HP (Hewlett-Packard) | 675422-001 | 722547-001 | User manual | HP ProLiant DL320e Gen8 Server User Guide Abstract


Add to my manuals
103 Pages

advertisement

HP (Hewlett-Packard) | 675422-001 | 722547-001 | User manual | HP ProLiant DL320e Gen8 Server User Guide Abstract | Manualzz

HP ProLiant DL320e Gen8 Server

User Guide

Abstract

This document is for the person who installs, administers, and troubleshoots servers and storage systems. This document is intended for experienced

IT professionals or end-users with no or prior hardware setup experience. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.

Part Number: 682822-001

September 2012

Edition: 1

© Copyright 2012 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation.

Intel® Xeon®, Pentium®, and Intel® Core™ are trademarks of Intel Corporation in the U.S. and other countries.

Bluetooth® is a trademark owned by its proprietor and used by Hewlett-Packard Company under license.

Contents

Component identification ............................................................................................................... 7

Front panel components ............................................................................................................................. 7

Front panel LEDs and buttons ............................................................................................................ 8

Rear panel components .............................................................................................................................. 8

Rear panel LEDs and buttons ............................................................................................................. 9

System board components ........................................................................................................................ 10

DIMM slot locations ....................................................................................................................... 11

PCIe riser board slot definitions ....................................................................................................... 11

System maintenance switch ............................................................................................................. 11

NMI header .................................................................................................................................. 12

System board LED definitions .......................................................................................................... 12

Drive numbering ..................................................................................................................................... 13

Drive LED definitions ................................................................................................................................ 13

FBWC module LED definitions ................................................................................................................... 14

Fan locations .......................................................................................................................................... 15

T-10/T-15 Torx screwdriver ...................................................................................................................... 16

Operations ................................................................................................................................. 17

Power up the server ................................................................................................................................. 17

Power down the server ............................................................................................................................. 17

Extend the server from the rack ................................................................................................................. 17

Remove the server from the rack ................................................................................................................ 18

Remove the security bezel (optional) .......................................................................................................... 19

Remove the access panel.......................................................................................................................... 19

Install the access panel............................................................................................................................. 20

Remove the air baffle ............................................................................................................................... 20

Install the air baffle .................................................................................................................................. 21

Remove the PCI riser cage ........................................................................................................................ 21

Install the PCI riser cage ........................................................................................................................... 22

Setup ......................................................................................................................................... 24

Optional installation services .................................................................................................................... 24

Rack planning resources........................................................................................................................... 24

Optimum environment .............................................................................................................................. 24

Space and airflow requirements ...................................................................................................... 25

Temperature requirements ............................................................................................................... 25

Power requirements ....................................................................................................................... 26

Electrical grounding requirements .................................................................................................... 26

Server warnings and cautions ................................................................................................................... 26

Rack warnings ........................................................................................................................................ 27

Identifying the contents of the server shipping carton .................................................................................... 28

Installing hardware options ....................................................................................................................... 28

Installing the server into the rack ................................................................................................................ 28

Installing the operating system................................................................................................................... 30

Powering on and selecting boot options ..................................................................................................... 30

Registering the server ............................................................................................................................... 31

Contents 3

Hardware options installation ....................................................................................................... 32

Introduction ............................................................................................................................................ 32

Security bezel option ............................................................................................................................... 32

Drive options .......................................................................................................................................... 32

Drive installation guidelines ............................................................................................................ 33

Installing a non-hot-plug drive .......................................................................................................... 33

Installing a hot-plug drive ................................................................................................................ 34

Mini-SAS cable option ............................................................................................................................. 35

Controller options .................................................................................................................................... 38

Installing a storage controller .......................................................................................................... 38

Installing the FBWC module and capacitor pack ............................................................................... 39

Optical drive option ................................................................................................................................ 41

Memory options ...................................................................................................................................... 44

HP SmartMemory .......................................................................................................................... 45

DIMM identification ....................................................................................................................... 45

Single-rank and dual-rank DIMMs .................................................................................................... 46

Memory subsystem architecture ....................................................................................................... 46

General DIMM slot population guidelines ......................................................................................... 46

Installing a DIMM .......................................................................................................................... 47

Expansion board options .......................................................................................................................... 48

Dedicated iLO management port option ..................................................................................................... 49

Enabling the dedicated iLO management port ................................................................................... 51

HP Trusted Platform Module option ............................................................................................................ 51

Installing the Trusted Platform Module board ..................................................................................... 52

