Manuals and User Guides for APC BR700G. We found 2 manuals for free downloads: Specification, User manual
APC Back-UPS 700 User manual
Brand: APC Category: Uninterruptible power supplies (UPSs) Size: 198 KB Pages: 8
Languages: English
Table of contents
- 1 Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids.
- 1 Do not connect a laser printer or hair dryer to the unit.
- 1 Ensure that the connected equipment does not exceed the maximum load.
- 1 Mute
- 1 Ethernet ports
- 1 Power On/Off
- 1 Master outlet
- 1 Display/Menu
- 1 Circuit breaker
- 1 Display interface
- 1 Battery back-up outlets
- 1 Surge protection outlets
- 1 Controlled outlets
- 1 Data port
- 1 Charge the battery for at least 16 hours before use.
- 2 1 . Connect equipment to the Battery Backup and Surge Protection outlets. When the Back-UPS is re...
- 2 2 . Use the AC power cord to connect the Back-UPS directly to a utility power outlet.
- 2 3 . Connect a router or cable modem to the corresponding ports.
- 2 1 . Connect the supplied USB software interface cable to the data port, and the other end to a co...
- 2 2 . Go to www.apc.com/tools/download.
- 2 3 . Select PowerChute Personal Edition. Then select the appropriate operating system and follow t...
- 2 On Line—The UPS is supplying utility power to connected equipment
- 2 Power-Saving—Master and controlled outlets are enabled, saving power when the master device goes ...
- 2 Load Capacity—The load is indicated by the number of sections illuminated, one to five. If the lo...
- 2 Battery Charge—The battery charge level is indicated by the number of sections illuminated. When ...
- 2 Overload—The power demand from the load has exceeded the capacity of the Back-UPS.
- 2 Event—An event has occurred and the unit needs attention.
- 2 Automatic Voltage Regulation—The unit is compensating for extremely low input voltage, but is not...
- 2 In—Input voltage. Out—Output voltage.
- 2 System Faults—The system has a fault. The fault number will illuminate on the display interface. ...
- 2 Mute—The audible alarm has been turned off.
- 2 Replace Battery—The battery is not connected or is nearing the end of its useful life. Replace th...
- 2 On Battery—The unit is supplying battery backup power to the connected equipment, it will beep fo...
- 3 Press Display to scroll through the display screens.
- 3 Input Voltage
- 3 Estimated runtime in minutes
- 3 Counter
- 3 Power Event Counter
- 3 Estimated run time
- 3 Output Voltage
- 3 Load in Watts
- 3 Input Voltage
- 3 Load in %
- 3 Load in Watts
- 3 Output Voltage
- 3 Load in %
- 3 Output Frequency
- 3 Output Frequency
- 3 AVR: The Automatic Voltage Regulation (AVR) feature will compensate for excessively low input vol...
- 3 To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop c...
- 3 Enable the Power-Saving feature
- 3 Press and hold Mute and Display simultaneously for two seconds. The unit will beep to indicate th...
- 3 Disable the Power-Saving feature.
- 3 Press and hold Mute and Display simultaneously for two seconds. The unit will beep to indicate th...
- 3 Setting the threshold
- 3 The amount of power used by a device in Sleep or Standby mode varies between devices. It may be n...
- 3 1 . Ensure a master device is connected to the Master outlet. Put that device into Sleep or Stand...
- 3 2 . Press Display and Mute simultaneously and hold for six seconds, until the leaf icon flashes t...
- 3 3 . The Back-UPS unit will now recognize the threshold level of the Master device and save it as ...
- 3 When unit power is On, the LCD may remain illuminated or be darkened for energy savings.
- 3 1 . Full Time LCD Mode: Press and hold DISPLAY for two seconds. The LCD will illuminate and the u...
- 3 2 . Power-Saving Mode: Press and hold DISPLAY for two seconds. The LCD will darken and the unit w...
- 4 Adjust the sensitivity of the UPS to control when it will switch to battery power; the higher the...
- 4 1 . Ensure the unit is connected to utility power, but is OFF.
- 4 2 . Press and hold the Power button for six seconds. The Load Capacity bar will flash on and off,...
- 4 3 . Press Power again to rotate through the menu options. Stop at selected sensitivity. The unit ...
- 4 Low sensitivity
- 4 Medium sensitivity
- 4 High sensitivity
- 4 Input voltage is extremely low or high. (Not recommended for computer loads.)
- 4 The Back-UPS frequently switches to battery power.
