United States Stove Company 5040 Owner's Manual


Add to my manuals
28 Pages

advertisement

United States Stove Company 5040 Owner's Manual | Manualzz

ECONOMY SERIES 5040

OWNER’S MANUAL

• WARNING: If your appliance is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

• PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death.

• Save these instructions.

UN

PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED

ITE U

D STATES STOV

S S

COMPANY

C E

United States Stove Company

227 Industrial Park Road

P.O. Box 151

South Pittsburg, TN 37380

852010

2 INTRODUCTION

Thank you for purchasing the US Stove Pellet Burning Stove, you are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you do all three.

PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.

Keep this manual handy for future reference.

This stove has been independently tested to ASTM E1509-04 Standard Specification for Room Heaters, Pellet Fuel Burning Type 1, ULC/ORD 1482-90 Standard for Solid Fuel Room Heaters, and Oregon Administrative Rules for Mobile Homes

(814-23-900 through 814-23-909) and Installation as a Stove Heater.

This pellet stove, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.

The authority having jurisdiction (such as municipal building department, fire department, fire prevention bureau, etc.) should be consulted before installation to determine the need to obtain a permit.

This appliance is designed specifically for use only with pelletized wood. It is designed for residential installation according to current national and local building codes as a freestanding room heater. It is also approved as a mobile home heater which is designed for connection to an outside combustion air source.

The stove will not operate using natural draft or without a power source for the blower systems and fuel feed system and must not be burned with any type of coal (see PROPER FUEL).

This stove is designed to provide the optimum proportions of fuel and air to the fire in order to burn free of smoke and soot.

Any blockage of the air supply to or from the stove will seriously degrade its performance and will be evidenced by a smoking exhaust and a sooting window. For best operation the ash content of the pellet fuel should be less than 1% and the calorific value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fill up the burn pot and eventually cut off the combustion air supply.

Commercial and industrial installations of these pellet stoves should not be used since operational control is often not well managed in these settings.

IMPORTANT INFORMATION

Model: __ 5040 ______

Style: ____________________________

Serial Number:_____________________

Purchase Date: ____________________

Purchased From:___________________

___________________

___________________

MAIL YOUR WARRANTY CARD TODAY

To receive full warranty coverage, you will need to show evidence of the date you purchased your stove. We suggest that you attach your sales invoice to this page, and fill in the form on the left, so that you will have all the information you need in one place should the need for service or information occur.

WARRANTY INFORMATION CARD

Name__________________________________________ Telephone #: (_____)_____________

City____________________________________________ State_______ Zip_________________

Email Address __________________________________________________________________

Model # of Unit________________________________ Serial #___________________________

Fuel Type: qWood q Coal qPellet q Gas q Other _________________________

Place of Purchase (Retailer)______________________________________________________

City____________________________________________ State_______ Zip_________________

If internet purchase, please list website address___________________________________

Date of Purchase _______________________________________________________________

Reason for Purchase: qAlternative Heat q Decoration q Cost q Main Heat Source q Other _________________________

What was the determining factor for purchasing your new appliance?_______

I have read the owner’s manual that accompanies this unit and fully understand the:

Installation q Operation q and Maintenance q of my new appliance.

Print Name Signature Date

Please attach a copy of your purchase receipt.

Warranty not valid without a Proof of Purchase.

Warranty information must be received within 30 days of original purchase.

Detach this page from this manual, fold in half with this page to the inside and tape together. Apply a stamp and mail to the address provided. You may use an envelope if you choose.

You may register online by going to www.usstove.com

All information submitted will be kept strictly confidential. Information provided will not be sold for advertising purposes.

Contact information will be used solely for the purpose of product notifications.

Ê

Fold Here

United States Stove Company

P.O. Box 151

South Pittsburg, TN 37380

Fold Here

É

PLACE

STAMP

HERE

Ө

Ө

Ө

Ө

Ө

Ө

Ө

Ө

SAFETY PRECAUTIONS

Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

Ө

Ө

3

Never try to repair or replace any part of the stove unless instructions are given in this manual. All other work should be done by a trained technician.

Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. Keep all such liquids well away from the stove while in use.

Never block free airflow through the open vents of the stove.

Keep foreign objects out of the hopper.

The stove will not operate during a power outage.

If an outage does occur, check the stove for smoke spillage and open a window if any smoke spills into the room.

Disconnect the power cord before performing any maintenance or repairs on the stove.

NOTE: Turning the stove “off” does not disconnect all power from the stove.

Ө

Ө

Ө

Ө

Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.

Do not place clothing or other flammable items on or near the stove.

The viewing door must be closed and latched during operation.

Do not operate the stove if the flame becomes dark and sooty or if the burnpot overfills with pellets. Turn the stove off, periodically inspect it, and call your dealer.

Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns. Educate all children of the danger of a high temperature stove. Young children should be supervised when they are in the same room as the stove.

During the start up period; 1) DO NOT open the viewing door; 2) DO NOT open the damper more than ¼”; 3) DO NOT add pellets to the burnpot by hand; 4) DO NOT use the Fuel Feed button (unless you are priming the auger after running out of pellets) as a dangerous condition could result.

Do not unplug the stove if you suspect a malfunction. Turn the stove off, periodically inspect it, and call your dealer.

Ө

If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine on the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of the sensors could then make the stove start on its own. It is recommended that the stove be unplugged when not in use for extended amounts of time (i.e. during the summer months).

Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this stove as well.

This unit must be properly installed to prevent the possibility of a house fire. The instructions must be strictly adhered to. Do not use makeshift methods or compromise in the installation.

Your stove requires periodic maintenance and cleaning. Failure to maintain your stove may lead to smoke spillage in your home.

This stove must be connected to a standard 120

V., 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug. Do not route the electrical cord underneath, in front of, or over the stove.

The exhaust system should be checked, at a minimum, at least twice a year for any build up of soot or creosote.

The exhaust system must be completely airtight and properly installed. The pellet vent joints must be sealed with RTV 500°F (260°C) silicone sealant, and with UL-181-AP foil tape.

Allow the stove to cool before carrying out any maintenance or cleaning. Ashes must be disposed in a metal container with a tight lid and placed on a no combustible surface well away from the home structure.

This stove is designed and approved for pelletized wood fuel only. Any other type of fuel burned in this heater will void the warranty and safety listing.

When installed in a mobile home, the stove must be bolted to the floor, have outside air, and NOT BE

INSTALLED IN A BEDROOM (Per H.U.D. requirements). Check with local building officials.

United States Stove Company grants no warranty, implied or stated, for the installation or maintenance of your stove, and assumes no responsibility of any consequential damage(s).