Retaining the recovery key/password .............................................................................................. 53

Enabling the Trusted Platform Module ............................................................................................... 53

Cabling ..................................................................................................................................... 55

Cabling overview .................................................................................................................................... 55

Storage cabling ...................................................................................................................................... 55

Four-bay LFF non-hot-plug drive cage cabling .................................................................................... 55

Four-bay LFF hot-plug drive cage cabling .......................................................................................... 57

Eight-bay SFF hot-plug drive cage cabling......................................................................................... 58

Optical drive cabling ............................................................................................................................... 59

Power supply cabling............................................................................................................................... 60

Nonredundant power supply cabling ............................................................................................... 60

Redundant power supply cabling ..................................................................................................... 61

Software and configuration utilities ............................................................................................... 62

Server mode ........................................................................................................................................... 62

Server QuickSpecs .................................................................................................................................. 62

HP iLO Management Engine ..................................................................................................................... 62

HP iLO ......................................................................................................................................... 62

Intelligent Provisioning .................................................................................................................... 64

HP Insight Remote Support software ................................................................................................. 66

Scripting Toolkit ............................................................................................................................ 66

HP Service Pack for ProLiant ..................................................................................................................... 67

HP Smart Update Manager ............................................................................................................. 67

HP ROM-Based Setup Utility ..................................................................................................................... 67

Using RBSU .................................................................................................................................. 68

Auto-configuration process .............................................................................................................. 68

Boot options ................................................................................................................................. 69

Re-entering the server serial number and product ID ........................................................................... 69

Utilities and features ................................................................................................................................ 69

Contents 4

Array Configuration Utility .............................................................................................................. 69

Option ROM Configuration for Arrays ............................................................................................. 70

ROMPaq utility .............................................................................................................................. 71

Automatic Server Recovery ............................................................................................................. 71

USB support .................................................................................................................................. 71

Redundant ROM support ................................................................................................................ 71

Keeping the system current ....................................................................................................................... 72

Drivers ......................................................................................................................................... 72

Software and firmware ................................................................................................................... 72

Version control .............................................................................................................................. 72

HP Operating Systems and Virtualization Software Support for ProLiant Servers ..................................... 73

Change control and proactive notification ........................................................................................ 73

Troubleshooting .......................................................................................................................... 74

Troubleshooting resources ........................................................................................................................ 74

System battery replacement .......................................................................................................... 75

Regulatory compliance notices ..................................................................................................... 77

Regulatory compliance identification numbers ............................................................................................. 77

Federal Communications Commission notice ............................................................................................... 77

FCC rating label ............................................................................................................................ 77

FCC Notice, Class A Equipment ...................................................................................................... 77

FCC Notice, Class B Equipment ...................................................................................................... 77

Declaration of conformity for products marked with the FCC logo, United States only ....................................... 78

Modifications .......................................................................................................................................... 78

Cables ................................................................................................................................................... 78

Canadian notice (Avis Canadien) .............................................................................................................. 78

European Union regulatory notice ............................................................................................................. 79

Disposal of waste equipment by users in private households in the European Union ......................................... 79

Japanese notice ...................................................................................................................................... 80

BSMI notice ............................................................................................................................................ 80

Korean notice ......................................................................................................................................... 80

Chinese notice ........................................................................................................................................ 81

Vietnam compliance marking notice .......................................................................................................... 81

Ukraine notice ........................................................................................................................................ 81

Laser compliance .................................................................................................................................... 81

Battery replacement notice ........................................................................................................................ 82

Taiwan battery recycling notice ................................................................................................................. 82

Power cord statement for Japan ................................................................................................................. 82

Acoustics statement for Germany (Geräuschemission) .................................................................................. 83

Electrostatic discharge ................................................................................................................. 84

Preventing electrostatic discharge .............................................................................................................. 84

Grounding methods to prevent electrostatic discharge .................................................................................. 84

Specifications ............................................................................................................................. 85

Environmental specifications ..................................................................................................................... 85

Server specifications ................................................................................................................................ 85

Power supply specifications ...................................................................................................................... 85

HP 350 W 1U Factory Integrated Power Supply ................................................................................ 85

HP 460 W CS Gold Hot-plug Power Supply (92% efficiency) .............................................................. 86

HP 460 W CS Platinum Plus Hot-plug Power Supply (94% efficiency) ................................................... 86

Hot-plug power supply calculations .................................................................................................. 87

Contents 5

Support and other resources ........................................................................................................ 88

Before you contact HP .............................................................................................................................. 88

