Electrolux E23CS78HSS - 22.6 cu. Ft Service Data Sheet


Add to my manuals
2 Pages

advertisement

Electrolux E23CS78HSS - 22.6 cu. Ft Service Data Sheet | Manualzz

SERVICE DATA SHEET

241639000

ICE & WATER - AUTOMATIC DEFROST

Type A with Run/Start Capacitor

Operating Time

PERFORMANCE DATA

NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING

Freezer Temperature

Refrigerator Temperature

Low Side Pressure (cut-in)

Low Side Pressure (cut-out)

High Side Pressure (last 1/3 cycle)

Wattage (last 1/3 cycle)

Amps (running)

Base Voltage

65°F (18°C) Ambient

Variable Speed Standard

74 to 84%

-2° to 2°F

-19° to -17°C

32 to 40%

0° to 4°F

-18° to -16°C

34° to 39°F

1° to 4°C

5 to 12 psig

43 to 83 kPa

-2 to 2 psig

-14 to 14kPa

90 to 105 psig

621 to 724 kPa

60 to 65

34° to 39°F

1° to 4°C

5 to 12 psig

43 to 83 kPa

-2 to 2 psig

-14 to 14kPa

90 to 115 psig

621 to 793 kPa

120 to 150

.7 to 1.1 1.0 to 1.4

115 vac (127 vac max)

DEFROST SPECIFICATIONS

90°F (32°C) Ambient

Variable Speed Standard

100%

-1° to 3°F

-18° to -16°C

34° to 39°F

1° to 4°C

N/A

55 to 65%

-1° to 3°F

-18° to -16°C

34° to 39°F

1° to 4°C

5 to 12 psig

43 to 83 kPa

-2 to 2 psig

-14 to 14kPa

120 to 135 psig

827 to 931 kPa

65 to 80

-2 to 2 psig

-14 to 14kPa

130 to 155 psig

896 to 1069 kPa

130 to 160

.9 to 1.3 1.1 to 1.5

115 vac (127 vac max)

COUNTER DEPTH SIDE BY SIDE - R134a

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.

IMPORTANT

If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.

Cabinet Size

2.8

Thermostat Heater

Cut-in Cut-out Watts Ohms

Electronic Timer – (ADC) Defrost 24 minutes every 6 – 96 hours of compressor run time.

CONDENSER FAN MOTOR

950 CW Opposite Shaft

ICE MAKER SPECIFICATIONS

.1 Running

CAUTION

All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at

200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.

Electrical

Thermostat

Heater Voltage

Wire Number

1

2

3

4

115 vac (127 vac max)

Opens at 48°F (9°C) Closes at 15°F (-9°C)

NOTE

85 vac

ICE MAKER CONNECTOR PLUG CONNECTIONS

This product comes equipped with an Adaptive Defrost

Wire Color Connects to: Control (ADC). To activate manual defrost, press and hold the Freezer temperature UP (WARMER) key while pressing

Light Blue Neutral

IMPORTANT

Please return this sheet to its original location.

within 6 seconds. A “d” in the freezer temperature window and “F” in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, press and hold Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key

5 times within 6 seconds. “d” and “F” will be displayed until the defrost cycle is complete. (approx. 8 minutes)

ICE MAKER INFORMATION

Test Cycling

Press the momemtary contact on the ON/OFF switch for approximately 15 seconds. Ice maker will continue to complete the cycle.

Water Fill Volume

Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. The water fill adjustment screw will

Motor

Gear

Water Fill

Adjustment

TUR

N

Mounting

Plate

Screws

Ice Maker

ON/OFF

Switch change the fill time.

One turn is equal to

Mounting

Plate

Screw

Timing

Gear 20cc (.68 oz.). The correct fill is 102 to

110cc (3.25 to 3.5 oz.). When a water valve is replaced, the fill volume must be checked.