advertisement
Raynor Garage Doors
1101 E. River Road
Dixon, Illinois 61021 www.raynor.com
COMMERCIAL DOOR OPENER
Model ATS 2113X-CX 1/2 HP
For Residential And Light Duty Commercial Use
Install on Sectional Doors Only
Owner’s Manual
■
Please read this manual and the enclosed safety materials carefully!
■
Fasten the manual near the garage door after installation.
■
The door WILL NOT CLOSE unless the Protector System
®
is connected and properly aligned.
■
Periodic checks of the opener are required to ensure safe operation.
■
The model number label is located on the front panel of your opener.
■
DO NOT exceed 8 complete cycles of door operation per hour.
H
G
H
N O R
M
A
L
L
O
W
H
G
H
N O R
M
A
L
N
DOW
FO
W
L
O
TABLE OF CONTENTS
Introduction 2-5
Safety symbol and signal word review . . . . . . . . . . . . . . . . . . . . .2
Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Tools needed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Carton inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Hardware inventory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Assembly 6-7
Attach the rail to the motor unit . . . . . . . . . . . . . . . . . . . . . . . . . .6
Attach the chain to the sprocket and install the rail support bracket. . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Tighten the chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Installation 7-19
Installation safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Determine the header bracket location . . . . . . . . . . . . . . . . . . . . .8
Install the header bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Attach the rail to the header bracket . . . . . . . . . . . . . . . . . . . . . .10
Position the opener. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Hang the opener . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Install the door control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Install the light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Attach the emergency release rope and handle. . . . . . . . . . . . . .13
Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Install the Protector System ® . . . . . . . . . . . . . . . . . . . . . . . . 15-17
Fasten the door bracket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Connect the door arm to the trolley . . . . . . . . . . . . . . . . . . . . . .19
Adjustment 20-22
Adjust the travel limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Adjust the force. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Test the safety reversal system. . . . . . . . . . . . . . . . . . . . . . . . . .22
Test the Protector System ® . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Operation 23-25
Operation safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Using your garage door opener . . . . . . . . . . . . . . . . . . . . . . . . .23
Using the wall-mounted door control . . . . . . . . . . . . . . . . . . . . .24
To open the door manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Care of your garage door opener . . . . . . . . . . . . . . . . . . . . . . . .24
Having a problem? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Programming 26-28
3-Button remote controls (Optional) . . . . . . . . . . . . . . . . . . . . . .26
To add or change a Keyless Entry PIN (Optional) . . . . . . . . . . . .27
Multi-Function door control (Optional) . . . . . . . . . . . . . . . . . . . .28
Repair Parts 29-32
Rail assembly parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Installation parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Motor unit assembly parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Accessories 31
Repair Parts and Service 32
Warranty 32
INTRODUCTION
Safety Symbol and Signal Word Review
This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual.
Mechanical
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious
injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully.
Electrical
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.
2
Preparing your garage door
Before you begin:
• Disable locks.
• Remove any ropes connected to garage door.
• Complete the following test to make sure your garage door is balanced and is not sticking or binding:
1. Lift the door about halfway as shown. Release the door. If balanced, it should stay in place, supported entirely by its springs.
2. Raise and lower the door to see if there is any binding or sticking.
If your door binds, sticks, or is out of balance, call a trained door systems technician.
To prevent possible SERIOUS INJURY OR DEATH:
• ALWAYS call a trained door systems technician if garage door binds, sticks, or is out of balance. An unbalanced garage door may not reverse when required.
• NEVER try to loosen, move or adjust garage door, door springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension.
• Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement.
SERIOUS INJURY could result from the use of this product on one piece garage doors.
To prevent damage to garage door and opener:
• ALWAYS disable locks BEFORE installing and operating the opener.
• ONLY operate garage door opener at 120V, 60 Hz to avoid malfunction and damage.
Sectional Door
Tools needed
During assembly, installation and adjustment of the opener, instructions will call for hand tools as illustrated below.
Stepladder
Pencil
Carpenter’s
Level (Optional)
1 2
Tape Measure
Wire Cutters
Drill 3/16", 5/16" and
5/32" Drill Bits
1/2" and 7/16" Sockets and Wrench
Screwdriver
Pliers
3
Hack Saw
Claw Hammer
Adjustable End Wrench
Planning
Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener.
Without a properly working safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
• The gap between the bottom of the garage door and the floor MUST NOT exceed 1/4" (6 mm). Otherwise, the safety reversal system may not work properly.
• The floor or the garage door MUST be repaired to eliminate the gap.
SECTIONAL DOOR INSTALLATION
Horizontal and vertical reinforcement is needed for lightweight garage doors
(fiberglass, steel, aluminum, door with glass panels, etc.).
See page 18 for details.
Header Wall
Slack in chain tension is normal when garage door is closed.
FINISHED CEILING
Support bracket & fastening hardware is required.
See page 11.
Vertical Centerline of Garage Door
Extension Spring
OR
Torsion Spring
Access Door
Wallmounted
Door
Control
Safety Reversing Sensor
Gap between floor and bottom of door must not exceed 1/4"
Safety
Reversing
Sensor
Header
Bracket
Chain Pulley
Bracket
Chain
Trolley
CLOSED POSITION
Rail
Header
Wall
Garage
Door
Garage
Door
Spring
Door Bracket
Straight
Door
Arm
Curved
Door
Arm
Emergency
Release
Rope & Handle
4
Carton Inventory
Your garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below. Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam.
Hardware for installation is also listed below.
CEILING MOUNT ONLY
UP
Header Bracket with
Clevis Pin and Fastener
Mounting Hardware
(Rail Support Bracket)
Rail Support
Bracket
Lighted Door
Control Button
2 -Conductor Bell Wire
White & White/Red
Curved Door Arm
Styrofoam
Door Bracket
Door Bracket Plate
"C" Wrap (2)
Chain
Safety Reversing Sensor
Mounting Bracket
With Slot (2)
Safety Reversing Sensor
Mounting Bracket
With Square Holes (2)
Rail
Motor Unit
Straight
Door Arm
Trolley
Chain
Pulley Bracket
HARDWARE INVENTORY
Assembly Hardware
Washered Bolt, 5/16"-18x1/2" (2)
(Mounted in Opener)
Hex Screw 1/4"-20x5/8" (2)
Lock Washer 1/4"-20x5/8" (2)
Screw #8-32x3/8" (1)
Washered Bolt
5/16"-18x1/2" (2)
Safety Labels and Literature
The Protector System ®
(2) Safety Reversing Sensors
(1 Sending Eye and 1 Receiving Eye) with 2-Conductor White & White/Black
Bell Wire attached
Installation Hardware
Hex Screw 5/16"-18x7/8" (4)
Nut 5/16"-18 (4)
Lock Washer 5/16" (4)
Rail Grease
Lag Screw 5/16"-9x1-5/8" (2)
Lag Screw 5/16”-18x1-7/8” (2) -
Screw 6ABx1-1/2" (2)
Handle
Ring Fastener (3)
Self-Tapping Screw 1/4"-14x5/8" (2)
Insulated Staples (10)
Drywall Anchors (2)
Clevis Pin 5/16"x2-3/4" (1)
Clevis Pin 5/16"x1" (1)
Clevis Pin 5/16"x1-1/4" (1)
Rope
5
Hardware for Safety
Reversing Sensor
Lag Screw 1/4"x1-1/2" (4)
Carriage Bolt 1/4"-20x1/2" (4)
Lock Nut 1/4"-20 (4)
Wing Nut (2)
Hex Screw 1/4-20x1-1/2" (2)
Screw #10-32x3/8" (4)
Lock Nut #10x32 (4)
Insulated Staples (20)
N O R
M
FO
UP
RC E
W N O R M
DO WN E
FO
RC
W
ASSEMBLY STEP 1
Attach the Rail to the Motor Unit
To avoid installation difficulties, do not run the garage door opener until instructed to do so.
