Copeland Scroll ZPV, ZHV, ZHW variable speed compressor

Manuals and User Guides for Copeland Scroll ZPV, ZHV, ZHW variable speed compressor. We found 1 manuals for free downloads Operating instructions

The ZPV, ZHV, ZHW variable speed compressor is a high-efficiency, variable speed compressor designed for use in residential and light commercial HVAC applications. It is a scroll compressor, which means that it uses a pair of spiraling scrolls to compress the refrigerant. The variable speed feature allows the compressor to operate at different speeds, which can help to improve efficiency and reduce noise. The compressor is designed for use with R-410A refrigerant.

Key Features

  • Variable speed operation
  • Scroll compressor design
  • High efficiency
  • Low noise operation
  • Designed for R-410A refrigerant

Pages: 2 Copeland Scroll ZPV, ZHV, ZHW variable speed compressor Operating instructions

Brand: Copeland Scroll Category: Industrial & lab equipment Size: 295 KB

Languages: English

Open manual

Frequently Answers and Questions

What type of refrigerant does the compressor use?
The ZPV, ZHV, ZHW compressor is designed for use with R-410A refrigerant only.
What is the proper way to remove the failed compressor?
Disconnect and lock-out the power supply to the unit. Allow drive components to electrically discharge for a minimum of two minutes before servicing. Verify that the power supply has been disconnected and locked-out and use a volt meter to ensure that no voltage is present at the unit. Using a service manifold gauge set, verify that the refrigerant charge has been completely recovered from the system. If the compressor has rotalock connections, use the appropriate wrenches to loosen and disconnect the rotalock fittings. If the compressor has brazed connections, cut the suction and discharge tubes close to the compressor using a tubing cutter (do not use a hacksaw and do not attempt to unbraze the suction and discharge tubes). Remove the compressor mounting bolts. Using caution and the appropriate lifting device, remove the compressor from the unit.
What should be done with the failed compressor?
Follow the instructions of the service compressor provider on what to do with the failed compressor. If the compressor is field scrapped, the oil must be drained from the compressor and properly disposed of. If the compressor is returned to Emerson, the compressor tubes must be properly plugged and the compressor must be securely bolted to a skid, in the upright position, for shipping.