4 TABLE OF CONTENTS

INTRODUCTION ----------------------------------------------------------------------------------------------- 2

SAFETY PRECAUTIONS -------------------------------------------------------------------------------------- 3

SPECIFICATIONS ----------------------------------------------------------------------------------------------- 5

INSTALLATION ----------------------------------------------------------------------------------------------- 5

Preparation ----------------------------------------------------------------------------------------------- 5

Clearances ----------------------------------------------------------------------------------------------- 5

Combustion Air Supply ----------------------------------------------------------------------------- 6

When Outside Air Is Not Used -------------------------------------------------------------------- 6

Venting ----------------------------------------------------------------------------------------------- 6

Freestanding Installations ----------------------------------------------------------------------------- 7

Electrical Installation ----------------------------------------------------------------------------- 10

Special Mobil Home Requirements ----------------------------------------------------------- 10

OPERATION -------------------------------------------------------------------------------------------------------- 11

Panel Controls -------------------------------------------------------------------------------------- 11

Proper Fuel ----------------------------------------------------------------------------------------------- 12

Pre-Start-Up Check -------------------------------------------------------------------------------------- 12

Building a Fire -------------------------------------------------------------------------------------- 12

The HotRod™ Automatic Fire Starter ----------------------------------------------------------- 12

Damper Control -------------------------------------------------------------------------------------- 12

Opening Door

Room Air Fan

-------------------------------------------------------------------------------------- 12

-------------------------------------------------------------------------------------- 12

Re-Starting a Warm Stove ----------------------------------------------------------------------------- 13

If Stove Runs Out Of Pellets -------------------------------------------------------------------- 13

Refueling ----------------------------------------------------------------------------------------------- 13

US Stove Maintenance Tool

Shutdown Procedure

-------------------------------------------------------------------- 13

----------------------------------------------------------------------------- 13

Safety Features -------------------------------------------------------------------------------------- 13

Optional Thermostat ----------------------------------------------------------------------------- 14

Thermostat Installation ----------------------------------------------------------------------------- 14

(Please Read This) Operating Safety Precautions ----------------------------------------- 15

MAINTENANCE ----------------------------------------------------------------------------------------------- 16

Ash Removal ----------------------------------------------------------------------------------------------- 16

Ash Disposal ----------------------------------------------------------------------------------------------- 16

Vacuum Use ----------------------------------------------------------------------------------------------- 16

Cleaning ----------------------------------------------------------------------------------------------- 16

Blowers ----------------------------------------------------------------------------------------------- 17

Chimney Cleaning -------------------------------------------------------------------------------------- 18

Recommended Maintenance Schedule ----------------------------------------------------------- 18

Removal & Replacement of Broken Door Glass -------------------------------------------------- 18

TROUBLE SHOOTING GUIDE ----------------------------------------------------------------------------- 19

Smoke Smell or Soot Build-Up -------------------------------------------------------------------- 24

ELECTRICAL DIAGRAM --------------------------------------------------------------------------------- ----- 25

REPLACEMENT PARTS LIST ----------------------------------------------------------------------------- 26

INSTALLATION

SPECIFICATIONS

FREESTANDING:

Width: 21 ½”

Height: 28 ½” (with legs or pedestal)

Depth: 24”

Weight: 185 lbs.

Pedestal: 40 lbs.

Legs: 13 lbs.

Flue size: 3” or 4”

Hopper Capacity: Up to 45 lbs.

(this can vary widely depending on pellet size, length, and diameter)

EPA status: exempt

Burn time: 1 lb. to 4 ½ lbs. per hour

BTU range: 8,200 to 40,000

Approved installations: mobile home, alcove, conventional

BACKWALL

8 1/4”

(TOP)

9”

(SIDEWALL)

* 1”

PREPARATION

Factory packaging must be removed, and some minor assembly work is required prior to installation. Access to the rear of the stove is necessary.

The circuit board/control panel must be unpacked and installed in the side flashing on the insert or side panel on the freestanding. (See installation instructions provided with the circuit board)

NOTE: Normally, your dealer will perform these functions.

CLEARANCES

This freestanding appliance has been tested and listed for installation in residential, mobile home and alcove applications.

48” MIN.

SIDEWALL CLEARANCES

36” MAX.

3”

WITH

VERTICAL

EXHAUST

FIGURE 1

ADJACENT WALL

1”

3”

3”

1”

5

*

WITH HORIZONTAL EXHAUST

38” MIN.

BACKWALL

WITH

VERTICAL

EXHAUST

8 1/4”

(TOP)

3”

1” *

8 1/4”

(TOP)

9”

(SIDEWALL)

9”

(SIDEWALL)

FLOOR PROTECTION: Freestanding installations, minimum 21” wide by 28” deep. The stove must be placed on a continuous (grouted joints) noncombustible material such as ceramic tile, cement board, brick, 3/8” millboard or equivalent, or other approved or listed material suited for floor protection.

THE MATERIAL(S) USED MUST HAVE, OR COMBINE TO HAVE, A

MINIMUM INSULATIVE RATING OF ‘R1’.

NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to prevent the possibility of embers falling through to the combustible floor if cracks or separation should occur in the finished surface, this would include floor protection for Built-in raised hearths. Check local codes for approved alternatives.

Clearances are measured from the sides, back and face (door opening) or stove body (refer to fig. 4).

DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN

THE INSTALLATION OF THIS UNIT.

INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT

MANUFACTURER .

STOVE DOOR FACE MUST BE

EQUAL TO OR PROTRUDE OUT

FROM FACE OF ALCOVE.

ALCOVE CLEARANCES

FIGURE 2

21”

28”

6”

FLOOR PROTECTION

FIGURE 4

6

COMBUSTION AIR SUPPLY

INSTALLATION

For a mobile home installation the stove must be connected to an outside source of combustion air. A 2” inside diameter metallic pipe, either flexible or rigid, may be attached to the inlet at the stove’s rear (refer to figure 5a.) A rodent guard (minimum ¼” wire mesh)/ wind hood must be used at the terminus (refer to figure 7). All connections must be secured and airtight by either using the appropriately sized hose clamp and/or UL-181-AP foil tape.

EXHAUST

PIPE

For mobile home installations only: 2” inside diameter pipe may be used for the first 5 feet of combustion air supply run. From 5 to

10 feet use 2 ¾” inside diameter pipe. No combustion air supply may exceed 10 feet.

11”

5 7/8”

Sources of Outside Combustion Air a. For freestanding installations

• A hole in floor near stove rear terminating only in a venti

lated crawl space.

• A hole in the wall behind the stove.

WHEN OUTSIDE AIR IS NOT USED

If outside air is not used, it is important that combustion air is easily available to the air inlet. A closeable outside air register can be used in tightly insulated homes. In insert installations, flashing vents should not be restricted. The flashing should not necessarily seal the fireplace face.

VENTING

This freestanding appliance is certified for use with listed TYPE L-

Vent, 3” or 4” diameter in size. The stove was tested with Simpson

Duravent brand. Class “A” chimney is not required. Refer to the instructions provided by the vent manufacturer, especially when passing through a wall, ceiling or roof.

This is a pressurized exhaust system. All vent connector joints must be sealed with 500 O F (260 O C) RTV silicone sealant to ensure consistent performance and avoid smoke spillage. All horizontal connector joints must be sealed with UL-181-AP foil tape. We recommend that all vertical vent connector joints be secured with a minimum of 3 screws.

It is strongly recommended that you have a minimum of 6’ of vertical pipe in your exhaust system. For best performance of the stove limit the number of elbows and horizontal pipe as much as possible.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING

ANOTHER APPLIANCE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING

SYSTEM OF THIS UNIT.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANU-

FACTURER.

