R)
AMT Confi guration then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AMT CONFIGURATION
Manageability Feature Selection < Enabled>
> SOL/ IDER/ KVM
> User Consent
Password Policy <Anytime>
> Network Setup
Activate Netwok Access
Unconfi gure Network Access <Full Unprovision>
> Remote Setup And Confi guration
6
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
12. In the Intel(R) AMT Confi guration menu, select Manageability Feature
Selection then press Enter. Select disabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AMT CONFIGURATION
Manageability Feature Selection < Enabled>
> SOL/ IDER/ KVM
> User Consent
Password Policy <Anytime>
> Network Setup
Activate Netwok Access
Disabled
> Remote Setup And Confi guration
<ENTER> = Complete Entry [ESC]= Discard Changes
139
6
Intel AMT Settings
13. In the Intel(R) AMT Confi guration menu, select SOL/IDER/KVM then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
SOL/ IDER/ KVM
Username and password < Enabled>
SOL <Enabled>
IDER <Enabled>
KVM Feature Selection <Enabled>
Legacy Redirection Mode <Disabled>
Menu for FW Redirection Confi guration
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
14. In the SOL/IDER/KVM menu, select Username and Password then press Enter. Select disabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
SOL/ IDER/ KVM
Username and password < Enabled>
SOL <Enabled>
IDER <Enabled>
KVM Feature Selection <Enabled>
Legacy Redirection Mode <Disabled>
Disabled
Enabled
<ENTER> = Complete Entry [ESC]= Discard Changes
140
Intel AMT Settings
15. In the SOL/IDER/KVM menu, select SOL then press Enter. Select disabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
SOL/ IDER/ KVM
Username and password < Enabled>
SOL <Enabled>
IDER <Enabled>
KVM Feature Selection <Enabled>
Legacy Redirection Mode <Disabled>
Disabled
Enabled
6
<ENTER> = Complete Entry [ESC]= Discard Changes
16. In the SOL/IDER/KVM menu, select IDER then press Enter. Select disabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
SOL/ IDER/ KVM
Username and password < Enabled>
SOL <Enabled>
IDER <Enabled>
KVM Feature Selection <Enabled>
Legacy Redirection Mode <Disabled>
Disabled
Enabled
<ENTER> = Complete Entry [ESC]= Discard Changes
141
6
Intel AMT Settings
17. In the SOL/IDER/KVM menu, select KVM then press Enter. Select disabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
SOL/ IDER/ KVM
Username and password < Enabled>
SOL <Enabled>
IDER <Enabled>
KVM Feature Selection <Enabled>
Legacy Redirection Mode <Disabled>
Disabled
Enabled
<ENTER> = Complete Entry [ESC]= Discard Changes
18. In the SOL/IDER/KVM menu, select Legacy Redirection Mode then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
SOL/ IDER/ KVM
Username and password < Enabled>
SOL <Enabled>
IDER <Enabled>
KVM Feature Selection <Enabled>
Legacy Redirection Mode <Disabled>
Menu for FW Redirection Confi guration
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
142
Intel AMT Settings
19. Select Enabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
SOL/ IDER/ KVM
Username and password < Enabled>
SOL <Enabled>
IDER <Enabled>
KVM Feature Selection <Enabled>
Legacy Redirection Mode <Disabled>
Disabled
Enabled
6
<ENTER> = Complete Entry [ESC]= Discard Changes
20. Select Previous Menu until you return to the Intel(R) AMT Confi guration menu. Select User Consent then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
USER CONSENT
User Opt-in < KVM>
Opt-in Confi guration from Remote IT < Enabled>
Confi gure when user consent should be required.
