MIRA AZORA

ELECTRIC SHOWER

Installation and User Guide

These instructions are to be left with the user

1

CONTENTS

Patents and Design Registration ...........................................................2

Introduction .............................................................................................3

Guarantee .................................................................................................3

Important Safety Information .................................................................4

Pack Contents Checklist ........................................................................6

Specifications ..........................................................................................7

1. Plumbing ..........................................................................................7

2. Electrical ...........................................................................................7

3. Standards and Approvals .................................................................7

Installation Requirements ......................................................................7

1. Plumbing ..........................................................................................7

2. Electrical ...........................................................................................9

Installation .............................................................................................10

Installation of Mira Azora ....................................................................10

Commissioning .....................................................................................14

User Instructions ...................................................................................16

Fault Diagnosis ......................................................................................20

Maintenance ...........................................................................................22

Dimensions ............................................................................................24

Spare Parts ............................................................................................25

Wiring Diagram ......................................................................................27

Customer Service ..................................................................................28

PATENTS AND DESIGN REGISTRATION

Design Registration: 000578463-001-002

Patents: GB: 2 341 667, 2 404 000, 2 428 286

Ireland: 82835, 85128, 85163

Patent Applications: GB: 2 427 460

Ireland: 2006/0462

If you experience any difficulty with the installation or operation of your new Electric

Shower, please refer to ‘Fault Diagnosis’, before contacting Kohler Mira Ltd.

Our telephone and fax numbers can be found in the back of this guide.

2

INTRODUCTION

Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference.

The Mira Azora is a thermostatic electric shower with separate controls for power selection and temperature/flow adjustment. A unique thermostatic valve stabilises temperature changes caused by water pressure fluctuations. These can result from taps being turned on or off, or a toilet being flushed. An individual light indicates

“START/STOP”.

The Mira Azora comes complete with a set of Mira Energise Shower Fittings.

Mira Azora 9.8 kW

A 9.8 kW 240 V AC (9.0 kW 230 V AC) heater with Mira Energise adjustable spray handset with four different spray actions (start, soothe, force and eco*). Supplied complete with flexible hose, clamp bracket assembly, slide bar, supports, hose retaining ring and soap dish. Available in the following finishes: frosted glass, blue glass, grape glass, white flock, stripes, flag, stones and dots.

* The eco setting reduces the water flow to give economical use of water, whilst still giving an adequate shower performance. This setting performs best with most gravity, pumped, and mains pressure unvented systems. On electric showers and some combination boiler systems the economy setting will have no effect, and will give the same spray action as the start setting.

Domestic

Recommended Usage

Light Commercial

Heavy Commercial

Healthcare

ü

ü

û

û

GUARANTEE

For domestic installations, Mira Showers guarantee the Mira Azora 9.8kW against any defect in materials or workmanship for a period of two years from the date of purchase (shower fittings for one year).

For non-domestic installations, Mira Showers guarantee the Mira Azora 9.8kW against any defect in materials or workmanship for a period of one year from the date of purchase.

For terms and conditions refer to section “Customer Services”.

3

IMPORTANT SAFETY INFORMATION

Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel.

Warnings!

Follow all warnings, cautions and instructions contained in this guide, and on or inside the appliance.

1 Products manufactured by us are safe and risk-free, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations.

2. Isolate the electrical and water supplies before commencing installation. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable.

3. Mains connections are exposed when the cover is removed.

4. Refer to the wiring diagram before making any electrical connections (refer to the wiring diagram at the back of this guide).

5. Make sure that any pipework that could become frozen is properly insulated.

6. Having completed the installation, make sure that the user is familiar with the operation of the appliance.

7. Make sure that this guide is left with the user.

8. DO NOT commission this appliance if water leaks from the unit or the heater tank pressure relief valve.

9. DO NOT fit any form of outlet control (e.g. Trigger handset) as the outlet acts as a vent for the tank body. Only Mira recommended outlet fittings should be used.

10. Make sure all electrical connections are tight, to prevent overheating.

11. The water supplies to this product must be isolated if the product is not to be used for a long period of time. If the product or pipework is at risk of freezing during this period they should also be drained of water.

12. Warning! DO NOT operate this appliance if it is frozen. Allow the appliance to thaw before using. The shower unit must not be fitted where it may be exposed to freezing conditions.