28 1/2”

21 1/2”

6 1/2”

FIGURE 5a

24 3/4”

VENTILATED

CRAWL SPACE

FIGURE 7

AIR

INLET

PIPE 28 1/2”

10 3/4”

TRIM

COLLAR

RODENT

GUARD

INSTALLATION

Equivalent Vent Length (EVL)

The longer the run of pipe in your installation (both with inserts and freestandings), the more restriction there is in the system.

Therefore, larger diameter pipe should be used.

• Use 4” pipe if you have more than 15 feet of equivalent vent length.

• Horizontal runs shall not exceed 10 feet of EVL.

• It is recommended that vertical runs be a minimum of 8 feet.

• To calculate EVL, use the following conversions:

90º elbow or “T”

45º elbow

= 5 equivalent feet

= 3 equivalent feet

Horizontal Pipe Run = 1 equivalent foot per actual foot

Vertical Pipe Run = 0.5 equivalent foot per actual foot

NOTE: At altitudes above 3,000 feet, we suggest the use of

4” diameter vent at an EVL of 7 feet or more.

B. HORIZONTALLY THROUGH WALL (refer to Figure 9)

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1. Position stove, adhering to clearances shown in Figures

1 & 2.

2. Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 5).

3. Always maintain 3” clearance from combustible materials.

4. Install L-Vent wall thimble per L-Vent manufacturer’s instructions.

5. Attach enough piping to penetrate and extend at least 6” beyond exterior walls. An 8-foot vertical pipe run is suggested where possible to reduce the possibility of smoke spillage in the event of a loss of negative pressure.

6. Attach cap and seal outside wall thimbles with nonhardening waterproof mastic.

7. Termination should not be located so that hot exhaust gases can ignite trees, shrubs, or grasses or be a hazard to children. Exhaust gases can reach temperatures of

500ºF and cause serious burns if touched.

WALL

THIMBLE

L-VENT

ADAPTER

TO

APPLIANCE

7

WALL STRAP

SEE VENT MANUFACTURER

FOR NUMBER AND SPACING

6” MINIMUM CLEARANCE

TO ANY COMBUSTIBLE

SURFACE

CLEAN-OUT TEE

A 90 DEGREE ELBOW

MAY ALSO BE USED

6” MINIMUM CLEARANCE

FIGURE 9

Locate terminations: a) not less than 3 feet above any forced air inlet located within 10 feet; b) not less than 4 feet below or horizontally from, or one foot above, any door, window or gravity air inlet into any building; c) not less than two feet from an adjacent building and not less than 7 feet above grade when located adjacent to a public walkway. Mobile home installations must use a spark arrester.

8 INSTALLATION

C. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 10)

NOTE: Follow L-Vent chimney manufacturer’s instructions.

OPTION: To achieve a center vertical installation a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove.

3” MINUMUM

CLEARANCES TO

COMBUSTIBLES OPTION: Install L-Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark point on ceiling. Install ceiling support and L-Vent pipe per

L-Vent manufacturer’s instructions.

12” MINIMUM CLEARANCE

TO ROOF

VERTICAL ROOF VENT

ATTIC

INSULATION

SHIELD

3” MINUMUM

CLEARANCES TO

COMBUSTIBLES

1. Always maintain 3” clearance from combustible materials. When passing through additional floors or ceilings, always install firestop spacer.

2. After lining up for hole in roof, cut either a round or square

hole in roof, always 3” larger all the way around pipe.

Install upper edge and sides of flashing under roofing materials, nail to the roof along upper edge. Do not nail lower edge. Seal nail heads with non-hardening waterproof mastic.

TO

APPLIANCE

3. Apply non-hardening, waterproof mastic where the storm

collar will meet the vent and flashing. Slide storm collar down until it sits on the flashing. Seal and install cap.

Mobile home installations must use a spark arrester.

D. VERTICALLY INTO EXISTING CHIMNEY SYSTEM

Adapters are available to adapt from 3” L-Vent to 6” or 8”

Class-A chimney. (Figure 11a)

As an alternative, 3” or 4” L-Vent can be run inside existing chimney to termination. (Figure 11b)

This is the preferred method.

Follow guidelines for equivalent vent length.

CLEANOUT

TEE

FIGURE 10

EXISTING

CHIMNEY

SYSTEM

PELLET VENT TO

CHIMNEY ADAPTER

(SPV-CA)

UNIVERSAL

CONNECTOR

FIGURE 11a

45 DEGREE ELBOW

EXISTING

CHIMNEY

SYSTEM

PELLET

VENT

NOTE:

THIS METHOD

IS PREFERRED

FIGURE 11b

INSTALLATION

E. VERTICALLY INTO EXISTING MASONRY FIREPLACE

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1. Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition.

2. You will need a pipe length equal to the chimney height

from the hearth. If outside combustion air is to be used,

you will need a pipe length equal to the chimney height

plus 18 inches.

3”

NOTE:

FOLLOW METAL

CHIMNEY INSTALLATION

INSTRUCTIONS

3. Install a blanking plate and the chimney pipe, and if used

the outside air pipe, as shown in Figure 12.

4. Attach the L-Vent adapter, a section of pipe and clean out tee, making sure the clean out tee is centered in the chimney flue area. Use RTV, metallic tape, and a minimum of three self-taping screws at all joint connections to ensure a tight seal.

5. Position the stove, adhering to the clearances in Figures

1 & 2.

TO

APPLIANCE

6” FROM STOVE

TO END OF HEARTH

6. Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe. Install and seal with non-hardening mastic to prevent water leakage.

Install vent cap.

F. INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1. Position the stove, adhering to the clearances in Figures

1 & 2. Mark the center of the hole where the pipe is to

pierce the masonry chimney.

2. It will be necessary to break out the masonry around the

location of the pipe center mark. Use a 4-inch diameter

hole for 3-inch pipe and 5-inch diameter hole for 4-inch

pipe.

3. Measure and build chimney top plate. Cut out holes for

chimney pipe, and if used the outside air pipe.

4. Install the tee on the bottom of the vertical pipe system and

lower it down the chimney until the center branch of the tee

is level with the center of the hole in the masonry, as shown

in Figure 13.

5. Install and seal the top plate from step 3 with non-hardening

mastic. Slip the storm collar over the pipe, and while holding

the pipe at the proper elevation, affix the collar with a mini-

mum of three ¼” stainless steel sheet metal screws. Seal all

joints and seams around the collar.

6. Connect the horizontal pipe by pushing it through the hole

in the masonry and lining it up with the branch in the tee.

Push the pipe into the tee while twisting it to lock it into the

tee.

7. If desired, once the horizontal pipe is in place, the space

between the pipe and masonry may be filled with high-

temperature grout.

8. Install the trim collar. An adjustable pipe length and adapter

may be needed to finish the connection to the stove.