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
143
6
Intel AMT Settings
21. In the User Consent Confi guration menu, select User Opt-in then press
Enter. Select None then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
USER CONSENT
User Opt-in < KVM>
Opt-in Confi guration from Remote IT < Enabled>
NONE
KVM
ALL
144
<ENTER> = Complete Entry [ESC]= Discard Changes
22. In the User Consent Confi guration menu, select Opt-in Confi gurable
from Remote IT then press Enter. Select Disable Remote Control of
KVM Opt-in Policy then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
USER CONSENT
User Opt-in < KVM>
Opt-in Confi guration from Remote IT < Enabled>
Disabled
Enabled
[ENTER] = Access
<ENTER> = Complete Entry [ESC]= Discard Changes
Intel AMT Settings
23. Select Previous Menu until you return to the Intel(R) AMT Confi guration menu. Select Password Policy then press Enter.
You may choose to use a password only during setup and confi guration or to use a password anytime the system is being accessed.
6
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AMT CONFIGURATION
Manageability Feature Selection < Enabled>
> SOL/ IDER/ KVM
> User Consent
Password Policy <Anytime>
> Network Setup
Activate Netwok Access
Anytime
[ENTER] = Select Entry [ESC]= Exit
24. In the Intel(R) AMT Confi guration menu, select Network Setup then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AMT CONFIGURATION
Manageability Feature Selection < Enabled>
> SOL/ IDER/ KVM
> User Consent
Password Policy <Anytime>
> Network Setup
Activate Netwok Access
Unconfi gure Network Access <Full Unprovision>
> Remote Setup And Confi guration
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
145
6
Intel AMT Settings
25. In the Intel(R) Network Setup menu, select Intel(R) ME Network
Name Settings then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME NETWORK SETUP
> Intel (R) ME Network Name Settings
> TCP/ IP Settings
146
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
26. In the Intel(R) ME Network Name Settings menu, select Host Name then press Enter. Enter the computer’s host name then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME NETWORK NAME SETTINGS
Host Name _
Domain Name _
Shared/ Dedicated FQDN <Shared>
Dynamic DNS Update <Disabled>
Computer Host Name
<ENTER> = Complete Entry [ESC]= Discard Changes
Intel AMT Settings
27. Select Domain Name then press Enter. Enter the computer’s domain name then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME NETWORK NAME SETTINGS
Host Name _
Domain Name _
Shared/ Dedicated FQDN <Shared>
Dynamic DNS Update <Disabled>
6
Computer Domain Name
<ENTER> = Complete Entry [ESC]= Discard Changes
28. Select Shared/Dedicated FQDN then press Enter. Select Shared or Dedicated then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME NETWORK NAME SETTINGS
Host Name _
Domain Name _
Shared/ Dedicated FQDN <Shared>
Dynamic DNS Update <Disabled>
Dedicated shared
<ENTER> = Complete Entry [ESC]= Discard Changes
147
6
Intel AMT Settings
29. Select Dynamic DNS Update then press Enter. Select Enabled or Disabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) ME NETWORK NAME SETTINGS
Host Name _
Domain Name _
Shared/ Dedicated FQDN <Shared>
Dynamic DNS Update <Disabled>
Disabled
Enabled
<ENTER> = Complete Entry [ESC]= Discard Changes
30. Select Previous Menu until you return to the Intel(R) ME Network Setup menu. Select TCP/IP Settings then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