13. This product is not suitable for areas with high humidity (i.e steam rooms).

Please consult your installer.

14. THIS APPLIANCE MUST BE EARTHED. MAKE SURE SUPPLEMENTARY BONDING

COMPLIES WITH THE “REQUIREMENTS FOR ELECTRICAL INSTALLATIONS”.

The installation must be in accordance with the current edition of ’The Plugs and Sockets etc. (Safety) Regulations’ in force at the time of installation, this appliance is intended to be permanently connected to the fixed electrical wiring of the mains system.

15. If the wiring layout is changed or amended, the product functionally and safety may be affected.

4

16. If pipework and/or electical cables enter the shower from the rear through a hole in the wall . Provision must be made to prevent water ingress back into the wall structure.

17. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure there are no leaks

18. DO NOT Position the handset to spray water directly on to the appliance.

Eg.When cleaning shower control.

Caution!

1. Read all of these instructions and retain this guide for later use.

2. The electrical installation must comply to “BS 7671 - Requirements for Electrical

Installations”, commonly referred to as the IEE Wiring Regulations - Part 7, or any particular regulations and practices, specified by the local electricity supply company.

3. The plumbing installation must comply with the requirements of UK Water

Regulations/Bye-laws (Scotland), Building Regulations or any particular regulations and practices, specified by the local water company or water undertakers.

4. Make sure that you fully understand how to operate this shower and make sure that it is properly maintained in accordance with the instructions given in this manual.

5. Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to:

(a) The young.

The elderly.

The infirm.

(b)

(c)

(d)

(e)

(f)

The disabled.

Anyone who suffers from a medical condition that can result in temporary incapacity (e.g. epilepsy or blackouts).

Anyone inexperienced in the correct operation of the controls.

(g) Children should be supervised to ensure that they do not play with the appliance.

6. Sunburn or skin conditions can increase your sensitivity to hot water. Make sure that you set the shower to a cooler temperature.

7. If any of the following conditions occur, isolate the electricity and water supplies and refer to ”To contact us”, on the back page of this guide.

(a)

(b)

(c)

If the cover is not correctly fitted and water has entered the appliance case.

If the case is damaged.

If the appliance begins to make an odd noise, smell or smoke.

5

(d)

(e)

If the appliance shows signs of a distinct change in performance, indicating a need for maintenance.

DO NOT operate this appliance if water leaks from this appliance.

8. When this appliance has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy.

PACK CONTENTS CHECKLIST

Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included.

Mira Azora

1 x Mira Azora

1 x Olive

1 x Compression Nut

3 x Fixing Screws

3 x Wall Plugs

Documentation

1 x Installation Template

1 x Installer Checklist

1 x Guarantee Card

6

SPECIFICATIONS

1. Plumbing

Minimum maintained inlet pressure 70 kPa (0.7 bar).

100 kPa (1.0 bar) recommended for satisfactory operation.

Maximum static inlet pressure 1000 kPa (10 bar).

Minimum static pressure 20 kPa (0.2 bar) to keep the inlet valve closed.

2. Electrical

The Mira Azora 9.8 kW requires a 45 Amp fuse.

The terminal block will accept cable up to 16 mm 2 .

The Mira Azora is suitable for installation in Zone 1 and is rated IPX4.

3. Standards and Approvals

The Mira Azora complies with all relevant directives for CE marking.

INSTALLATION REQUIREMENTS

1. Plumbing

The appliance is designed to operate with a minimum maintained inlet pressure of 0.7 bar up to a maximum static inlet pressure of 10 bar.

When installed in very hard water areas (above 200 ppm temporary hardness) your installer may advise the installation of a water treatment device, to reduce the effects of limescale formation. Your local water company will be able to advise the hardness of water in your area.

It is recommended that a non-restrictive (free flowing) isolating valve is fitted in the cold water supply pipe to allow the complete maintenance of the appliance.

Do not use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressures.

The appliance is suitable for installation within the shower area. It is fitted with a pressure relief device and must be positioned over a water catchment area with the controls at a convenient height for all users.

The appliance must be fitted on to a finished flat and even wall surface (this wall surface should be tiled or waterproofed). DO NOT fit the appliance to the wall and tile up to the case. For safety requirements, an air gap must be left behind the appliance.