•
•
•
Place the opener on packing material to protect the cover.
Remove the (2) 5/16"-18x1/2" washered bolts mounted in the top of the motor unit.
Position rail at a 45˚ angle to opener so one hole in rail and motor unit line up.
Thread one of the washered bolts part way in.
•
Use only these bolts! Use of any other bolts will cause serious damage to door opener.
• Align rail over sprocket. Cut tape from rail.
To avoid SERIOUS damage to opener, ONLY use bolts/ fasteners mounted in top of motor unit.
Washered Bolt
5/16"-18x1/2"
USE ONLY THIS
TYPE AND SIZE
BOLT
Chain
Spreader
Sprocket
Rail
Chain
Opener
ASSEMBLY STEP 2
Attach the Chain to the Sprocket and Install the Rail
Support Bracket
•
•
•
•
•
Guide the chain over chain spreader and opener sprocket. If necessary, loosen the outer nut on the trolley to obtain more chain slack. Insert the second washered bolt. Use only the bolts previously removed from opener.
Tighten both bolts securely through the rail into the opener as shown.
Position the rail support bracket on the opener.
Attach the bracket to the rail with 1/4"-20x5/8" hex bolts and lock washers. DO NOT overtighten.
Attach the bracket to the opener by inserting a 5/16"-18x1/2" washered bolt through a hole in each side flange and a matching hole in the bracket. Complete the connection by inserting the #8-32x3/8" screw through the back flange and the hole in rail support.
Proceed to Assembly Step 3.
To avoid possible SERIOUS INJURY to fingers from moving garage door opener:
• ALWAYS keep hand clear of sprocket while operating opener.
• Securely attach rail support bracket BEFORE operating.
Washered Bolt
5/16"-18x1/2"
Hex bolts with Lock Washers
1/4"-20x5/8"
Rail Support
Bracket
Screw
#8-32x3/8"
Washered Bolt
5/16"-18x1/2"
Opener
Back Flange
Opener
Side Flange
6
HARDWARE SHOWN ACTUAL SIZE
Hex Bolt
1/4"-20x5/8"
Washered Bolt
5/16"-18x1/2"
Lock Washer Screw
#8-32x3/8"
ASSEMBLY STEP 3
Tighten the Chain
•
•
Spin the inner nut and lock washer down the threaded shaft, away from the trolley.
To tighten the chain, turn outer nut in the direction shown. As you turn the nut, keep the chain from twisting.
• When the chain is approximately 1/2" (1.27 cm) above the base of the rail at its midpoint, re-tighten the inner nut to secure the adjustment.
Sprocket noise can result if chain is either too loose or too tight.
When installation is complete, you may notice some chain droop with the door closed. This is normal. If the chain returns to the position shown when the door is open, do not re-adjust the chain.
NOTE: During future maintenance, ALWAYS pull the emergency release handle to disconnect trolley before adjusting chain.
You have now finished assembling your garage door opener. installation section.
To Tighten Outer Nut
Outer Nut
Lock
Washer
Inner Nut
To Tighten Inner Nut
Trolley
Chain
Base of Rail
1/2" (1.27 cm)
WARNING
INSTALLATION
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND
INSTRUCTIONS.
2. Install garage door opener only on properly balanced and lubricated garage door. An improperly balanced door may not reverse when required and could result in SEVERE
INJURY or DEATH.
3. ALL repairs to cables, spring assemblies and other hardware
MUST be made by a trained door systems technician
BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.
5. Install garage door opener 7 feet (2.13 m) or more above floor.
6. Mount emergency release handle 6 feet (1.83 m) above floor.
7. NEVER connect garage door opener to power source until instructed to do so.
8. NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of 5 feet
(1.5 m).
• away from ALL moving parts of the door.
10. Install the entrapment warning placard next to the control station in a prominent location.
11. Place manual release/safety reverse test label in plain view on inside of garage door.
12. Upon completion of installation, test safety reversal system.
Door MUST reverse on contact with a 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor.
7
INSTALLATION STEP 1
Determine the Header Bracket Location
To prevent possible SERIOUS INJURY or DEATH:
• Header bracket must be RIGIDLY fastened to structural support on header wall or ceiling, otherwise garage door might not reverse when required. DO NOT install header bracket over drywall.
• Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry.
• NEVER try to loosen, move or adjust garage door, springs, cables, pulleys, brackets, or their hardware, ALL of which are under EXTREME tension.
• ALWAYS call a trained door systems technician if garage door binds, sticks, or is out of balance. An unbalanced garage door might not reverse when required.
Header Wall
1. Close the door and mark the inside vertical centerline of the garage door.
2. Extend the line onto the header wall above the door.
You can fasten the header bracket within 4 feet (1.22 m) of the left or right of the door center only if a torsion spring or center bearing plate is in the way; or you can attach it to the ceiling (see page 9) when clearance is minimal. (It may be mounted on the wall upside down if necessary, to gain approximately 1/2" (1.27 cm).)
If you need to install the header bracket on a 2x4 (on wall or ceiling), use lag screws (not provided) to securely fasten the
2x4 to structural supports as shown here and on page 9.
3. Open your door to the highest point of travel as shown. Draw an inter secting horizontal line on the header wall 2" (5 cm) above the high point. This height will provide travel clearance for the top edge of the door.
Proceed to Step 2, page 9.
Unfinished
Ceiling
Vertical Centerline of Garage Door
2x4
2x4
OPTIONAL
CEILING
MOUNT
FOR
HEADER
BRACKET
Structural
Supports
Level
(optional)
Ceiling
Header Wall
2" (5 cm) Track
Highest Point of Travel
Door
SECTIONAL DOOR WITH CURVED TRACK
8
INSTALLATION STEP 2
Install the Header Bracket
You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. DO NOT install the header bracket over drywall. If installing into masonry, use concrete anchors (not provided).
WALL HEADER BRACKET INSTALLATION
• Center the bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown (with the arrow pointing toward the ceiling).
• Mark the vertical set of bracket holes (do not use the holes designated for ceiling mount). Drill 3/16" pilot holes and fasten the bracket securely to a structural support with the hardware provided.
HARDWARE SHOWN ACTUAL SIZE
Lag Screw
5/16"x9x1-5/8"
Wall Mounting Holes
CEILING MOUNT ONLY
UP
The nail hole is for positioning only. You must use lag screws to mount the header bracket.
Optional
Wall Mounting Holes
2x4
Header Wall
Structural
Support
Header
Bracket
CEILING MOUN
UP
LY
T ON
Vertical
Centerline of
Garage Door
Lag Screws
5/16"-9x1-5/8"
Door Spring
Horizontal
Line
Highest Point of
Garage Door Travel
Garage Door
Vertical
Centerline of
Garage Door
CEILING HEADER BRACKET INSTALLATION
• Extend the vertical centerline onto the ceiling as shown.
•
•
Center the bracket on the vertical mark, no more than 6"
(15 cm) from the wall. Make sure the arrow is pointing toward the wall. The bracket can be mounted flush against the ceiling when clearance is minimal.
Mark the side holes. Drill 3/16" pilot holes and fasten bracket securely to a structural support with the hardware provided.
The nail hole is for positioning only. You must use lag screws to mount the header bracket.
Ceiling Mounting Holes
CEILING MOUNT ONLY
UP
Door
Spring
6" (15 cm)
Maximum
– Finished Ceiling –
Header
Bracket
Vertical
Centerline of
Garage Door
UP
Lag Screws
5/16"-9x1-5/8"
– Header Wall –
Garage Door
Vertical
Centerline of
Garage Door
9
INSTALLATION STEP 3
Attach the Rail to the Header Bracket
•
•
•
•
Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help. Have someone hold the opener securely on a temporary support to allow the rail to clear the spring.