- 4 The connected equipment is sensitive to voltage fluctuations.
- 4 Warnings and System Faults
- 4 Press Display to scroll through the display screens.
- 4 ON LINE overload condition, indicated by the illuminated ON LINE icon, and the flashing overload ...
- 4 In ON LINE mode, and there is a bad battery, indicated by the flashing icon.
- 4 Backup battery (ON BATT) overload condition. This is indicated by the flashing overload icon.
- 4 The battery charge is low, and the Battery Charge indicator bar is flashing.
- 4 The unit will display the fault messages. Contact APC Technical Support for additional support.
- 4 • F01 - On-Battery Overload
- 4 • F02 - On-Battery Output Short
- 4 • F03 - On-Battery Xcap Overload
- 4 • F04 - Clamp Short
- 4 • F05 - Charge Fault
- 4 • F06 - Relay Welding
- 4 • F07 - Temperature
- 4 • F08 - Fan Fault
- 4 • F09 - Internal Fault
- 5 Function Button Quick-Reference
- 5 Power
- 5 Power On
- 5 Press Power to start receiving input utility power. If A/C input power is not available, the unit...
- 5 Power Off
- 5 The unit is not receiving input utility power, but is providing surge protection.
- 5 Display
- 5 Status Inquiry
- 5 Verify the status or condition of the unit. The LCD will illuminate for 60 seconds.
- 5 Full-Time/Power- Saving mode
- 5 The LCD will illuminate and the unit will beep to confirm the Full-Time mode. The LCD will darken...
- 5 Mute
- 5 Event Specific
- 5 Disable any audible alarms caused by an event.
- 5 General Status Enable/ Disable
- 5 Enable or disable the audible alarms. The Mute icon will illuminate and the unit will beep one ti...
- 5 Sensitivity
- 5 The Load Capacity icon will blink, indicating that the unit is in programming mode. Use the Power...
- 5 Master/Controlled outlet Enable/Disable
- 5 The leaf icon will darken indicating that the Master Outlet feature is disabled or illuminate to ...
- 5 Master/Enable Threshold Calibration
- 5 While calibrating the threshold setting, the device connected to the Master Outlet should be turn...
- 5 Self-Test (manual)
- 5 The UPS will perform a test of the internal battery. Note: This will happen automatically when th...
- 5 Event Reset
- 5 When the Event screen is visible, press and hold Display, then press power, to clear the utility ...
- 5 Fault Reset
- 5 After a fault has been identified, press Power to remove the visual indication and return to stan...
- 6 Troubleshooting
- 6 Battery Backup outlets may be fully or improperly loaded.
- 7 Specifications
- 7 General
- 7 Topology
- 7 Line-Interactive
- 7 Input
- 7 Rated input voltage
- 7 120 Vac
- 7 Phase
- 7 Single phase 2+ ground
- 7 Frequency
- 7 50/60 Hz (autosensing)
- 7 Input voltage range
- 7 (on AVR operation)
- 7 Default setting: 88 V-141 V
- 7 Lower Limit Voltage Range: 78 V- 144 V
- 7 Upper Limit Voltage Range: 88 V- 137 V
- 7 Power cable length
- 7 6 ft
- 7 Input plug type
- 7 NEMA5-15
- 7 Output
- 7 Output plug type
- 7 NEMA5-15R
- 7 Output outlet
- 7 Back-up outlets (3)
- 7 Surge outlets (3)
- 7 Maximum load
- 7 700 VA/420 W
- 7 Output voltage
- 7 115 Vac + 8%
- 7 Frequency
- 7 50/60 Hz +1
- 7 On-battery waveform
- 7 Stepped sine wave
- 7 Transfer time
- 7 Maximum 8 ms
- 7 Surge Protection/Noise
- 7 Surge protection
- 7 Yes
- 7 Noise filter
- 7 Yes
- 7 Data line protection
- 7 ADSL, ISDN, 10/100Base-T
- 7 Interface
- 7 Interface
- 7 USB v1.1
- 7 If the Back-UPS arrived damaged, notify the carrier.
- 7 If the Back-UPS requires service, do not return it to the dealer.
- 7 1 . Consult the Troubleshooting section to eliminate common problems.
- 7 2 . If the problem persists, go to http://www.apc.com/support/.
- 7 3 . If the problem still persists, contact APC Technical Support.
APC BR700G Uninterruptible Power Supply (UPS) Specification Sheet
Brand: APC Size: 78 KB Pages: 2
Languages: English
Open in a new tab