7

Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.

A Hose Retaining Ring is supplied to prevent the handset from dropping below the spill-over level of the bath or shower tray, which could lead to contamination from back-siphoning. The supplied Hose Retaining Ring should meet the majority of user requirements for shower installations with flexible outlet fittings.

However, there will be occasions when it will not provide a suitable solution.

In these instances an outlet double checkvalve, e.g. a Mira DCV-H, MUST be fitted. This will increase the required supply pressure typically by 10 kPa

(0.1 bar). Refer to section “Accessories”.

Supply pipework MUST be flushed to clear debris before connecting to the appliance.

To avoid damage to the case when soldered fittings are used, pre-solder the pipework and fittings before connecting them to the inlet connector assembly.

To ensure the case and other components are not put under strain during installation always provide mechanical support when making plumbing connections. Upon completion of the installation ensure connections and back case are not under any stress due to misaligned pipework or electrical cables.

Minimum

200 mm from ceiling

Convenient height for all the family

Fixed to finished wall surface

Isolating Valve

Avoid Sharp Kinks

Hose Retaining Ring

25 mm Min

Shower Tray

Bath

8

The appliance is fitted with a brass inlet compression assembly for connecting to a 15 mm supply pipe from the top, bottom or back. Double checkvalves, if fitted in the inlet supply to the appliance, can cause a pressure build-up, which could exceed the maximum static inlet pressure and damage the appliance.

2. Electrical

In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional demand. All Mira electric showers are high power units, it is essential to contact your electricity supplier to ensure that the supply is adequate for the product.

Voltage drop due to local heavy demand will reduce the shower’s performance.

The appliance MUST BE EARTHED by connecting the supply-cable earth conductor to the earth terminal.

SUPPLEMENTARY BONDING: Within the bathroom or shower room, all accessible conductive parts of electrical equipment and extraneous conductive parts (metal parts) that are likely to introduce earth potential, must be electrically bonded to earth using a minimum cable size of 4.0 mm² if the cable is not mechanically protected, (2.5 mm² if mechanically protected).

The minimum cable size (cross-sectional area) required should be in accordance with BS 7671.

As a guide only, and in accordance with BS 7671 we recommend close circuit protection: i.e. 9.8 kW = 45 Amp

A 30 mA Residual Current Device (RCD) MUST be included in the electrical circuit. This may be part of the consumer unit or a separate unit.

A separate, permanently connected supply must be taken from the consumer unit to the appliance through a double-pole switch, which has at least 3 mm of contact separation. The switch can be a ceiling mounted pullcord type within the shower room, or a wall mounted switch in an adjacent room.

DO NOT twist the individual cable cores of either the live or neutral conductors, as this will prevent them from entering the terminal block.

DO NOT exert strain on the terminal block. Ensure that the electrical connections are tightly screwed down.

DO NOT turn-on the electrical supply until the plumbing has been completed.

9

Consumer Unit

Double-pole

Isolating Switch

INSTALLATION

Installation of Mira Azora

Warning! Turn off the electrical and water supplies before proceeding with the installation of the Mira Azora. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable.

Note!

An installation template is supplied to help you install the Mira Azora.

Cover Retaining

Screw

Remove the three cover retaining screws and the cover.

Caution! Handle the glass cover assembly with care.

10

Cover

Determine the direction of the inlet water supply: top (falling), bottom

(rising), or back inlet .

Note! Make sure that the back inlet does not go directly back into the wall.

Use a soldered elbow.

Swivel the inlet connector assembly to suit. Remove the inlet blanking cap. Avoid trapping the green earth bonding wire.

Before fitting the Cover, make sure that the appropriate cutouts have been removed to suit the supply entering the product.

Thoroughly flush the mains-fed cold water supply pipe. The supply must

be clean and free from debris BEFORE connecting the appliance.

To flush the pipework, turn on the water supply and drain a minimum of 10 litres

(2 gallons) of water into a bucket or catchment area. Turn off the water supply.

An installation template is supplied to help you install the Mira Azora.

Put the installation template on the wall and mark through the positions of the fixing holes. Ensure the position of these holes do not come in line with any buried cables or pipework. Make sure that sufficient electrical supply cable is available for connection to the terminal block.

