APC Smart-UPS 5000UXI

Manuals and User Guides for APC Smart-UPS 5000UXI. We found 1 manuals for free downloads User's manual

The American Power Conversion 5000UXI boasts a 5000 VA/4500 Watt capacity, providing ample power protection for your critical electronic equipment. Its advanced line-interactive topology and automatic voltage regulation (AVR) ensure consistent, clean power output, safeguarding your devices from damaging voltage fluctuations and surges. With a typical transfer time of 2-6 milliseconds to battery power, the 5000UXI offers reliable backup power during outages, allowing you to work seamlessly without data loss or disruption. The UPS also features eight IEC 320 C13 outlets, providing versatile connectivity options for various devices, while its intuitive LCD display offers clear status information and easy configuration. Additionally, the 5000UXI is compatible with PowerChute software, enabling remote monitoring and management of the UPS via a network connection.

Key Features

  • Prevents blackouts, brownouts, sags and surges
  • Filters out small utility line fluctuations
  • Supplies power from its external batteries
  • Provides automatic unattended shutdown capabilities
  • Offers optional accessory slot
  • Features TVSS connector for connecting ground lead
  • Supports 10 battery packs
  • Includes a self-test feature

Pages: 18 APC Smart-UPS 5000UXI User's manual

Brand: APC Category: Uninterruptible power supplies (UPSs) Size: 399 KB

Languages: English

Open manual

Frequently Answers and Questions

How do I connect the external batteries to the SU5000UXI?
The SU5000UXI contains no internal batteries. The figure shows the location of the battery pack connector on the UPS. Battery pack connectors are color coded; the 48 Vdc UXBP48M connector is blue. Battery pack connectors are also keyed to prevent improper connection. Do not try to install battery packs with connectors that are a different color from the battery pack connector in the UPS. The SU5000UXI can support a maximum of 10 battery packs.
What is the procedure for cold starting the UPS?
When the UPS is off and there is no utility power, use the cold start feature to apply power to the loads from the UPS’s battery. Press and hold the on/test button until the UPS beeps. Release the on/test button during the beep and the loads are powered within four seconds.
What are the steps to take if the UPS is overloaded?
When the UPS is overloaded (the connected loads exceed 5000 VA / 3750 W) , the overload LED comes on and the UPS emits a sustained tone. The alarm remains on until the overload is removed. Disconnect nonessential load equipment from the UPS to eliminate the overload.