Aseptico AMC-20

Инструкции и руководства для Aseptico AMC-20. Мы нашли 5 инструкции доступные для бесплатного скачивания Owner's manual, Product Datasheet, Operation manual, Service manual

Aseptico AMC-20: Your All-in-One Dental Solution The Aseptico AMC-20 is a fully self-contained mobile dental operatory, providing you with the freedom to practice dentistry anywhere. With its built-in air compressor, vacuum pump, water and waste systems, you can set up and start working without the need for additional plumbing or installation. The AMC-20 features two automatic high-speed air handpiece connections, one automatic low-speed handpiece connection, high and low volume suction with automatic overflow protection and solids trap, a 3-way air/water syringe, and two 1-liter bottles for irrigation.

Ключевые особенности

  • Integrated air compressor and vacuum system
  • Connections for high-speed handpieces, curing light, and scaler
  • On-board waste pump
  • 110V/220V accessory outlets
  • Air-activated instrument holders
  • Portable design for mobile dental care

Страниц: 28 Aseptico AMC-20 Owner's manual

Бренд: Aseptico Категория: Medical equipment Размер: 1 MB

Языки: English

Открыть мануал

Другие мануалы и документы

2 Страниц

Product Datasheet

Языки: English

12 Страниц

Owner's manual

Языки: English

28 Страниц

Operation manual

Языки: English

56 Страниц

Service manual

Языки: English

Часто задаваемые вопросы

How do I verify that the AMC-20CF unit is functioning properly?
First, follow the Setup procedure in the Operation and Maintenance Manual. Ensure the voltage selector switch is set correctly and that the circuit breakers are in good condition.
How do I clean the water lines?
Disinfect the water lines weekly with a 1:10 bleach solution. Purge the lines with air. Ensure to flush thoroughly with clean water afterward and leave dry until the next clinical use.
What type of lubricant should I use?
Use a silicone base lubricating grease, such as Parker Super O-Lube, to lubricate O-rings and seals in the system.
What should I do if the compressor runs continuously?
If HVE and saliva ejector instruments are seated properly but compressor fails to turn off, turn the unit's power switch OFF and check for air leaks in the System.

Вопросы и ответы

2024-11-11

N N R

What is the PN 510704 cable?
More information is needed to identify the PN 510704 cable. Please specify the cable's connected component, location within the unit, color, and configuration.