Electrolux E23CS78HSS - 22.6 cu. Ft.: The Adaptive Defrost Control automatically adjusts defrost cycles to optimize energy efficiency and food preservation, while the variable-speed compressor delivers precise cooling and energy savings. With a generous 22.6 cu. ft. of storage space, this refrigerator offers ample room for all your groceries.
advertisement
SERVICE DATA SHEET
241639000
ICE & WATER - AUTOMATIC DEFROST
Type A with Run/Start Capacitor
Operating Time
PERFORMANCE DATA
NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Freezer Temperature
Refrigerator Temperature
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle)
Amps (running)
Base Voltage
65°F (18°C) Ambient
Variable Speed Standard
74 to 84%
-2° to 2°F
-19° to -17°C
32 to 40%
0° to 4°F
-18° to -16°C
34° to 39°F
1° to 4°C
5 to 12 psig
43 to 83 kPa
-2 to 2 psig
-14 to 14kPa
90 to 105 psig
621 to 724 kPa
60 to 65
34° to 39°F
1° to 4°C
5 to 12 psig
43 to 83 kPa
-2 to 2 psig
-14 to 14kPa
90 to 115 psig
621 to 793 kPa
120 to 150
.7 to 1.1 1.0 to 1.4
115 vac (127 vac max)
DEFROST SPECIFICATIONS
90°F (32°C) Ambient
Variable Speed Standard
100%
-1° to 3°F
-18° to -16°C
34° to 39°F
1° to 4°C
N/A
55 to 65%
-1° to 3°F
-18° to -16°C
34° to 39°F
1° to 4°C
5 to 12 psig
43 to 83 kPa
-2 to 2 psig
-14 to 14kPa
120 to 135 psig
827 to 931 kPa
65 to 80
-2 to 2 psig
-14 to 14kPa
130 to 155 psig
896 to 1069 kPa
130 to 160
.9 to 1.3 1.1 to 1.5
115 vac (127 vac max)
COUNTER DEPTH SIDE BY SIDE - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
Cabinet Size
2.8
Thermostat Heater
Cut-in Cut-out Watts Ohms
Electronic Timer – (ADC) Defrost 24 minutes every 6 – 96 hours of compressor run time.
CONDENSER FAN MOTOR
950 CW Opposite Shaft
ICE MAKER SPECIFICATIONS
.1 Running
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at
200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
Electrical
Thermostat
Heater Voltage
Wire Number
1
2
3
4
115 vac (127 vac max)
Opens at 48°F (9°C) Closes at 15°F (-9°C)
NOTE
85 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
This product comes equipped with an Adaptive Defrost
Wire Color Connects to: Control (ADC). To activate manual defrost, press and hold the Freezer temperature UP (WARMER) key while pressing
Light Blue Neutral
IMPORTANT
Please return this sheet to its original location.
within 6 seconds. A “d” in the freezer temperature window and “F” in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, press and hold Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key
5 times within 6 seconds. “d” and “F” will be displayed until the defrost cycle is complete. (approx. 8 minutes)
ICE MAKER INFORMATION
Test Cycling
Press the momemtary contact on the ON/OFF switch for approximately 15 seconds. Ice maker will continue to complete the cycle.
Water Fill Volume
Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. The water fill adjustment screw will
Motor
Gear
Water Fill
Adjustment
TUR
N
Mounting
Plate
Screws
Ice Maker
ON/OFF
Switch change the fill time.
One turn is equal to
Mounting
Plate
Screw
Timing
Gear 20cc (.68 oz.). The correct fill is 102 to
110cc (3.25 to 3.5 oz.). When a water valve is replaced, the fill volume must be checked.