NOTE:

FOLLOW METAL

CHIMNEY INSTALLATION

INSTRUCTIONS

3”

OPTIONAL OUTSIDE AIR

TRIM COLLAR

6”

HEARTH

6”

FIGURE 12

FIGURE 13

TOP PLATE

(SEAL TO CHIMNEY TOP

WITH NON-HARDENING

MASTIC)

OPTIONAL OUTSIDE AIR

CLEAN-OUT-TEE (TYPE L)

OR 90 DEGREE ELBOW

9

EXTENSION TO CHIMNEY TOP

REQUIRED.

3 OR 4 INCH STAINLESS STEEL

SINGLE WALL PIPE OR FLEX PIPE.

BLANKING PLATE (SEAL WITH

NON-HARDENING MASTIC).

3 OR 4 INCH STAINLESS STEEL

FLEX PIPE.

TOP PLATE

(SEAL TO CHIMNEY TOP

WITH NON-HARDENING

MASTIC)

EXTENSION TO CHIMNEY TOP

REQUIRED.

L-VENT OR OPTIONAL

3 OR 4 INCH STAINLESS STEEL

SINGLE WALL PIPE OR FLEX PIPE.

PIPE ADAPTER

CLEAN-OUT TEE (TYPE L)

10 INSTALLATION

E.

ELECTRICAL INSTALLATION

This stove is provided with a 6-foot grounded electrical cord extending from the rear of the stove. We recommend connecting to a good quality surge protector that is plugged into a standard three-prong, 120V,

60hz electrical outlet. Voltage variations can lead to serious performance problems. The electrical system is designed for 120V AC with no more than 5% variation. US

Stove cannot accept responsibility for poor performance or damage due to inadequate voltage. If connected to an older, two-prong outlet, a separate ground wire should be run to a proper ground (refer this to a qualified technician). Always route the electrical cord so that it will not come in contact with any hot part of the stove.

B

SECURE PEDESTAL TO FLOOR

WITH 2, 1/4” x 2” LONG

LAG BOLTS.

A

DRILL 2, 5/16” HOLES

IN PEDESTAL BASE.

FIGURE 21

SPECIAL MOBILE HOME REQUIREMENTS

WARNING: DO NOT INSTALL IN A SLEEPING ROOM.

NOTE: Installation should be in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24

For installation in a mobile home, an outside source of combustion air must be used (see “COMBUSTION AIR SUPPLY”).

This unit must be grounded to the steel chassis of the home with 8 Ga. copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding.

This unit must be securely fastened to the floor of the mobile home through the two holes in the rear of the stove using 2, ¼” lag bolts that are long enough to go through both a hearth pad, if used, and the floor of the home. (See figure 21)

Refer to “VENTING” for proper exhaust configurations.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.

OPERATION

PANEL CONTROLS (See Figure 22)

The blowers and automatic fuel supply are controlled from a panel on the left-hand side of this unit. The control panel functions are as follows.

a. ON/OFF SWITCH

• When pushed the stove will automatically ignite. No other firestarter is necessary. The

igniter will stay on for at least 10 and up to 15 minutes, depending on when Proof of Fire

is reached. The fire should start in about 5 minutes.

• The green light located above the On/Off button (in the On/Off box) will flash during the

ignition start-up period. (See figure 22)

• The Feed Rate Advance is inoperable during the ignition start period. When the red light

continuously stays on the Feed Rate Advance can be adjusted to achieve the desired

heat output.

NOTE: If the stove has been shut off, and you want to re-start it while it is still warm, the “on/ off” button must be held down for 2 seconds.

b. FUEL FEED SWITCH

• When the “Fuel Feed” button is pushed and held down the stove will feed pellets

continuously into the burnpot.

• While the stove’s auger system is feeding pellets the amber light (in the “Fuel Feed” box)

will be on. (See figure 22)

CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE IT

COULD SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUATION.

c. HIGH FAN SWITCH

• The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch overrides

this variable speed function. It will set the room air blower speed to high at any feed rate

setting.

• When the “HIGH FAN” button is pushed the room air fan will switch to its highest setting.

• When this button is pushed again the room air fan will return to its original setting based

on the Feed Rate Advance setting.

d. RESET TRIM

Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Feed

Rate Advance bar graph. This is usually a one-time adjustment based on the fuel you are

using. The “RESET TRIM” button when adjusted will allow for 3 different feed rate settings for the #1 feed setting only. To adjust simply push the “RESET TRIM” button while the stove is operating at setting “1” and watch the bar graph.

• When the “1” and “3” lights are illuminated on the bar graph the low feed rate is at its

“lowest” setting. (approx. 0.9 pounds per hour)

• When the “1” light is illuminated on the bar graph the low feed rate is at its “normal”

setting.

• When the “1” & “4” lights are illuminated on the bar graph the low feed rate is at its

“highest” setting.

NOTE: When the stove is set on “1” the “reset trim” values will be shown on the Feed Rate

Advance bar graph. For example if the Reset Trim is set to its lowest setting every time the stove is set to low the “1” and “3” lights will be illuminated on the bar graph.

e. HEAT LEVEL ADVANCE

• This button when pushed will set the pellet feed rate, hence the heat output of your stove.

The levels of heat output will incrementally change on the bar graph starting from level “1”

to “4”.

NOTE: When dropping more than 2 heat level settings (i.e. 4 to 1) push the ‘High Fan’ button and allow the room air fan to run at that setting for at least 5 minutes to prevent the stove from tripping the high temp thermodisc. If the high temp thermodisc does trip see “SAFETY

FEATURES”.

CAUTION: THE “4” SETTING IS DESIGNED FOR TEMPORARY USE ONLY. IF USED FOR

EXTENDED PERIODS, IT CAN SHORTEN THE LIFE EXPECTANCY OF THE UNITS COM-

PONENTS. AVOID USE AT THIS SETTING FOR MORE THAN ONE HOUR AT A TIME.

FIGURE 22

11

Reset Trim

High Fan

Fuel Feed

12

PROPER FUEL

OPERATION

THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void all warranties. The design incorporates automatic feed of the pellet fuel into the fire at a carefully prescribed rate. Any additional fuel introduced by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke. Do not burn wet pellets. The stove’s performance depends heavily on the quality of your pellet fuel.

Avoid pellet brands that display these characteristics:

a. Excess Fines – “Fines” is a term describing crushed pellets or loose material that looks like sawdust or sand. Pellets can be screened before being placed in hopper to remove most fines.

b. Binders – Some pellets are produced with materials to hold them together, or “bind” them.

c. High ash content – Poor quality pellets will often create smoke and dirty glass. They will create a need for more frequent maintenance. You will have to empty the burnpot plus vacuum the entire system more often. Poor quality pellets could damage the auger. US Stove cannot accept responsibility for damage due to poor quality pellets. Your dealer can recommend a good quality pellet dealer in your area.

PRE-START-UP CHECK

Remove burnpot, making sure it is clean and none of the air holes are plugged. Clean the firebox, and then reinstall burnpot. Clean door glass if necessary (a dry cloth or paper towel is usually sufficient). Never use abrasive cleaners on the glass or door. Check fuel in the hopper, and refill if necessary.

NOTE: The Hopper can hold up to 45 lbs. of pellets.

