United States Stove Company 5040 Owner's Manual

Add to My manuals
28 Pages

advertisement

United States Stove Company 5040 Owner's Manual | Manualzz

ECONOMY SERIES 5040

Golden

Eagle

5040

OWNER’S MANUAL

This unit is not intended to be used as a primary source of heat.

• WARNING: If your appliance is not properly installed a house

fi

re may result. For your safety, follow the installation directions. Contact local building or

fi

re of

fi

cials about restrictions and installation inspection requirements in your area.

• PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death.

• Save these instructions.

PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED

U.S. Environmental Protection Agency

Certi fi ed to comply with 2015 particulate emissions standards.

Manufactured by

United States Stove Company

227 Industrial Park Road

P.O. Box 151

South Pitsburg, TN 37380 www.USSTOVE.COM

6/2014

852010C-1909E

Thank you for purchasing the GoldenPellet Burning Stove, you are now prepared to burn wood in the most ef fi cient, convenient way possible. To achieve the safest, most ef fi cient and most enjoyable performance from your stove, you must do three things: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you do all three.

PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death.

Keep this manual handy for future reference.

This stove has been independently tested to ASTM E1509 Standard Speci fi cation for Room Heaters, Pellet Fuel Burning

Type 1, and ULC-S627 Standard For Space Heaters For Use With Solid Fuels.

This pellet stove, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.

The authority having jurisdiction (such as municipal building department, fi re department, fi re prevention bureau, etc.) should be consulted before installation to determine the need to obtain a permit.

This appliance is designed speci fi cally for use only with pelletized wood. It is designed for residential installation according to current national and local building codes as a freestanding room heater. It is also approved as a mobile home heater which is designed for connection to an outside combustion air source.

The stove will not operate using natural draft or without a power source for the blower systems and fuel feed system and must not be burned with any type of coal (see

PROPER FUEL

).

This stove is designed to provide the optimum proportions of fuel and air to the fi re in order to burn free of smoke and soot.

Any blockage of the air supply to or from the stove will seriously degrade its performance and will be evidenced by a smoking exhaust and a sooting window. For best operation the ash content of the pellet fuel should be less than 1% and the calori fi c value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fi ll up the burn pot and eventually cut off the combustion air supply.

Commercial and industrial installations of US Stove Pellet Stoves should not be used since operational control is often not well managed in these settings.

This manual describes the installation and operation of the Golden Eagle, 5040 wood heater. This heater meets the 2015

U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2015. Under speci fi c test conditions this heater has been shown to deliver heat at rates ranging from 6,569 to 34,785 Btu/hr.

Model:__________________________

IMPORTANT INFORMATION MAIL YOUR WARRANTY CARD TODAY

To receive full warranty coverage, you will need to show evidence of the date you purchased your stove. We suggest that you attach your sales invoice to this page, and

fi

ll in the form on the left, so that you will have all the information you need in one place should the need for service or information occur.

WARRANTY INFORMATION CARD

Name__________________________________________ Telephone #: (_____)_____________

City____________________________________________ State_______ Zip_________________

Email Address __________________________________________________________________

Model # of Unit________________________________ Serial #___________________________

Fuel Type:

Wood

Coal

Pellet

Gas

Other _________________________

Place of Purchase (Retailer)______________________________________________________

City____________________________________________ State_______ Zip_________________

If internet purchase, please list website address___________________________________

Date of Purchase _______________________________________________________________

Reason for Purchase:

Alternative Heat

Main Heat Source

Decoration

Cost

Other _________________________

What was the determining factor for purchasing your new appliance?_______

I have read the owner’s manual that accompanies this unit and fully understand the:

Installation



Operation

and

 of my new appliance.

Print Name Signature Date

Please attach a copy of your purchase receipt.

Warranty not valid without a Proof of Purchase.

Warranty information must be received within 30 days of original purchase.

Detach this page from this manual, fold in half with this page to the inside and tape together. Apply a stamp and mail to the address provided. You may use an envelope if you choose.

You may register online by going to www.usstove.com

All information submitted will be kept strictly confi dential. Information provided will not be sold for advertising purposes.

Contact information will be used solely for the purpose of product notifi cations.

Fold Here

United States Stove Company

P.O. Box 151

South Pittsburg, TN 37380

Fold Here

PLACE

STAMP

HERE

Ԧ

Ԧ

Ԧ

Ԧ

Ԧ

Ԧ

Ԧ

Ԧ

Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fl uid, or similar liquids to start or “freshen up” a fi re in this stove. Keep all such liquids well away from the stove while in use.

Never block free air fl ow through the open vents of the stove.

Keep foreign objects out of the hopper.

The stove will not operate during a power outage.

If an outage does occur, check the stove for smoke spillage and open a window if any smoke spills into the room.

Disconnect the power cord before performing any maintenance or repairs on the stove.

NOTE:

Turning the stove “off” does not disconnect all power from the stove.

During the start up period;

1) DO NOT

open the viewing door;

2) DO NOT

open the damper more than ¼”;

3) DO NOT

add pellets to the burnpot by hand;

4) DO NOT

use the Fuel Feed button (unless you are priming the auger after running out of pellets) as a dangerous condition could result.

Do not unplug the stove if you suspect a malfunction. Turn the stove off, periodically inspect it, and call your dealer.

Contact your local building of fi cials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this stove as well.

This unit must be properly installed to prevent the possibility of a house fi re. The instructions must be strictly adhered to. Do not use makeshift methods or compromise in the installation.

Your stove requires periodic maintenance and cleaning. Failure to maintain your stove may lead to smoke spillage in your home.

This stove must be connected to a standard 120

V., 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug. Do not route the electrical cord underneath, in front of, or over the stove.

The exhaust system should be checked, at a minimum, at least twice a year for any build up of soot or creosote.

Ԧ

Ԧ

Ԧ

Ԧ

Ԧ

Ԧ

Ԧ

Never try to repair or replace any part of the stove unless instructions are given in this manual. All other work should be done by a trained technician.

Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.

Do not place clothing or other fl ammable items on or near the stove.

The viewing door must be closed and latched during operation.

Do not operate the stove if the fl ame becomes dark and sooty or if the burnpot over fi lls with pellets. Turn the stove off, periodically inspect it, and call your dealer.

Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns. Educate all children of the danger of a high temperature stove. Young children should be supervised when they are in the same room as the stove.

If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine on the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of the sensors could then make the stove start on its own. It is recommended that the stove be unplugged when not in use for extended amounts of time (i.e. during the summer months).

The exhaust system must be completely airtight and properly installed. The pellet vent joints must be sealed with RTV 500°F (260°C) silicone sealant, and with UL-181-AP foil tape.

Allow the stove to cool before carrying out any maintenance or cleaning. Ashes must be disposed in a metal container with a tight lid and placed on a no combustible surface well away from the home structure.

This stove is designed and approved for pelletized wood fuel only. Any other type of fuel burned in this heater will void the warranty and safety listing.

When installed in a mobile home, the stove must be bolted to the fl oor, have outside air, and

NOT BE

INSTALLED IN A BEDROOM

(Per H.U.D. requirements). Check with local building of fi cials.

US Stove Hearth Products grants no warranty, implied or stated, for the installation or maintenance of your stove, and assumes no responsibility of any consequential damage(s).

5

SPECIFICATIONS

FREESTANDING:

Width: 21 ½”

Height: 28 ½” (with legs or pedestal)

Depth: 24”

Weight: 185 lbs.

