Schneider Electric XBTF / TXBTF Graphic terminals (Tome 2)
Manuals and User Guides for Schneider Electric XBTF / TXBTF Graphic terminals (Tome 2). We found 1 manuals for free downloads User Guide
Pages: 302 Schneider Electric XBTF / TXBTF Graphic terminals (Tome 2) User Guide
Brand: Schneider Electric Category: Software Size: 8 MB
Languages: English
Table of contents
- 11 Terminals with keyboard
- 13 Touchscreen terminals
- 15 Terminals with touch keys
- 18 TXBT Terminals
- 23 Creating pages
- 24 Pages Types
- 26 Composition of the application pages
- 29 Accessing the application pages
- 30 Displaying the alarm list
- 30 Getting help
- 31 Recipe pages
- 32 Alarm indication from an application page
- 33 Composition of the alarm pages
- 34 Advantages of alarm pages
- 35 Group of alarms
- 36 Application region
- 36 Status line
- 36 Alarm strip
- 36 Screen HardcopiesTXBT
- 39 Static function keys
- 39 Dynamic function keys
- 41 TXBT
- 41 XBT
- 42 Data associated with the fields
- 43 Master or client terminal
- 43 Server or slave terminal
- 43 Principle of terminal "command and status" exchanges
- 46 Development hardware kit
- 46 Development software kit
- 46 Operating hardware kit
- 52 Phase 0: Control system structure
- 52 Phase 1: Commands from the terminal to the control system
- 52 Phase 2: Commands from the control system to the terminal
- 52 Phase 3: Design of pages
- 52 Phase 4: Dialog table
- 53 Phase 5: Model pages
- 53 Phase 6: Definition of application pages
- 54 Phase 7: Definition of alarm pages
- 54 Phase 8: Definition of help
- 54 Phase 9: Translations
- 55 Creating the application
- 56 Creating the equipment list
- 56 Configuration of alarms displays
- 57 Loading the PL7 or Concept symbols file
- 58 Base address
- 58 Composition of table
- 58 Cycle
- 58 Dialog table security
- 58 Alarm table
- 59 The main window
- 61 Position, alignment and grid
- 63 Text
- 64 Create graphics
- 65 Import images
- 66 Alphanumeric variable field
- 68 Bar-graph
- 70 Volume meter
- 70 Potentiometers
- 71 Switches
- 72 Image box
- 73 Graphical curve
- 75 Variable field characteristic
- 78 Function key objects
- 82 Model pages
- 83 Application/Alarm/Help/Recipe pages
- 93 Configuring a form page
- 95 Tree structure control
- 96 Field information window
- 99 Import/export texts
- 100 Import/export numbered list
- 101 Page number displayed by default at power up
- 102 Passwords
- 102 Default language
- 102 Date format to be used:
- 102 Time format to be used
- 102 Printer setup
- 102 Stand by screen display
- 105 Terminal simulation window
- 106 PLC simulation window
- 107 Local transfer
- 107 Remote transfer
- 108 Export operation
- 109 Import/export file
- 114 Data exchanged
- 116 Exchange principle for data associated with fields
- 117 Principle of the communications dialog table
- 119 Notation convention for describing the table
- 123 Detailed description
- 140 Processing by the terminal
- 141 Optimization for communication
- 142 Optimized communication
- 142 Non-optimized communication
- 148 Touchscreen terminals
- 152 Extra keys for TXBT
- 154 Basic Principle
- 156 Application transfer
- 157 Operating mode
- 160 Confidential mode, password management
- 164 Display at power up
- 167 Displaying a page using the directory of pages
- 168 Displaying a page using its number
- 168 Displaying a page by means of a dynamic function key, tactile zone or tactile key
- 169 Displaying a page by means of a static function key
- 170 Displaying a page using a word from the PLC
- 171 Displaying a system page by writing a public variable
- 172 For the XBT-Fs
- 172 For the TXBTs
- 173 Accessing a field
- 175 Field entry
- 176 Field Characteristics
- 180 Principle
- 181 Alarm page parameters
- 183 Alarm group
- 184 Display priority in the alarm list
- 186 Acknowledging alarms
- 187 Alarm relay command
- 188 Description of the alarm list
- 189 Alarm display by the PLC
- 190 Principle
- 191 Displaying the alarm history log
- 191 Clearing the alarm history log
- 192 Printing the alarm history log
- 192 Momentary contact command
- 193 Push on/Push off toggle command
- 194 Value direct writing
- 196 Startup with a Windows 95 command
- 197 Running using the Rx dynamic function keys
- 199 General
- 199 Print set-up
- 200 Stop printing
- 201 Continious printing of an alarm page
- 202 Printing the list of active alarms
- 203 Printing a form page
- 203 Printing the alarm Log
- 205 Free format printing
- 205 Printing of the product references
- 207 Terminal parameters
- 208 Parameters of the operations line
- 209 Printer line parameters
- 210 Principle
- 210 Accessible objects
- 211 Loading the PL7 symbols file
- 211 Access to adjustment
- 212 Procedure
- 214 Principle
- 214 Accessible objects
- 214 Access to adjustment
- 216 Creating or modifying the Adjustment page
- 227 Bread production consists of two operations
- 228 Installation maintenance
- 228 Management of production
- 229 Additional information
- 229 Navigating between the various screens
- 230 Process control
- 230 Maintenance
- 230 Locking the Kneader On/Off key
- 231 Application tree structure
- 232 Application tree structure balance
- 232 Main menu application page
- 233 Production Menu application page
- 233 Dough preparation application page
- 235 Dough baking application page
- 236 Maintenance page
- 237 Static function keys
- 237 Data associated with the application
- 238 Selecting the terminal and protocol
- 239 Creating the page model
- 242 Creating the various pages
- 244 Creating navigation between the application pages
- 246 Creating the page content
- 249 Assigning the static function keys
- 250 Locking the static function keys
- 251 Creating the dialog table
- 252 Alarm processing
- 255 Cancelling the entry
- 260 XBT-F 01
- 263 XBT-F 02
- 266 Touchscreen XBT-F 032
- 269 Touchscreen XBT-F 034
- 272 XBT-FC 02
- 275 XBT-FC 04
- 278 XBT-FC 08
- 281 XBT-FC 06
- 284 TXBT
- 287 System messages generated by XBT
- 288 System messages generated by XBT (5 languages), language selected during configuration.
- 290 No saving of value for objects set to error
- 290 Objects set to error not initialized
advertisement