American Standard Cadet 3 FloWise Tall Height Round Toilet Bowl Only in Linen Installation guide
Add to my manuals
1 Pages
advertisement
CADET
®
3 RIGHT HEIGHT
®
ROUND FRONT TOILET 10" ROUGH-IN
VITREOUS CHINA
BARRIER FREE
CADET ® 3 RIGHT HEIGHT ®
ROUND FRONT TOILET 10" ROUGH-IN
❑ 270BB.101
• Features the Cadet ® Flushing System
• Vitreous china
• High Efficiency Toilet (HET), ultra-low consumption
(4.8 Lpf/1.28 gpf) utilizes 20% less water
• PowerWash ® rim scrubs bowl with each flush
• Includes color match bowl caps
• EverClean ® surface included
• 3" flush valve
• 2-1/8" trapway
• 16-1/2" rim height for accessible applications
• 10" (254mm) rough-in
• Generous 9" x 8" water surface area
• Chrome finish trip lever is supplied
• 1,000g MaP Score** at 1.28 gpf
• 5 year warranty
❑ 3717B.001 Right Height ® Round Front Bowl
❑ 4019.101N Tank
Nominal Dimensions:
717 x 439 x 770mm (28-1/4" x 17-1/4" x 30-1/4")
Fixture only, seat and supply sold separately
FINISHED WALL
30 ± 6mm
(1-1/8" ± 1/4")
190mm
(7-1/2")
667mm
(26-1/4")
439mm
(17-1/4")
Compliance Certifications -
Meets or Exceeds the Following Specifications:
• ASME A112.19.2-2008/CSA B45.1-08 for Vitreous
China Fixtures
• US EPA WaterSense ® Specification for HETs 92mm (3-5/8")
419mm
(16-1/2")
C/L OF SEAT POST HOLES
140mm (5-1/2" CENTERS)
419mm
(16-1/2")
SUPPLY
AS
REQ'D.
*203mm
(8")
356mm
(14")
770mm
(30-1/4")
** Maximum Performance (MaP) testing performed by
IAPMO R&T Lab. MaP Report conducted by Veritec
Consulting, Inc. and Koeller and Company.
216mm
(8-1/2")
254mm
(10")
328mm
(13")
C/L OF OUTLET
FINISHED
FLOOR
237mm
(9-3/8")
*152mm
(6")
To Be Specified:
❏ Color: ❏ White ❏ Bone ❏ Linen
❏ Seat: #5320.110 EverClean ® Round Front Seat with
Slow Close Snap-Off Hinges
❏ Supply with stop:
NOTES:
THIS TOILET IS DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION OF
254MM (10") FROM FINISHED WALL TO C/L OF OUTLET.
SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY.
* DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2.
These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND
ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES-CHECK LOCAL CODES.
K221
Certified by
IAPMO R&T
© 2013 AS America Inc.
Rev. 8/13