Air Handler Nomenclature. Amana AVPTC

Add to My manuals
18 Pages

Amana AVPTC is an air handler with a built-in thermal expansion valve for cooling and heat pump applications. It features a variable-speed ECM blower motor and integrated communicating ComfortBridge™ Technology. Commissioning and diagnostics are possible via on-board Bluetooth with the CoolCloud phone and tablet application.

advertisement

Air Handler Nomenclature. Amana AVPTC | Manualzz

Nomenclature

Brand

A Single-Piece Air Handler

A

1

Unit Application

R Multi Position PSC Motor

S Multi Position EEM Motor

V Multi Position Variable-Speed

Motor - Communicating

Cabinet Finish

U Unpainted

P Painted

Expansion Device

F Flowrater

T Expansion Device

V Inverter Tuned Expansion Valve

V

2

P

3

T

4

C

5

25

6,7

Communications

C = ComfortBridge

TM

Compatible

B

8

1

9

4

10

BA

11,12

Engineering*

Major/Minor Revisions

( *Not used for inventory management)

Refrigerant Charge

4 = R-410A

Electrical

1 208/230V, 1 Phase, 60 Hz

25 = 2 Tons

29 = 2½ Tons

31 = 2½ Tons

33 = 2 Tons

Cabinet Width

B = 17½"

C = 21"

D = 24½"

Nominal Capacity @ 13 SEER

35 = 3 Tons 49 = 4 Tons

37 = 2½ - 3½ Tons 59 = 4-5 Tons

39 = 3 Tons 61 = 5 Tons

2

HKS X

1 2

03

3

X

4

A

5

AA

6,7

Unit  Type

HKS Heat  Kit  for  

Air  Handlers

Circuit  Breaker

X No  circuit  breaker

C Circuit  Breaker

Heating  Capacity  @  240  Volts

03 3.0  kW 15 14.4  kW

05

06

08

4.5  kW

6.0  kW

8.0  kW

10 9.6  kW

19 19.2  kW  wth  150F  limit

20 19.2  kW  with  170F  limit

25 25.0  kW

A      Single  Phase  208  V

B      Single  Phase  240  V

C      Single  Phase  208/240  V

D      Three  Phase  208  V

H Special case 208 V *

Revisions

Engineering  Revisions

E      Three  Phase  240  V

Phase

F      Three  Phase  208/240  V

G      Three  Phase  460  V

Cabinet  Size  (MAX)

C      C  Cabinet

D      D  Cabinet

X      All  Cabinet  Sizes www.amana-hac.com

*Refer S&R Plate

SS-AAVPTC

Product Specifications

AVPTC

25B14B*

AVPTC

29B14B*

AVPTC

31C14B*

AVPTC

33C14B*

AVPTC

35B14B*

AVPTC

37B14B*

AVPTC

37C14B*

AVPTC

37D14B*

Nominal Ratings

Cooling (BTU/h)

CFM (High range)

Blower

Diameter

Width

Coil Drain Connection FPT

24,000 30,000 30,000 24,000 28,000 36,000 36,000 36,000

1085/650 1085/610 1315/870 1090/685 1020/685 1085/610 1315/870 1375/865

9½"

6"

¾"

9½"

6"

¾"

10⅝"

8"

¾"

10⅝"

8"

¾"

9½"

6"

¾"

9½"

6"

¾"

10⅝"

8"

¾"

10⅝"

10⅝"

¾"

Service Valve

Liquid

Suction

Electrical Data

⅜"

¾"

⅜"

⅞"

⅜"

⅞"

⅜"

⅞"

⅜"

¾"

⅜"

⅞"

⅜"

⅞"

Voltage

Min Circuit Ampacity

208/240

4.9/4.9

Max. Overcurrent Device (amps) 15/15

208/240

6.5/6.5

15/15

208/240

6.5/6.5

15/15

208/240

4.9/4.9

15/15

208/240

4.9/4.9

15/15

208/240

6.5/6.5

15/15

208/240

6.5/6.5

15/15

208/240

6.5/6.5

15/15

Minimum VAC

Maximum VAC

Blower Motor

FLA

HP

Ship Weight (lbs)

197

253

3.9

½

116

197

253

5.2

¾

129

197

253

5.2

¾

144

197

253

3.9

½

118

197

253

3.9

½

116

197

253

5.2

¾

129 144

Note: Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed.

Refer to unit nameplate and/or Heat Kit Data for specification with approved accessory heaters installed

197

253

5.2

¾

⅜"

⅞"

197

253

5.2

¾

155

AVPTC

39C14B*

AVPTC

49C14B*

AVPTC

49D14B*

AVPTC

59C14B*

AVPTC

59D14B*

AVPTC

61D14B*

Nominal Ratings

Cooling (BTU/h)

CFM (High range)

Blower

Diameter

Width

Coil Drain Connection FPT

36,000

1315/965

10⅝"

8"

¾"

48,000 42,000 48,000 48,000 60,000

1420/1040 1530/1195 1595/875 1990/1445 2025/1630

10⅝"

8"

¾"

10⅝"

10⅝"

¾"

10⅝"

8"

¾"

11¹⁵⁄₁₆"

10⅝"

¾"

11¹⁵⁄₁₆"

10⅝"

¾"

Service Valve

Liquid

Suction

Electrical Data

Voltage

Min Circuit Ampacity

208/240

6.5/6.5

Max. Overcurrent Device (amps) 15/15

Minimum VAC

Maximum VAC

Blower Motor

FLA

HP

⅜"

⅞"

197

253

5.2

¾

⅜"

⅞"

208/240

6.5/6.5

15/15

197

253

5.2

¾

⅜"

⅞"

208/240

6.5/6.5

15/15

197

253

5.2

¾

⅜"

⅞"

208/240

8.6/8.6

15/15

197

253

6.9

1

⅜"

⅞"

208/240

8.6/8.6

15/15

197

253

6.9

1

⅜"

⅞"

208/240

8.6/8.6

15/15

197

253

6.9

1

Ship Weight (lbs)

118 125 167 144 155 167

Note: Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed.

Refer to unit nameplate and/or Heat Kit Data for specification with approved accessory heaters installed

SS-AAVPTC www.amana-hac.com