Drill and plug the top two fixing holes. Secure the appliance to the wall with the screws provided. Drill the bottom fixing hole with the product in place. Alternative fixings (not supplied) may be necessary for some wall structures. Avoid drilling into any supply cable/pipe.

Install the mains-fed cold water supply pipe. Do not overtighten

( S e e P l u m b i n g I n s t a l l a t i o n

Requirements).

11

Feed cable into Case. Fit Earth sleeve (not supplied) and then strip insulation.

Do not twist cable cores.

Firmly connect the conductors. Do not exert strain on the terminal block.

Important! Make sure that the inlet earth wire is routed as shown. Failure to do so may cause product malfunction.

L = BROWN

E = GREEN/YELLOW

N = BLUE

Cover Retaining

Screw

Refit the Cover, making sure it is correctly located. Do not overtighten screws.

Caution! Handle the glass cover assembly with care.

Do not use alternative screws to secure the Cover. This can cause internal damage to the appliance.

Do not seal around the back of appliance.

When fitting the Cover, position the controls to correspond with the internal drive features as shown.

12

Cover

Terminal

Block

Electrical

Supply Cable

Holes For Cover

Retaining Screws

Fixing Screw

Heater Tank

Inlet Connector

Assembly

Cold Water Supply

Pipe (Bottom Entry)

13

COMMISSIONING

Before carrying out the commissioning procedure install the Shower Fittings, refer to the Shower Fittings Installation and User Guide.

If you are unsure how an electric shower works, please read through the section

“User Instructions” before continuing.

1.

2.

3.

Electrical supply is turned off at the mains.

4.

Turn control to full cold.

5.

6.

Turn the water supply fully on.

Check for water leaks.

7.

Set control to ‘I’.

8.

Switch on electrical supply.

9.

0 - 5 Secs

Press the ‘Start/Stop’ button.

Water will be at full force and at a cool temperature.

Turn the control slowly.

Temperature remains cool and flow is reduced

14

10.

Turn control to full cold.

13.

Set control to ‘III’.

15.

11.

12.

+

_

0 - 10 Secs

The temperature will rise slightly.

Set control to ‘II’.

14.

+

_

5 - 10 Secs

The temperature will rise further.

16.

17.

Adjust temperature as required.

Flow rate will adjust automatically.

18.

Press STOP.

19.

0 - 5 Secs

Isolate power.

The shower will purge water from its tank for a few seconds.

Residual water may drain over a few minutes.

Note! A slight hissing sound may be heard from the appliance during operation.

High mains water pressure and high shower temperatures will affect the tone. This is quite normal in use.

15

USER INSTRUCTIONS

How Your Electric Shower Works

Heated water is produced by adjusting the flow of cold water passed through a heater tank.

CO

LD

+

_

The shower has three heater settings.

+

_

+

_

The warmer the shower, the lower the flow rate and vice versa.

16

Thermostatic (Temperature-Stable)

The shower's top priority is to keep the desired water temperature constant. Electric showers with thermostatic control are able to keep a stable temperature across the range from hot to cold, whilst also dealing with fluctuations in electrical and water supplies. As a result, there is a temperature limit the shower cannot go beyond. For safety, this temperature is factory set and cannot be adjusted to make the shower hotter or colder.

ORDINARY

ELECTRIC

SHOWER

THERMOSTATIC

ELECTRIC

SHOWER

17

Using your Shower

Read the section “Important Safety Information” first.

1.

2.

Switch on electrical supply.

3.

Press the ‘Start/Stop’ button.

4.

+

_

Set to desired position.

5.

Check water temperature before entering shower.

+

_

6.

Allow 10 - 15 seconds for any temperature adjustments to reach the handset.

7.

8.

Press STOP button.

Shower will continue to run for a few seconds before stopping.

Isolate power.

Residual water may drain over a few minutes.

Note! A t the end of every shower make sure that the shower head points into the catchment area. A small amount of water may be retained in the shower handset after the shower has been turned off. This may drain over a few minutes.

Switch off the appliance at electrical isolating switch when not in use. This is for safety and is recommended with all electrical appliances.

18

The Effect of Seasonal Changes

+

_

* **

For a cold shower select I.

For a summer warm shower select II.

For a winter warm shower select III.

During extremes of mains water supply temperature, adjust heater setting to obtain a better showering temperature.

