ICP DAS ET-M8194H

Manuals and User Guides for ICP DAS ET-M8194H. We found 1 manuals for free downloads User manual

Below you will find brief information for motion control module ET-M8194H. The ET-M8194H is a motion control module that implements Ethernet remote motion control for remote motion solutions. It includes an i-8094H module, a 4-axis stepping/pulse-type servo motor control module. By using the intelligent function of the ET-M8194H, we can do remote motion control for various motion applications via MODBUS/TCP. It is easy and simple to use many ET-M8194Hs at the same time to implement multi-axis motion control by serial connection of ET-M8194H.

Key Features

  • Ethernet remote motion control
  • MODBUS/TCP communication
  • 4-axis stepping/pulse-type servo motor control
  • Easy to use for multi-axis motion control
  • Includes an i-8094H module
  • Supports serial connection of multiple modules
  • Multiple function modes: RTC, MP, ISR, IT
  • Provides EzMove Utility and API Library

Pages: 389 ICP DAS ET-M8194H User manual

Brand: ICP DAS Category: Electrical equipment & supplies Size: 2 MB

Languages: English

Open manual

Frequently Answers and Questions

How do I register the i8094H motion control module before performing any operation?
You need to use the i8094H_REGISTRATION() function. This function registers the module, assigns the slot number where it's installed, and accesses a card number.
How do I reset the I8094H motion control module to its power-on default settings?
Use the ETM_RESET_CARD() function. This function restores the module to its default settings as defined in Section 7: initial settings.
What are the available axis assignments and their corresponding codes for the ET-M8194H?
The available axis codes are: X=1, Y=2, Z=4, U=8. You can assign single axes or multiple axes, such as AXIS_XY = 3, AXIS_XYZU = 15.
How do I read the current version of the i8094H library?
Use the i8094H_GET_VERSION() function. This function returns the version number as a WORD value, e.g., 0x0607 represents version 2006-07.
How do I check the firmware version of the ET-M8194H controller?
Use MODBUS command FC=4 to read the address 0x52. The returned value 0x02000000 indicates version 2.00.