APC AFX Series
Manuals and User Guides for APC AFX Series. We found 3 manuals for free downloads: Datasheet, Specification
APC AFX Series Specifications
Brand: APC Category: Dehumidifiers Size: 201 KB Pages: 23
Languages: English
Table of contents
- 7 Installation
- 13 Charging the System
- 11 Piping Connections
- 14 Control/Safety Adjustments
- 14 Belt Tension
- 14 Motor Pulley
- 14 Motor Adjustment
- 15 Overload Relay
- 15 Firestat
- 15 Flow Switch
- 17 Troubleshooting
APC AFX Series Specifications
Brand: APC Category: Dehumidifiers Size: 780 KB Pages: 46
Languages: English
Table of contents
- 5 Overview
- 5 Models
- 5 Room Air Distribution
- 5 Configuration
- 5 Compliance Approval
- 5 Standard Features
- 5 Optional Features
- 6 Standard Features
- 6 Cabinet
- 6 The frame is constructed of heavy gauge steel for maximum strength. Steel access panels are insul...
- 6 Evaporator Coil/Drain Pan
- 6 Humidifier
- 6 Electrical Panel
- 6 Air Filter
- 6 Electric Reheat
- 6 Fan/Motor Section
- 6 Main Power Disconnect
- 6 Refrigeration System and Compressor
- 7 Redundant Group Control
- 7 Condensate Pump
- 7 Environmental Monitoring Unit
- 8 Optional Features
- 8 Condenser
- 8 Water-Regulating Valve
- 8 Discharge Duct Collar
- 8 Secondary Drain Pan
- 8 Spot Water Detector(s)
- 8 Compressor Lockout
- 8 Cable Water Detector
- 8 Firestat
- 8 Smoke Detector
- 8 Remote Relay Shutdown
- 8 Reheat/Humidity Lockout
- 8 Remote Display Panel
- 8 Remote Sensor(s)
- 8 Hot Gas Bypass
- 8 3-Way Valve Flow Switch
- 8 Air Deflector
- 8 Plenum
- 8 OHE Disconnect
- 9 Floorstand
- 9 Environmental Management System
- 9 ModBus/JBus Gateway
- 9 Custom Alarm Contact Closures
- 9 Downflow Return Duct
- 9 Casters
- 10 Microprocessor Controller
- 10 Microprocessor Controller
- 10 Status
- 10 Alarms
- 10 Configuration
- 10 Common Alarm Contact
- 10 Run Times
- 10 Security
- 10 Monitoring
- 10 Cool Inhibit
- 10 Cool Override
- 10 Remote Shutdown
- 11 Performance Specifications—Air Cooled
- 12 Performance Specifications - Air Cooled
- 13 Performance Specifications—Water Cooled
- 14 Performance Specifications—Water Cooled
- 15 Performance Specifications—Glycol Cooled
- 16 Performance Specifications—Glycol Cooled
- 17 Electrical Data
- 18 Dimensional Data
- 22 Air-Cooled Condensers
- 22 Air-cooled condenser—performance/electrical data
- 25 Fluid Coolers
- 25 Glycol-cooled fluid cooler—performance/electrical data
- 25 *Fluid coolers can be selected for multiple indoor air conditioning units from the factory. Consu...
- 28 Pump Specifications
- 31 Guide Specifications
- 31 PART 1 — PART 1 GENERAL
- 31 1.01 SUMMARY
- 31 A. The environmental control system shall be designed specifically for precision temperature and ...
- 31 1.02 DESIGN REQUIREMENTS
- 31 A. The system shall be as described in the following specification as manufactured by APC.
- 31 1 . Model: ____________________________.
- 31 2 . Total cooling capacity: _______________ MBH (kW).
- 31 3 . Sensible cooling capacity: ____________ MBH (kW).
- 31 4 . Return air temperature: _______________ º F (º C) DB.