The Effect of Other Water Devices

Example of how shower temperature stabilises due to pressure changes.

+

_

± 2°C

Water inlet pressure fluctuations due to other draw offs (e.g. flushing toilet). Shower temperature will be controlled to within ± 2°C of the set temperature provided that the supply conditions remain within the required operating parameters (refer to section: ‘Specifications’).

19

FAULT DIAGNOSIS

The trouble shooting information tabled below gives details on probable causes and remedies should difficulties be encountered whilst the shower is in operation.

Warning! There are no user serviceable components beneath the cover of the appliance. Only a competent tradesperson should remove the front cover!

Symptom Probable Cause Possible Remedy

Appliance Fails to operate

Start/

Stop

Light

OFF

Heater

Setting

I/II/III

Any Electrical supply isolated at double pole switch.

Switch on electrical supply via the pullcord or wall mounted switch.

OFF Any

Shower cycles from hot to cold

ON II/III

Fuse blown or MCB/RCD tripped, indicating possible electrical fault.

Handset blocked.

Renew the fuse or reset the

MCB/RCD. If fault persists, contact your installer.

Remove and clean.

Unable to select a cool enough shower.

ON

ON

ON

ON

II/III

II/III

II/III

III

Wa t e r p r e s s u r e b e l o w minimum required for appliance operation.

Make sure incoming mains w a t e r s t o p c o c k a n d / o r appliance isolating valve is fully turned on.

Temperature dial or Heater setting too high.

Turn the heater selector knob to setting II or turn the temperature control until a cooler temperature is achieved.

Thermostatic mechanism is faulty or damaged.

Due to the rise in mains water supply temperature, the Heater setting may be too high.

Replace.

Turn the heater selector knob to II and adjust the temperature control until a suitable temperature is achieved.

All the following remedies must be performed by a competent tradesperson.

H a n d s e t dripping

OFF Any Insufficient water supply pressure for shut off.

The minimum static pressure to ensure shut off and prevent dripping is 0.2 bar.

Note! If other appliances are operating, static pressure may drop below 0.2 bar. Contact local water company. Renew the Flow Valve.

OFF Any Inlet valve faulty.

Replace.

20

Symptom

L o w o r n o flow.

Start/

Stop

Light

ON

ON

ON

ON

Heater

Setting

I/II/III

Any

Probable Cause Possible Remedy

Water supply pipework or inlet filter restricted by a blockage or partial blockage.

Flush supply pipe. Clean inlet filter.

Any Insufficient water supply pressure/flow for operation.

Contact local water company.

Supply pressure must be a minimum of 0.7 bar. Note: If other appliances are operating, pressure may drop below 0.7 bar.

Any

Any

Other outlets (e.g. toilet, garden hose, washing machine, etc.) drawing water while the shower is being used.

Turn off other appliances whilst shower is in use.

Handset blocked.

Remove and clean.

Operation of temperature c o n t r o l h a s l i t t l e o r n o effect on water temperature.

ON

ON

ON

No change in temperature between I/II/III settings.

ON

ON

ON

OFF

ON

ON

Any

Any

Any

II/III

II/III

II/III

II/III

Any

Any

Service tunnel or cover not fitted correctly causing Start/

Stop button not to operate.

Inlet Valve faulty.

Heater Tank excessively scaled.

Handset or inlet filter blocked.

Replace. In hard water areas consider the use of a water softener.

Remove and clean.

Inlet valve faulty.

Heater tank failure.

Check case inserts are cut and fitted correctly. Check services

(electrical or plumbing) are not interfering with location of service tunnel or cover.

Replace.

Replace.

Replace.

Microswitch failure.

Insufficient mains water pressure.

Replace.

Contact local water company.

Possible failure of flow valve, microswitch or heater tank.

Check the continuity of the microswitch or heater tank and replace parts as necessary.

21

Symptom

Water will not turn off.

Start/

Stop

Light

ON

ON

ON

Heater

Setting

I/II/III

Any

Probable Cause

Inlet valve, solenoid, or start/ stop switch faulty.

Possible Remedy

Replace as necessary.

Any

II/III

Supply pressure below 0.2 bar.

Insufficient water supply.

Contact local water company.

Check mains water static pressure.

Contact local water company.