Pedestal: 40 lbs.

Legs: 13 lbs.

Flue size: 3” or 4”

Hopper Capacity: Up to 45 lbs.

(this can vary widely depending on pellet size, length, and diameter)

EPA status: exempt

Burn time: 1 lb. to 4 ½ lbs. per hour

BTU range: 8,200 to 40,000

Approved installations: mobile home, alcove, conventional

PREPARATION

Factory packaging must be removed, and some minor assembly work is required prior to installation. Access to the rear of the stove is necessary.

The circuit board/control panel must be unpacked and installed in the side fl ashing on the insert or side panel on the freestanding. (See installation instructions provided with the circuit board)

NOTE: Normally, your dealer will perform these functions.

CLEARANCES

The US Stove 5040 Freestanding has been tested and listed for installation in residential, mobile home and alcove applications.

FLOOR PROTECTION: Freestanding installations, minimum 21” wide by 28” deep. The stove must be placed on a continuous (grouted joints) noncombustible material such as ceramic tile, cement board, brick, 3/8” millboard or equivalent, or other approved or listed material suited for fl oor protection.

THE MATERIAL(S) USED MUST HAVE, OR COMBINE TO HAVE, A MINIMUM

INSULATIVE RATING OF ‘R1’.

NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to prevent the possibility of embers falling through to the combustible fl oor if cracks or separation should occur in the fi nished surface, this would include fl oor protection for Built-in raised hearths. Check local codes for approved alternatives.

Clearances are measured from the sides, back and face (door opening) or stove body (refer to fi g. 4).

DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE IN-

STALLATION OF THIS UNIT.

INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT MANUFAC-

TURER.

CAUTION: DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY

AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR

SUCH INSTALLATIONS.

BACKWALL

8 1/4”

(TOP)

9”

(SIDEWALL)

48” MIN.

* 1”

SIDEWALL CLEARANCES

36” MAX.

3”

WITH

VERTICAL

EXHAUST

FIGURE 1

ADJACENT WALL

1”

3”

STOVE DOOR FACE MUST BE

EQUAL TO OR PROTRUDE OUT

FROM FACE OF ALCOVE.

ALCOVE CLEARANCES

28”

6”

FLOOR PROTECTION

3”

1”

*

WITH HORIZONTAL EXHAUST

38” MIN.

BACKWALL

3” WITH

VERTICAL

EXHAUST

8 1/4”

(TOP)

9”

(SIDEWALL)

1”

*

8 1/4”

(TOP)

9”

(SIDEWALL)

FIGURE 2

FIGURE 3

21”

6

COMBUSTION AIR SUPPLY

21 1/2”

If outdoor combustion air is supplied the heater must be attached to the structure.

For a mobile home installation the stove must be connected to an outside source of combustion air. A 2” inside diameter metallic pipe, either fl exible or rigid, may be attached to the inlet at the stove’s rear (refer to fi gures 5a and 6).

A rodent guard (minimum ¼” wire mesh)/wind hood must be used at the terminus (refer to fi gure 7). All connections must be secured and airtight by either using the appropriately sized hose clamp and/or UL-181-AP foil tape.

For mobile home installations only:

2” inside diameter pipe may be used for the fi rst 5 feet of combustion air supply run. From 5 to 10 feet use 2 ¾” inside diameter pipe. No combustion air supply may exceed 10 feet.

Sources of Outside Combustion Air

For freestanding installations

• A hole in fl oor near stove rear terminating only in a ventilated crawl

space.

• A hole in the wall behind the stove.

WHEN OUTSIDE AIR IS NOT USED

EXHAUST

PIPE

11”

EXHAUST

PIPE

5 7/8”

5 7/8”

6 1/2”

FIGURE 5a

21 1/2”

AIR

INLET

PIPE

28 1/2”

10 3/4”

AIR

INLET

PIPE

28 1/2”

If outside air is not used, it is important that combustion air is easily available to the air inlet. A closeable outside air register can be used in tightly insulated homes.

VENTING

11”

6 1/2”

10 3/4”

The US Stove 5040 Freestanding is certi fi ed for use with listed TYPE PL-Vent,

3” or 4” diameter in size. The stove was tested with Simpson Duravent brand.

Class “A” chimney is not required. Refer to the instructions provided by the vent manufacturer, especially when passing through a wall, ceiling or roof.

This is a pressurized exhaust system. All vent connector joints must be sealed with 500

O

F (260

O

C) RTV silicone sealant to ensure consistent performance and avoid smoke spillage. All horizontal connector joints must be sealed with

UL-181-AP foil tape. We recommend that all vertical vent connector joints be secured with a minimum of 3 screws.

28 1/2”

It is strongly recommended that you have a minimum of 6’ of vertical pipe in your exhaust system. For best performance of the stove limit the number of elbows and horizontal pipe as much as possible.

A chimney connector shall not pass thorough an attic or roof space, closet or similar concealed space, or a fl oor, or ceiling. Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365, installation code for solid-Fuel-Burning appliances and equipment.

IMPORTANCE OF PROPER DRAFT

FIGURE 5b

24 3/4”

VENTILATED

CRAWL SPACE

TRIM

COLLAR

FIGURE 7

RODENT

GUARD

Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance. Inadequate draft may cause backpuf fi ng into the room and ‘plugging’ of the chimney.

Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints.

An uncontrollable burn or excessive temperature indicates excessive draft.

Take into account the chimney’s location to insure it is not too close to neighbors or in a valley which may cause unhealthy or nuisance conditions.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

7

Equivalent Vent Length (EVL)

The longer the run of pipe in your installation, the more restriction there is in the system. Therefore, larger diameter pipe should be used.

• Use 4” pipe if you have more than 15 feet of equivalent vent length.

• Horizontal runs shall not exceed 10 feet of EVL.

• It is recommended that vertical runs be a minimum of 8 feet.

• To calculate EVL, use the following conversions:

90º elbow or “T”

45º elbow

= 5 equivalent feet

= 3 equivalent feet

Horizontal Pipe Run = 1 equivalent foot per actual foot

Vertical Pipe Run = 0.5 equivalent foot per actual foot

NOTE: At altitudes above 3,000 feet, we suggest the use of

4” diameter vent at an EVL of 7 feet or more.

FREESTANDING INSTALLATIONS

A. ASSEMBLING PEDESTAL OR LEG SET

If using a pedestal, follow the instructions inside the US Stove

5040 Pedestal Set Part # A-22-P (refer to fi gure 8).

If using cast legs, follow the instructions inside the US Stove

5040 Leg Set Part # A-CGL-22 or # A-CL-22.

Legs are installed by using the four bolts provided in the kit into the four holes under the stove at each corner, thread on nuts from the top and tighten. Make sure to save the hole plugs.

FIGURE 8

VERTICAL ROOF VENT

NOTE:

If converting from legs to pedestal the hole plugs must be installed in the unused holes.

B. HORIZONTALLY THROUGH WALL

(refer to Figure 9)

NOTE:

Follow PL-Vent chimney manufacturer’s instructions.

1. Position stove, adhering to clearances shown in Figures

1 & 2.

