Steamist TSG-AD
Manuali e guide per l'utente per Steamist TSG-AD. Abbiamo trovato 1 manuali per download gratuiti Installation instructions
Auto Drain TSG-AD is a valve that automatically drains the steam generator after each use. It is typically installed on steam generators that are equipped with an optional Auto Drain valve. The valve is normally closed and opens each time the steam generator drains. The valve is held closed throughout the steambath cycle and remains closed after the steambath or until the steam generator cools to about 120°F. To prevent damage to the home, do not operate the steam generator until the Auto Drain is fully piped to the drainage system.
Caratteristiche principali
- Automatic drainage
- Thermostatic switch prevents dumping boiling water
- Closed during steambath cycle
- Opens after steambath or when generator cools to 120°F
- Drains for 3 minutes total
- Flushed tank after 2.5 minutes
- Requires proper plumbing for drainage
- Must be tested for back up or splash
pagine: 2 Steamist TSG-AD Installation instructions
Marca: Steamist Categoria: Water heaters & boilers Dimensione: 181 KB
Lingue: English
Apri manualeRisposte e domande frequenti
How does the Auto Drain operate?
What is the purpose of the thermostatic switch?
How do I test the Auto Drain?
What are some important considerations for installing the Auto Drain?
annuncio pubblicitario