TCP/ IP SETTINGS
> Wired LAN IPV4 Confi guration
148
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
Intel AMT Settings
31. In the TCP/IP Settings menu, select Wired LAN IPV4 Confi guration then press Enter.
6
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
WIRED LAN IPV4 CONFIGURATION
DHCP Mode <Enabled>
Disabled
Enabled
<ENTER> = Complete Entry [ESC]= Discard Changes
32. Select Previous Menu until you return to the Intel(R) AMT Confi guration menu. Select Activate Network Access then press Enter. Type Y then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AMT CONFIGURATION
Manageability Feature Selection < Enabled>
> SOL/ IDER/ KVM
> User Consent
Password Policy <Anytime>
> Network Setup
Activate Netwok Access
Unconfi gure Network Access <Full Unprovision>
> Remote Setup And Confi guration and opens the ME netwotk interface
Continue: (Y/N)
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
149
6
Intel AMT Settings
33. In the Intel(R) AMT Confi guration menu, select Unconfi gure Network
Access then press Enter. Type Y then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AMT CONFIGURATION
Manageability Feature Selection < Enabled>
> SOL/ IDER/ KVM
> User Consent
Password Policy <Anytime>
> Network Setup
Activate Netwok Access
Unconfi gure Network Access <Full Unprovision>
> Remote Setup And Confi guration
Full Unprovision
<ENTER> = Complete Entry [ESC]= Discard Changes
34. In the Intel(R) AMT Confi guration menu, select Remote Setup And
Confi guration then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AMT CONFIGURATION
Manageability Feature Selection < Enabled>
> SOL/ IDER/ KVM
> User Consent
Password Policy <Anytime>
> Network Setup
Activate Netwok Access
Unconfi gure Network Access <Full Unprovision>
> Remote Setup And Confi guration
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
150
Intel AMT Settings
35. In the Intel(R) Automated Setup And Confi guration menu, select Cur-
rent Provisioning Mode then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AUTOMATED SETUP AND CONFIGURATION
Current Provisioning Mode
Provisioning Record
Provisioning Server IPV4/IPV6 _
Provisioning Server FQDN _
> RCFG
> TLS PSK
> TLS PKI
Provisioning Mode:PKI
6
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
36. In the Intel(R) Automated Setup And Confi guration menu, select Pro-
visioning Record then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AUTOMATED SETUP AND CONFIGURATION
Current Provisioning Mode
Provisioning Record
Provisioning Server IPV4/IPV6 _
Provisioning Server FQDN _
> RCFG
> TLS PSK
> TLS PKI
Provision Record is not present
[ESC] = Exit
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
151
6
Intel AMT Settings
37. Select Previous Menu until you return to the Intel(R) Automated Setup
And Confi guration menu. Select Provisioning Server IPV4/IPV6 then press Enter. Type server address then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AUTOMATED SETUP AND CONFIGURATION
Current Provisioning Mode
Provisioning Record
Provisioning Server IPV4/IPV6 _
Provisioning Server FQDN _
> RCFG
> TLS PSK
> TLS PKI
Provisioning server address
152
<ENTER> = Complete Entry [ESC]= Discard Changes
38. In the Intel(R) Automated Setup And Confi guration menu, select
Provisioning Server FQDN then press Enter. Type FQDN of provisioning server then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AUTOMATED SETUP AND CONFIGURATION
Current Provisioning Mode
Provisioning Record
Provisioning Server IPV4/IPV6 _
Provisioning Server FQDN _
> RCFG
> TLS PSK
Enter FQDN of provisioning server
> TLS PKI
<ENTER> = Complete Entry [ESC]= Discard Changes
Intel AMT Settings
39. In the Intel(R) Remote Confi guration menu, select Start Confi guration then press Enter. Type Y then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) REMOTE CONFIGURATION
Start Confi guration
6
This will activate Remote Confi guration.
Continue: (Y/N)
[ESC] = Exit
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
40. In the Intel(R) Automated Setup And Confi guration menu, select TLS
PSK then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) TLS PSK CONFIGURATION
Set PID and PPS ** _
Delete PID and PPS **
Enter PID (e.g. ABCD-1234)
<ENTER> = Complete Entry [ESC]= Exit
153
6
Intel AMT Settings
41. In the Intel(R) Remote Confi guration menu, select Set PID and PPS
** then press Enter. Type PID code then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) TLS PSK CONFIGURATION
Set PID and PPS ** _
Delete PID and PPS **
Enter PID (e.g. ABCD-1234)
154
<ENTER> = Complete Entry [ESC]= Exit
42. In the Intel(R) Remote Confi guration menu, select Delete PID and
PPS ** then press Enter. Type Y then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AUTOMATED SETUP AND CONFIGURATION
Set PID and PPS **
Delete PID and PPS **
CAUTION:
This will delete the PID and PPS entries.