2. Locate position of hole in wall; directly behind stove exhaust vent (refer to fi gure 5).

3. Always maintain 3” clearance from combustible materials.

WALL

THIMBLE

L-VENT

ADAPTER

TO

APPLIANCE

WALL STRAP

SEE VENT MANUFACTURER

FOR NUMBER AND SPACING

6” MINIMUM CLEARANCE

TO ANY COMBUSTIBLE

SURFACE

CLEAN-OUT TEE

A 90 DEGREE ELBOW

MAY ALSO BE USED

4. Install PL-Vent wall thimble per PL-Vent manufacturer’s instructions.

6” MINIMUM CLEARANCE

5. Attach enough piping to penetrate and extend at least 6” beyond exterior walls. An 8-foot vertical pipe run is suggested where possible to reduce the possibility of smoke spillage in the event of a loss of negative pressure.

FIGURE 9

6. Attach cap and seal outside wall thimbles with nonhardening waterproof mastic.

7. Termination should not be located so that hot exhaust gases can ignite trees, shrubs, or grasses or be a hazard to children. Exhaust gases can reach temperatures of

500ºF and cause serious burns if touched.

Locate terminations: a) not less than 3 feet above any forced air inlet located within 10 feet; b) not less than 4 feet below or horizontally from, or one foot above, any door, window or gravity air inlet into any building; c) not less than two feet from an adjacent building and not less than 7 feet above grade when located adjacent to a public walkway. Mobile home installations must use a spark arrester.

8

C. VERTICALLY WITH NEW CHIMNEY SYSTEM

(Refer to Figure 10)

NOTE:

Follow PL-Vent chimney manufacturer’s instructions.

12” MINIMUM CLEARANCE

TO ROOF

VERTICAL ROOF VENT

ATTIC

INSULATION

SHIELD

OPTION:

To achieve a center vertical installation a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove.

3” MINUMUM

CLEARANCES TO

COMBUSTIBLES

OPTION:

Install PL-Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark point on ceiling. Install ceiling support and PL-Vent pipe per PL-Vent manufacturer’s instructions.

1. Always maintain 3” clearance from combustible materials.

When passing through additional fl oors or ceilings, always

install fi restop spacer.

L -VENT ADAPTER

TO

APPLIANCE

2. After lining up for hole in roof, cut either a round or square

hole in roof, always 3” larger all the way around pipe. Install

upper edge and sides of fl ashing under roo fi ng materials,

nail to the roof along upper edge. Do not nail lower edge.

Seal nail heads with non-hardening waterproof mastic.

3” MINUMUM

CLEARANCES TO

COMBUSTIBLES

CLEANOUT

TEE

FIGURE 10

EXISTING

CHIMNEY

SYSTEM

3. Apply non-hardening, waterproof mastic where the storm

collar will meet the vent and fl ashing. Slide storm collar down

until it sits on the fl ashing. Seal and install cap. Mobile home

installations must use a spark arrester.

45 DEGREE ELBOW

D. VERTICALLY INTO EXISTING CHIMNEY SYSTEM

Adapters are available to adapt from 3” PL-Vent to 6” or 8”

Class-A chimney. (Figure 11a)

As an alternative, 3” or 4” PL-Vent can be run inside existing chimney to termination. (Figure 11b)

This is the preferred method.

Follow guidelines for equivalent vent length.

PELLET VENT TO

CHIMNEY ADAPTER

(SPV-CA)

UNIVERSAL

CONNECTOR

FIGURE 11a

EXISTING

CHIMNEY

SYSTEM

PELLET

VENT

NOTE:

THIS METHOD

IS PREFERRED

FIGURE 11b

9

E. VERTICALLY INTO EXISTING MASONRY

FIREPLACE

NOTE:

Follow PL-Vent chimney manufacturer’s

instructions.

1. 1. Have the masonry chimney inspected by a qualifi ed chimney sweep or installer to determine its structural condition.

2. 2. You will need a pipe length equal to the chimney height from the hearth. If outside combustion air is to be used,You will need a pipe length equal to the chimney height plus 18 inches.

3. 3. Install a blanking plate and the chimney pipe, and if used the outside air pipe, as shown in Figure 12.

4. Attach the PL-Vent adapter, a section of pipe and clean out tee, making sure the clean out tee is centered in the chimney fl ue area. Use RTV, metallic tape, and a minImum of three self-taping screws at all joint connections to ensure a tight seal.

5. 5. Position the stove, adhering to the clearances in

Figures 1 & 2.

6. 6. Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe. Install and seal with non-hardening mastic to prevent water leakage. Install vent cap.

F. INSTALLATION THROUGH SIDE OF MASONRY

CHIMNEY

NOTE:

Follow PL-Vent chimney manufacturer’s

instructions.

1. Position the stove, adhering to the clearances in

Figures 1 & 2. Mark the center of the hole where the pipe is to pierce the masonry chimney.

2. It will be necessary to break out the masonry around the location of the pipe center mark. Use a 4-inch diameter hole for 3-inch pipe and 5-inch diameter hole for 4-inch pipe.

3. Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe.

4. Install the tee on the bottom of the vertical pipe system and lower it down the chimney until the center branch of the tee is level with the center of the hole in the masonry, as shown in Figure 13.

6”

FROM STOVE

TO

APPLIANCE

TO END OF HEARTH

TO

APPLIANCE

3”

NOTE:

FOLLOW METAL

CHIMNEY INSTALLATION

INSTRUCTIONS

NOTE:

FOLLOW METAL

CHIMNEY INSTALLATION

INSTRUCTIONS

3”

OPTIONAL OUTSIDE AIR

TRIM COLLAR

6”

HEARTH

6”

FIGURE 12

TOP PLATE

(SEAL TO CHIMNEY TOP

WITH NON-HARDENING

MASTIC)

EXTENSION TO CHIMNEY TOP

REQUIRED.

3 OR 4 INCH STAINLESS STEEL

SINGLE WALL PIPE OR FLEX PIPE.

BLANKING PLATE (SEAL WITH

NON-HARDENING MASTIC).

3 OR 4 INCH STAINLESS STEEL

FLEX PIPE.

OPTIONAL OUTSIDE AIR

CLEAN-OUT-TEE (TYPE L)

OR 90 DEGREE ELBOW

TOP PLATE

(SEAL TO CHIMNEY TOP

WITH NON-HARDENING

MASTIC)

EXTENSION TO CHIMNEY TOP

REQUIRED.

L-VENT OR OPTIONAL

3 OR 4 INCH STAINLESS STEEL

SINGLE WALL PIPE OR FLEX PIPE.

PIPE ADAPTER

5. Install and seal the top plate from step 3 with nonhardening mastic. Slip the storm collar over the pipe, and while holding the pipe at the proper elevation, affi x the collar with a minimum of three ¼” stainless steel sheet metal screws. Seal all joints and seams around the collar.

CLEAN-OUT TEE (TYPE L)

FIGURE 13

6. Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee. Push the pipe into the tee while twisting it to lock it into the tee.

7. If desired, once the horizontal pipe is in place, the space between the pipe and masonry may be fi lled with high-

temperature grout.

8. Install the trim collar. An adjustable pipe length and adapter may be needed to fi nish the connection to the stove.

10

Final approval is contingent on the authority having jurisdiction.