Position the chain pulley bracket against the header bracket.
Align the bracket holes and join with a clevis pin as shown.
Insert a ring fastener to secure.
Header Wall
Header
Bracket
Chain
Pulley
Bracket
Garage
Door
Rail
Ring Fastener
Header Bracket
Clevis Pin
5/16"x2-3/4"
Chain
Pulley
Bracket
Rail
Temporary
Support
HARDWARE SHOWN ACTUAL SIZE
Clevis Pin
5/16"x2-3/4"
10
Ring Fastener
INSTALLATION STEP 4
Position the Opener
SECTIONAL DOOR ONLY
A 2x4 laid flat is convenient for setting an ideal door-to-rail distance.
•
•
Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough.
Open the door all the way and place a 2x4 laid flat on the top section beneath the rail.
To prevent damage to garage door, rest garage door opener rail on 2x4 placed on top section of door.
• If the top section or panel hits the trolley when you raise the door, pull down on the trolley release arm to disconnect inner and outer sections. Slide the outer trolley toward the motor unit. The trolley can remain disconnected until
Installation Step 12 is completed.
Rail
Door
2x4 is used to determine the correct mounting height from the ceiling
ENGAGED
Trolley
Release Arm
RELEASED
INSTALLATION STEP 5
Hang the Opener
Two representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2), attach a sturdy metal bracket to structural supports before installing the opener. This bracket and fastening hardware are not provided.
1. Measure the distance from each side of the motor unit to the structural support.
2. Cut both pieces of the hanging bracket to required lengths.
3. Drill 3/16" pilot holes in the structural supports.
4. Attach one end of each bracket to a support with
5/16"-18x1-7/8" lag screws.
5. Fasten the opener to the hanging brackets with 5/16"-18x7/8" hex bolts, lock washers and nuts.
6. Check to make sure the rail is centered over the door (or in line with the header bracket if the bracket is not centered above the door).
7. Remove the 2x4. Operate the door manually. If the door hits the rail, raise the header bracket.
8. Grease the top and underside of the rail surface where the trolley slides with rail grease.
To avoid possible SERIOUS INJURY from a falling garage door opener, fasten it SECURELY to structural supports of the garage.
Concrete anchors MUST be used if installing ANY brackets into masonry.
Structural
Supports
Figure 1
Measure
Distance
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Hidden Support
Lag Screws
5/16"-18x1-7/8"
Lag Screws
5/16"-18x1-7/8"
FINISHED CEILING
(Not Provided)
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
HARDWARE SHOWN ACTUAL SIZE
Bracket
(Not Provided)
Figure 2
Lag Screw 5/16"-18x1-7/8"
Hex Bolt
5/16"-18x7/8" Nut 5/16"-18 Lock Washer 5/16"
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
11
INSTALLATION STEP 6
Install the Door Control
Locate the door control within sight of the door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from all moving parts of the door and door hardware.
1. Strip 7/16" (11 mm) of insulation from one end of the bell wire.
Connect it to the two screw terminals on the back of the door control by color: white wire to 2 and white/red wire to 1.
2. Fasten the Lighted Door Control Button securely with
6ABx1-1/2" screws. If installing into drywall, drill 5/32" holes and use the anchors provided.
3. Run the bell wire up the wall and across the ceiling to the opener. Use insulated staples to secure the wire in several places. Be careful not to pierce the wire with a staple, creating a short or open circuit.
4. Receiver terminal screws and the antenna are located on the back panel of the motor unit. Position the antenna wire as shown.
5. Connect the bell wire by color to the opener terminal screws: white to 2 and white/red to 1.
6. Use tacks or staples to permanently attach the entrapment warning label to the wall near the door control, and the manual release/safety reverse test in a prominent location on the inside of the garage door.
NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel to the full open position, but will not return to the close position until the sensor beam is connected and properly aligned. See Safety Reversing Sensor instructions beginning on page 15.
To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is not connected BEFORE installing door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
• Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/2"
Lighted Door Control Button Drywall Anchors
Insulated
Staples
Outside Keylock Accessory Connections
To opener terminal screws: White to 2 and white/red to 1.
2-Conductor
Bell Wire
TO PREVENT THE MOTOR PROTECTOR FROM
TRIPPING, DO NOT EXCEED 8 DOOR
OPERATIONS PER HOUR.
FASTEN LABEL ADJACENT TO DOOR
POUR ÉVITER QUE LE DISPOSITIF DE
PROTECTION DU MOTEUR NE SE
DÉCLENCHE, NE PAS FAIRE FONCTIONNER
LA PORTE PLUS DE 8 FOIS PAR HEURE.
FIXER L'ÉTIQUETTE PRÈS DE LA PORTE.
132A2112A
Lighted
Door Control
Terminal Screws
WARNING
Lighted
Door Control
Button
2-Conductor
Bell Wire
Moving Door Can Cause
Serious Injury or Death
Keep Clear! Door May Move at any Time
Without Prior Warning
Do Not Let Children Operate the Door or Play in the Door Area
Keep Door in Sight at all Times When Door is Moving
12
Opener
Terminal
Screws
1 2 3
9
7
5
KG
3
1 9
7
5
KG
3
1
Back Panel of Opener
Antenna
INSTALLATION STEP 7
Install the Light
•
•
Install a 75 watt maximum light bulb in the socket. The light will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the light will turn OFF.
If the bulb burns out prematurely due to vibration, replace with a “Garage Door Opener” bulb.
NOTE: Use only standard light bulbs. The use of short neck or specialty light bulbs may overheat the endpanel or light socket.
To prevent possible OVERHEATING of the endpanel or light socket,
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent.
75 Watt Max.
Light Bulb
Opener
INSTALLATION STEP 8
Attach the Emergency Release Rope and Handle
•
•
Thread one end of the rope through the hole in the top of the red handle so “NOTICE” reads right side up as shown. Secure with an overhand knot at least 1" (2.54 cm) from the end of the rope to prevent slipping.
Thread the other end of the rope through the hole in the release arm of the outer trolley.
• Adjust rope length so the handle is 6 feet (1.83 m) above the floor. Secure with an overhand knot.
NOTE: If it is necessary to cut the rope, heat seal the cut end with a match or lighter to prevent unraveling.
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
• If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
Trolley
Rope
NOTICE
Overhand
Knot
Trolley
Release Arm
Emergency
Release Handle
13
INSTALLATION STEP 9
Electrical Requirements
To avoid installation difficulties, do not run the opener at this time.
To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet. If the plug doesn't fit into the outlet you have, contact a qualified electrician to install the proper outlet.
To prevent possible SERIOUS INJURY or DEATH from electrocution or fire:
• Be sure power is not connected to the opener, and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection.
• Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter, or change plug in ANY way to make it fit outlet. Be sure the opener is grounded.
PERMANENT WIRING
CONNECTION
RIGHT WRONG
If permanent wiring is required by your local code, refer to the following procedure.
To make a permanent connection through the 7/8" hole in the top of the motor unit:
• Remove the motor unit cover screws and set the cover aside.
•
•
Remove the attached 3-prong cord.
Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.
• Reinstall the cover.
To avoid installation difficulties, do not run the opener at this time.
Green
Ground Screw
Ground Tab
Ground Wire
White Wire
Black
Wire
Black Wire
14
INSTALLATION STEP 10
Install The Protector System
®
The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction.
IMPORTANT INFORMATION ABOUT
THE SAFETY REVERSING SENSOR
When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam. The sending eye transmits an invisible light beam to the receiving eye. If an obstruction breaks the light beam while the door is closing, the door will stop and reverse to full open position, and the opener lights will flash 10 times.
The units must be installed inside the garage so that the sending and receiving eyes face each other across the door, no more than
6" (15 cm) above the floor. Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens.
Be sure power is not connected to the garage door opener
BEFORE installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from a closing garage door:
• Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled.
• Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.