HP contact information ............................................................................................................................. 88

Customer Self Repair ............................................................................................................................... 88

Acronyms and abbreviations ........................................................................................................ 96

Documentation feedback ........................................................................................................... 100

Index ....................................................................................................................................... 101

Contents 6

Component identification

Front panel components

Four-bay LFF drive model

Item

1

2

3

4

Description

Optical drive

Serial label pull tab

USB connectors

LFF drives

Eight-bay SFF drive model

Item

1

2

3

4

Description

Optical drive

USB connectors

Serial label pull tab

SFF drives

Component identification 7

Front panel LEDs and buttons

Item Description

1

UID LED/button

2

3

4

Power On/Standby button and system power LED

Health LED

NIC status LED

Status

Blue = Identification is activated.

Flashing blue = System is being managed remotely.

Off = Identification is deactivated.

Green = System is on.

Flashing green = Waiting for power.

Amber = System is in standby, but power is still applied.

Off = Power cord is not attached or power supply failed.

Green = System is on and system health is normal.

Flashing amber = System health is degraded.

Flashing red = System health is critical.

Off = System is off.

Green = Linked to network

Flashing green = Network activity

Off = No network link

Rear panel components

Component identification 8

8

9

10

11

6

7

4

5

2

3

Item Description

1

Slot 2 PCIe x16 (16, 8, 4, 1)*

Slot 1 PCIe x8 (4, 1)*

Power supply 1

Power supply 2

Dedicated iLO management port (optional)

UID LED button

Serial connector

Video connector

USB connectors

NIC 1/shared iLO management connector

NIC connector 2

* For more information on the riser board slots supported by the onboard PCI riser connectors, see "PCIe riser

board slot definitions (on page 11 )."

Rear panel LEDs and buttons

Item

1

2

3

4

Description

NIC link LED

Status

Green = Link exists

Off = No link exists

NIC status LED

UID LED/button

Power supply LED

(for hot-plug HP CS power supplies only)

Green = Activity exists

Flashing green = Activity exists

Off = No activity exists

Blue = Identification is activated

Flashing blue = System is being managed remotely

Off = Identification is deactivated

Green = Normal

Off = One or more of the following conditions exists:

Power is unavailable

Power supply failed

Power supply is in standby mode

Power supply error

Component identification 9

System board components

16

17

18

19

12

13

14

15

20

21

6

7

4

5

1

2

3

8

9

10

11

Item Description

PCI riser connectors*

SD card slot

System maintenance switch

NMI header

SATA connector

Mini-SAS connector

4-pin power supply connector

Front panel connectors

Internal USB connector

Fan connector 4

Fan connector 3

System battery

Fan connector 2

Discovery service connector

Fan connector 1

24-pin power supply connector

26-pin RPS connector

Processor socket

DIMM slots

TPM connector

Dedicated iLO module connector

* For more information on the riser board slots supported by the onboard PCI riser connectors, see "PCIe riser

board slot definitions (on page 11 )."

Component identification 10

DIMM slot locations

DIMM slots are numbered sequentially (1 through 4) for the processor. The supported AMP modes use the letter assignments for population guidelines

PCIe riser board slot definitions

The transfer rate of the PCIe riser board slot 2 depends on the processor model installed. The slot can either run in PCIe2 (5 GT/s) or PCIe3 (8 GT/s) rate.

1

2

Intel Xeon Processor E3-xxxx Series, Intel Core i3 Processor Series, Intel Pentium G2120, G2100T, and

G630.

Slot number Type

PCIe2

PCIe2

Length

Half

Half

Height

Half

Full

Connector link width Negotiable link width x8 x16 x4 x16

Intel Xeon Processor E3-xxxxV2 Series

Slot number

1

2

Type

PCIe2

PCIe3

Length

Half

Half

Height

Half

Full

Connector link width Negotiable link width x8 x16 x4 x16

System maintenance switch

Switch Default Function

1

Off

2

5

Off

Off

Off = No function

On = iLO security is disabled

Off = System configuration can be changed

On = System configuration is locked

Off = Power-on password is enabled

On = Power-on password is disabled

Component identification 11

Switch

6

Default

Off

Function

Off = No function

On = ROM reads configuration as invalid

Reserved

3, 4, 7, 8, 9,

10, 11, 12

When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings from both CMOS and NVRAM.

CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur.

