Wiring Diagram. Amana AVPTC

Add to My manuals
18 Pages

Amana AVPTC is an air handler with a built-in thermal expansion valve for cooling and heat pump applications. It features a variable-speed ECM blower motor and integrated communicating ComfortBridge™ Technology. Commissioning and diagnostics are possible via on-board Bluetooth with the CoolCloud phone and tablet application.

advertisement

Wiring Diagram. Amana AVPTC | Manualzz

Wiring Diagram – Air Handler

(SEE NOTE 4)

GROUND LUG

9

8 7

TO

HEATER KIT

208/230 VAC

L2 L1

RD BK

6 5 4 3 2 1

PL1

PL2

(SEE NOTE 6)

ECM MOTOR

RD BK

BK RD

BK

RD

208

VAC

230

VAC

BK

RD

208

VAC

230

VAC

BL

24VAC

RD

TR1

(SEE NOTE 1)

PU

24VAC

YL

TR2

(SEE NOTE 1)

FAN

MOTOR

WH

BR

BL

INSTALLING

AUX ALARM

(ALARM)

(SEE NOTE 7)

HEATER KIT

OUTPUT

~~

~~

AUX

OUT

AUX

IN

1 2

(EAC-OUT)

RELAY IN

(EAC-IN)

3 4 5 6 7 8 9

GR

AUX ALARM

(ALARM)

AUX

IN

AUX

OUT

J19

EAC-OUT

TB6

TH1

TB1

F1U

TH2

TB3

COM

TB7

TR2

TB4

TR1

TB2

10 11 12

PL3

PL4

RD

BK

THERMOSTAT

GY PU WH GR BL RD

OUTDOOR UNIT

(SEE NOTE 13)

BL RD GY BK

J1

DH/Y2

Y W G C R

LEGACY INPUT

C R 2 1

J2

CT COMM

J3

AC DA

J11U J14

F2U

J4

K1R

K2R

SEG3

SEG2

GND

NC

J6

SEG1

(SEE NOTE 11)

J7

J13

FLASH WRITER

(SEE NOTE 10)

PB3

J12 J15

PB2

PB1

J20

J8

MPU

J9

J5

LED

(SEE NOTE 12)

U10

J18

RD BK

GY BL

INDOOR UNIT

PCB

TS

TC

THERMISTOR

(HEAT EXCHANGER 1,2)

INTEGRATION TYPE

R 2 1 C

DATA AC

RAT

NOTES:

1. PLACE RED WIRES ON 208 V TERMINAL OF 2 TRANSFORMERS (TR1/TR2)

FOR 208 VAC OPERATION.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED

WHEN SERVICING.

3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST

BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER

CONDUCTORS ONLY.

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C

AND LOCAL CODES.

6. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.

7. REMOVE JUMPER TAB AND PUT AUX ALARM SWITCH WHEN

INSTALLING AUX ALARM SWITCH.

9. USE N.E.C CLASS 2 WIRE.

10. SEE MANUAL FOR PUSH BUTTON OPERATION.

11. SEE MANUAL FOR 7-SEGMENT DISPLAY DIAGNOSTIC CODES AND

MENU CODES

12. SEE MANUAL FOR LED FUNCTIONALITY.

13. R AND C TERMINALS (USED FOR 24VAC OUTDOOR CONTROL

VOLTAGE) ARE OPTIONAL FOR 2 STAGE COMMUNICATING AIR

CONDITIONERS. R AND C TERMINALS ARE NOT TO BE USED FOR 2

STAGE COMMUNICATING HEAT PUMP APPLICATIONS.

FOR COMMUNICATING HEAT PUMPS OR IF ONLY TWO THERMOSTAT

WIRES ARE AVAILABLE, A SEPARATE TRANSFORMER MUST BE

INSTALLED IN THE OUTDOOR UNIT FOR CONTROL BOARD POWER.

1 AND 2 WIRES ARE REQUIRED FOR ALL APPLICATIONS. SEE

INSTALLATION MANUAL FOR FULL SYSTEM WIRING EXAMPLES.