ELECTRICAL INSTALLATION

This stove is provided with a 6-foot grounded electrical cord extending from the rear of the stove. We recommend connecting to a good quality surge protector that is plugged into a standard three-prong, 120V, 60hz electrical outlet. Voltage variations can lead to serious performance problems. The US Stove electrical system is designed for 120V AC with no more than 5% variation. US Stove cannot accept responsibility for poor performance or damage due to inadequate voltage. If connected to an older, two-prong outlet, a separate ground wire should be run to a proper ground (refer this to a quali fi ed technician). Always route the electrical cord so that it will not come in contact with any hot part of the stove.

B

SECURE PEDESTAL TO FLOOR

WITH 2, 1/4” x 2” LONG

LAG BOLTS.

A

DRILL 2, 5/16” HOLES

IN PEDESTAL BASE.

FIGURE 21

SPECIAL MOBILE HOME REQUIREMENTS

WARNING: DO NOT INSTALL IN A SLEEPING ROOM.

NOTE: Installation should be in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280,

Part 24

For installation in a mobile home, an outside source of combustion air must be used (see “COMBUSTION AIR SUPPLY”).

The 5040 must be grounded to the steel chassis of the home with 8 Ga. copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding.

The 5040 must be securely fastened to the fl oor of the mobile home through the two holes in the rear of the stove using 2,

¼” lag bolts that are long enough to go through both a hearth pad, if used, and the fl oor of the home. (See fi gure 21)

Refer to “VENTING” for proper exhaust con fi gurations.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE

MAINTAINED.

11

PANEL CONTROLS (SEE FIGURE 22)

The blowers and automatic fuel supply are controlled from a panel on the left-hand side of the 5040. The control panel functions are as follows.

• When pushed the stove will automatically ignite. No other fi restarter is necessary.

The igniter will stay on for at least 10 and up to 15 minutes, depending on when

Proof of Fire is reached. The fi re should start in about 5 minutes.

• The green light located above the On/Off button (in the On/Off box) will fl ash during the ignition start-up period. (See fi gure 22)

• The Feed Rate Advance is inoperable during the ignition start period. When the red light continuously stays on the Feed Rate Advance can be adjusted to achieve the desired heat output.

NOTE: If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.

b. FUEL FEED SWITCH

• When the “Fuel Feed” button is pushed and held down the stove will feed pellets continuously into the burnpot.

• While the stove’s auger system is feeding pellets the amber light (in the “Fuel

Feed” box) will be on. (See fi gure 22)

CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BE-

CAUSE IT COULD SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUA-

TION.

c. HIGH FAN SWITCH

• The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch overrides this variable speed function. It will set the room air blower speed to high at any feed rate setting.

• When the “HIGH FAN” button is pushed the room air fan will switch to its highest setting.

• When this button is pushed again the room air fan will return to its original setting based on the Feed Rate Advance setting.

Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Feed Rate Advance bar graph.

This is usually a one-time adjustment based on the fuel you are using. The “RESET TRIM” button when adjusted will allow for 3 different feed rate settings for the #1 feed setting only. To adjust simply push the “RESET TRIM” button while the stove is operating at setting “1” and watch the bar graph.

• When the “1” and “3” lights are illuminated on the bar graph the low feed rate is at its “lowest” setting. (approx. 0.9 pounds per hour)

• When the “1” light is illuminated on the bar graph the low feed rate is at its “normal” setting.

• When the “1” & “4” lights are illuminated on the bar graph the low feed rate is at its “highest” setting.

NOTE: When the stove is set on “1” the “reset trim” values will be shown on the Feed Rate Advance bar graph. For example if the Reset Trim is set to its lowest setting every time the stove is set to low the “1” and “3” lights will be illuminated on the bar graph.

• This button when pushed will set the pellet feed rate, hence the heat output of your stove. The levels of heat output will incrementally change on the bar graph starting from level “1” to “4”.

NOTE: When dropping more than 2 heat level settings (i.e. 4 to 1) push the ‘High Fan’ button and allow the room air fan to run at that setting for at least 5 minutes to prevent the stove from tripping the high temp thermodisc. If the high temp thermodisc does trip see “SAFETY FEATURES”.

CAUTION: THE “4” SETTING IS DESIGNED FOR TEMPORARY USE ONLY. IF USED FOR EXTENDED PERIODS, IT

CAN SHORTEN THE LIFE EXPECTANCY OF THE UNITS COMPONENTS. AVOID USE AT THIS SETTING FOR MORE

THAN ONE HOUR AT A TIME.

12

VISIBLE SMOKE

The amount of visible smoke being produced can be an effective method of determining how ef fi ciently the combustion process is taking place at the given settings. Visible smoke consist of unburned fuel and moisture leaving your stove. Learn to adjust the air settings of your speci fi c unit to produce the smallest amount of visible smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess visible smoke and burn poorly.

PROPER FUEL

This heater is designed to burn only PFI Premium grade pellets. This appliance can also burn pellets rated as standard after

May 16, 2015

DO NOT BURN:

1. Garbage;

2. Lawn clippings or yard waste;

3. Materials containing rubber, including tires;

4. Materials containing plastic;

5. Waste petroleum products, paints or paint thinners, or asphalt products;

6. Materials containing asbestos;

7. Construction or demolition debris;

8. Railroad ties or pressure-treated wood;

9. Manure or animal remains;

10. Salt water driftwood or other previously salt water saturated materials;

11. Unseasoned wood; or

12. Paper products, cardboard, plywood, or particleboard.

The prohibition against burning these materials does not prohibit the use of fi re starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a fi re in an affected wood heater.

Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.

THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or

5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger fl ights, which prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void all warranties. The design incorporates automatic feed of the pellet fuel into the fi re at a carefully prescribed rate. Any additional fuel introduced by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke. Do not burn wet pellets. The stove’s performance depends heavily on the quality of your pellet fuel. Avoid pellet brands that display these characteristics: a. Excess Fines – “Fines” is a term describing crushed pellets or loose material that looks like sawdust or sand. Pellets can be screened before being placed in hopper to remove most fi nes.

b. Binders – Some pellets are produced with materials to hold them together, or “bind” them.

c. High ash content – Poor quality pellets will often create smoke and dirty glass. They will create a need for more frequent maintenance. You will have to empty the burnpot plus vacuum the entire system more often. Poor quality pellets could damage the auger. US Stove cannot accept responsibility for damage due to poor quality pellets. Your dealer can recommend a good quality pellet dealer in your area.

PRE-START-UP CHECK

Remove burnpot, making sure it is clean and none of the air holes are plugged. Clean the fi rebox, and then reinstall burnpot.

Clean door glass if necessary (a dry cloth or paper towel is usually suf fi cient). Never use abrasive cleaners on the glass or door. Check fuel in the hopper, and re fi ll if necessary.

NOTE: The 5040 Hopper can hold up to 45 lbs. of pellets.

BUILDING A FIRE

Never use a grate or other means of supporting the fuel. Use only the US Stove approved burnpot. CAUTION: DO NOT USE

CHEMICALS OR FLUIDS TO START FIRE. DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE,

NAPTHA OR ENGINE OIL.

During the start up period:

1. DO NOT open the viewing door.

2. DO NOT open the damper more than ¼”.

13

3. DO NOT add pellets to the burnpot by hand.

4. DO NOT use the Fuel Feed button (unless you are priming the auger after running out of pellets).

A dangerous condition could result.

NOTE: During the fi rst few fi res, your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal. Maintaining smaller fi res will minimize this. Avoid placing items on stovetop during this period because paint could be affected.