Appliance fails to produce hot water when set on II/III heater settings.

ON

ON

II/III

II/III

P o s s i b l e f a i l u r e o f t h e microswitch or thermal switch.

Heater Tank failure.

Check the continuity of the microswitch or heater tank and replace parts as necessary.

Replace.

MAINTENANCE

Any maintenance must be carried out by a qualified tradesperson, following the instructions provided. Before replacing any parts, make sure that the underlying cause of the malfunction has been resolved.

Warning! There are no user-serviceable components beneath the cover of the appliance. Only a competent tradesperson should remove the cover.

Cleaning

Many household and industrial cleaners contain abrasive and chemical substances that can damage the finish of your shower. Only clean the shower and fittings with a mild washing-up detergent or soap solution, and then wipe them dry with a soft cloth.

Handset - Cleaning

Clean with mild washing up detergent or soap solution. Wipe dry with a soft cloth.

Poor shower performance can be avoided by cleaning the spray plate. Use thumb or soft cloth to wipe rubber nozzles. The handset must be descaled regularly.

22

Inlet Filter - Cleaning/Renewing

Read the section “Important Safety Information” first

Make sure that the electrical supply is turned off at the mains and that the water supply is fully turned off.

Remove the three screws and the cover.

Caution! Handle the glass cover assembly with care.

Cover Retaining Screw

Cover

Hold a wrench across the flats of the metal connector. Unscrew the filter using another wrench as shown. Clean or renew the Filter as necessary. Refit in reverse order making sure the Filter is screwed fully home.

Do not overtighten! Make sure plumbing connections are sealed before restoring electricity supply.

Refit the Cover making sure it is correctly located. Do not overtighten the screws.

Filter

23

77 mm

DIMENSIONS

233 mm

100 mm

367 mm

24

405.58

406.27

416.38

416.41

416.48

416.51

872.01

872.28

1563.519

1563.533

1563.534

1563.537

1563.538

1563.539

1563.540

1563.551

1634.015

1634.026

1623.009

1634.118

1634.119

1634.120

1634.121

1634.122

1634.123

1634.124

SPARE PARTS

Inlet Connector Assembly

Inlet Filter (with ‘O’ seal fitted)

Clamp Bracket (Inlet)

Thermal Switch

Latching Switch

Solenoid Coil

Microswitch N/O - 2 pin

Microswitch C/O - 3 pin

Terminal Block Assembly

Thermostatic Valve/Heater Tank 9.8 kW 240 V AC

Outlet Connector Assembly

Temperature Control Belt Thermostatic

Temperature Cam & Pulley

Switching Assembly

Inlet Valve Assembly

Component Pack - chrome - components identified ‘B’

Start/Stop LED Assembly

Screw Pack - components identified ‘A’

Cover Assembly - Frosted Glass

Cover Assembly - Blue Glass

Cover Assembly - Grape Glass

Cover Assembly - White Flock Glass

Cover Assembly - Stripes

Cover Assembly - Flag

Cover Assembly - Stones

Cover Assembly - Dots

ACCESSORIES

Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants.

Double Outlet Check Valve (DCV-H)

Chrome - 1.0.110.55.1

DCV-H: An outlet double check valve, designed to prevent the backflow or backsiphonage of potentially contaminated water, through shower controls which are fitted with a flexible hose as part of the outlet shower fitting.

Showerhead Holder

White - 2.1605.149

Chrome - 2.1605.150

If you're looking for additional flexibility in your shower, the

Showerhead Holder is the perfect solution. Makes showering easier for children, provides a useful additional holder for your Showerhead which fixes to the wall at the desired height.

Shower Seat

White - 2.1536.128

White/Chrome - 2.1536.129

For use in or out of the showering area. Note! Must be installed onto a solid wall.

Shower seat folds up when not in use.

25

Mira Azora Spare Parts Diagram

A

B

A

A

B

416.41

B

1563.519

1563.539

872.01

B

1563.538

406.27

A

872.28

1563.540

A

416.48 416.51

1563.507

A

A

1563.537

405.58

B

416.38

A 1563.534

1634.015

A

A

1563.533

1634.009

1634.118

1634.119

1634.120

1634.121

1634.122

1634.123

1634.124

26

WIRING DIAGRAM

L

N

E

Thermal Cutout

Disc

BROWN

BROWN

Start/Stop

L.E.D.