If it is necessary to mount the units on the wall, the brackets must be securely fastened to a solid surface such as the wall framing.
If installing in masonry construction, add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other hardware) may interrupt the beam while the door is closing.
Safety Reversing Sensor
6" (15 cm) max. above floor
Facing the door from inside the garage
Invisible Light Beam
Protection Area
15
Safety Reversing Sensor
6" (15 cm) max. above floor
INSTALLING THE BRACKETS
Figure 1, 2 and 3 show recommended assembly of bracket(s) and
“C” wrap based on the wall installation of the sensors on each side of the garage door as shown on page 15, or on the garage door
tracks themselves.
Figure 4 and 5 are variations which may fit your installation requirements better. Make sure the wraps and brackets are aligned so the sensors will face each other across the garage door.
Garage Wall or Door Track Installation
1. Fasten the “C” wraps to the mounting brackets having square holes, using th hardware shown in Figure 1.
Garage Wall Installation
2. Connect each assembly to a slotted bracket, using the hardware shown on Figure 2. Note alignment of brackets for left and right sides of door.
3. Finger tighten the lock nuts.
4. Use bracket mounting holes as a template to locate and drill
(2) 3/16" diameter pilot holes on both sides of the garage door,
4"-6" (10-15 cm) above the floor but not exceeding 6" (15 cm)
(see warning on page 15).
5. Attach bracket assembly with 1/4"x1-1/2" lag screws as shown in Figure 2.
6. Adjust right and left bracket assemblies to the same distance out from mounting surface. Make sure all door hardware obstructions are cleared. Tighten the nuts securely.
Garage Door Track Installation
Discard slotted bracket. Drill 3/8" holes in each track and fasten securely with hardware as shown in Figure 3.
Figure 1 Garage WALL or DOOR Track Installation
Mounting Bracket
With Square Holes
“C” Wrap
#10-32x3/8"
Screws
#10-32
Lock Nuts
Figure 2 Garage WALL Installation
1/4x1-1/2"
Lag Screws
Inside
Garage
Wall
1/4-20x1/2" Carriage Bolts
(with square shoulder)
1/4"-20
Lock Nuts
Figure 3 Garage DOOR Track Installation
1/4"-20 Lock Nuts
Garage
Door Track
Inside
Garage
Wall
Mounting Bracket with Square Holes
Drill 3/8"
Holes
1/4-20x1/2"
Carriage Bolts
Mounting Bracket with Slot
Mounting Bracket with Square Holes
“C” Wrap
“C” Shaped
Wrap
Figure 4 Alternate Wall Mount
Inside
Garage
Wall Mounting Bracket with Slot
Mounting Bracket with Square Holes
“C” Wrap
Sensor with wire
Indicator Light
Garage
Floor
Figure 5 Figure 5 Alternate Floor Mount
Inside
Garage
Wall
“C” Wrap
Sensor with wire
Indicator Light
Mounting Bracket with Square Holes
Mounting Bracket with Slot
Attach with concrete anchors
(not provided)
Garage
Floor
HARDWARE SHOWN ACTUAL SIZE
Screw
#10-32x3/8"
Lock Nut
#10x32
Lag Screw 1/4x1-1/2"
16
Staples
Carriage Bolts
1/4"-20x1/2"
Lock Nut
1/4"-20
MOUNTING AND WIRING THE SAFETY SENSORS
• Center each sensor unit in a “C” wrap with lenses pointing toward each other across the door (see Figure 6).
•
•
Secure sensors with the hardware shown. Finger tighten the wing nut on the receiving eye to allow for final adjustment.
Securely tighten the sending eye wing nut.
Run the wires from both sensors to the opener (see Figure 7).
Use insulated staples to secure the wire to wall and ceiling.
• Strip 1/4" (6 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener terminal screws: white to 2 and white/black to 3.
ALIGNING THE SAFETY SENSORS
•
The sending eye indicator light will glow regardless of alignment or obstruction. If the indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place.
•
Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct.
Loosen the receiving eye wing nut and adjust sensor until it receives the sender’s beam. When the green indicator light glows steadily, tighten the wing nut.
Figure 6
Indicator
Light
"C" Wrap
Hex Bolt
1/4-20 x 1-1/2"
Wing
Nut
Sensor with Wire
TROUBLESHOOTING THE SAFETY SENSORS
1. If the sending eye indicator light does not glow steadily after installation, check for:
• Electric power to the opener.
•
•
•
A short in the white or white/black wires. These can occur at staples, or at opener connections.
Incorrect wiring between sensors and opener.
A broken wire.
2. If the sending eye indicator light glows steadily but the
receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
3. If the receiving eye indicator light is dim, realign either sensor.
NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will blink 10 times. (If bulbs are not installed, 10 clicks can be heard.) See page 15.
Connect Wire to
Opener Terminals
Figure 7
Bell Wire
Finished
Ceiling
Bell Wire
Wall Control
Connections
(dotted line)
1 2
Sensor
Connections
3
OPENER TERMINAL SCREWS
Safety Reversing
Sensor
Invisible Light Beam
Protection Area
Safety Reversing
Sensor
17
INSTALLATION STEP 11
Fasten the Door Bracket
A horizontal brace should be long enough to be secured to 2 vertical supports. A vertical brace should cover the height of the top panel.
The illustration shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron are used to create a "U"-shaped support. The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit.
Fiberglass, aluminum or lightweight steel garage doors WILL
REQUIRE reinforcement BEFORE installation of door bracket.
Contact your door manufacturer for reinforcement kit.
If your installation doesn't require vertical reinforce ment but does need top and bottom fastening holes for the door bracket, fasten as shown in Figure 2.
HARDWARE SHOWN ACTUAL SIZE
•
•
•
Center the door bracket on the previously marked vertical guideline used for the header bracket installation.
Position the bracket on the face of the door within the following limits:
A) The top edge of the bracket 2"-4" (5-10 cm) below the top edge of the door.
B) The top edge of the bracket directly below any structural support across the top of the door.
Mark and drill 5/16" left and right fastening holes. Secure the bracket as shown in Figure 1 if there is vertical reinforcement.
Self-Tapping Screw
1/4"-14x5/8"
Header
Bracket
Door Bracket
Location
Vertical
Centerline of Garage
Door
Horizontal and vertical reinforcement is needed for lightweight garage doors
(fiberglass, aluminum, steel doors with glass panel, etc.). (Not Provided)
Vertical
Reinforcement
Vertical
Centerline of
Garage Door
Door
Bracket
Self-Tapping Screw
1/4"-14x5/8"
Figure 1
Inside Edge of Door or
Reinforcement Board
Door
Bracket
Door
Bracket
Plate
Self-Tapping Screw
1/4"-14x5/8"
Figure 2
18
INSTALLATION STEP 12
Connect Door Arm to Trolley
SECTIONAL DOORS ONLY
•
•
Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley. Slide the outer trolley back (away from the door) about
2" (5 cm) as shown in Figures 1, 2 and 3.
Figure 1:
– Fasten straight door arm section to outer trolley with the
5/16"x1" clevis pin. Secure the connection with a ring fastener.
– Fasten curved section to the door bracket in the same way, using the 5/16"x1-1/4" clevis pin.
•
•
Figure 2:
– Bring arm sections together. Find two pairs of holes that line up and join sections. Select holes as far apart as possible to increase door arm rigidity.
Figure 3, Hole alignment alternative:
– If holes in curved arm are above holes in straight arm, disconnect straight arm. Cut about 6" (15 cm) from the solid end. Reconnect to trolley with cut end down as shown.
– Bring arm sections together.
•
– Find two pairs of holes that line up and join with bolts, lock washers and nuts.
Proceed to Adjustment Step 1, page 20. Trolley will re-engage automatically when opener is operated.