NMI header

The NMI header enables administrators to perform a memory dump before performing a hard reset. Crash dump analysis is an essential part of eliminating potential reliability issues, such as hangs or crashes in operating systems, device drivers, and applications. Many crashes can freeze a system, requiring you to perform a hard reset. Resetting the system erases any information that supports root cause analysis.

Systems running Microsoft® Windows® experience a blue-screen trap when the OS crashes. When this happens, Microsoft® recommends that system administrators perform an NMI event by temporarily shorting the NMI header with a jumper. The NMI event enables a hung system to become responsive again.

For additional information, see the HP website

( http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf

).

System board LED definitions

Item Description

1

Initialization failure

Status

Yellow = System initialization failure

Off = Normal

Component identification 12

Item Description

2

3

4

5

Status

Power supply 1 failure Red = Power supply failure

Off = Normal

Power supply 2 failure Red = Power supply failure

Off = Normal

Auxiliary power Green = Standby power indicator

Off = Standby power invalid

Processor error Yellow = Critical processor error

Off = Normal

Drive numbering

Four-bay LFF drive model

Eight-bay SFF drive model

Drive LED definitions

Item LED

1

Locate

Status

Solid blue

Definition

The drive is being identified by a host application.

Component identification 13

4

2

Item LED

3

Activity ring

Status Definition

Flashing blue The drive carrier firmware is being updated or requires an update.

Rotating green Drive activity

Off No drive activity

Do not remove Solid white

Off

Do not remove the drive. Removing the drive causes one or more of the logical drives to fail.

Removing the drive does not cause a logical drive to fail.

Drive status Solid green The drive is a member of one or more logical drives.

Flashing green The drive is rebuilding or performing a RAID migration, stripe size migration, capacity expansion, or logical drive extension, or is erasing.

Flashing amber/green

The drive is a member of one or more logical drives and predicts the drive will fail.

Flashing amber The drive is not configured and predicts the drive will fail.

Solid amber The drive has failed.

Off The drive is not configured by a RAID controller.

FBWC module LED definitions

The FBWC module has three single-color LEDs (one amber and two green). The LEDs are duplicated on the reverse side of the cache module to facilitate status viewing.

Off

Off

Off

1 - Amber

Off

Off

2 - Green 3 - Green Interpretation

Off Off The cache module is not powered.

Flashing 0.5 Hz Flashing 0.5 Hz The cache microcontroller is executing from within its boot loader and receiving new flash code from the host controller.

Flashing 1 Hz Flashing 1 Hz The cache module is powering up, and the capacitor pack is charging.

Off Flashing 1 Hz The cache module is idle, and the capacitor pack is charging.

Off On The cache module is idle, and the capacitor pack is charged.

Component identification 14

1 - Amber

Off

2 - Green

On

3 - Green

On

Off

Off

Flashing 1 Hz

Flashing 1 Hz

Flashing 1 Hz Off

On Off

Flashing 1 Hz Off

Flashing 1 Hz On

Flashing 1 Hz

Flashing 2 Hz

Flashing 2 Hz

On Off

Flashing 2 Hz Off

Flashing 2 Hz On

On

On

On

On

Fan locations

Off

On

Interpretation

The cache module is idle, the capacitor pack is charged, and the cache contains data that has not yet been written to the drives.

A backup is in progress.

The current backup is complete with no errors.

The current backup failed, and data has been lost.

A power error occurred during the previous or current boot. Data may be corrupt.

An overtemperature condition exists.

The capacitor pack is not attached.

The capacitor has been charging for 10 minutes, but has not reached sufficient charge to perform a full backup.

The current backup is complete, but power fluctuations occurred during the backup.

The cache module microcontroller has failed.

Component identification 15

T-10/T-15 Torx screwdriver

The server includes a T-10/T-15 Torx screwdriver located beside the capacitor pack holder. Use the screwdriver to loosen screws during hardware configuration procedures.

Component identification 16

Operations

Power up the server

1.

2.

3.

Connect each power cord to the server.

Connect each power cord to the power source.

Press the Power On/Standby button.

The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.

Power down the server

Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and programs.

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.

IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the system.

To power down the server, use one of the following methods:

Press and release the Power On/Standby button.

This method initiates a controlled shutdown of applications and the OS before the server enters standby mode.

Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter standby mode.

This method forces the server to enter standby mode without properly exiting applications and the OS.

If an application stops responding, you can use this method to force a shutdown.

Use a virtual power button selection through iLO.

This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode.

Before proceeding, verify the server is in standby mode by observing that the system power LED is amber.