RED

BROWN Pressure/Power

Selector Switch

Solenoid

Valve

BROWN

BROWN

BLACK

RED

BLACK

GREEN

GREEN

START/STOP

BLUE

BLUE

Tank Connection

Inlet Connector

Load

BROWN

BLACK

RED

Internal Wiring Diagram

27

CUSTOMER SERVICE

Guarantee

Your product has the benefit of our manufacturer’s guarantee which starts from the date of purchase.

To activate this guarantee, please return your completed registration card, visit our website or free phone 0800

0731248 within 30 days of purchase (UK only).

Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose.

If you have not previously activated the guarantee, you will be required to do so prior to the provision of assistance.

If you do not activate your guarantee our Engineer will be entitled to charge full payment for the visit (Call out fee plus parts).

This guarantee is in addition to your statutory rights and is subject to the following conditions:

● The product must be installed and maintained in

accordance with the instructions given in this user

guide.

● Servicing must only be undertaken by us or our

appointed representative. Note! if a service visit

is required the product must be fully installed and

connected to services.

● Repair under this guarantee does not extend the original

expiry date. The guarantee on any replacement parts

or product ends at the original expiry date.

● For shower fi ttings or consumable items we reserve

the right to supply replacement parts only.

The guarantee does not cover:

● Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, lack of maintenance, build up of limescale, frost damage, corrosion, system debris or blocked fi lters) or where no fault has been found with the product.

● Water or electrical supply, waste and isolation issues.

● Compensation for loss of use of the product or consequential loss of any kind.

● Damage or defects caused if the product is repaired or modifi ed by persons not authorised by us or our appointed representative.

● Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes.

What to do if something goes wrong

If your product does not function correctly when you fi rst use it, contact your installer to check that it is installed and commissioned in accordance with the instructions in this manual. Should this not resolve the issue, contact our

Customer Services Team who will offer you or your installer advice and if applicable arrange for a Service Technician to call. If the performance of your product declines, check in this manual to see if simple home maintenance is required.

If you require further assistance call our Customer Services

Team.

Extended Guarantees

A selection of protection plans are available that enable you to cover repair bills for the life of your policy

(excludes Eire). Ring 01922 471763 for more details.

Helpdesk Service

Our dedicated Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit. We will need you to have your model name or number, power rating (if applicable) and date of purchase. As part of our quality and training programme calls may be recorded or monitored.

Mira Showers Website (www.mirashowers.co.uk)

From our website you can register your guarantee, download additional user guides, diagnose faults, purchase our full range of accessories and popular spares, refer to our FAQ’s and request a service visit.

Spares and Accessories

We maintain extensive stocks of genuine spares and accessories and aim to provide support throughout the product’s expected life. Payment can be made by phone at time of order using most major Credit or Debit cards and we aim to despatch orders within two working days. Items purchased from us are guaranteed for 12 months from date of purchase. For safety reasons spares exposed to mains voltages should only be fi tted by competent persons.

Returns – items can be returned within one month of date of purchase, providing that they are in good condition and the packaging is unopened. Please obtain authorisation from our Customer Services Team before return. We reserve the right to apply a 15% restocking charge.

Service / Repairs

We have a nationwide team of Service Technicians who can carry out all service or repair work to your product within the guarantee period and beyond. You have the assurance of a fully trained Mira Technician, genuine Mira spare parts and a 12 month guarantee on any chargeable work done.

Payment should be made directly to the Service Technician who will accept most major Credit or Debit cards.

To Contact Us

UK

Telephone: 0844 571 5000 www.mirashowers.co.uk

E-mail: [email protected]

Fax: 01242 282595

By Post: Mira Customer Services Dept, Cromwell Road,

Cheltenham, Gloucestershire, GL52 5EP

Eire

Telephone: 01 459 1344

E-mail: [email protected]

Fax: Dublin 01 459 2329

By Post: Modern Plant Ltd (Dublin),

Otter House, Naas Road, Clondalkin, Dublin 22

Mira is a registered trade mark of

Kohler Mira Limited.

The company reserves the right to alter product specifi cations without notice.

1062243-W2-G (J95L) 28 © Kohler Mira Limited, November 2010

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement