Below you will find brief information for Plasma Cutter PlasmaOne Premium Pilot. This manual explains the correct and safe use of your new PlasmaPart system. It covers important safety information like electric shock, fire and explosion hazards, hazardous gases and fumes, noise, and plasma arc ultraviolet radiation. The document also describes the setup, operation and connections needed to use the machine effectively. You will find information on troubleshooting common issues and contact details for customer support.

Key Features

  • Inverter plasma cutter
  • 40 Amps DC
  • Single Phase - 240V
  • HF Pilot arc striking
  • Duty Cycle 60%
  • P-80 Torch
  • Compressed air supply
  • Variable current control
  • Work piece clamp connection
  • Safety features

Pages: 15 PlasmaPart PlasmaOne Premium Pilot Manual

Brand: PlasmaPart Category: Do-It-Yourself tools Size: 960 KB

Languages: English

Open manual

Frequently Answers and Questions

How do I connect the compressed air supply?
Connect the compressed air supply to the rear of the machine using the PCL type quick air connection. Ensure the regulator is set to 70 PSI / 4.75 Bar when the air is flowing through the torch with the trigger pressed.
What safety precautions should I take when using the plasma cutter?
Always wear appropriate safety equipment such as eye protection, gloves, and respiratory protection. Ensure your work area is well ventilated and free from flammable materials.
What should I do if the arc goes out mid-way through a cut?
Check the air pressure, condition of the electrode and nozzle, mains plug connection, work piece clamp connection, torch euro connection, and the compressor and moisture trap on the rear of the machine.
What should I do if the arc does not initiate?
Check if the machine is switched on, has correct air supply, and work piece connection. Disassemble the torch consumables and check for worn electrode, loose electrode, missing or damaged swirl ring, and ensure correct matching consumables have been fitted.
What should I do if the cut is not clean?
Check the work piece clamp connection, condition of consumables, air pressure, and ensure there is no other material on the underside of the material being cut.
What should I do if the cut does not fully penetrate the material?
Check the work piece clamp connection, air pressure, current output setting, and ensure the material thickness is within the operating parameters of your machine.