- 31 5 . Return air temperature: _______________ º F (º C) WB.
- 31 6 . Humidity: __________________________% RH.
- 31 7 . Air quantity: _______________________ CFM (L/s).
- 31 8 . External Static Pressure _______________inches (Pa).
- 31 9 . Humidifier capacity: _________________ lbs/hr (kg/hr).
- 31 10 . Electrical supply: ________ V, _________ ph, 60 Hz.
- 31 1.03 SUBMITTALS
- 31 A. Submittals shall be provided with the proposal and shall include: capacity data, electrical da...
- 31 1.04 QUALITY ASSURANCE
- 31 A. The system shall be completely factory-tested prior to shipment. Testing shall include, but no...
- 31 1.05 WARRANTY
- 31 A. System parts shall be warranted for a period of 12months from date of shipment from factory.
- 32 PART 2 — PART 2 PRODUCT
- 32 2.01 STANDARD COMPONENTS
- 32 A. MICROPROCESSOR
- 32 1 . The microprocessor controller shall provide total environmental control. The system, based on...
- 32 a. Status: Complete status monitoring shall be provided within the status menu of the microproces...
- 32 b. Alarms: Quick access to any alarm condition shall be facilitated through the menu structure. P...
- 32 c. Setpoint: The microprocessor controller shall provide independent setpoints for heating, cooli...
- 32 d. Configuration: Flexibility shall be offered through the use of the configuration menu. It shal...
- 32 e. Run time: The major components within the unit shall have independent run-timers that monitor ...
- 32 f. Security: The microprocessor shall have multiple security levels to prevent unauthorized adjus...
- 33 B. CABINET CONSTRUCTION
- 33 1 . The cabinet and frame shall be bolt together formed sheet steel. Access panels shall be flush...
- 33 C. FAN/MOTOR SECTION
- 33 1 . The unit shall be configured for draw-through air pattern, to provide uniform air-flow over t...
- 33 D. REFRIGERATION SYSTEM AND COMPRESSOR
- 33 1 . Each refrigeration system shall consist of a fully protected scroll compressor, evaporator co...
- 33 E. MAIN POWER DISCONNECT
- 33 1 . A non-automatic main power circuit breaker shall disconnect all high voltage power to the uni...
- 33 F. ELECTRICAL PANEL
- 33 1 . The electrical system shall conform to National Electrical Code (NEC) requirements. The contr...
- 34 G. EVAPORATOR COIL/DRAIN PAN
- 34 1 . The evaporator coil shall use the latest heat-transfer technology, raised lanced-aluminum fin...
- 34 H. AIR FILTER
- 34 1 . The air filters shall be 30% efficient per ASHRAE Standard 52.1-92, UL Class 2. The full 4” (...
- 34 I. HUMIDIFIER
- 34 1 . Humidifier shall be self-contained steam-generating type, factory piped and wired, with dispo...
- 34 J. ELECTRIC REHEAT
- 34 1 . Reheat elements shall be low watt density, wired for three-phase, loaded equally on all three...
- 34 K. CONDENSATE PUMP
- 34 1 . The Condensate Pump shall be factory installed and wired and shall pump 36 gal/h (0.06 L/s) a...
- 34 L. REDUNDANT GROUP CONTROL
- 34 1 . Up to six units shall have the ability to communicate with each other to automatically switch...
- 34 M. ENVIRONMENTAL MONITORING UNIT
- 34 1 . A stand-alone unit shall perform continuous temperature and humidity sensing through two avai...
- 35 2.02 OPTIONAL COMPONENTS
- 35 A. CONDENSER
- 35 1 . Water and glycol cooled systems shall employ a brazed plate condenser that uses the latest he...
- 35 B. WATER-REGULATING VALVES
- 35 1 . Water and glycol cooled systems shall utilize two-way or three-way valves to regulate the amo...
