Manuals and User Guides for James Hardie HardieSmart Boundary. We found 1 manuals for free downloads Manual

HardieSmart Boundary and HardieSmart ZeroLot are boundary wall systems designed for residential and multi-residential applications, including bushfire zones. These systems provide fire resistance, acoustic, energy efficiency, and bracing performance. The HardieSmart Boundary wall system is ideal for buildings where external walls are in close proximity to the boundary, while the HardieSmart ZeroLot wall system is designed for multi-occupancy projects where a dual boundary wall solution is required between tenancies.

Key Features

  • Fire Resistance Level (FRL) up to 1 hour
  • Excellent acoustic performance
  • Energy efficiency
  • Bracing performance
  • Suitable for bushfire zones
  • Designed for close proximity to boundary
  • Dual boundary wall solution for multi-occupancy projects
  • Fully detached construction for townhouses and terraces
  • Flexibility of building process

Pages: 12 James Hardie HardieSmart Boundary Manual

Brand: James Hardie Category: Motor vehicle accessories & components Size: 1 MB

Languages: English

Open manual

Frequently Answers and Questions

What is the minimum setback from the boundary line for the HardieSmart ZeroLot wall system?
The HardieSmart ZeroLot wall system specifies a minimum setback of 12.5mm from the boundary line when capped and installed in accordance with this guide.
What is the recommended setback for the HardieSmart Boundary wall system when built against an existing structure?
A minimum setback of 500mm is recommended to allow for paint maintenance in accordance with the coating manufacturer’s instructions.
What are the maximum dimensions of wall modules for the HardieSmart ZeroLot and Boundary wall systems?
Wall modules height and length should not exceed 3.6m and 6m, respectively.
What types of timber can be used for the framing of the HardieSmart ZeroLot and Boundary wall systems?
Only dry seasoned dry timber is suitable. Steel frames are not suitable.
What is the maximum stud spacing for the HardieSmart ZeroLot and Boundary wall systems?
The maximum stud spacing is 600mm.