Below you will find brief information for Fountain DF-DUAL Pedestal Barrier Free Stone. This manual provides information on the installation and maintenance of the DF-DUAL Pedestal Barrier Free Stone Fountain. The fountain is designed to be easily installed and requires a 3/8” O.D unplated copper tube, 1-1/4” IPS waste line, and a waste trap and service stop valve in accordance with local code.

Key Features

  • Barrier Free Stone Fountain
  • Easy Installation
  • Dual Stream
  • Adjustable Stream Height
  • Water Pressure Regulator
  • Orifice Cleaning

Pages: 4 BOHLMANN DF-DUAL Pedestal Barrier Free Stone Owner's manual

Brand: BOHLMANN Category: Fireplaces Size: 76 KB

Languages: English

Open manual

Frequently Answers and Questions

How do I install the fountain?
The fountain must be mounted on a smooth, flat, finished surface with adequate support structure. Refer to the rough-in for plumbing, install a shut-off valve on the water supply, locate and install the fountain using 3/8” minimum anchor screws or bolts, connect the water supply and fountain drain, turn on the water supply and check all connections for leaks.
What type of water supply is needed?
The fountain requires a 3/8” O.D unplated copper tube for the water supply and a 1-1/4” IPS waste line for the drain.
How do I adjust the stream height?
The stream height is factory set at 45-50 PSI. If the supply pressure varies greatly from this, remove items 1 and 2 from the Parts List and adjust the screw on item 4. Clockwise adjustment will raise the stream and counter-clockwise adjustment will lower the stream. For best adjustment, the stream should hit the basin approximately 6-1/2” from the bubbler.
What is the maximum water pressure for the fountain?
The fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI.
How do I clean the orifice?
Mineral deposits on the orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file or small diameter wire. CAUTION: DO NOT file or cut orifice material.
How do I remove tubing from the quick connect fittings?
To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.