Tolon TTD28 is a device designed for monitoring and troubleshooting temperature-related issues in steam-based systems. It features a digital temperature measurement system that can be compared with manually measured temperatures to diagnose potential problems. By following the provided troubleshooting flowchart, users can identify and resolve various issues related to the temperature probe, connecting cable, and control panel (CP). This allows for efficient maintenance and ensures optimal performance of steam-based systems.

Key Features

  • Temperature Monitoring
  • Troubleshooting Flowchart
  • Digital & Manual Temperature Measurement
  • Temperature Probe Check
  • Cable Check
  • Control Panel Diagnosis

Pages: 1 Tolon TRDS16 User Instructions

Brand: Tolon Category: Measuring, testing & control Size: 85 KB

Languages: English

Open manual

Other manuals and documents

1 Pages

User Instructions

Languages: English

1 Pages

User Instructions

Languages: English

31 Pages

Parts Manual

1 Pages

User Instructions

Frequently Answers and Questions

What should I do if the temperature measurements differ between the digital and manual readings?
Replace the Temperature Probe (TP) first. If the issue persists, run a program to monitor the problem. Refer to the troubleshooting flowchart in the manual for detailed steps.
How do I check the cable connecting the control panel (CP) to the temperature probe (TP)?
The manual provides instructions on how to inspect the cable (3W1) for damage or malfunction. If the cable is found to be faulty, it needs to be replaced or repaired.
What if the cable is valid, but the problem persists?
If the cable is intact, it might indicate a fault with the control panel. In this case, the manual suggests sending the CP to the service for further diagnosis and repair.