- 11 1. INTRODUCTION
- 11 1.1. Description
- 12 1.2. Summary of Features
- 17 2. TECHNICAL SPECIFICATIONS
- 17 2.1. Inputs and Outputs
- 19 2.2. Type Withstand Tests
- 21 2.3. Metering Accuracy
- 22 2.4. Fault Indication Type Functions
- 23 2.5. Protection Type Functions
- 25 2.6. Direction Controls
- 26 2.7. Cold Load Pickup
- 26 2.8. Loop Control
- 27 2.9. Monitoring
- 35 2.10. Recorder
- 41 2.11. Communications
- 42 3. APPLICATION
- 43 4. DIMENSIONS AND CONSTRUCTION
- 44 5. SIDE PANEL CONSTRUCTION
- 45 5.1. Communication Port
- 47 5.2. NTC Connector
- 48 5.3. Current Input Connector
- 48 5.4. Voltage Input Connector
- 49 5.5. Status Inputs Connector
- 49 5.6. Outputs Connector
- 50 5.7. SCADA Connector (Option)
- 50 5.8. Power Input / Battery Input Connector
- 51 5.9. Power Output Connector
- 51 5.10. Charge Circuit
- 52 5.11. Battery Protection
- 53 5.12. Typical Wiring Diagram
- 54 6. USER INTERFACE PANEL
- 55 6.1. Construction
- 55 6.1.1. Operation Section
- 56 6.1.2. Local Control Section
- 59 6.1.3. Menu Control Section
- 61 6.1.4. Fault Indication Section
- 61 6.1.5. Voltage Element Section
- 61 6.1.6. System Diagnostic Section
- 62 6.1.7. Battery Status Section
- 62 6.1.8. User LED Section
- 63 6.1.9. Set Group Status Section
- 64 6.2. LCD Display
- 64 6.2.1. Menu Structure Tree
- 67 6.2.2. GLOBAL Setting
- 68 6.2.3. GROUP Setting
- 69 6.2.4. Event
- 69 6.2.5. Maintenance
- 69 6.2.6. Time
- 69 6.2.7. Status
- 69 6.2.8. Metering
- 70 6.3. Using the LCD Menu
- 70 6.3.1. Initial Screen
- 73 6.3.2. Main Menu
- 73 6.3.3. Setting Example
- 74 6.3.4. Setting Save
- 75 7. GLOBAL SETTING
- 75 7.1. General Setting
- 76 7.1.1. System
- 83 7.1.2. Event Recorder
- 86 7.1.3. Monitoring
- 103 7.1.4. Loop Control
- 120 7.1.5. Passcode
- 121 7.1.6. PLC
- 130 7.1.7. Device
- 139 7.1.8. Save Setting
- 140 7.2. Communication
- 140 7.2.1. Protocol Setup
- 174 7.2.2. Port Setup
- 181 7.2.3. RTU Communication (Dialup Modem) Setup
- 186 7.2.4. FTP-SSL
- 187 7.2.5. Wifi
- 188 7.2.6. Event & Etc Setup
- 192 7.2.7. Save Setting
- 193 8. GROUP SETTING
- 194 8.1. Fault Indication
- 194 8.1.1. FI Type
- 195 8.1.2. FI Pickup Current
- 196 8.1.3. FI Setting Time
- 200 8.1.4. Inrush Restraint
- 201 8.1.5. FI Auto Reset
- 202 8.2. Protection
- 205 8.2.1. Phase Time Overcurrent (51P)
- 210 8.2.2. Ground Time Overcurrent (51G)
- 214 8.2.3. Negative Sequence Overcurrent (51Q(46))
- 218 8.2.4. Phase Instantaneous Overcurrent (50P)
- 220 8.2.5. Ground Instantaneous Overcurrent (50G)
- 222 8.2.6. Sensitive Earth Fault (50SG)
- 224 8.2.7. Negative Sequence Instantaneous Overcurrent (50Q)
- 226 8.2.8. Inrush Restraint
- 235 8.2.9. User Curve - Time Overcurrent Curves
- 270 8.3. Directional Controls (67)
- 270 8.3.1. Phase Directional Controls (67P)
- 273 8.3.2. Ground Directional Controls (67G)
- 275 8.3.3. SEF Directional Controls (67SEF)
- 276 8.3.4. Negative Sequence Directional Controls (67Q)
- 279 8.4. Cold Load Pickup
- 282 8.5. Monitoring
- 282 8.5.1. Broken Conductor(46BC)
- 284 8.5.2. Voltage (27/59/64N/47P)
- 288 8.5.3. Frequency (81)
- 296 8.5.4. Power (32)
- 300 8.5.5. Demand (49)
- 302 8.5.6. Phase Difference
- 304 8.5.7. Synchro’ Check (25)
- 308 8.5.8. Open Phase
- 309 8.5.9. Live Line Block
- 310 8.5.10. Fault Locator
- 313 8.5.11. Load Current Alarm
- 315 8.5.12. Power Factor (55)
- 316 8.6. Save Setting
- 317 9. EVENT RECORDER
- 318 9.1. Operation Event
- 319 9.2. Fault Event
- 321 9.3. Fault Cycle - Summary
- 322 9.4. System Event
- 323 9.5. Set Change Event
- 324 9.6. Load & Energy Event
- 324 9.6.1. Load & Energy/Min. Event
- 326 9.6.2. Load & Energy/Hour Event
- 327 9.6.3. Load & Energy/Day
- 328 9.6.4. Load & Energy Field Configuration
- 329 9.7. Diagnostic Event
- 331 9.8. PQM Event
- 332 9.9. Load Current Alarm Event
- 334 9.10. Clear Saved Data
- 335 10. MAINTENANCE
- 335 10.1. Count
- 335 10.1.1. ETMFC610 Count
- 336 10.1.2. Fault Count
- 337 10.1.3. PQM Count
- 341 10.1.4. Communication Count
- 342 10.1.5. User Count
- 343 10.2. Interrupt Time
- 343 10.3. Contact Wear
- 344 10.4. Data Reset
- 344 10.5. Controller Information
- 345 10.6. Mechanism Scale
- 346 11. TIME
- 347 12. STATUS
- 347 12.1. ETMFC
- 349 12.2. Input Ports
- 349 12.3. Output Ports
- 350 12.4. GOOSE Single Input
- 350 12.5. GOOSE Double Input
- 351 12.6. GOOSE Output
- 351 12.7. Latch Logic
- 352 12.8. Diagnostic
- 353 13. METERING
- 353 13.1. Current
- 354 13.2. Voltage
- 356 13.3. Frequency
- 357 13.4. Power
- 358 13.5. Energy
- 359 13.6. Demand Current and Power
- 361 13.7. Unbalance
- 362 13.8. Harmonics
- 362 13.9. True R.M.S
- 363 13.10. Controller Reference
- 364 14. MAINTANANCE
- 364 14.1. Warning Events
- 367 15. PLC function
- 368 16. Function of File Transfer Protocol
- 368 16.1. Patching firmware to upgrade
- 369 16.2. COMTRADE
- 369 16.2.1. File format and Name
- 369 16.2.2. Related Setting Items
- 370 17. Wireless Connection
- 370 17.1. Connection using WIFI (PC)
- 371 17.2. Connection using Smart ETIMS