THE HOTROD AUTOMATIC FIRESTARTER

a. Fill hopper and clean burnpot.

b. Press “Power” button. Make sure light is on.

c. The damper should be completely closed or open no more than ¼” during start-up. This will vary depending on your installation and elevation. Once fi re is established adjust for desired fl ame increasing the amount the damper is open as the heat setting is increased. (See “DAMPER CONTROL”) d. Adjust feed rate to desired setting by pressing “Feed Rate Advance” button.

If fi re doesn’t start in 15 minutes, press “Power”, wait a few minutes and start procedure again.

DAMPER CONTROL

The damper control rod on the stove’s lower left side adjusts the combustion air. This control is necessary due to the varied burn characteristics of individual installations, different pellet brands and pellet feed rates. It allows you to improve the effi ciency of your stove. Providing correct combustion air will reduce the frequency of cleaning your glass door and prevent the rapid buildup of creosote inside your stove and chimney.

You should adjust the damper based on the fi re’s appearance. A low, reddish, dirty fi re can be improved by pulling the damper out slightly. A “blow torch” fi re can be improved by pushing the damper in a bit.

As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper should be more open. Through trial and error, you will fi nd the best setting. Consult your dealer if you need help.

NOTE: On “1”, damper should be either completely closed or out approximately ⅛ ” to ¼”. If damper is out too far, it can cause the fi re to go out.

OPENING DOOR

If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down. If the stove shuts down push the “Power” button to continue the operation of your stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually takes about 10 minutes from startup.

14

RE-STARTING A WARM STOVE

If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.

IF STOVE RUNS OUT OF PELLETS

The fi re goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes.

After the stove components stop running the “Power” and the BAR GRAPH lights stay on for 10 minutes.

After the 10 minutes the “3” light on the bar graph will fl ash and the “Power” light will go off.

To restart, re fi ll hopper, press “Power” button, and then press “Fuel Feed” button until pellets begin to fall into burnpot.

REFUELING

We recommend that you not let the hopper drop below ¼ full.

KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.

A tool has been provided to help with the following functions:

FIGURE 23 a. Stirring pellets in hopper

– unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur. Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help.

NOTE:

To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper.

b. Cleaning heat exchanger tubes

– see instructions in

“CLEANING”

.

c. Scrape ashes from burnpot.

SHUTDOWN PROCEDURE

Turning your US Stove stove off is a matter of pressing the “Power” control panel switch. The red light will go out. The blowers will continue to operate until internal fi rebox temperatures have fallen to a preset level.

SAFETY FEATURES

a. Your stove is equipped with a high temperature thermodisc. This safety switch has two functions.

1. To recognize an overheat situation in the stove and shut down the fuel feed or auger system.

2. In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing the stove from overheating.

NOTE:

On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove. On other units the thermodisc has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem. A service call may be required.

b. If the combustion blower fails, an air pressure switch will automatically shut down the auger.

NOTE:

Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air switch, shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove.

15

OPERATING SAFETY PRECAUTIONS

PLEASE READ THIS!

a. Hot while in operation.

Keep children, clothing, and furniture away. Contact may cause skin burns.

b. If you notice a smoldering fi re

(burnpot full but no visible fl ame)

AND a heavy smoke buildup in fi rebox, immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door, change the damper setting or tamper with any controls on the stove.

Wait until fi rebox clears, and blowers shut down, do as instructed in

“PRE-START-UP

CHECK”

and

“BUILDING A FIRE”,

then attempt to restart the fi re. If the problem persists contact your dealer.

c. WARNING: DO NOT ADD PELLETS TO THE BURNPOT BY HAND AT ANY TIME, A DANGEROUS CONDITION

COULD RESULT. d. WARNING: DURING THE START UP CYCLE; 1) DO NOT OPEN THE VIEWING DOOR; 2) DO NOT OPEN THE

DAMPER MORE THAN ¼”; 3) DO NOT USE THE FUEL FEED BUTTON

(UNLESS PRIMING THE AUGER AFTER

RUNNING OUT OF PELLETS).

A DANGEROUS CONDITION COULD RESULT.

e. Pellets should be stored in a dry place. The pellets should not be stored within 12” of the stove.

f. DO NOT STORE OR USE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, IN THE VICINITY OF YOUR US Stove

STOVE. NEVER USE A GAS OR PROPANE TORCH, GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE,

CHARCOAL LIGHTER FLUID OR SIMILAR FLUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER.

g. WARNING: DO NOT OVERFIRE THIS STOVE.

This may cause serious damage to your stove and void your warranty.

It also may create a fi re hazard in your home.

IF ANY EXTERNAL PART OF THE UNIT BEGINS TO GLOW, YOU ARE

OVERFIRING. Immediately press the “POWER” switch on the control panel.

h. KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES, SUCH AS FURNITURE, DRAPES, TOYS,

ETC. AT LEAST THREE FEET FROM THE OPERATING STOVE.

i. Maintain proper ventilation. It is important that adequate oxygen be supplied to the fi re for the combustion process.

Modern houses are often so well insulated that it may become necessary to open a window slightly or install an outside air vent to provide suf fi cient combustion air.

j. Since heating with a solid fuel is potentially hazardous, even with a well made and thoroughly tested stove, it would be wise to install strategically placed smoke detectors and have a fi re extinguisher in a convenient location, near an exit.

k. Do not open stove door when operating unless necessary. This will create a dirty, inef fi cient burn and could allow smoke spillage or sparks to escape.

l. Do not permit operation by young children or those unfamiliar with stove’s operation.

m. Do not service or clean this appliance without disconnecting the power cord.

n. Do not abuse the door glass by striking, slamming or similar trauma. Do not operate the stove with the glass removed, cracked or broken.

o. If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine on the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of the sensors could then make the stove start on its own. It is recommended that the stove be unplugged when not in use for extended amounts of time

(i.e. during the summer months). p. DO NOT USE ABRASIVE CLEANERS AND NEVER CLEAN WHEN HEATER IS HOT.

q. Attempts to achieve heat output rates that exceed heater design speci fi cations can result in permanent damage to the heater.

r. This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.

16

OPTIONAL THERMOSTAT

A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fi xed wall mount or

US Stove’s hand held model can be used. The control panel can be set up two ways to operate your stove in thermostat mode.

THERMOSTAT INSTALLATION

• A MILLIVOLT THERMOSTAT IS REQUIRED.

• Unplug stove from power outlet.

• Remove control board from stove.

• The two thermostat wires connect to the terminal block on the lower left side of the back of the control board. (See fi gure 24)

• Insert the wires in the terminal side and tighten the two screws.

MODES

TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE

MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE

STOVE RESTARTED.

MANUAL MODE

• USE THIS MODE EXCLUSIVELY IF YOU DO NOT CONNECT

AN OPTIONAL THERMOSTAT

• In this mode the stove will operate only from the control panel as detailed in the “OPERATION” section of this owner’s manual.

HIGH/LOW THERMOSTAT MODE

• USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT

• When engaged in this mode the stove will automatically switch between two settings. When warm enough, it will switch to the

#1 or low setting. The room air blower will also slow to its lowest speed.

FIGURE 24

• The Heat Level Advance setting on the bar graph will stay where it was initially set. When the house cools below the thermostat setting, the stove will switch to the feed rate of the heat level advance setting.

ON/OFF THERMOSTAT MODE

• USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT

• In this mode when the home is warm enough the stove will shut off. The fans will continue to run until the stove cools.