Figure 1
Ring
Fastener
Inner Trolley
Outer Trolley
Clevis Pin
5/16"x1"
Door
Bracket
Clevis Pin
5/16"x1-1/4"
Curved
Door Arm
Straight
Door Arm
Lock
Washers
5/16"
Nuts
5/16"-18
HARDWARE SHOWN ACTUAL SIZE Bolts
5/16"-18x7/8"
Emergency
Release
Handle
Door Bracket
Figure 2
5/16 po-18 x 7/8 po de 5/16 po
5/16 po-18
5/16 po x 1 po (Chariot)
5/16 po x 1-1/4 po
(Support de la porte)
Figure 3
Nuts
5/16"-18
Lock
Washers
5/16"
Cut This End
Bolts
5/16"-18x7/8"
19
ADJUSTMENT STEP 1
Adjust the UP and DOWN Travel Limits
Limit adjustment settings regulate the points at which the door will stop when moving up or down.
To operate the opener, press the Door Control push bar. Run the opener through a complete travel cycle.
•
•
Does the door open and close completely?
Does the door stay closed and not reverse unintentionally when fully closed?
If your door passes both of these tests, no limit adjustments are necessary unless the reversing test fails (Adjustment Step 3, page 22).
Adjustment procedures are outlined below. Read the procedures carefully before proceeding to Adjustment Step 2. Use a screwdriver to make limit adjustments. Run the opener through a
complete travel cycle after each adjustment.
NOTE: Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off. Simply wait 15 minutes and try again.
NOTE: If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel
(including binding or unbalanced doors), it will reverse.
Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system
MUST be tested. Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid flat) on floor.
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
HOW AND WHEN TO ADJUST THE LIMITS
•
•
If the door does not open completely but opens at least 5 feet
(1.5 m):
Increase up travel. Turn the UP limit adjustment screw clockwise. One turn equals 2" (5 cm) of travel.
NOTE: To prevent the trolley from hitting the cover protection bolt, keep a minimum distance of 2-4" (5-10 cm) between the trolley and the bolt.
If door does not open at least 5 feet (1.5 m):
•
Adjust the UP (open) force as explained in Adjustment Step 2.
If the door does not close completely:
Increase down travel. Turn the down limit adjustment screw counterclockwise. One turn equals 2" (5 cm) of travel.
If door still won't close completely and the trolley bumps into the pulley bracket (page 4), try lengthening the door arm
(page 19) and decreasing the down limit.
• If the opener reverses in fully closed position:
Decrease down travel. Turn the down limit adjustment screw clockwise. One turn equals 2" (5 cm) of travel.
2-4"
Cover
Protection
Bolt
Left Side
Panel
Adjustment Label
Limit
Adjustment
Screws
• If the door reverses when closing and there is no visible interference to travel cycle:
If the opener lights are flashing, the Safety Reversing Sensors are either not installed, misaligned, or obstructed. See
Troubleshooting, page 17.
Test the door for binding: Pull the emergency release handle.
Manually open and close the door. If the door is binding or unbalanced, call for a trained door systems technician. If the door is balanced and not binding, adjust the DOWN (close) force. See Adjustment Step 2.
20
ADJUSTMENT STEP 2
Adjust the Force
Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door.
If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction. Weather conditions can affect the door movement, so occasional adjustment may be needed.
The maximum force adjustment range is about 3/4 of a
complete turn. Do not force controls beyond that point. Turn force adjustment controls with a screwdriver.
NOTE: If anything interferes with the door’s upward travel, it will stop. If anything interferes with the door’s downward travel
(including binding or unbalanced doors), it will reverse.
Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
• Too much force on garage door will interfere with proper operation of safety reversal system.
• NEVER increase force beyond minimum amount required to close garage door.
• NEVER use force adjustments to compensate for a binding or sticking garage door.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system
MUST be tested. Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid flat) on floor.
HOW AND WHEN TO ADJUST THE FORCES
1. Test the DOWN (close) force
•
•
Grasp the door bottom when the door is about halfway through
DOWN (close) travel. The door should reverse. Reversal halfway through down travel does not guarantee reversal on a
1-1/2" (3.8 cm) obstruction. See Adjustment Step 3, page 22.
If the door is hard to hold or doesn’t reverse, DECREASE the
DOWN (close) force by turning the control counterclockwise.
Make small adjustments until the door reverses normally. After each adjustment, run the opener through a complete cycle.
If the door reverses during the down (close) cycle and the
opener lights aren’t flashing, INCREASE DOWN (close) force by turning the control clockwise. Make small adjustments until the door completes a close cycle. After each adjustment, run the opener through a complete travel cycle. Do not increase the force beyond the minimum amount required to close the door.
1
2. Test the UP (open) force
• Grasp the door bottom when the door is about halfway through
UP (open) travel. The door should stop. If the door is hard to
hold or doesn’t stop, DECREASE UP (open) force by turning the control counterclockwise. Make small adjustments until the door stops easily and opens fully. After each adjustment, run the opener through a complete travel cycle.
Back Panel of Opener
INCREASE
1
UP (open) force by turning the control clockwise. Make small
9 9 adjustments until door opens completely. Readjust the UP limit if necessary. After each adjustment, run the opener through a complete travel cycle.
7
5
KG
3 7
5
KG
Force Adjustment
Controls
2
9
7
5
KG
3
1
3
1
3
9
7
5
KG
3
1
Adjustment Label
21
ADJUSTMENT STEP 3
Test the Safety Reversal System
TEST
• With the door fully open, place a 1-1/2" (3.8 cm) board (or a
2x4 laid flat) on the floor, centered under the garage door.
• Operate the door in the down direction. The door must reverse on striking the obstruction.
ADJUST
• If the door stops on the obstruction, it is not traveling far enough in the down direction. Increase the DOWN limit by turning the DOWN limit adjustment screw counterclockwise
1/4 turn.
NOTE: On a sectional door, make sure limit adjustments do not force the door arm beyond a straight up and down position.
See the illustration on page 19.
•
•
Repeat the test.
When the door reverses on the 1-1/2" (3.8 cm) board, remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment.
IMPORTANT SAFETY CHECK:
•
•
Repeat Adjustment Steps 1, 2 and 3 after:
•
•
Each adjustment of door arm length, limits, or force controls.
Any repair to or adjustment of the garage door (including springs and hardware).
Any repair to or buckling of the garage floor.
Any repair to or adjustment of the opener.
Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the other control may also need adjustment.
• After ANY adjustments are made, the safety reversal system
MUST be tested. Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid flat) on the floor.
1-1/2" (3.8 cm) board
(or a 2x4 laid flat)
ADJUSTMENT STEP 4
Test the Protector System
®
•
•
Press the remote control push button to open the door.
Place the opener carton in the path of the door.
• Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm), and the opener lights will flash.
The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).
If the opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6" [15 cm] above the floor), call for a trained door systems technician.
Without a properly installed safety reversing sensor, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
Safety Reversing Sensor
22
Safety Reversing Sensor
WARNING
WARNING
OPERATION
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
2. ALWAYS keep remote controls out of reach of children.
NEVER permit children to operate or play with garage door control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel.
4. ALWAYS keep garage door in sight until completely closed.
NO ONE SHOULD CROSS THE PATH OF THE MOVING
DOOR.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY
OPEN DOOR.
6. If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
8. NEVER use handle to pull garage door open or closed. If rope knot becomes untied, you could fall.
9. If one control (force or travel limits) is adjusted, the other control may also need adjustment.
10. After ANY adjustments are made, the safety reversal system
MUST be tested.
11. Safety reversal system MUST be tested every month.
Garage door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on the floor.
12. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED
(see page 3). An improperly balanced door may not reverse when required and could result in SEVERE INJURY or
DEATH.
13. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician.
14. ALWAYS disconnect electric power to garage door opener
BEFORE making ANY repairs or removing covers.
15.
SAVE THESE INSTRUCTIONS.