BUILDING A FIRE

Never use a grate or other means of supporting the fuel. Use only the US Stove approved burnpot.

During the start up period:

1) DO NOT open the viewing door.

2) DO NOT open the damper more than ¼”.

3) DO NOT add pellets to the burnpot by hand.

4) DO NOT use the Fuel Feed button (unless you are priming the auger after running out of pellets).

A dangerous condition could result.

NOTE: During the first few fires, your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal. Maintaining smaller fires will minimize this. Avoid placing items on stovetop during this period because paint could be affected.

THE HOTROD AUTOMATIC FIRESTARTER a. Fill hopper and clean burnpot.

b. Press “Power” button. Make sure light is on.

c. The damper should be completely closed or open no more than ¼” during start-up. This will vary depending on your installation and elevation. Once fire is established adjust for desired flame increasing the amount the damper is open as the heat setting is increased.

(See “DAMPER CONTROL”) d. Adjust feed rate to desired setting by pressing “Feed Rate Advance” button.

If fire doesn’t start in 15 minutes, press “Power”, wait a few minutes and start procedure again.

DAMPER CONTROL

The damper control rod on the stove’s lower left side adjusts the combustion air. This control is necessary due to the varied burn characteristics of individual installations, different pellet brands and pellet feed rates. It allows you to improve the efficiency of your stove. Providing correct combustion air will reduce the frequency of cleaning your glass door and prevent the rapid buildup of creosote inside your stove and chimney.

You should adjust the damper based on the fire’s appearance. A low, reddish, dirty fire can be improved by pulling the damper out slightly. A “blow torch” fire can be improved by pushing the damper in a bit.

As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper should be more open. Through trial and error, you will find the best setting. Consult your dealer if you need help.

NOTE: On “1”, damper should be either completely closed or out approximately ⅛” to ¼”. If damper is out too far, it can cause the fire to go out.

OPENING DOOR

If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down. If the stove shuts down push the “Power” button to continue the operation of your stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually takes about 10 minutes from startup.

OPERATION 13

RE-STARTING A WARM STOVE

If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.

IF STOVE RUNS OUT OF PELLETS

The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes.

After the stove components stop running the “Power” and the BAR GRAPH lights stay on for 10 minutes.

After the 10 minutes the “3” light on the bar graph will flash and the “Power” light will go off.

To restart, refill hopper, press “Power” button, and then press “Fuel Feed” button until pellets begin to fall into burnpot.

REFUELING

We recommend that you not let the hopper drop below ¼ full.

KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.

A tool has been provided to help with the following functions:

FIGURE 23 a. Stirring pellets in hopper – unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur.

Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help.

NOTE: To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper.

b. Cleaning heat exchanger tubes – see instructions in “CLEANING”.

c. Scrape ashes from burnpot.

SHUTDOWN PROCEDURE

Turning your stove off is a matter of pressing the “Power” control panel switch. The red light will go out. The blowers will continue to operate until internal firebox temperatures have fallen to a preset level.

SAFETY FEATURES a. Your stove is equipped with a high temperature thermodisc. This safety switch has two functions.

1. To recognize an overheat situation in the stove and shut down the fuel feed or auger system.

2. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing the stove from overheating.

NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove. On other units the thermodisc has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem. A service call may be required.

b. If the combustion blower fails, an air pressure switch will automatically shut down the auger.

NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air switch, shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove.

14 THERMOSTAT INSTALLATION

OPTIONAL THERMOSTAT

A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fixed wall mount or US Stove’s hand held model can be used. The control panel can be set up two ways to operate your stove in thermostat mode.

THERMOSTAT INSTALLATION

• A MILLIVOLT THERMOSTAT IS REQUIRED.

• Unplug stove from power outlet.

• Remove control board from stove.

• The two thermostat wires connect to the terminal block on the lower left

side of the back of the control board.

(See figure 24)

• Insert the wires in the terminal side and tighten the two screws.

MODES

TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE MUST

BE SHUT OFF, THE NEW MODE SELECTED, AND THE STOVE RESTART-

ED.

MANUAL MODE

• USE THIS MODE EXCLUSIVELY IF YOU DO NOT CONNECT AN OP-

TIONAL THERMOSTAT

• In this mode the stove will operate only from the control panel as detailed in the “OPERATION” section of this owner’s manual.

HIGH/LOW THERMOSTAT MODE

• USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT

• When engaged in this mode the stove will automatically switch between two settings. When warm enough, it will switch to the #1 or low setting.

The room air blower will also slow to its lowest speed.

• The Heat Level Advance setting on the bar graph will stay where it was initially set. When the house cools below the thermostat setting, the stove will switch to the feed rate of the heat level advance setting.

ON/OFF THERMOSTAT MODE

• USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT

• In this mode when the home is warm enough the stove will shut off. The fans will continue to run until the stove cools.

• When the home cools below the thermostat setting, the stove will automatically restart and run at the last feed rate setting.

FIGURE 24

NOTE: When in “high/low” or “on/off” thermostat mode –

• Do not operate the stove higher than the #3 setting.

• Set damper control rod approximately ¼” to ½” out. This will vary depending on elevation and weather conditions. Observe stoves operation and adjust damper as necessary.

OPERATION

OPERATING SAFETY PRECAUTIONS

PLEASE READ THIS!

a. Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns.

15

b. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup in firebox, immediately TURN OFF

the stove, but DO NOT unplug it. Do not open the door, change the damper setting or tamper with any controls on the stove.

Wait until firebox clears, and blowers shut down, do as instructed in “PRE-START-UP CHECK” and “BUILDING A FIRE”, then attempt to restart the fire. If the problem persists contact your dealer.

c. WARNING: DO NOT ADD PELLETS TO THE BURNPOT BY HAND AT ANY TIME, A DANGEROUS CONDITION COULD RESULT. d. WARNING: DURING THE START UP CYCLE; 1) DO NOT OPEN THE VIEWING DOOR; 2) DO NOT OPEN THE DAMPER MORE

THAN ¼”; 3) DO NOT USE THE FUEL FEED BUTTON (UNLESS PRIMING THE AUGER AFTER RUNNING OUT OF PELLETS). A

DANGEROUS CONDITION COULD RESULT.

e. Pellets should be stored in a dry place. The pellets should not be stored within 12” of the stove.

f. DO NOT STORE OR USE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, IN THE VICINITY OF YOUR STOVE. NEVER USE

A GAS OR PROPANE TORCH, GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR

SIMILAR FLUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER.

g. WARNING: DO NOT OVERFIRE THIS STOVE. This may cause serious damage to your stove and void your warranty. It also may create a fire hazard in your home. IF ANY EXTERNAL PART OF THE UNIT BEGINS TO GLOW, YOU ARE OVERFIRING. Immediately press the “POWER” switch on the control panel.

h. KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES, SUCH AS FURNITURE, DRAPES, TOYS, ETC. AT LEAST

THREE FEET FROM THE OPERATING STOVE.

i. Maintain proper ventilation. It is important that adequate oxygen be supplied to the fire for the combustion process. Modern houses are often so well insulated that it may become necessary to open a window slightly or install an outside air vent to provide sufficient combustion air.

j. Since heating with a solid fuel is potentially hazardous, even with a well made and thoroughly tested stove, it would be wise to install strategically placed smoke detectors and have a fire extinguisher in a convenient location, near an exit.

k. Do not open stove door when operating unless necessary. This will create a dirty, inefficient burn and could allow smoke spillage or sparks to escape.

l. Do not permit operation by young children or those unfamiliar with stove’s operation.

m. Do not service or clean this appliance without disconnecting the power cord.

n. Do not abuse the door glass by striking, slamming or similar trauma. Do not operate the stove with the glass removed, cracked or broken.

o. If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine on the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of the sensors could then make the stove start on its own. It is recommended that the stove be unplugged when not in use for extended amounts of time (i.e. during the summer months).