Continue: (Y/N)
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
Intel AMT Settings
43. Select Previous Menu until you return to the Intel(R) Automated Setup
And Confi guration menu. Select TLS PKI then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) AUTOMATED SETUP AND CONFIGURATION
Current Provisioning Mode
Provisioning Record
Provisioning Server IPV4/IPV6 _
Provisioning Server FQDN _
> RCFG
> TLS PSK
> TLS PKI
6
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
44. In the Intel(R) Remote Confi guration menu, select Remote Confi gura-
tion ** then press Enter. Select Disabled then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) REMOTE CONFIGURATION
Remote Confi guration ** <Enabled>
PKI DNS Suffi x _
> Manage Hashes
Disabled
Enabled
<ENTER> = Complete Entry [ESC]= Discard Changes
155
6
Intel AMT Settings
45. In the Intel(R) Remote Confi guration menu, select PKI DNS Suffi x then press Enter. Type PKI DNS Suffi x then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) REMOTE CONFIGURATION
Remote Confi guration ** <Enabled>
PKI DNS Suffi x _
> Manage Hashes
Enter PKI DNS Suffi x
156
<ENTER> = Complete Entry [ESC]= Discard Changes
46. In the Intel(R) Remote Confi guration menu, select Manage Hashes then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
INTEL (R) REMOTE CONFIGURATION
Hash Name Active Default Algorithm
VeriSign Class 3 Active: [*] Default: [*] SHA1
VeriSign Class 3 Active: [*] Default: [*] SHA1
Go Daddy Class 2 Active: [*] Default: [*] SHA1
Comodo AAA CA Active: [*] Default: [*] SHA1
Starfi eld Class 2 Active: [*] Default: [*] SHA1
VeriSign Class 3 Active: [*] Default: [*] SHA1
VeriSign Class 3 Active: [*] Default: [*] SHA1
VeriSign Class 3 Active: [*] Default: [*] SHA1
GTE CyberTrust G1 Active: [*] Default: [*] SHA1
Baltimore Cyber Tr Active: [*] Default: [*] SHA1
Cyber Trust Global Active: [*] Default: [*] SHA1
Verizon Global Ro Active: [*] Default: [*] SHA1
Entrust. net CA (2 Active: [*] Default: [*] SHA1
[Ins]= Add New ash [Delete] = Delete Hash [+] = Activate Hash
[
] =Move highlight [ENTER] = View Hash [Esc]= Exit
Intel AMT Settings
47. Select Previous Menu until you return to the Main Menu. Select Exit then press Enter. Type Y then press Enter.
Intel(R) Management Engine BIOS Extension v8.0.0.0057/Intel(R) ME v8.0.1.1399
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
Main Menu
> Intel (R) ME General Settings
> Intel (R) AMT Confi guration
MEBx Exit
6
Are you sure you want to exit? (Y/N)
Exit
[
] = Move highlight [ENTER] = Select Entry [ESC]= Exit
157
A
NLITE and AHCI Installation Guide
Appendix A - NLITE and AHCI Installation Guide
nLite
nLite is an application program that allows you to customize your XP installation disc by integrating the RAID/AHCI drivers into the disc. By using nLite, the F6 function key usually required during installation is no longer needed.
Note:
The installation steps below are based on nLite version 1.4.9. Installation procedures may slightly vary if you’re using another version of the program.
1. Download the program from nLite’s offi cal website.
http://www.nliteos.com/download.html
2. Install nLite.
Important:
Due to it’s coding with Visual.Net, you may need to fi rst install .NET
Framework prior to installing nLite.
3. Download relevant RAID/AHCI driver fi les from Intel’s website. The drivers you choose will depend on the operating system and chipset used by your computer.
should include iaahci.cat, iaAHCI.inf, iastor.cat, iaStor.
inf, IaStor.sys, license.txt and TXTSETUP.OEM.