• When the home cools below the thermostat setting, the stove will automatically restart and run at the last feed rate setting.

NOTE: When in “high/low” or “on/off” thermostat mode –

• Do not operate the stove higher than the #3 setting.

• Set damper control rod approximately ¼” to ½” out. This will vary depending on elevation and weather conditions.

Observe stoves operation and adjust damper as necessary.

17

FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN

RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER

CLEAN WHEN HOT.

NOTE: Inspect burn pot periodically to see that holes have not become plugged, if so, clean thoroughly.

ASH REMOVAL

Disposal of Ashes - Ashes should be placed in a metal container with a tight fi tting id. The closed container of ashes should be placed on a noncombustible fl oor or on the ground, well away from all combustibles materials, pending fi nal disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retainer in the closed container until all cinders have been thoroughly cooled.

ASH DISPOSAL

Remove ashes periodically as they fi ll the fi rebox. To remove ashes: sure fi rebox is cool.

b. Clean heat exchanger tubes (see “CLEANING” and Figure 25).

c. Remove the burnpots inner section by grasping it and pulling straight up

(see Figure 26).

d. Empty ashes from the inner section and scrape with cleaning tool; make sure holes are not plugged.

e. Vacuum to remove ashes from the burn chamber interior and the burnpot shell.

WARNING: Make sure ashes are cool to the touch before using a vacuum. See “VACUUM USE”.

f. Dispose of ashes properly. (See “ASH REMOVAL” above) g. Replace inner section into burnpot; make sure it is level and pushed all the way back down and that the igniter hole is to the rear when it is reinstalled (see Figure 26).

h. Make sure the burnpot is level and pushed all the way in, if the collar on the burnpot attached to the fresh air tube is not pushed back to meet the fi rebox wall, the Hot Rod will not work properly.

SMOKE AND CO MONITORS

CLEANING

ROD

CLEANING

TOOL

FIGURE 25

FIGURE 26

Burning wood naturally produces smoke and carbon monoxide (CO) emissions. CO is a poisonous gas when exposed to elevated concentrations for extended periods of time. While the modern combustion systems in heaters drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or con fi ned areas can be dangerous. Make sure your stove gaskets and chimney joints are in good working order and sealing properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas having the potential to generate CO.

VACUUM USE

If a vacuum is used to clean your unit, we suggest using a vacuum designed for ashes. (We recommend LoveLess Ash Vac, 1-800-568-3949 Ext. #27)

Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special fi lter or bag available to eliminate this leakage.

CLEANING

a. Heat Exchange Tubes – Your US Stove stove is designed with a built-in heat exchange tube cleaner. This should be used every two or three days to remove accumulated ash on the tubes, which reduces heat transfer on the 5040. Insert the handle end (with hole) of the cleaning tool onto the cleaning rod (refer to fi gure 25). The cleaner rod is located in the grill above the stove door. Move the cleaner rod back and forth several times to clean the heat exchanger tubes. Be

18

sure to leave tube cleaner at the rear of the stove.

b. Interior Chambers – Four ash doors and two upper baf fl es in the fi rebox in the 5040 can be removed for periodic cleaning (Figure 27). These doors allow access to the chamber surrounding the fi rebox.

NOTE: When removing the upper baf fl es do not remove the screws; just loosen them enough to allow the baf fl es to be removed.

Periodically, you must vacuum ashes from this chamber. In some cases you will need to remove creosote, which can accumulate rapidly under certain conditions. A small wire brush can be used. It is important to remove this creosote because it is highly combustible. INSPECT BEHIND THESE CLEANING PLATES

AT LEAST ONCE PER TON OF PELLETS BURNED

UNTIL YOU ARE FAMILIAR WITH HOW ASHES AND

CREOSOTE ACCUMULATE WITH YOUR OPERAT-

ING PRACTICES. Use the small wire brush to also clean the inside of the chamber walls, above the access doors.

BLOWERS

DANGER: RISK OF ELECTRIC SHOCK. DISCON-

NECT POWER BEFORE SERVICING UNIT.

Cleaning –

Over a period of time, ashes or dust may collect on the blades of both the combustion blower and convection blower. Periodically the blowers should be vacuumed clean as these ashes can impede performance. Creosote can also accumulate in the combustion blower. This needs to be brushed clean. The convection blower is accessed by removing the stove’s left side panel. The combustion blower can be accessed by removing the stove’s right side panel. The convection blower is on the left (facing stove), and the combustion blower is on the right.

NOTE:

When cleaning, be careful not to dislodge balancing clip on convection blower or to bend fan blades.

Some stove owners lightly spray an anti-creosote chemical on the fi re to help reduce creosote formation within the stove.

GASKETS

This unit’s door uses a 5/8” diameter rope gasket.

Combustion

Blower

(A-E-027)

Auger Motor

(C-E-017)

Convection

Blower

(A-E-033)

FIGURE 28

Auger Shaft

(A-AUG-22)

Combustion

Blower

(A-E-027)

POF

Thermodisc

(C-E-090-22C)

Pellet

Hopper

High Temp

Thermodisc

(C-E-090-21)

Air Switch

(C-E-200)

Air Inlet

Tube

CAUTION: This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.

FIGURE 29

19

CHIMNEY CLEANING

a. Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney fl ue or a newly started fi re or from a slow-burning fi re. As a result, creosote residue accumulates on the fl ue lining. When ignited, this creosote makes an extremely hot fi re, which may damage the chimney or even destroy the house. Despite their high ef fi ciency, pellet stoves can accumulate creosote under certain conditions.

b. Soot and Fly Ash: Formation and Need for Removal - The products of combustion will contain small particles of fl y ash.

The fl y ash will collect in the exhaust venting system and restrict the fl ow of the fl ue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least once every year or ton of pellets burned to determine if cleaning is necessary.

c. Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or fl y ash build-up has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fi re. Inspect the system at the stove connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as well as from the bottom.

The creosote should be removed with a brush speci fi cally designed for the type of chimney in use. A quali fi ed chimney sweep can perform this service. It is also recommended that before each heating season the entire system be professionally inspected, cleaned and, if necessary, repaired.

To clean the chimney, detach the vent at the combustion blower transition where it is attached to the blower.

RECOMMENDED MAINTENANCE SCHEDULE

Establish a routine for the fuel, wood burner and fi ring technique. Check daily for creosote buildup until experience shows how often you need to clean to be safe. Be aware that the hotter the fi re the less creosote is deposited, and weekly cleaning may be necessary in mild weather even though monthly cleaning may be enough in the coldest months. Contact your local municipal or provincial fi re authority for information on how to handle a chimney fi re. Have a clearly understood plan to handle a chimney fi re. Use this as a guide under average-use conditions.

Burn Pot

Glass

Combustion Chamber

Ashes

Interior Chambers

Heat Exchange Tubes

Combustion Blower Blades

Convection Blower Impeller

Vent System

Gaskets

Hopper (end of season)

Daily

Stirred

Wiped

Weekly

Emptied

Cleaned

Brushed

Two passes

Annually or per Ton

Emptied

Vacuumed

Vacuumed / Brushed

Vacuumed / Brushed

Cleaned

Inspected

Emptied and vacuumed

Gasket around door and door glass should be inspected and repaired or replaced when necessary. (See “REPLACEMENT

PARTS”)

REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS (8.8” x 13.25” x 0.197” Ceramic Glass)

While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the doorframe. Dispose of all broken glass properly. Return the damaged door to your US Stove Dealer for repair or replacement.