Using Your Garage Door Opener
Your opener will operate with up to eight S
AFETY
S
IGNAL
™ remote controls and one S
AFETY
S
IGNAL
™ Keyless Entry System.
Activate your opener with any of the following:
• The hand-held Remote Control: Hold the large push button down until the door starts to move.
•
•
The wall-mounted Door Control: Hold the push button or bar down until the door starts to move.
The Keyless Entry (See Accessories): If provided with your garage door opener, it must be programmed before use. See
Programming.
When the opener is activated (with the safety reversing sensor correctly installed and aligned)
1. If open, the door will close. If closed, it will open.
2. If closing, the door will reverse.
3. If opening, the door will stop.
4. If the door has been stopped in a partially open position, it will close.
5. If obstructed while closing, the door will reverse. If the obstruction interrupts the sensor beam, the opener lights will blink for five seconds.
6. If obstructed while opening, the door will stop.
7. If fully open, the door will not close when the beam is broken.
The sensor has no effect in the opening cycle.
If the sensor is not installed, or is misaligned, the door won’t close from a hand-held remote. However, you can close the door with the Door Control, the Outside Keylock, or Keyless Entry, if you
activate them until down travel is complete. If you release them too soon, the door will reverse.
The opener lights will turn on under the following conditions: when the opener is initially plugged in; when power is restored after interruption; when the opener is activated.
They will turn off automatically after 4-1/2 minutes. Bulb size is
75 watts maximum.
S
AFETY
S
IGNAL
™ light feature: Lights will also turn on when someone walks through the open garage door.
Do not exceed 8 complete cycles of door operation per hour in commercial applications.
23
Using the Wall-Mounted Door Control
Press the push button to open or close the door.
Press again to reverse the door during the closing cycle or to stop the door while it’s opening.
To Open the Door Manually
CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:
FORCE CONTROLS
Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation.
Pages 20 and 21 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully.
LIMIT CONTROLS
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
•
•
•
If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
The door should be fully closed if possible. Pull down on the emergency release handle and lift the door manually.
To reconnect the door to the opener, press the door control push bar.
Emergency
Release
Handle
(Pull Down)
NOTICE
Trolley
Release
Arm
MANUAL DISCONNECT
POSITION
The lockout feature prevents the trolley from reconnecting automatically. Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary. To disengage the lockout feature, pull the handle straight down. The trolley will reconnect on the next UP or DOWN operation.
Trolley
Release
Arm
Emergency
Release Handle
(Down and Back)
NOTICE
LOCKOUT POSITION
Repeat the safety reverse test (Adjustment Step 3, page 22) after any adjustment of limits or force.
MAINTENANCE SCHEDULE
Once a Month
• Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
•
•
Check to be sure door opens & closes fully. Adjust limits and/ or force if necessary. (See pages 20 and 21.)
Repeat the safety reverse test. Make any necessary adjustments. (See Adjustment Step 3.)
Twice a Year
• Check chain tension. Disconnect trolley first. Adjust if necessary (See page 7).
Once a Year
• Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks.
Remote Control Batteries
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• Do NOT recharge, disassemble, heat above 212°F (100°C) or incinerate.
The lithium batteries should produce power for up to 5 years.
To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive side up (+).
Dispose of old battery properly.
Battery positive side up (+)
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
24
Having a Problem?
•
•
1. The opener doesn’t operate from either the Door Control or the remote control:
• Does the opener have electric power? Plug a lamp into the outlet. If it doesn’t light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)
• Have you disabled all door locks? Review installation instruction warnings on page 7.
• Is there a build-up of ice or snow under the door? The door may be frozen to the ground. Remove any restriction.
The garage door spring may be broken. Have it replaced.
Repeated operation may have tripped the overload protector in the motor. Wait 15 minutes and try again.
2. Opener operates from the remote, but not from the
Door Control:
• Is the door control lit? If not, reverse the wires. If the opener runs, check for a faulty wire connection at the door control, a short under the staples, or a broken wire.
• Are the wiring connections correct? Review Installation Step 6, page 12.
3. The door operates from the Door Control, but not from the remote control:
•
•
Is the door push bar flashing? If your model has the Lock feature, make sure it is off.
Program the opener to match the remote control code. (Refer to instructions on the motor unit panel.) Repeat with all remotes.
4. The remote control has short range:
• Change the location of the remote control in your car.
• Check to be sure the antenna on the side or back panel of motor unit extends fully downward.
• Some installations may have shorter range due to a metal door, foil backed insulation, or metal garage siding.
5. Opener noise is disturbing in living quarters of home:
•
6. The garage door opens and closes by itself:
• Be sure that all remote control push buttons are off.
•
If operational noise is a problem because of proximity of the opener to the living quarters, the Vibration Isolator Kit 89LM can be installed. This kit was designed to minimize vibration to the house and is easy to install.
Remove the bell wire from the door control terminals and operate from the remote only. If this solves the problem, the door control is faulty (replace), or there is an intermittent short on the wire between the door control and the motor unit.
• Clear memory and re-program all remote controls.
7. The door doesn’t open completely:
•
•
Is something obstructing the door? Is it out of balance, or are the springs broken? Remove the obstruction or repair the door.
If the door is in good working order but now doesn’t open all the way, increase the up force. See Adjustment Step 2.
• If the door opens at least 5 feet (1.5 m), the travel limits may need to be increased. One turn equals 2" (5 cm) of travel. See
Adjustment Step 1.
Repeat the safety reverse test after the adjustment is complete.
8. The door stops but doesn’t close completely:
• Review the travel limits adjustment procedures on page 20.
Repeat the safety reverse test after any adjustment of door arm length, close force or down limit.
25
9.
•
•
The door opens but won’t close:
If the opener lights blink, check the safety reversing sensor.
See Installation Step 10.
If the opener lights don’t blink and it is a new installation, check the down force. See Adjustment Step 2. For an existing installation, see below.
Repeat the safety reverse test after the adjustment is complete.
10. The door reverses for no apparent reason and opener lights don’t blink:
• Is something obstructing the door? Pull the emergency release handle. Operate the door manually. If it is unbalanced or binding, call a trained door systems technician.
• Clear any ice or snow from the garage floor area where the door closes.
Review Adjustment Step 2.
•
• If door reverses in the fully closed position, decrease the travel limits (Adjustment Step 1).
Repeat safety reverse test after adjustments to force or travel limits. The need for occasional adjustment of the force and limit settings is normal. Weather conditions in particular can affect door travel.
11. The door reverses for no apparent reason and opener lights blink for 5 seconds after reversing:
• Check the safety reversing sensor. Remove any obstruction or align the receiving eye. See Installation Step 10.
12. The opener lights don’t turn on:
• Replace the light bulbs (75 watts maximum). Use a standard neck garage door opener bulb if regular bulb burns out.
13. The opener lights don’t turn off:
• Is the Light feature on? Turn it off.
14. The opener strains or maximum force is needed to operate door:
• The door may be out of balance or the springs may be broken. Close the door and use the emergency release handle to disconnect the trolley. Open and close the door manually. A properly balanced door will stay in any point of travel while being supported entirely by its springs. If it does not, disconnect the opener and call a trained door systems technician. Do not increase the force to operate the opener.
15. The opener motor hums briefly, then won’t work:
•
•
The garage door springs may be broken. See above.
If the problem occurs on the first operation of the opener, door may be locked. Disable the door lock.
Repeat the safety reverse test after the adjustment is complete.
16. The opener won’t operate due to power failure:
•
•
Use the emergency release handle to disconnect the trolley.
The door can be opened and closed manually. When power is restored, press the Door Control push bar and trolley will automatically reconnect (unless trolley is in lockout position.)
See page 24.
The Outside Quick Release accessory (for use on garages with no service door) disconnects the trolley from outside the garage in case of power failure.
17. The chain droops or sags:
• It is normal for the chain to droop slightly in the closed door position. Use the emergency release rope and handle to disconnect the trolley. If the chain returns to the normal height when the trolley is disengaged, and the door reverses on a 2x4 laid flat, no adjustments are needed. (See page 7.)
PROGRAMMING
NOTICE: If this S
AFETY
S
IGNAL
™ garage door opener is operated with a non-rolling code transmitter, the technical measure in the receiver of the garage door opener, which provides security against code-theft devices, will be circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non-rolling code transmitter to circumvent that technical measure.
S
AFETY
S
IGNAL
™ 3-Button Remote Control Programming (Optional)
The 300 Series remote control works only with door openers and light controls having a purple “Learn” button.
Programming instructions are described and illustrated below.
The additional push buttons can also activate other garage door openers and/or light controls. (Instructions for programming light products are included with those accessories.)
Instructions are Described and Illustrated Below
1 2 3
KG KG
To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:
• ALWAYS keep remote controls out of reach of children.
NEVER permit children to operate, or play with remote control transmitters.
• Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
• ALWAYS keep gate or garage door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door.
1 2
1. Press and release the “learn” button on the motor unit. The learn indicator light will glow steadily for 30 seconds.
2. Within 30 seconds, press and hold the button on the hand-held remote.
3. Release the button when the motor unit light blinks. It has learned the code. If light bulbs are not installed, two clicks will be heard.
2
KG KG
Open/Close/Stop Operation
Your S
AFETY
S
IGNAL
™ remote control can be programmed to operate one door using all
3 buttons: the large button will only open the door, the middle button will close the door and third button will stop the door’s movement. You may set up this feature as follows:
Open
Close
Stop
1. With the door closed, press and hold the large remote push button.
2. Press and hold the Lock button on the door control.
3. Press and hold the door control push bar.
When the opener lights flash, release all buttons. Test by pressing the large (Open) button on the remote. The door should open.
Press it again while the door is open and nothing should happen.
Press the middle (Close ) button and the door should close. Press the third (Stop) button while the door is moving and it should stop immediately.
To Erase All Codes From Motor Unit Memory
To deactivate any unwanted remote, first erase all codes:
Press and the hold “learn” button on motor unit until the learn indicator light goes out (approximately 6 seconds). All previous codes are now erased. Reprogram each remote or keyless entry you wish to use.
To Control the Opener Lights
With S
AFETY
S
IGNAL
™ transmitters, a remote push button can be programmed to operate the opener lights without opening the door.
1. With the door closed, press and hold the remote button that you want to control the light.
2. Press and hold the Light button on the door control.
3. Press and hold the Lock button on the door control.
4. After the opener lights flash, release all buttons.
Test by pressing the remote push button. The opener lights should turn on or off but the door should not move.
26
To Add or Change a Keyless Entry PIN (Optional)
NOTE: Your new Keyless Entry must be programmed to operate your garage door opener.
USING THE “LEARN” BUTTON
1
1 2 3
KG KG
2
To change an existing, known PIN
If the existing PIN is known, it may be changed by one person without using a ladder.
1. Press the four buttons for the present PIN, then press and hold the # button.
The opener light will blink twice. Release the # button.
1. Press and release the “learn” button on motor unit. The learn indicator light will glow steadily for 30 seconds.
2. Within 30 seconds, enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold the ENTER button.
3. Release the button when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard.
2
KG
KG
The motor unit lights will blink once when the PIN has been learned.
Test by pressing the new PIN, then press ENTER. The door should move.
To set a temporary PIN
You may authorize access by visitors or service people with a temporary 4-digit PIN. After a programmed number of hours or number of accesses, this temporary PIN expires and will no longer open the door. It can be used to close the door even after it has expired. To set a temporary PIN:
1. Press the four buttons for your personal entry PIN (not the last temporary PIN), then press and hold the ✽ button.
The opener light will blink three times. Release the button.
2. Press the temporary 4-digit PIN you have chosen, then press
ENTER.
The opener light will blink four times.
3. To set the number of hours this temporary PIN will work, press the number of hours (up to 255), then press ✽.
OR
3. To set the number of times this temporary PIN will work, press the number of times (up to 255), then press #.
The opener light will blink once when the temporary PIN has been learned.
Test by pressing the four buttons for the temporary PIN, then press ENTER. The door should move. If the temporary PIN was set to a certain number of openings, remember that the test has used up one opening.To clear the temporary password, repeat steps
1-3, setting the number of hours or times to 0 in step 3.
27
Multi-Function Door Control (Optional)
INSTALLATION
Locate door control within sight of the door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of the door and door hardware. If installing into drywall, drill 5/32" holes and use anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box. NOTE: After installation, a green indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct).
1. Strip 1/4" (6 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to 2 and white/red wire to 1.
To prevent possible SERIOUS INJURY OR DEATH from electrocution:
• Be sure power is not connected BEFORE installing door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
• Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
2. Remove cover by gently pushing both thumbs against upper corners of cover on back side of door control. Fasten with
6ABx1-1/4" self-tapping screws (standard installation) or
6-32x1" machine screws (into gang box) as follows:
• Drill and install bottom screw, allowing 1/8" (3 mm) to protrude above wall surface.
3.
4.
• Position bottom of door control on screw head and slide
•
• down to secure. Adjust screw for snug fit.
Install top screw with care to avoid cracking plastic housing.
DO NOT overtighten.
Insert bottom tabs and snap on cover. (To remove cover after mounting, gently pry at top with paper clip or small flat head screwdriver.)
(Standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit.
Connect bell wire to the opener terminal screws: white to 2 and white/red to 1.
OPERATION OF THE MULTI-FUNCTION DOOR CONTROL
Press the push button to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while
Lighted
Push Button it’s opening.
Lock
Button
Light feature
LOCK
LIGHT
Light
Button
Press the Light button to turn the opener light on or off. It will not control the opener lights when the door is in motion. If you turn it on and then activate the opener, the light will remain on for 4-1/2 minutes.
Press again to turn it off sooner. The 4-1/2 minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold the Lock button until the light blinks (about 10 seconds).
A single blink indicates that the timer is reset to 1-1/2 minutes.
Repeat the procedure and the light will blink twice, resetting the timer to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval, etc., up to a maximum of four blinks and 4-1/2 minutes.
5. Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in a prominent location on inside of garage door.
NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned. See Safety Reversing Sensor Instructions beginning on page 15.
Lock feature
Designed to prevent operation of the door from hand-held remote controls. However, the door will open and close from the Door
Control, the Outside Keylock and the Keyless Entry Accessories.
To activate, press and hold the Lock button for 2 seconds. The push bar light will flash as long as the Lock feature is on.
To turn off, press and hold the Lock button again for 2 seconds.
The push bar light will stop flashing. The Lock feature will also turn off whenever the “learn” button on the
Opener Terminal Screws motor unit panel is activated.
Multi-Function
Door Control Panel
Terminal Screws
1 2 3
RED WHT
1 2
Door Control
Push Bar
9
7
5
KG
3
1
9
7
5
KG
3
1
2-Conductor
Bell Wire
Lock
Button
LOCK
LIGHT
Light Button Opener Panel
28
Antenna
REPAIR PARTS
Rail Assembly Parts
3
1
2
Installation Parts
1
5
2
NOTICE
3
6
CEILING MOUNT ONLY
UP
7 9
10
8
11 12
5
4
2
3
4
KEY PART
NO. NO.
1 4A1008
41A2780
41A3489
CD1008
CD1010
CD1012
DESCRIPTION
Master link kit
Chain pulley bracket
Complete trolley assembly
8 Foot (2.44 m) Rail Assy.
10 Foot (3.05 m) Rail Assy.
12 Foot (3.66 m) Rail Assy.
CD1014 14 Foot (4.27 m) Rail Assy.
5 83A11 Rail
6 41C771 Center Bracket (1 pc.)
4
KEY PART
NO. NO.
