Accu-Scope EXC-500

Manuals and User Guides for Accu-Scope EXC-500. We found 3 manuals for free downloads User manual, Owner's manual

Below you will find brief information for microscope EXC-500, microscope EXC-500-BE, microscope EXC-500-T, microscope EXC-500-TE, microscope EXC-500-MB. The EXC-500 series microscopes are engineered and manufactured to the highest quality standards. Your microscope will last a lifetime if used and maintained properly. ACCU-SCOPE microscopes are carefully assembled, inspected and tested by our staff of trained technicians in our New York facility.

Key Features

  • Infinity optical system

  • LED illumination

  • Coaxial coarse and fine focusing

  • Gorilla™ Glass stage

  • Achromat swing out condenser

  • Siedentopf or ergonomic viewing head

  • Trinocular viewing head

Pages: 25 Accu-Scope EXC-500 User manual

Brand: Accu-Scope Category: Microscopes Size: 2 MB

Languages: English

Open manual

Other manuals and documents

25 Pages

User manual

Languages: English

14 Pages

Owner's manual

Languages: English

Frequently Answers and Questions

How do I adjust the stage tension?

To adjust the tension, pull the bottom Stage Movement Knob ① down to expose the tension adjustment rings ② for the X-Y direction. To loosen, turn each ring counter-clockwise, or clockwise to tighten. Push the bottom knob up when you reach the desired tension.

How do I replace the fuses?

To replace the fuses, turn the power off and unplug the microscope from the wall outlet and then from the power cord receptacle on the back of the microscope. Insert a small flat head (-) screwdriver into the top of the fuse holder drawer ① and carefully slide it open to expose the two fuses. Being careful not to break the glass of either of the fuses, gently insert the screwdriver up through the bottom openings of the drawer as shown and push each fuse up to remove. Replace the fuses with 250v T2.5A fuses, CAT# 500-3277 Slide the fuse holder drawer back in place.

How do I center the condenser?

Rotate either of the condenser knobs ① to raise it to the highest position. Rotate the 10x objective into the light path and focus the specimen. Rotate the field iris diaphragm adjustment ring ② to put the field iris diaphragm to the smallest position. Rotate the condenser knob and adjust the image to be its sharpest. Using the Hex wrench provided, adjust the center adjustment screws ③ and move the specimen to the center of the field of view. Open the field iris diaphragm gradually. If the image is in the center all the time and inscribed to the field of view, the condenser has been centered correctly. On the front of the condenser, select the number that matches your objective lens.