Original instructions SIRe Advanced Modbus communication GB .... 2 SIRe Modbus This manual describes how to connect SIRe Advanced with Modbus/RTU via RS485, the technical specification of the protocol in SIRe, the parameters and their use. For more information about other functions in SIRe, please see the main manual. For more information about Modbus please contact your BMS supplier or www.modbus.org Connection Modbus/RTU via RS485, connects on a 3 pole contact on terminal [BUS] on the SIReA1N. What information is presented Please see list of parameters. What information is not presented Information regarding run times for each individual unit is stored on the B1-pcb and can only be viewed locally. Modbus Information Supported functions Function codes 01, 02, 03, 04, 05, 06, 08, 15, and 16 are supported. Diagnostics (08) supports sub-codes 0, 2, 10, 11, 12, 13, and 14. PDU length Maximum PDU length is 256 bytes. Supported network topology General 2-wire topology described in Modbus specifications is supported. Multiple slaves are supported. Software supports only RTU mode; ASCII mode serial transmission is not supported. Ground level Internal and external bus shares the same common ground, the RS-485 signals are not isolated. Start and stop bits One start bit, one stop bit. Parity Current software uses only 'None' parity mode. Broadcast Broadcast not supported because A1 fails to not to respond broadcast. Setting values outside valid range If written values are outside their allowed range, they will be set to the nearest value which is in the range. Bus termination Bus is not terminated but it has 4.7 kohm pull-up and pull-down resistors. Registers used Coils, discrete inputs, and input registers are supported, but there are no registers. So the responce is always "Illegal data address". Holding register 16 bit integer register R/W Terminal Modbus/RTU RS-485 (EIA/TIA-485) Function 23 D0 A/A’ Non-inverting Pull-down [-] 24 D1 B/B’ Inverting Pull-up [+] 25 Com C/C’ Signal ground SIReUA1 Menu structure - Gateway functions > Installer menu Mixing cabinet External control General settings > Installer menu > External control 0-10V fan control 0-10V heat control Gateway functions > Installer menu > External control > Gateway functions > Installer menu > External control > Gateway functions System on/off enable Room temp. enable Outdoor temp. enable Fan speed enable Heating step enable Door position enable =4x00051 =4x00049 > Installer menu > External control > Gateway functions > Installer menu > External control > Gateway functions Baud rate and Modbus ID is set locally, using the control panel, SIReUA1, see menu structure. System on/off enable Room temp. enable Outdoor temp. enable Heating step enable Door position enable Week program enable =4x00046 =4x00050 Explanation: Room temp. enable Outdoor temp. enable Water temp. enable Door position enable Week program enable Modbus ID =4x00047 =4x00052 Ambient Electrically heated Water heated AC FH All Air Curtains Fan Heaters All type > Installer menu > External control > Gateway functions > Installer menu > External control > Gateway functions > Installer menu > External control > Gateway functions > Installer menu > External control > Gateway functions Outdoor temp. enable Water temp. enable Fan speed enable Week program enable Modbus ID Baud rate =4x00086 Set using UA1 > Installer menu > External control > Gateway functions > Installer menu > External control > Gateway functions Water temp. enable Fan speed enable Heating step enable Week program enable Modbus ID Baud rate =4x00048 Set using UA1 Register Room temperature Outdoor temperature Fan speed Heating step Door position System on/off Week program Room temp. day SET Room temp. night SBT High speed limit Speed closed door Low Summer/Winter Season Door mode Fan mode FanMode Stepless fan control T max speed winter TmaxH T min speed winter TminH T min speed summer TminC T max speed summer TmaxC Over run mode Auto/fix High speed over run Hdelay Low speed over run Ldelay Outdoor temp. limit TLIMH Eco / Comfort TcomfortMode Open door setp. diff. DiffS Heating step diff. DiffH Room temp. sensor Calib Outdoor temp. sensor Calib Return temp. sensor Return temp. limit Heating step limit Modbus 4x00001 4x00002 4x00003 4x00004 4x00005 4x00006 4x00007 4x00008 4x00009 4x00010 4x00011 4x00012 4x00013 4x00014 4x00015 4x00016 4x00017 4x00018 4x00019 4x00020 4x00021 4x00022 4x00023 4x00024 4x00025 4x00026 4x00027 4x00028 4x00029 4x00030 4x00031 0 0 0 -10,0 -10,0 0 0 0 5 0 0 0 -30 -30 -30 -30 0 0 0 0 0 0 5 5 0 0 0 0 0 -1500 -1500 Min 3 90 1 10,0 10,0 10,0 10,0 1 35 500 180 1 30 30 30 30 1 3 2 1 100 100 35 35 2 1 1 100 100 1500 1500 Max Step °C K K 0,1°C 0,1°C °C s s °C °C °C °C % % °C °C % % 0.1°C 0.1°C Unit All All All All AC All All AC AC AC AC AC AC AC All FH AC All AC All All All All All AC All All All All Type Limit the heat, when using stepless heat, 0-100% Maximum temperature of return water when WTA is used (temp. > [set value] reduces the waterflow) 0 = Room, 1 = Return water. If WTA is used, set 4x00029=1 Offset of the outdoor temperature value Offset of the room temperature value The temperature difference between activation of electrical heating steps or increase of fan speed for water heated FH. Increase of temperature set value when the door opens. 0 = Eco, 1 = Comfort. See main manual for function description. Blocks the heat when value on outdoorsensor is above set value. Set overruntime for low speed when parameter 4x00020=1 Reads currently used overrun time when 4x00020=0 and not the manually set value. Rounds to nearest multiple of 10. Manually set overruntime for High speed when parameter 4x00020=1 0 = Auto, 1 = User See main manual for function description. At what outside temperature the AC should run at high speed during summer conditions At what outside temperature the AC should run at low speed during summer conditions At what outside temperature the AC should run at low speed during winter conditions At what outside temperature the AC should run at high speed during winter conditions 0 = Off, 1 = On Used for controlling a unit with frequency inverter, EC-motors or other 0-10VDC controlled fan. 0 = Auto, 1 = Thermostat, Manual fan, 2 = Thermostat, Auto fan, 3 = Manual 0 = Auto, 1 = Fix Open/Close, 2 = Fix open Set depending on use of door (Always open, open/closed or a mix.) 0 = Summer (no heat), 1 = Winter (Heat available) Parameter not active in Advanced. Speed limit at closed door Limits the fans maximum speed (For AC, at open door) Temperature setpoint when Night is active Temperature setpoint during Day time (deafault value) 0 = Off, 1 = Day, 2 = Night. To write: set parameter 4x00052=1 0 = Off, 1 = On. To write: set parameter 4x00051=1 0 = Closed door, 1 = Open door. To write: set parameter 4x00050=1 Read or write heat step. To write: set parameter 4x00049=1 Read or write fan speed. To write: set parameter 4x00048=1 Read or write outdoor temperature. To write: set parameter 4x00047=1 Read or write room temperature. To write: set parameter 4x00046=1 Notes Register Stepless heat control Control range limit Filter timer on/off Filter timer setting External filter guard Last filter change HCFL Mixing cabinet ctrl ON/OFF Min outlet temp. Day damper pos. DPD Night damper pos. DPN External on/off ON/OFF 0-10V fan control ON/OFF 0-10V heat control ON/OFF Set point