158
4. Insert the XP installation disc into an optical drive.
5. Launch nLite. The Welcome screen will appear. Click
Next.
NLITE and AHCI Installation Guide
A
6. Click Next to temporarily save the Windows installation fi les to the designated default folder.
If you want to save them in another folder, click
Browse, select the folder and then click Next.
159
A
NLITE and AHCI Installation Guide
7. Click Next.
8. In the Task Selection dialog box, click Drivers and
Bootable ISO. Click Next.
160
lect Multiple driver folder to select the drivers you will integrate. Click Next.
NLITE and AHCI Installation Guide
A
10. Select only the drivers appropriate for the Windows version that you are using and then click OK.
Integrating 64-bit drivers into 32-bit Windows or vice versa will cause fi le load errors and failed installation.
161
A
NLITE and AHCI Installation Guide
11. If you are uncertain of the southbridge chip used on your motherboard, select all RAID/AHCI controllers and then click
OK.
12. Click Next.
162
13. The program is currently integrating the drivers and applying changes to the installation.
NLITE and AHCI Installation Guide
A
14. When the program is fi nished applying the changes, click Next.
163
A
NLITE and AHCI Installation Guide
15. To create an image, select the Create Image mode under the General section and then click
Next.
16. Or you can choose to burn it directly to a disc by selecting the Direct
Burn mode under the
General section.
Select the optical device and all other necessary settings and then click
Next.
164
17. You have finished customizing the Windows
XP installation disc. Click
Finish.
Enter the BIOS utility to confi gure the SATA controller to RAID/AHCI. You can now install Windows
XP.
NLITE and AHCI Installation Guide
A
165
A
NLITE and AHCI Installation Guide
AHCI
The installation steps below will guide you in confi guring your SATA drive to AHCI mode.
1. Enter the BIOS utility and confi gure the SATA controller to IDE mode.
2. Install Windows XP but do not press F6.
3. Download relevant RAID/AHCI driver fi les supported by the motherboard chipset from Intel’s website. driver fi les to C:\AHCI.
4. Open Device Manager and right click on one of the
Intel Serial ATA Storage
Controllers, then select
Update Driver.
If the controller you selected did not work, try selecting another one.
166
5. In the Hardware Update
Wizard dialog box, select
“No, not this time” then click Next.
NLITE and AHCI Installation Guide
A
6. Select “Install from a list
or specifi c location (Ad-
vanced)” and then click
Next.
7. Select “Don’t search. I
will choose the driver
to install” and then click
Next.
167
A
NLITE and AHCI Installation Guide
8. Click “Have Disk”.
9. Select C:\AHCI\iaAHCI.inf and then click Open.
10. Select the appropriate
AHCI Controller of your hardware device and then click Next.
168
11. A warning message appeared because the selected SATA controller did not match your hardware device.
Ignore the warning and click Yes to proceed.
12. Click Finish.
NLITE and AHCI Installation Guide
A
13. The system’s settings have been changed. Windows XP requires that you restart the computer.
Click Yes.
14. Enter the BIOS utility and modify the SATA controller from IDE to AHCI. By doing so, Windows will work normally with the
SATA controller that is in
AHCI mode.