- 35 C. DISCHARGE DUCT COLLAR
- 35 1 . A 1” (25 mm) duct flange shall be provided for field installation on a unit to provide conven...
- 35 D. SECONDARY DRAIN PAN
- 35 1 . Systems shall be provided with two drain pans. The primary stainless steel condensate pan sha...
- 35 E. SPOT WATER DETECTOR
- 35 1 . A water detector shall be factory-wired and shipped in the bottom of the unit to sense water ...
- 35 F. CABLE WATER DETECTOR
- 35 1 . A leak detection sensing cable shall be shipped loose with the unit. If water or other conduc...
- 35 2 . The detector shall be provided with 20ft (6 m) of cable. Cable may be cascaded up to 1000ft (...
- 35 G. FIRESTAT
- 35 1 . A firestat shall be factory-installed in the return air to sense heat and send a signal to th...
- 36 H. SMOKE DETECTOR
- 36 1 . A smoke detector shall be factory-installed in the return air to sense concentrations of smok...
- 36 I. REMOTE RELAY SHUTDOWN
- 36 1 . Remote shutdown of the system can be done by a factory installed relay with a 24V, 120V, or 2...
- 36 J. COMPRESSOR LOCKOUT
- 36 1 . This lockout shall prevent compressor operation in emergency situations where limited back-up...
- 36 K. REHEAT/HUMIDITY LOCKOUT
- 36 1 . When facilities have limited backup power capacity, this lockout shall prevent the operation ...
- 36 L. REMOTE DISPLAY PANEL
- 36 1 . Facility and building-maintenance personnel shall have the ability to evaluate and control th...
- 36 M. REMOTE SENSOR(S)
- 36 1 . Environmental sensor(s) shall be strategically placed, up to 50ft from the unit to better mee...
- 36 N. HOT GAS BYPASS
- 36 1 . Activation of the hot gas bypass circuit shall maintain the evaporator coil temperature durin...
- 36 O. 3-WAY VALVE FLOW SWITCH
- 36 1 . A Single-Pole, Double-Throw flow switch shall be wired to energize one device and de- energiz...
- 36 P. AIR DEFLECTOR
- 36 1 . A ninety degree air deflector shall ship loose and shall be ________ in. (mm) high.
- 37 Q. FLOORSTAND
- 37 1 . The heavy gauge floorstand shall raise the unit above the subfloor to match the height of the...
- 37 R. PLENUM
- 37 1 . A discharge plenum shall mount on top of an upflow unit to direct and distribute conditioned ...
- 37 a. The plenum shall be manually adjustable with double deflecting grilles provided on 3 or 4 side...
- 37 b. The plenum shall be provided with a duct collar and no grilles. Plenum height shall be 24” (61...
- 37 S. ENVIRONMENTAL MANAGEMENT SYSTEM
- 37 1 . A browser-accessible, 1U, rackmountable appliance shall allow monitoring of environmental con...
- 37 T. OHE DISCONNECT
- 37 1 . A non-fused disconnect switch shall be wired to an outdoor heat exchanger to disconnect high ...
- 37 U. MODBUS/JBUS GATEWAY
- 37 1 . The Gateway shall translate transmission protocol from the system’s network into ModBus/JBus ...
- 37 V. DOWNFLOW RETURN DUCT
- 37 1 . A return duct the length and width of the unit shall be provided for field installation on a ...
- 38 W. CUSTOM ALARM DRY CONTACT CLOSURES
- 38 1 . Each unit shall be equipped with any or all or the listed dry contact closures. Upon activati...