1
2
41A4166
3
DESCRIPTION
Door control push button
41B4494-1 2-conductor bell wire, white & white/red
41A2828 Emergency release rope & handle assembly
4
5
6
7
12B380
41A4353
41A4373A
Door bracket plate
Header bracket w/clevis pin & fastener
Safety sensor kit
(receiving and sending eyes) with 3'
(0.9 m) 2-conductor bell wire attached
Curved door arm section 8
9
10
178B35
12B483
178B34
178B73
12B484 11
12 12B485
C Wrap bracket
Straight door arm section
Straight door arm section
(14' [4.27 m] door)
Square hole mounting bracket
Slotted mounting bracket
41A2770
41A4116
Installation hardware bag (page 5).
Safety sensor hardware
114A3156SP Owner’s manual - Spanish
29
Motor Unit Assembly Parts
1
3
4
2
18
18
15
17
16
9
7
8
5
6
15
LIMIT SWITCH ASSY.
14
(Down)
Contact
Brown
Wire
Drive
Gear
Center Limit
Contact
(Up)
Contact
Grey
Wire
Yellow
Wire
13
11
12
10
5
6
7
KEY PART
NO. NO.
1 41C5069
2
3
4
DESCRIPTION
Rail support bracket assembly kit
41A5668
41A2817
Gear and sprocket assembly.
Complete with: Spring washer, thrust washer, retaining washer, bearing plate roll pins (2), drive gear and worm gear, helical gear w/retainer and grease,sprocket shaft plate with screws
Drive/worm gear kit w/grease
Roll pins (2)
143D100-1 Front end panel
30B532 Capacitor
8
9 41A3150 Terminal block with screws
11
12
13
14
15
16
17
18
KEY PART
NO. NO.
10
DESCRIPTION
41D4509 Replacement motor & bracket assembly
Complete with: Motor, worm, bracket, bearing assembly
41A4593-5 Cover
81C253
41A5640
41C4398A
Helical gear & retainer w/grease
Limit switch assembly
RPM sensor assembly
41C4246
41A2826
Wire harness assembly w/plug
Shaft bearing kit
41A2822A Interrupter cup assembly
41A5021-9G-315 Receiver logic board assembly
Complete with: Logic board, end panel with all labels
41A2825 Opener assembly hardware kit
(includes screws not designated by a number in illustration).
30
ACCESSORIES
1702LM Outside Quick Release:
Required for a garage with NO access door.
Enables homeowner to open garage door manually from outside by disengaging trolley.
371RGD
180C139 NEMA 1 Push Button:
Heavy Duty Door Control Push Button (one button).
372RGD
S
AFETY
S
IGNAL
™ 1-Button
Remote Control:
Includes visor clip.
S
AFETY
S
IGNAL
™ 2-Button
Remote Control:
Includes visor clip.
CD1008
CD1010
CD1012
CD1014
108D36
8 Foot (2.44 m) Complete Rail:
To allow an 8 foot (2.44 m) door to open fully.
373RGD S
AFETY
S
IGNAL
™ 3-Button
Remote Control:
Includes visor clip.
10 Foot (3.05 m) Complete Rail:
To allow a 10 foot (3.05 m) door to open fully.
370LM
12 Foot (3.66 m) Complete Rail:
To allow a 12 foot (3.66 m) door to open fully.
78LM
LOCK
LIGHT
376LM
14 Foot (4.27 m) Complete Rail:
To allow a 14 foot (4.27 m) door to open fully.
Light Lens Cover:
Attractive lens cover protects light bulbs and diffuses light to every corner of your garage.
50111
3-Button Mini-Remote
Control with SECURITY✚ ® :
With key ring and fastening strip.
Multi-Function Door Control Panel:
Provides a Lock Feature which prevents operation of garage door opener from portable remotes and a Light Feature for constant light.
SECURITY✚ ® Keyless Entry:
Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons. This temporary password can be limited to a programmable number of hours or entries.
Center Bracket (6 pcs.):
Adds additional stability to a rail by enabling the use of additional hanging brackets if desired.
31
RAYNOR SERVICE IS
ON CALL
OUR LARGE SERVICE ORGANIZATION
SPANS AMERICA
INSTALLATION AND SERVICE INFORMATION
IS AS NEAR AS YOUR TELEPHONE
SIMPLY DIAL OUR TOLL FREE NUMBER:
1-800-472-9667
HOURS: (Central Std. Time)
7:00 A.M. TO 6:00 P.M. - Monday through Friday www.raynor.com
For professional installation, parts and service, contact your local RAYNOR GARAGE DOOR DISTRIBUTOR. Look for him in the Yellow Pages, or visit our Dealer Locator on our Website
HOW TO ORDER
REPAIR PARTS
Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed accordingly.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:
• PART NUMBER
• PART NAME
• MODEL NUMBER
ADDRESS ORDERS TO:
RAYNOR GARAGE DOORS
Technical Support Group
6050 S. Country Club Road
Tucson, Arizona 85706
SERVICE INFORMATION
TOLL FREE NUMBER:
1-888-528-6306
RAYNOR ONE YEAR LIMITED WARRANTY
LIFETIME MOTOR LIMITED WARRANTY
Raynor (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of one year from the date of purchase [and that the motor is free from defect in materials and/or workmanship for the lifetime of the product]. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-888-528- 6306, toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call.
Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE ONE YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED
WARRANTIES WITH RESPECT TO THE MOTOR, WHICH ARE LIMITED IN DURATION TO THE LIFETIME LIMITED WARRANTY PERIOD FOR THE MOTOR],
AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER
INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY
MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED
UNIT, REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING
BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY
PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD
RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE,
OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR
STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN
CONNECTION WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
114A3156C
© 2010, The Chamberlain Group, Inc.
All Rights Reserved
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Owner’s Manual
- 2 TABLE OF CONTENTS
- 2 INTRODUCTION
- 2 Safety Symbol and Signal Word Review
- 3 Preparing your garage door
- 3 Tools needed
- 4 Planning
- 5 Carton Inventory
- 6 ASSEMBLY
- 6 STEP 1 Attach the Rail to the Motor Unit
- 6 STEP 2 Attach the Chain to the Sprocket and Install the Rail Support Bracket
- 7 STEP 3 Tighten the Chain
- 7 INSTALLATION
- 8 STEP 1 Determine the Header Bracket Location
- 9 STEP 2 Install the Header Bracket
- 10 STEP 3 Attach the Rail to the Header Bracket
- 11 STEP 4 Position the Opener
- 11 STEP 5 Hang the Opener
- 12 STEP 6 Install the Door Control
- 13 STEP 7 Install the Light
- 13 STEP 8 Attach the Emergency Release Rope and Handle
- 14 STEP 9 Electrical Requirements
- 15 STEP 10 Install The Protector System
- 18 STEP 11 Fasten the Door Bracket
- 19 STEP 12 Connect Door Arm to Trolley
- 20 ADJUSTMENT
- 20 STEP 1 Adjust the UP and DOWN Travel Limits
- 21 STEP 2 Adjust the Force
- 22 STEP 3 Test the Safety Reversal System
- 22 STEP 4 Test the Protector System®
- 23 OPERATION
- 23 Using Your Garage Door Opener
- 24 Using the Wall-Mounted Door Control
- 24 To Open the Door Manually
- 24 CARE OF YOUR OPENER
- 25 Having a Problem?
- 26 PROGRAMMING
- 26 SAFETY SIGNALTM 3-Button Remote Control Programming (Optional)
- 27 To Add or Change a Keyless Entry PIN (Optional)
- 28 Multi-Function Door Control (Optional)
- 29 REPAIR PARTS
- 29 Rail Assembly Parts
- 29 Installation Parts
- 30 Motor Unit Assembly Parts
- 31 ACCESSORIES
- 32 WARRANTY
- 1 Spanish