169
A
Watchdog Timer
Appendix B - Watchdog Sample Code
;Software programming example:
;---------------------------------------------
;(1) Enter Super IO Confi guration mode
;---------------------------------------------
MOV DX,2EH
MOV AL,87H
OUT DX,AL
OUT DX,AL
;-------------------------------------------------------------------------------------------
;(2) Confi guration Logical Device 7, register CRF5/CRF6 (WDT Control /WDT timer)
;-------------------------------------------------------------------------------------------
MOV DX,2EH
MOV AL,07H
OUT DX,AL
;Ready to Program Logical Device
MOV DX,2FH
MOV AL,07H
OUT DX,AL
;Select Logical Device 7
MOV DX,2EH
MOV AL, F6H
OUT DX,AL
MOV DX,2FH
MOV AL,10H
OUT DX,AL
MOV DX,2EH
MOV AL, F5H
OUT DX,AL
MOV DX,2FH
MOV AL,61H
OUT DX,AL
;Select watchdog timer register
;Set watchdog timer value
;Select watchdog Control Register
;Set Watchdog Control Value
;----------------------------------------------------------------
;(1) Exit extended function mode
;----------------------------------------------------------------
MOV DX,2EH
MOV AL,AAH
OUT DX,AL
170
System Error Message
Appendix C - System Error Message
When the BIOS encounters an error that requires the user to correct something, either a beep code will sound or a message will be displayed in a box in the middle of the screen and the message, PRESS F1 TO CONTINUE, CTRL-ALT-ESC or
DEL TO ENTER SETUP, will be shown in the information box at the bottom. Enter
Setup to correct the error.
Error Messages
One or more of the following messages may be displayed if the BIOS detects an error during the POST. This list indicates the error messages for all Awards BIO-
Ses:
CMOS BATTERY HAS FAILED
The CMOS battery is no longer functional. It should be replaced.
Important
Danger of explosion if battery incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the battery manufacturer’s instructions.
CMOS CHECKSUM ERROR
Checksum of CMOS is incorrect. This can indicate that CMOS has become corrupt. This error may have been caused by a weak battery. Check the battery and replace if necessary.
DISPLAY SWITCH IS SET INCORRECTLY
The display switch on the motherboard can be set to either monochrome or color.
This indicates the switch is set to a different setting than indicated in Setup.
Determine which setting is correct, either turn off the system and change the jumper or enter Setup and change the VIDEO selection.
FLOPPY DISK(S) fail (80)
Unable to reset fl oppy subsystem.
FLOPPY DISK(S) fail (40)
Floppy type mismatch.
Hard Disk(s) fail (80)
HDD reset failed.
Hard Disk(s) fail (40)
HDD controller diagnostics failed.
C
171
C
System Error Message
Hard Disk(s) fail (20)
HDD initialization error.
Hard Disk(s) fail (10)
Unable to recalibrate fi xed disk.
Hard Disk(s) fail (08)
Sector Verify failed.
Keyboard is locked out - Unlock the key
The BIOS detects that the keyboard is locked. Keyboard controller is pulled low.
Keyboard error or no keyboard present
Cannot initialize the keyboard. Make sure the keyboard is attached correctly and no keys are being pressed during the boot.
Manufacturing POST loop
System will repeat POST procedure infi nitely while the keyboard controller is pull low. This is also used for the M/B burn in test at the factory.
BIOS ROM checksum error - System halted
The checksum of ROM address F0000H-FFFFFH is bad.
Memory test fail
The BIOS reports memory test fail if the memory has error(s).
172
Troubleshooting
D
Appendix D - Troubleshooting
Troubleshooting Checklist
This chapter of the manual is designed to help you with problems that you may encounter with your personal computer. To effi ciently troubleshoot your system, treat each problem individually. This is to ensure an accurate diagnosis of the problem in case a problem has multiple causes.
Some of the most common things to check when you encounter problems while using your system are listed below.
1. The power switch of each peripheral device is turned on.
2. All cables and power cords are tightly connected.
3. The electrical outlet to which your peripheral devices are connected is working. Test the outlet by plugging in a lamp or other electrical device.
4. The monitor is turned on.
5. The display’s brightness and contrast controls are adjusted properly.
6. All add-in boards in the expansion slots are seated securely.
7. Any add-in board you have installed is designed for your system and is set up correctly.
Monitor/Display
If the display screen remains dark after the system is turned on:
1. Make sure that the monitor’s power switch is on.
2. Check that one end of the monitor’s power cord is properly attached to the monitor and the other end is plugged into a working AC outlet. If necessary, try another outlet.