- 38 a. High Temperature Alarm
- 38 b. Low Temperature Alarm
- 38 c. High Humidity Alarm
- 38 d. Low Humidity Alarm
- 38 e. Compressor High Head Pressure Alarm
- 38 f. Clogged Filter Alarm
- 38 g. Fire Alarm (with Firestat)
- 38 h. Smoke Alarm (with Smoke Detector)
- 38 i. Humidifier Change Canister Alarm
- 38 j. Water Underfloor Alarm (with Water Detector)
- 38 k. Condensate Pump Overflow Alarm (with Condensate Pump)
- 38 l. Loss of Flow (with Flow Switch)
- 39 PART 3 — PART 3 INDIVIDUAL SYSTEMS
- 39 3.01 AIR-COOLED
- 39 A. The indoor unit shall consist of an evaporator section including evaporator coil, blower packa...
- 39 B. CONDENSER
- 39 1 . Outdoor Propeller Fan Condenser: The outdoor condenser casing shall be made of aluminum, and ...
- 39 2 . Flooded Controls: Flooded controls shall maintain head pressure to -30º F (-34.4ºC) by regula...
- 39 3.02 WATER-COOLED
- 39 A. The water-cooled system shall consist of an evaporator section including evaporator coil, blow...
- 39 3.03 GLYCOL-COOLed
- 39 A. The glycol-cooled system shall consist of an evaporator section including evaporator coil, blo...
- 40 B. FLUID COOLER
- 40 1 . Outdoor Fluid Cooler: The fluid cooler casing shall be of aluminum, and all structural suppor...
- 40 C. PUMP PACKAGE
- 40 1 . Single Pump Package: The pump package shall be comprised of a centrifugal pump in a vented en...
- 40 2 . Dual Pump Package: The dual pump package shall consist of two centrifugal pumps in an enclosu...
- 41 Guidelines for Installation
- 41 Room preparation
- 41 Unit location
- 42 Service access
- 42 Receiving the unit
- 42 Rigging
- 42 Floorstand
- 42 Utility connections
- 42 Power unit
- 42 Humidifier connections
- 42 Condensate drain
- 43 Water supply to humidifier
- 43 1 . The humidifier fill valve orifice is sized for supply water pressure from 15 PSIG (103.4 kPa)...
- 43 2 . For cases above 150 PSIG (1034 kPa), install a pressure-reducing valve in the water feed line...
- 43 3 . With extremely dirty or muddy water sources, proper filtration is required on the unit’s inco...
- 43 4 . DO NOT use softened water with the humidifier. Softened water is too conductive.
- 43 5 . DO NOT use completely demineralized water with the humidifier. The minerals allow the electro...
- 43 6 . DO NOT use a hot water source. Doing so will cause deposits that will eventually block the fi...
- 43 7 . Water supplies with high conductivity (above 800 mW) must be preconditioned for proper operat...
- 43 Water supply
APC AFX Series Technical information
Brand: APC Category: Dehumidifiers Size: 388 KB Pages: 23
Languages: English
Table of contents
- 4 Overview
- 4 Save these instructions
- 4 Safety symbols that may be used in this manual
- 4 Cross-reference symbols used in this manual
- 5 Safety
- 6 Inspecting the Equipment
- 6 Filing a claim
- 6 Storing the Equipment Before Installation
- 7 Configuration and Integration
- 7 Introduction
- 7 Wiring Diagrams
- 7 Electrical Connections
- 7 Electrical Data
- 7 Piping Diagrams
- 7 Flooded Receiver
- 7 System Installation
- 7 Operational Temperature Controls
- 8 Electrical Connections
- 9 Electrical Data
- 10 Piping Diagrams
- 11 System Installation
- 11 Installing the flooded receiver
- 12 Refrigerant Piping
- 12 Recommended line sizes
- 13 Fittings and valves
- 14 Charging the system
- 16 Piping Volume
- 16 Piping Insulation
- 16 Temperature Controls
- 16 Operation
- 17 Setpoint adjustment
- 17 Differential adjustment
- 17 Adjusting the A350A/B
- 18 Adjusting the S350A/B
- 19 Default jumper settings for “heating”, relay NC
- 20 Adjustments to A350A/B
- 21 Jumper setting: cooling with relay NO
- 22 Jumper set as “cooling”, relay NO