correction Enable ext. room temp. Enable ext. outd. temp. Enable ext. fan speed Enable ext. heating step Enable ext. door contact Enable ext. on/off Enable ext. week prgm. Clock, year Clock, month Clock, day of month Clock, hours Clock, minutes Clock, seconds Max over run time Delay/ DelayF It over run stop T Time interval stages ET Modbus 4x00032 4x00033 4x00034 4x00035 4x00036 4x00037 4x00038 4x00039 4x00040 4x00041 4x00042 4x00043 4x00044 4x00045 4x00046 4x00047 4x00048 4x00049 4x00050 4x00051 4x00052 4x00053 4x00054 4x00055 4x00056 4x00057 4x00058 4x00059 4x00060 4x00061 1 10 10 0 0 0 1 1 2010 0 0 0 0 0 0 0 -10 0 0 0 0 0 5 0 0 0 0 5 0 Min 10 40 300 59 59 23 31 12 2099 1 1 1 1 1 1 1 10 1 1 1 100 100 35 1 1 9950 1 35 1 Max min °C s s m h °C % % °C h h °C Unit AC All All All All All All All All All All AC All All All All All All All All FH FH FH FH All All All All All All Type During the function Stages (see main manual) the roomtemp is measured every [set value] minute If internal temp. Drops below set value during overrun countdown, the fan stops. Fan overrun countdown after heat has been on. Rounds to nearest multiple of 10. Reading year copies system clock to internal buffer. All reads and writes are from/to internal buffer. Writing seconds copies time from internal buffer to system clock. 0 = Off, 1 = On Set =1 if BMS should write value to SIRe 0 = Off, 1 = On Set =1 if BMS should write value to SIRe 0 = Off, 1 = On Set =1 if BMS should write value to SIRe 0 = Off, 1 = On Set =1 if BMS should write value to SIRe 0 = Off, 1 = On Set =1 if BMS should write value to SIRe 0 = Off, 1 = On Set =1 if BMS should write value to SIRe 0 = Off, 1 = On Set =1 if BMS should write value to SIRe If central sensor is used and offset is required 0 = Off, 1 = On (ExternalHeatControlEnable) A1X T13-14 Activate if external heat signal is connected to terminals 13 and 14 0 = Off, 1 = On (ExternalFanControlEnable) A1X T11-12 Activate if external fan rpm signal is connected to terminals 11 and 12 0 = Off, 1 = On (ExternalOnOffEnable) A1X T15-16 Activate if external On/Off signal is connected to terminals 15 and 16 sets damper position during night time sets damper position during day time or if no week program is used Set minimum air outlet temperature. 0 = Off, 1 = On. Activate when fan heater is used together with mixing cabinet. Time since last filter change. Read only 0 = Off, 1 = On. Activate if external filter guard is connected to terminals 9 and 10. Set countdown time for the filter alarm. Rounds to nearest multiple of 50. 0 = Off, 1 = On. Activates the filter timer Limits a Users maximum set value 0 = Off, 1 = On. For water heated units 4x00032=1. For electrical units additional external components must be used for stepless heat. Notes Min. water flow 0-3 V, 0,1V step Door contact func. NC/NO It_react It_alarm RTG_react RTG_alarm Min. return temp. Device ID Read only: Motor alarm TK Over heating alarm ON/OFF Outlet temp. Limit Outlet temp. limit Eco Outlet temp. limit Diff Outlet temp. limit Alarm Installation year Installation month Installation day Reserved for future use, no access. 4x00063 4x00064 4x00065 4x00066 4x00067 4x00068 4x00069 4x00070 4x00071 4x00072 4x00073 4x00074 4x00075 4x00076 4x00077 4x00078 4x00079 4x00080 E2 two or more B1 have same ID 4x00102 Reserved for future use, no access. 4x00089 E1 Communication error Reserved for future use, no access. 4x00088 4x00101 Reserved for future use, no access. 4x00087 Reserved for future use, no access. Enable ext. return water temp. 4x00086 Reset alarm Baud rate 4x00085 4x00100 Modbus ID 4x00084 4x00090 Reserved for future use, no access. 