3. Check that the video input cable is properly attached to the monitor and the system’s display adapter.
4. Adjust the brightness of the display by turning the monitor’s brightness control knob.
173
D
Troubleshooting
The picture seems to be constantly moving.
1. The monitor has lost its vertical sync. Adjust the monitor’s vertical sync.
2. Move away any objects, such as another monitor or fan, that may be creating a magnetic fi eld around the display.
3. Make sure your video card’s output frequencies are supported by this monitor.
The screen seems to be constantly wavering.
1. If the monitor is close to another monitor, the adjacent monitor may need to be turned off. Fluorescent lights adjacent to the monitor may also cause screen wavering.
Power Supply
When the computer is turned on, nothing happens.
1. Check that one end of the AC power cord is plugged into a live outlet and the other end properly plugged into the back of the system.
2. Make sure that the voltage selection switch on the back panel is set for the correct type of voltage you are using.
3. The power cord may have a “short” or “open”. Inspect the cord and install a new one if necessary.
Floppy Drive
The computer cannot access the floppy drive.
1. The fl oppy diskette may not be formatted. Format the diskette and try again.
2. The diskette may be write-protected. Use a diskette that is not write-protected.
3. You may be writing to the wrong drive. Check the path statement to make sure you are writing to the targeted drive.
4. There is not enough space left on the diskette. Use another diskette with adequate storage space.
174
Troubleshooting
Hard Drive
Hard disk failure.
1. Make sure the correct drive type for the hard disk drive has been entered in the BIOS.
2. If the system is confi gured with two hard drives, make sure the bootable
(fi rst) hard drive is confi gured as Master and the second hard drive is confi gured as Slave. The master hard drive must have an active/bootable partition.
Excessively long formatting period.
If your hard drive takes an excessively long period of time to format, it is likely a cable connection problem. However, if your hard drive has a large capacity, it will take a longer time to format.
Serial Port
The serial device (modem, printer) doesn’t output anything or is outputting garbled characters.
1. Make sure that the serial device’s power is turned on and that the device is on-line.
2. Verify that the device is plugged into the correct serial port on the rear of the computer.
3. Verify that the attached serial device works by attaching it to a serial port that is working and confi gured correctly. If the serial device does not work, either the cable or the serial device has a problem. If the serial device works, the problem may be due to the onboard I/O or the address setting.
4. Make sure the COM settings and I/O address are confi gured correctly.
Keyboard
Nothing happens when a key on the keyboard was pressed.
1. Make sure the keyboard is properly connected.
2. Make sure there are no objects resting on the keyboard and that no keys are pressed during the booting process.
D
175
D
Troubleshooting
System Board
1. Make sure the add-in card is seated securely in the expansion slot. If the add-in card is loose, power off the system, re-install the card and power up the system.
2. Check the jumper settings to ensure that the jumpers are properly set.
3. Verify that all memory modules are seated securely into the memory sockets.
4. Make sure the memory modules are in the correct locations.
5. If the board fails to function, place the board on a fl at surface and seat all socketed components. Gently press each component into the socket.
6. If you made changes to the BIOS settings, re-enter setup and load the BIOS defaults.
176
Download
Advertisement
Key features
Supports 3rd Gen Intel® Core™ processors
Supports Intel® HD Graphics 4000
Supports Intel® AMT
Dual channel memory interface
Supports up to 16GB system memory
Frequently asked questions
This motherboard supports 3rd generation Intel® CoreTM processors: Intel® Core™ i7-3610QE, Intel® Core™ i5-3610ME, Intel® Core™ i3-3120ME, and 2nd generation Intel® CoreTM processors: Intel® Core™ i7-2710QE, Intel® Core™ i5-2510E, Intel® Core™ i3-2330E, Intel® Celeron® B810.
The maximum system memory supported is 16GB.
This system board features HDMI, 2 DVI-I (1 supports DVI-D signal only), and LVDS ports.