Neither the appliance owner nor any other unauthorized person(s) should replace the door glass. An authorized US Stove dealer must perform all repairs involving door glass.

20

When your stove acts out of the ordinary, the fi rst reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems encountered are often the result of only fi ve factors: 1) poor fuel;

2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5. Refer to diagrams on page 20 to help locate indicated parts.

For the sake of troubleshooting and using this guide to assist you, you should look at your heat level setting to see which light is fl ashing.

** CAUTION – UNPLUG THE STOVE FROM ALL POWER PRIOR TO ATTEMPTING TO SERVICE THE UNIT! **

STOVE SHUTS OFF AND THE #2 LIGHT FLASHES

Possible Causes: Possible Remedies:

1. Air fl ow switch hose or stove attachment pipes

for hose are blocked.

2. The air inlet, burnpot, interior combustion air

chambers, combustion blower, or exhaust

pipe are blocked with ash or foreign material.

3. The fi rebox is not properly sealed.

Unhook air hose from the air switch and blow through it. If air fl ows freely, the hose and tubes are fi ne. If air will not fl ow through the hose, use a wire coat hanger to clear the blockage.

Follow all clearing procedures in the maintenance section of the owner’s manual.

Make sure the door is closed and that the gasket is in good shape. If the ash door has a latch, make sure the ash door is properly latched and the gasket is sealing good. If the stove has just a small hole for the ashes to fall through under the burnpot, make sure the slider plate is in place to seal off the fi rebox fl oor.

4. Vent pipe is incorrectly installed.

Check to make sure vent pipe installation meets criteria in owner’s manual.

5. The air fl ow switch wire connections are bad. Check the connectors that attach the gray wires to the air switch.

6. The gray wires are pulled loose at the Molex

connector on the wiring harness.

7. Combustion blower failure

Check to see if the gray wires are loose at the

Molex connector.

With the stove on, check to see if the combustion blower is running. If it is not, you will need to check for power going to the combustion blower. It should be a full current. If there is power, the blower is bad. If there is not, see #8.

8. Control board not sending power to combus-

tion blower.

9. Control board not sending power to air

switch.

10. Air switch has failed (very rare).

If there is no current going to the combustion blower, check all wire connections. If all wires are properly connected, you have a bad control board.

There should be a 5-volt current (approximately) going to the air switch after the stove has been on for 30 seconds.

To test air switch, you will need to disconnect the air hose from the body of the stove. With the other end still attached to the air switch, very gently suck on the loose end of the hose (you may want to remove the hose entirely off the stove and the air switch fi rst and make sure it is clear). If you hear a click, the air switch is working.

BE CAREFUL! TOO MUCH VACUUM CAN DAMAGE

THE AIR SWITCH.

21

22

STOVE SHUTS OFF AND THE #3 LIGHT FLASHES

Possible Causes:

1. The hopper is out of pellets.

2. The air damper is too far open for a low feed

setting.

3. The burnpot is not pushed completely to the

rear of the

5. The air inlet, the interior chambers, or exhaust

system has a partial blockage.

6. The hopper safety switch has failed or hopper

is open. fi rebox.

4. The burnpot holes are blocked.

Possible Remedies: (Unplug stove fi rst when possible)

Re fi ll the hopper

If burning on the low setting, you may need to close the damper all the way (push the knob in so it touches the side of the stove).

Make sure that the air intake collar on the burnpot is touching the rear wall of the fi rebox.

Remove the burnpot and thoroughly clean it.

Follow all cleaning procedures in the maintenance section of the owner’s manual.

When operating the unit, be sure the hopper lid is closed so that the hopper safety switch will activate. Check the wires leading from the hopper safety switch to the control panel and auger motor for secure connections. Use a continuity tester to test the hopper safety switch, replace if necessary.

7. The auger is jammed.

8. The auger motor has failed.

9. The Proof of Fire (POF) thermodisc has

malfunctioned.

Start emptying the hopper. Then remove the auger motor by removing the auger pin. Remove the auger shaft. Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing. Next, remove the two nuts that hold the top auger biscuit in. Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove. After you have removed the shaft, inspect it for bent fl ights, burrs, or broken welds. Remove any foreign material that might have caused the jam. Also, check the auger tube for signs of damage such as burrs, rough spots, or grooves cut into the metal that could have caused a jam.

Remove the auger motor from the auger shaft and try to run the unit. If the motor will turn, the shaft is jammed on something. If the motor will not turn, the motor is bad.

Temporarily bypass the POF thermodisc by disconnecting the two brown wires and connecting them with a short piece of wire. Then plug the stove back in. If the stove comes on and works, you need to replace the POF thermodisc. This is for testing only. DO NOT LEAVE THE THERMODISC BY-

PASSED. Your blowers will never shut off and if the fi re went out, the auger will continue to feed pellets until the hopper is empty if you leave the POF thermodisc bypassed.

10. The high limit thermodisc has tripped or is

defective

12. The control board is not sending power to the

POF thermodisc or other auger system

components.

Wait for the stove to cool for about 30-45 minutes. It should now function normally. If not, use the owner’s manual to locate the high limit thermodisc. To test if the thermodisc is bad, you can bypass it as described previously for the POF thermodisc.

11. The fuse on the control board has blown. Remove the control board. On the back, there is one fuse. If it appears to be bad, replace it with a 5 Amp 125 Volt fuse. Plug the stove back in and try to run the unit.

There should be a 5-volt (approximately) current going to the

POF thermodisc after the stove has been on for 10 minutes.

STOVE FEEDS PELLETS, BUT WILL NOT IGNITE

Possible Causes:

1. Air damper open too far for ignition.

2. Blockage in igniter tube or inlet for igniter tube.

3. The burnpot is not pushed completely to the rear of

the fi rebox.

4. Bad igniter element.

The control board is not sending power to the igniter.

Possible Remedies:

Push the air damper in closer to the side of the stove for startup. In some situations, it may be necessary to have the damper completely closed for ignition to take place. After there is a fl ame, the damper can then be adjusted for the desired feed setting.

Find the igniter housing on the backside of the fi rewall. The air intake hole is a small hole located on the bottom side of the housing. Make sure it is clear. Also, look from the front of the stove to make sure there is not any debris around the igniter element inside of the igniter housing.

Make sure that the air intake collar on the burnpot is touching the rear wall of the fi rebox.

Put power directly to the igniter element. Watch the tip of the igniter from the front of the stove. After about 2 minutes, the tip should glow. If it does not, the element is bad.

Check the voltage going to the igniter during startup. It should be a full current. If the voltage is lower than full current, check the wiring. If the wiring checks out good, the board is bad.

SMOKE SMELL COMING BACK INTO THE HOME

Possible Causes:

1. There is a leak in the vent pipe system.

2. The gasket on the combustion blower has gone

bad.

Possible Remedies:

Inspect all vent pipe connections. Make sure they are sealed with RTV silicone that has a temperature rating of

500 o

F or higher. Also, seal joints with UL-181-AP foil tape.

Also, make sure the square to round adapter piece on the combustion blower has been properly sealed with the same

RTV.

Inspect both gaskets on the combustion blower to make sure they are in good shape.