16 MAINTENANCE

FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN

RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER

CLEAN WHEN HOT.

NOTE: Inspect burn pot periodically to see that holes have not become plugged, if so, clean thoroughly.

ASH REMOVAL

Ashes should be placed in a metal container with a tight-fitting lid. The closed container or ashes should be placed on a noncombustible surface or on the ground, well away from all combustible materials pending final disposal.

If ashes are disposed of by soil burial or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.

ASH DISPOSAL

Remove ashes periodically as they fill the firebox. To remove ashes: a. Make sure fire is out and firebox is cool.

b. Clean heat exchanger tubes (see “CLEANING” and Figure 25).

c. Remove the burnpots inner section by grasping it and pulling straight up

(see Figure 26).

d. Empty ashes from the inner section and scrape with cleaning tool; make sure holes are not plugged.

e. Vacuum to remove ashes from the burn chamber interior and the burnpot shell.

WARNING: Make sure ashes are cool to the touch

before using a vacuum. See f. Dispose of ashes properly. (See

“VACUUM USE”.

“ASH REMOVAL” above) a. Replace inner section into burnpot; make sure it is level and pushed all the way back down and that the igniter hole is to the rear when it is reinstalled (see Figure 26).

b. Make sure the burnpot is level and pushed all the way in, if the collar on the burnpot attached to the fresh air tube is not pushed back to meet the firebox wall, the Hot Rod will not work properly.

VACUUM USE

If a vacuum is used to clean your unit, we suggest using a vacuum designed for ashes. (We recommend LoveLess Ash Vac, 1-800-568-3949 Ext. #27)

Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage.

CLEANING a. Heat Exchange Tubes – Your stove is designed with a built-in heat exchange tube cleaner. This should be used every two or three days to remove accumulated ash on the tubes, which reduces heat transfer on this unit. Insert the handle end (with hole) of the cleaning tool onto the cleaning rod (refer to figure 25). The cleaner rod is located in the grill above the stove door. Move the cleaner rod back and forth several times to clean the heat exchanger tubes. Be sure to leave tube cleaner at the rear of the stove.

b. Interior Chambers – Four ash doors and two upper baffles, in the firebox of this unit, can be removed for periodic cleaning (Figure 27). These doors allow access to the chamber surrounding the firebox.

NOTE: When removing the upper baffles do not remove the screws; just loosen them enough to allow the baffles to be removed.

Periodically, you must vacuum ashes from this chamber. In some cases you will need to remove creosote, which can accumulate rapidly under certain conditions. A small wire brush can be used. It is important to remove this creosote because it is highly combustible. INSPECT BEHIND THESE CLEAN-

ING PLATES AT LEAST ONCE PER TON OF PELLETS BURNED UNTIL

YOU ARE FAMILIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE

WITH YOUR OPERATING PRACTICES. Use the small wire brush to also clean the inside of the chamber walls, above the access doors.

CLEANING

ROD

CLEANING

TOOL

FIGURE 25

FIGURE 26

FIGURE 27

MAINTENANCE

BLOWERS

DANGER: RISK OF ELECTRIC SHOCK. DISCON-

NECT POWER BEFORE SERVICING UNIT.

Cleaning – Over a period of time, ashes or dust may collect on the blades of both the combustion blower and convection blower. Periodically the blowers should be vacuumed clean as these ashes can impede performance. Creosote can also accumulate in the combustion blower. This needs to be brushed clean. The convection blower is accessed by removing the stove’s left side panel. The combustion blower can be accessed by removing the stove’s right side panel. The convection blower is on the left (facing stove), and the combustion blower is on the right.

Combustion

Blower

(A-E-027)

Auger Motor

(C-E-017)

NOTE: When cleaning, be careful not to dislodge balancing clip on convection blower or to bend fan blades. Some stove owners lightly spray an anti-creosote chemical on the fire to help reduce creosote formation within the stove.

Convection

Blower

(A-E-033)

FIGURE 28

High Temp

Thermodisc

(C-E-090-21)

Air Switch

(C-E-200)

17

Auger Shaft

(A-AUG-22)

Combustion

Blower

(A-E-027)

POF

Thermodisc

(C-E-090-22C)

Pellet

Hopper

Air Inlet

Tube

FIGURE 29

18

CHIMNEY CLEANING

MAINTENANCE

a. Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a newly started fire or from a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire, which may damage the chimney or even destroy the house. Despite their high efficiency, pellet stoves can accumulate creosote under certain conditions.

b. Soot and Fly Ash: Formation and Need for Removal - The products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least once every year or ton of pellets burned to determine if cleaning is necessary.

c. Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or fly ash build-up has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire. Inspect the system at the stove connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as well as from the bottom.

The creosote should be removed with a brush specifically designed for the type of chimney in use. A qualified chimney sweep can perform this service. It is also recommended that before each heating season the entire system be professionally inspected, cleaned and, if necessary, repaired.

To clean the chimney, detach the vent at the combustion blower transition where it is attached to the blower.

RECOMMENDED MAINTENANCE SCHEDULE

Use this as a guide under average-use conditions.

Burn Pot

Glass

Combustion Chamber

Ashes

Interior Chambers

Heat Exchange Tubes

Combustion Blower Blades

Convection Blower Impeller

Vent System

Gaskets

Hopper (end of season)

Daily

Stirred

Wiped

Weekly

Emptied

Cleaned

Brushed

Two passes

Annually or per Ton

Emptied

Vacuumed

Vacuumed / Brushed

Vacuumed / Brushed

Cleaned

Inspected

Emptied and vacuumed

Gasket around door and door glass should be inspected and repaired or replaced when necessary.

(See “REPLACEMENT PARTS”)

REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS

While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the doorframe. Dispose of all broken glass properly. Return the damaged door to your US Stove Dealer for repair or replacement.

Neither the appliance owner nor any other unauthorized person(s) should replace the door glass. An authorized US Stove dealer must perform all repairs involving door glass.

TROUBLESHOOTING GUIDE 19

When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 1) poor fuel;

2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5. Refer to diagrams on page 20 to help locate indicated parts.

For the sake of troubleshooting and using this guide to assist you, you should look at your heat level setting to see which light is flashing.