4x00083 4x00082 Mixing Cab. Outdoor temp. limit 4x00081 Return water temperature. (WTA) 0 Functionality mode Comp/Adv 4x00062 0 0 0 0 -50 30 0 20 20 0 0 5 5 5 5 5 0 0 Min Modbus Register 1 1 1 1 50 100 100 100 100 1 1 30 20 20 15 15 1 30 1 Max °C 0,1°C °C °C °C °C °C °C °C 0,1V Unit All All All All All FH All All All All All All All All All All AC All Type Please see QG/main manual for information regarding alarm and errors. Communication error may sometimes not be presented via Modbus. Reads 1 if at least one alarm is active. Write 1 to reset all alarms. 1 = Off, 1 = On. Set =1 if BMS should write value to SIRe 0 = 2400, 1 = 4800, 2 = 9600, 3 = 19200, 4 = 38400, 5 = 57600 Read only. SIRe to receive water temp. from BMS. Write/Read to/from BMS. To write: set parameter 4x00086=1 Read only. For information only. Read only. For information only. Read only. For information only. [Set value] = overheat alarm [Set value] above outlet temp. Limit, Heat=0 [Set value] limits the air outlet temperature in Eco mode (32°C) Heat decreases [Set value] limits the air outlet temperature in Comfort mode, overides set 0 = Normal, 1 = Disabled. Activate/Deactivate internal over heat alarm 0 = Normal, 1 = Disabled. Activate/Deactivate motorprotection alarm 1=AC1, 2=AC2…, 129=FH1, 130=FH2… 254/255=Unknown or error. Unit program, Reads from B1. Depends on unit. Should not be changed. Frost protection: At stationary fan, [Set value] is the minimum return water temperature. Frost protection: Return water sensor (WTA) Set value opens valve , stops fan and closes damper Frost protection: Return water sensor (WTA) Set value opens valve Frost protection: Internal temp sensor Set value opens valve , stops fan and closes damper Frost protection: Internal temp sensor Set value opens valve 0 = NC, 1 = NO. (Only physical contact). Invert door contact function Set minimum waterflow when valve is closed. 0,1V=1% 0 = Advanced, 1 = Competent. Set functionlevel. If competent is set, the system ignore outdoor sensor value or errors Notes Register E3 B1 without program E4 Missing/faulty RTX sensor on B1 Always zero, writes ignored E6 Faulty RTG sensor on B1 E7 Missing RTG (when mandatory) E8 It sensor error Always zero, writes ignored E10 two B1 with different program Always zero, writes ignored E12 Missing/faulty RTX on A1X Always zero, writes ignored E14 Outdoor sensor error Always zero, writes ignored Always zero, writes ignored Always zero, writes ignored Always zero, writes ignored Always zero, writes ignored Always zero, writes ignored E21 Sensor error in UA1 Always zero, writes ignored E23 Incompatible B1 Always zero, writes ignored Always zero, writes ignored Always zero, writes ignored Always zero, writes ignored Always zero, writes ignored A1 Motor alarm A2 Overheat alarm A3 Freeze alarm A4 Filter alarm A5 External alarm Reserved for future use, no access. Reserved for future use, no access. Empty Modbus 4x00103 4x00104 4x00105 4x00106 4x00107 4x00108 4x00109 4x00110 4x00111 4x00112 4x00113 4x00114 4x00115 4x00116 4x00117 4x00118 4x00119 4x00120 4x00121 4x00122 4x00123 4x00124 4x00125 4x00126 4x00127 4x00128 4x00129 4x00130 4x00131 4x00132 4x00133 4x00134 4x00135 Empty 0 0 0 0 0 0 0 0 0 0 0 Min 1 1 1 1 1 1 1 1 1 1 1 Max Unit Type Empty Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Units with software from different generations. Require excahange of components, contact Frico E22 not available through Modbus. Please see QG/main manual for more information. E20 not available through Modbus. Please see QG/main manual for more information. Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Please see QG/main manual for information regarding alarm and errors. Notes Notes
advertisement
Related manuals
advertisement