Ohio Medical Push-To-Set Continuous Vacuum Regulator

Manuals and User Guides for Ohio Medical Push-To-Set Continuous Vacuum Regulator. We found 1 manuals for free downloads Service manual

Below you will find brief information for Vacuum Regulator Push-To-Set Continuous Vacuum Regulator. The Push-To-Set Continuous Vacuum Regulator is a lightweight, compact unit used throughout the hospital primarily for pharyngeal/tracheal suctioning (airway management). Various models provide regulated or full-line vacuum for hospital suction procedures.

Key Features

  • Lightweight and compact
  • Provides regulated or full-line vacuum
  • Includes vacuum gauge
  • Features positive pressure safety relief valve
  • Low models have vacuum relief valve to limit maximum suction
  • Operates in regulated or non-regulated mode
  • Automatically adjusts suction level
  • Easy to use and adjust
  • Safe and reliable

Pages: 24 Ohio Medical Push-To-Set Continuous Vacuum Regulator Service manual

Brand: Ohio Medical Category: Medical equipment Size: 1016 KB

Languages: en

Table of contents

Open manual

Frequently Answers and Questions

What is the purpose of the Push-To-Set Continuous Vacuum Regulator?
The Push-To-Set Continuous Vacuum Regulator is used to provide suction for various medical procedures, primarily for pharyngeal/tracheal suctioning (airway management).
How do I set the suction level on the Push-To-Set Continuous Vacuum Regulator?
To set the suction level, turn the mode selector switch to "I" (On) and rotate the suction control knob until the vacuum gauge indicates the desired setting.
What is the difference between the regulated and non-regulated modes on the Push-To-Set Continuous Vacuum Regulator?
In the non-regulated (MAX) mode, the vacuum source is connected directly to the fitting port, providing full-line vacuum. In the regulated mode, the vacuum source is connected through the regulator module, which functions as an automatic valve to control the suction level.
How do I clean the Push-To-Set Continuous Vacuum Regulator?
Routine cleaning is recommended after each use. Wipe all exterior surfaces with a solution of water and mild detergent. If the regulator becomes flooded with patient fluid, all internal components (except the gauge) can be cleaned with a solution of warm water and mild detergent. Dry all components thoroughly before assembly.
How do I sterilize the Push-To-Set Continuous Vacuum Regulator?
The only acceptable method of sterilization is with gas (ethylene oxide). Follow the sterilization instructions provided in the manual carefully.