** CAUTION – UNPLUG THE STOVE FROM ALL POWER PRIOR TO ATTEMPTING TO SERVICE THE UNIT! **

STOVE SHUTS OFF AND THE #2 LIGHT FLASHES

Possible Causes:

1. Airflow switch hose or stove attachment pipes

for hose are blocked.

2. The air inlet, burnpot, interior combustion air

chambers, combustion blower, or exhaust

pipe are blocked with ash or foreign material.

3. The firebox is not properly sealed.

Possible Remedies:

Unhook air hose from the air switch and blow through it. If air flows freely, the hose and tubes are fine. If air will not flow through the hose, use a wire coat hanger to clear the blockage.

Follow all clearing procedures in the maintenance section of the owner’s manual.

4. Vent pipe is incorrectly installed.

5. The airflow switch wire connections are bad.

6. The gray wires are pulled loose at the Molex

connector on the wiring harness.

7. Combustion blower failure

8. Control board not sending power to combus-

tion blower.

9. Control board not sending power to air

switch.

10. Air switch has failed (very rare).

Make sure the door is closed and that the gasket is in good shape. If the ash door has a latch, make sure the ash door is properly latched and the gasket is sealing good. If the stove has just a small hole for the ashes to fall through under the burnpot, make sure the slider plate is in place to seal off the firebox floor.

Check to make sure vent pipe installation meets criteria in owner’s manual.

Check the connectors that attach the gray wires to the air switch.

Check to see if the gray wires are loose at the

Molex connector.

With the stove on, check to see if the combustion blower is running. If it is not, you will need to check for power going to the combustion blower. It should be a full current. If there is power, the blower is bad. If there is not, see #8.

If there is no current going to the combustion blower, check all wire connections. If all wires are properly connected, you have a bad control board.

There should be a 5-volt current (approximately) going to the air switch after the stove has been on for 30 seconds.

To test air switch, you will need to disconnect the air hose from the body of the stove. With the other end still attached to the air switch, very gently suck on the loose end of the hose (you may want to remove the hose entirely off the stove and the air switch first and make sure it is clear). If you hear a click, the air switch is working.

BE CAREFUL! TOO MUCH VACUUM CAN DAMAGE

THE AIR SWITCH.

20 TROUBLESHOOTING GUIDE

STOVE SHUTS OFF AND THE #3 LIGHT FLASHES

Possible Causes:

1. The hopper is out of pellets.

2. The air damper is too far open for a low feed

setting.

3. The burnpot is not pushed completely to the

rear of the firebox.

4. The burnpot holes are blocked.

5. The air inlet, the interior chambers, or exhaust

system has a partial blockage.

6. The hopper safety switch has failed or hopper

s open.

7. The auger is jammed.

8. The auger motor has failed.

9. The Proof of Fire (POF) thermodisc has

malfunctioned.

10. The high limit thermodisc has tripped or is

defective

11. The fuse on the control board has blown.

12. The control board is not sending power to the

POF thermodisc or other auger system

components.

Possible Remedies: (Unplug stove first when possible)

Refill the hopper

If burning on the low setting, you may need to close the damper all the way (push the knob in so it touches the side of the stove).

Make sure that the air intake collar on the burnpot is touching the rear wall of the firebox.

Remove the burnpot and thoroughly clean it.

Follow all cleaning procedures in the maintenance section of the owner’s manual.

When operating the unit, be sure the hopper lid is closed so that the hopper safety switch will activate. Check the wires leading from the hopper safety switch to the control panel and auger motor for secure connections. Use a continuity tester to test the hopper safety switch, replace if necessary.

Start emptying the hopper. Then remove the auger motor by removing the auger pin. Remove the auger shaft. Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing. Next, remove the two nuts that hold the top auger biscuit in. Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove. After you have removed the shaft, inspect it for bent flights, burrs, or broken welds. Remove any foreign material that might have caused the jam. Also, check the auger tube for signs of damage such as burrs, rough spots, or grooves cut into the metal that could have caused a jam.

Remove the auger motor from the auger shaft and try to run the unit. If the motor will turn, the shaft is jammed on something. If the motor will not turn, the motor is bad.

Temporarily bypass the POF thermodisc by disconnecting the two brown wires and connecting them with a short piece of wire. Then plug the stove back in. If the stove comes on and works, you need to replace the POF thermodisc. This is for testing only. DO NOT LEAVE THE THERMODISC BY-

PASSED. Your blowers will never shut off and if the fire went out, the auger will continue to feed pellets until the hopper is empty if you leave the POF thermodisc bypassed.

Wait for the stove to cool for about 30-45 minutes. It should now function normally. If not, use the owner’s manual to locate the high limit thermodisc. To test if the thermodisc is bad, you can bypass it as described previously for the POF thermodisc.

Remove the control board. On the back, there is one fuse. If it appears to be bad, replace it with a 5 Amp 125 Volt fuse. Plug the stove back in and try to run the unit.

There should be a 5-volt (approximately) current going to the

POF thermodisc after the stove has been on for 10 minutes.

TROUBLESHOOTING GUIDE

STOVE FEEDS PELLETS, BUT WILL NOT IGNITE

Possible Causes:

1. Air damper open too far for ignition.

2. Blockage in igniter tube or inlet for igniter tube.

3. The burnpot is not pushed completely to the rear of

the firebox.

4. Bad igniter element.

The control board is not sending power to the igniter.

21

Possible Remedies:

Push the air damper in closer to the side of the stove for startup. In some situations, it may be necessary to have the damper completely closed for ignition to take place. After there is a flame, the damper can then be adjusted for the desired feed setting.

Find the igniter housing on the backside of the firewall. The air intake hole is a small hole located on the bottom side of the housing. Make sure it is clear. Also, look from the front of the stove to make sure there is not any debris around the igniter element inside of the igniter housing.

Make sure that the air intake collar on the burnpot is touching the rear wall of the firebox.

Put power directly to the igniter element. Watch the tip of the igniter from the front of the stove. After about 2 minutes, the tip should glow. If it does not, the element is bad.

Check the voltage going to the igniter during startup. It should be a full current. If the voltage is lower than full current, check the wiring. If the wiring checks out good, the board is bad.

SMOKE SMELL COMING BACK INTO THE HOME

Possible Causes:

1. There is a leak in the vent pipe system.

2. The gasket on the combustion blower has gone

bad.

Possible Remedies:

Inspect all vent pipe connections. Make sure they are sealed with RTV silicone that has a temperature rating of

500 o F or higher. Also, seal joints with UL-181-AP foil tape.

Also, make sure the square to round adapter piece on the combustion blower has been properly sealed with the same

RTV.

Inspect both gaskets on the combustion blower to make sure they are in good shape.

CONVECTION BLOWER SHUTS OFF AND COMES BACK ON

Possible Causes: Possible Remedies:

1. The convection blower is overheating and

tripping the internal temperature shutoff.

Clean any dust off the windings and fan blades. If clearing the blower does not help, the blower may be bad.

2. Circuit board malfunction.

Test the current going to the convection blower. If there is power being sent to the blower when it is shut off, the control board is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board.