SAT

(SUPPLY AIR

TEMPERATURE)

INTEGRATED CONTROL:

LOW VOLTAGE

LOW VOLTAGE FIELD

HIGH VOLTAGE

HIGH VOLTAGE FIELD

JUNCTION

TERMINAL

INTERNAL TO

RESISTOR

OVERCURRENT

PROT. DEVICE

PLUG CONNECTION

EQUIPMENT GND

FIELD GROUND

DISCONNECT

COLOR CODES:

BL - BLUE

RD - RED

YL - YELLOW

OR - ORANGE

BK - BLACK

GY - GREY

BR - BROWN

GR - GREEN

PU - PURPLE

WH - WHITE

L1

GRND

COMPONENT CODES:

PL1, PL2

TL

TR

F1U, F2U

PL3, PL4

POWER/HEATER

CONNECTOR

THERMAL LIMIT

TRANSFORMER

FUSE LINK

TRANSFORMER

CONNECTOR

L2

Y

TO

MICRO

DH/Y2

C

L1

R

FUSE 3 A

W

G

TH2

W1 (1)

W2 (2)

CAS (1)

CAS (2)

INDOOR

AIR

CIRCULATOR

BLWR

208/230 VAC

40 VA

TRANSFORMER

24 VAC

HEAT 1 COIL/R1

HEAT 2 COIL/ R2

CONDENSATE AUX SWITCH

+VDC (1)

RX (2)

TX (3)

GRND (4)

TR2

COM

INTEGRATED CONTROL MODULE

GRND

L2

INDOOR

AIR

CIRCULATOR

BLWR

GRND

0140A00613-B

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Warning

High Voltage:

Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

16 www.amana-hac.com

SS-AAVPTC

Wiring Diagram – Three-Phase Heater Kit

NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER

SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE.

AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW.

NO MARK INDICATES NO HEAT KIT INSTALLED.

PC

1

L1

BK

FL

HTR3 TL

BK

RD

2

L2

L1

BK

TB

BK

L2

RD

RD

BK

FL

HTR2

TL

PU

3

PU

BL

RD

L3

BK

L2

BK

L1

BK

GND

L1

CC

BL

L2

R

L3

BK

BK

T1

T2

T3

BK

BK

BK

BK

BK

BK

BK

BK

FL HTR1 TL

BL

BK

BK

BK

BK

BK

M1

PU

M2

RD

RS

WH

M3

M4

BL

BL

WH

WH

5

6

7

8

9

4

WH

BR

GR

PK

BL

CIRCUIT 1

1 PH 208-240V

1

2

3

TR

4

5

BL

RD

GR

RD

XFMR-C

C

EBTDR

SPEEDUP

K1

K1

M1

NO

COM

NC

RD

PU

BR

WH

BR

CIRCUIT 2

3 PH. 208-240V

WH

WH

SR

RC

BR

EM

PU

BK

L1

PU

NOTE:-

THIS LABEL MUST BE

ATTACHED ON THE

AIRHANDLER IN A PROMINENT

LOCATION

L1

AR POWER SUPPLY

(CIRCUIT 1)

208/240 VOLTS

RC

PK

RD

EM

TR

1 2 3

4

24 VOLT

5

LOW

M1

HIGH

NC NO

EBTDR

COM

BL

C

GR

EBTDR

GR

L2

BR W

W2 W1

3

4

5

6

PC

1

2

7

8

9

T1

L1

FL

FL

HKR POWER SUPPLY

(CIRCUIT 2)

L2

HTR3 TL

T2

FL HTR2 TL

HTR1

M2 M1

CC

TL

M4 M3

RS

HEATER CONTROL

L3

T3

COMPONENT CODE

TL

TR

TB

CC

HTR

EM

EBTDR

RS

RC

HEAT ELEMENT

EVAPORATOR MOTOR

ELEC. BLOWER TIME DELAY RELAY

RELAY/SEQUENCER

RUN CAPACITOR

THERMAL LIMIT

TRANSFORMER

TERMINAL BLOCK

CONTACTOR

PC

SR

FL

9-PIN CONNECTOR

STRAIN RELIEF

FUSE LINK

CB CIRCUIT BREAKER

WIRING CODE

HIGH VOLTAGE

LOW VOLTAGE

COLOR CODE

BK BLACK

BL BLUE

BR BROWN

GR GREEN

OR ORANGE

PK PINK

PU PURPLE

RD RED

WH WHITE

YL YELLOW

0140M00273-A

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Warning

High Voltage:

Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

SS-AAVPTC www.amana-hac.com