CONVECTION BLOWER SHUTS OFF AND COMES BACK ON

Possible Causes: Possible Remedies:

1. The convection blower is overheating and

tripping the internal temperature shutoff.

2. Circuit board malfunction.

Clean any dust off the windings and fan blades. If clearing the blower does not help, the blower may be bad.

Test the current going to the convection blower. If there is power being sent to the blower when it is shut off, the control board is fi ne. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board.

23

STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED

Possible Causes: Possible Remedies:

1. Fuse on control board blew.

2. High limit switch has tripped or is defective.

Remove the control board. On the back, there is one fuse. If it appears to be bad, replace it with a 5 Amp 125 Volt fuse.

Plug the stove back in and try to run the unit.

Wait for the stove to cool for about 30-45 minutes. It should now function normally. If not, use the owner’s manual to locate the high limit thermodisc. To test if the thermodisc is bad, you can bypass it as described previously for the POF thermodisc.

3. Bad auger motor.

4. Auger jam

4. Loose wire or connector

5. Bad control board

Remove the auger motor from the auger shaft and try to run the unit. If the motor will turn, the shaft is jammed on something. If the motor will not turn, the motor is bad.

Start by emptying the hopper. Then remove the auger motor by removing the auger pin. Remove the auger shaft inspection plate in the hopper so that you see the auger shaft.

Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing.

Next, remove the two nuts that hold the top auger biscuit in.

Then rotate the bottom end of the auger shaft up towards you until you can lift the shaft out of the stove. After you have removed the shaft, inspect it for bent fl ights, burrs, or broken welds. Remove any foreign material that might have caused the jam. Also, check the auger tube for signs of damage such as burrs, rough spots, or grooves cut into the metal that could have caused a jam.

Check all wires and connectors that connect to the auger motor, high limit switch, and the Molex connector.

If the fuse is good, the wires and connectors check out good, and the high limit switch did not trip, test fi r power going to the auger motor. If there is not a full current going to the auger motor when the fuel feed light is on, you have a bad control board.

24

GLASS “SOOTS” UP AT A VERY FAST RATE

FLAME IS LAZY, DARK AND HAS BLACK TIPS

AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS

Possible Cause:

1. Stove or vent pipe is dirty, which restricts air fl ow

through the burnpot.

2. Vent pipe installed improperly.

Possible Remedies:

Follow all cleaning procedure in the maintenance section of the owner’s manual.

3. Air damper is set too far in (closed) for a higher

setting.

4. Burnpot holes are blocked.

5. Air damper is broken.

Check to make sure the vent pipe has been installed according to the criteria in the owner’s manual.

Put the damper knob farther out away from the side of the stove and try not to burn the unit again.

Remove the burnpot and thoroughly clean it.

6. Blockage in air intake pipe.

Visually inspect the damper assembly. Make sure the damper plate is attached to the damper rod. When the damper rod is moved, the plate should move with it.

Visually inspect the air intake pipe that leads into the burnpot for foreign material.

7. Circuit board malfunction.

8. Combustion blower is not spinning fast enough.

9. Bad Pellets

(Applies to “GLASS ‘SOOTS’ UP AT A VERY

FAST RATE” only.

10. The trim setting on the low feed rate is too low.

(Applies to “GLASS ‘SOOTS’ UP AT A VERY

FAST RATE” only.

Time the fuel feed light at each setting (after the stove has completed the startup cycle). Make sure the times match the auger timing chart. If the auger motor runs constantly, the board is bad.

Test the RPM on the blower after the blades have been cleaned. The RPM should be approximately 3000RPM.

The brand of pellets or the batch of pellets that are being used may be of poor quality. If possible, try a different brand of pellets. You might also want to try a brand that is made from a different type of wood (softwood vs. hardwood).

Different woods have different characteristics when being burned.

Use the “Reset Trim” button to increase the low feed rate setting. If the “1” & “3” lights are on, the stove is currently on the lowest setting. If only the “1” light is on, the stove is in the default (medium) setting. If the “1” & “4” lights are on, the stove is in the high trim setting for the low feed rate. If the stove is being burned on one of the two lower settings, advance to the next trim setting and try burning the stove.

25

HIGH LIMIT SWITCH KEEPS TRIPPING

Possible Causes:

1. The convection blower is overheating and tripping the

internal temperature shutoff.

2. The stove is being left on the highest setting for exten-

ded periods of time.

3. Fuel other than wood pellets is being burned in the stove.

4. Power surge or brown out situation.

5. High limit switch is malfunctioning.

Possible Remedies:

Clean any dust off the windings and fan blades. If oiling the blower does not help, the blower may be bad

The highest level setting is designated for use over short periods of time. Burning the stove on the highest setting for longer that 1-2 hours could lead to potential overheating situations.

US Stove pellet stoves are designed and tested to use wood pellets. Check for signs of fuel other than wood pellets. No other type of fuel have been approved for US Stove pellet stoves. If there are signs of other types of fuel being used, stop using them immediately.

A power surge, spike, or voltage drop could cause the high limit switch to trip. Check to see if a surge protector is being used on the stove. If not, recommend one to the consumer.

If the other items checked out ok, replace the high limit switch.

DIGITAL CIRCUIT BOARD TIMING RATES

Heat Level Setting BIG E

1 & 3

1

1 & 4

2

3

4

5

Total Cycle Time

1.4 seconds

2 seconds

2.5 seconds

4 seconds

7 seconds

9 seconds

12 seconds

14.5 seconds

SMOKE SMELL OR SOOT BUILD-UP

Because it is a wood-burning device, your US Stove may emit a faint wood-burning odor. If this increases beyond normal or is you notice an unusual soot buildup on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed. Also, clean your stove following instructions in “MAINTENANCE.” If problem persists, contact your dealer.

26

WHITE

WHITE

PURPLE

BLACK

WHITE

ORANGE

ORANGE

BLUE

PINK

YELLOW

RED

GRAY

GRAY

POWER SUPPLY

120 VOLTS AC

27

Contact an Authorized US Stove Pellet Stove Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.

ITEM

AIR SWITCH

AIR SWITCH HOSE

AUGER MOTOR

US Stove MAINTENANCE TOOL

BURNPOT

CERAMIC BRICK PANEL SET -

OPTIONAL

CERAMIC LOG SET (imitation) -

OPTIONAL

CIRCUIT BOARD / CONTROL PANEL

COMBUSTION BLOWER

CONVECTION BLOWER

DAMPER KNOB

DOOR GASKET

DOOR GLASS

DOOR HANDLE

EXHAUST ADAPTER 4”

HOT ROD IGNITER

HOPPER MICRO SWITCH

REMOTE THERMOSTAT (ACUMEN)-RF-

OPTIONAL

THERMODISC, HIGH TEMP

THERMODISC, PROOF OF FIRE

WINDOW CLIPS, BOTTOM / AIRWASH

WINDOW CLIPS, SIDE

WINDOW GASKET (6’ - 1”)

PART#

C-E-201

C-M-340-T

C-E-017M

A-TOOL-96

A-S-BURNPOT

A-M-BRICK22

A-M-LOG

A-E-101

A-E-027J

A-E-033A

C-M-013

C-G-050

C-D-031

C-D-050

A-4-VA

C-E-IGN

C-E-901

AG-RCN

C-E-090-21

C-E-090-22C

C-S-398

C-S-110

C-G-033

IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL

MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE

APPLIANCE MANUFACTURER.

USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.

28

advertisement