22 TROUBLESHOOTING GUIDE

STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED

Possible Causes: Possible Remedies:

1. Fuse on control board blew.

Remove the control board. On the back, there is one fuse. If it appears to be bad, replace it with a 5 Amp 125 Volt fuse.

Plug the stove back in and try to run the unit.

2. High limit switch has tripped or is defective.

3. Bad auger motor.

Wait for the stove to cool for about 30-45 minutes. It should now function normally. If not, use the owner’s manual to locate the high limit thermodisc. To test if the thermodisc is bad, you can bypass it as described previously for the POF thermodisc.

Remove the auger motor from the auger shaft and try to run the unit. If the motor will turn, the shaft is jammed on something. If the motor will not turn, the motor is bad.

4. Auger jam

4. Loose wire or connector

5. Bad control board

Start by emptying the hopper. Then remove the auger motor by removing the auger pin. Remove the auger shaft inspection plate in the hopper so that you see the auger shaft.

Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing.

Next, remove the two nuts that hold the top auger biscuit in.

Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove. After you have removed the shaft, inspect it for bent flights, burrs, or broken welds. Remove any foreign material that might have caused the jam. Also, check the auger tube for signs of damage such as burrs, rough spots, or grooves cut into the metal that could have caused a jam.

Check all wires and connectors that connect to the auger motor, high limit switch, and the Molex connector.

If the fuse is good, the wires and connectors check out good, and the high limit switch did not trip, test fir power going to the auger motor. If there is not a full current going to the auger motor when the fuel feed light is on, you have a bad control board.

TROUBLESHOOTING GUIDE 23

GLASS “SOOTS” UP AT A VERY FAST RATE

FLAME IS LAZY, DARK AND HAS BLACK TIPS

AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS

Possible Cause:

1. Stove or vent pipe is dirty, which restricts airflow

through the burnpot.

Possible Remedies:

Follow all cleaning procedure in the maintenance section of the owner’s manual.

2. Vent pipe installed improperly.

3. Air damper is set too far in (closed) for a higher

setting.

4. Burnpot holes are blocked.

5. Air damper is broken.

Check to make sure the vent pipe has been installed according to the criteria in the owner’s manual.

Put the damper knob farther out away from the side of the stove and try not to burn the unit again.

Remove the burnpot and thoroughly clean it.

6. Blockage in air intake pipe.

7. Circuit board malfunction.

Visually inspect the damper assembly. Make sure the damper plate is attached to the damper rod. When the damper rod is moved, the plate should move with it.

Visually inspect the air intake pipe that leads into the burnpot for foreign material.

Time the fuel feed light at each setting (after the stove has completed the startup cycle). Make sure the times match the auger timing chart. If the auger motor runs constantly, the board is bad.

8. Combustion blower is not spinning fast enough.

9. Bad Pellets

(Applies to “GLASS ‘SOOTS’ UP AT A VERY

FAST RATE” only.

10. The trim setting on the low feed rate is too low.

(Applies to “GLASS ‘SOOTS’ UP AT A VERY

FAST RATE” only.

Test the RPM on the blower after the blades have been cleaned. The RPM should be approximately 3000RPM.

The brand of pellets or the batch of pellets that are being used may be of poor quality. If possible, try a different brand of pellets. You might also want to try a brand that is made from a different type of wood (softwood vs. hardwood).

Different woods have different characteristics when being burned.

Use the “Reset Trim” button to increase the low feed rate setting. If the “1” & “3” lights are on, the stove is currently on the lowest setting. If only the “1” light is on, the stove is in the default (medium) setting. If the “1” & “4” lights are on, the stove is in the high trim setting for the low feed rate. If the stove is being burned on one of the two lower settings, advance to the next trim setting and try burning the stove.

24 TROUBLESHOOTING GUIDE

HIGH LIMIT SWITCH KEEPS TRIPPING

Possible Causes:

1. The convection blower is overheating and tripping the

internal temperature shutoff.

2. The stove is being left on the highest setting for exten-

ded periods of time.

3. Fuel other than wood pellets is being burned in the stove.

4. Power surge or brown out situation.

5. High limit switch is malfunctioning.

Possible Remedies:

Clean any dust off the windings and fan blades. If oiling the blower does not help, the blower may be bad

The highest level setting is designated for use over short periods of time. Burning the stove on the highest setting for longer that 1-2 hours could lead to potential overheating situations.

United States Stove Company pellet stoves are designed and tested to use wood pellets. Check for signs of fuel other than wood pellets. No other type of fuel have been approved for United States Stove Company pellet stoves. If there are signs of other types of fuel being used, stop using them immediately.

A power surge, spike, or voltage drop could cause the high limit switch to trip. Check to see if a surge protector is being used on the stove. If not, recommend one to the consumer.

If the other items checked out ok, replace the high limit switch.

DIGITAL CIRCUIT BOARD TIMING RATES

Heat Level Setting BIG E

1 & 3 1.4 seconds

1

1 & 4

2

3

4

5

Total Cycle Time

2 seconds

2.5 seconds

4 seconds

7 seconds

9 seconds

12 seconds

14.5 seconds

SMOKE SMELL OR SOOT BUILD-UP

Because it is a wood-burning device, your appliance may emit a faint wood-burning odor. If this increases beyond normal or is you notice an unusual soot buildup on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed. Also, clean your stove following instructions in “ MAINTENANCE.” If problem persists, contact your dealer.

ELECTRICAL DIAGRAM

POWER SUPPLY

120 VOLTS AC

25

WHITE

PURPLE

BLACK

WHITE

ORANGE

ORANGE

BLUE

PINK

YELLOW

RED

GRAY

GRAY

WHITE

26 REPLACEMENT PARTS

Contact an Authorized US Stove Pellet Stove Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.

ITEM

AIR SWITCH

PART#

C-E-201

AIR SWITCH HOSE

AUGER MOTOR

MAINTENANCE TOOL

BURNPOT

CERAMIC BRICK PANEL SET - OPTIONAL

CERAMIC LOG SET (imitation) - OPTIONAL

CIRCUIT BOARD / CONTROL PANEL

COMBUSTION BLOWER

CONVECTION BLOWER

DAMPER KNOB

DOOR GASKET

DOOR GLASS

DOOR HANDLE

EXHAUST ADAPTER 4”

GOLD LEGS - OPTIONAL

HOT ROD IGNITER

HOPPER MICRO SWITCH

REMOTE THERMOSTAT (ACUMEN)-RF-OPTIONAL

THERMODISC, HIGH TEMP

THERMODISC, PROOF OF FIRE

C-E-901

AG-RCN

C-E-090-21

C-E-090-22C

WINDOW CLIPS, BOTTOM / AIRWASH

WINDOW CLIPS, SIDE

C-S-398

C-S-110

WINDOW GASKET (6’ - 1”) C-G-033

ZERO CLEARANCE LEGS (insert model only) - OPTIONAL A-S-ZCLEGS

C-M-340-T

C-E-017M

A-TOOL-96

A-S-BURNPOT

A-M-BRICK22

A-M-LOG

A-E-101

A-E-027J

A-E-033A

C-M-013

C-G-050

C-D-031

C-D-050

A-4-VA

A-CLG-22

C-E-IGN