Extend the server from the rack

Operations 17

IMPORTANT: The requirement of extending or removing the server from the rack when performing installation and maintenance procedures depends on the rail system used:

If using a ball-bearing rail system, you can perform most installations and maintenance by simply extending the server from the rack.

If using a friction rail system, to perform installations or maintenance that requires access panel removal, remove the server from the rack.

To extend the server from an HP, Compaq-branded, Telco, or third-party rack:

1.

2.

Power down the server (on page 17 ).

Remove all power:

3. a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

Disconnect all peripheral cables.

WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized before extending a component from the rack.

WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release latches and sliding the server into the rack. The sliding rails could pinch your fingers.

4.

5.

6.

7.

8.

9.

Pull down the quick release levers on each side of the server.

Extend the server on the rack rails until the server rail-release latches engage.

If the server does not extend from the rack, use a T-25 Torx screwdriver to loosen the screws located within the lever housing.

After performing the installation or maintenance procedure, slide the server into the rack. For more information, see the documentation that ships with the rack-mounting option.

Connect the peripheral cables.

Connect each power cord to the server.

Connect each power cord to the power source.

Remove the server from the rack

WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment:

• Observe local occupational health and safety requirements and guidelines for manual material handling.

Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. HP recommends that a minimum of two people are required for all rack server installations. A third person may be required to help align the server if the server is installed higher than chest level.

Use caution when installing the server in or removing the server from the rack; it is unstable when not fastened to the rails.

Operations 18

IMPORTANT: The requirement of extending or removing the server from the rack when performing installation and maintenance procedures depends on the rail system used:

If using a ball-bearing rail system, you can perform most installations and maintenance by simply extending the server from the rack.

If using a friction rail system, to perform installations or maintenance that requires access panel removal, remove the server from the rack.

To remove the server from an HP, Compaq-branded, Telco, or third-party rack:

1.

2.

3.

Power down the server (on page 17 ).

Disconnect all peripheral cables and power cords from the server rear panel.

Extend the server from the rack (on page 17 ).

4.

5.

Remove the server from the rack. For more information, see the documentation that ships with the rack mounting option.

Place the server on a sturdy, level surface.

Remove the security bezel (optional)

To access the front panel components, unlock and then remove the security bezel.

Remove the access panel

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

CAUTION: Do not operate the server for long periods with the access panel open or removed.

Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.

1.

2.

Power down the server (on page 17 ).

Remove all power:

Operations 19

3.

4. a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

Do one of the following: o

Extend the server from the rack (on page 17 ).

o

Remove the server from the rack (on page 18 ).

Open the locking latch, slide the access panel to the rear of the chassis, and then remove the access panel.

If the latch is locked, use a T-15 Torx screwdriver to unlock the latch.

Install the access panel

1.

2.

3.

Place the access panel on top of the server with the locking latch open. Allow the panel to extend past the rear of the server by approximately 1.25 cm (0.5 inch).

Press the locking latch. The access panel slides to a closed position.

Use a T-15 Torx screwdriver to tighten the security screw on the locking latch.

Remove the air baffle

CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.

To remove the component:

1.

Power down the server (on page 17 ).

2.

3.

Remove all power: a.

Disconnect each power cord from the power source. b.

Disconnect each power cord from the server.

Do one of the following:

4. o o

Extend the server from the rack (on page 17 ).

Remove the server from the rack (on page 18 ).

Remove the access panel (on page 19 ).

Operations 20

5.

Remove the air baffle.

Install the air baffle

1.

Place the air baffle on top of the server.

2.

3.

4.

Install the access panel (on page 20 ).

Do one of the following: o o

Slide the server into the rack.

Install the server into the rack ("

Power up the server (on page 17 ).

Installing the server into the rack " on page 28 ).

Remove the PCI riser cage

To remove the component:

Operations 21

4.

5.

6.

7.

1.

2.

3.

Power down the server (on page 17 ).

Remove all power: a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

Do one of the following: o

Extend the server from the rack (on page 17 ).

o

Remove the server from the rack (on page 18 ).

Remove the access panel (on page 19 ).

Disconnect all cables connected to existing expansion boards.

Loosen the PCI riser cage thumbscrews.

Lift the PCI riser cage to unseat the PCI riser boards.

Install the PCI riser cage

CAUTION: To prevent damage to the server or expansion boards, power down the server, and disconnect all power cords before removing or installing the PCI riser cage.

1.

Align the PCI riser cage with the guide pin located on the chassis, and then press down the PCI riser cage.

Operations 22

2.

Tighten the PCI riser cage thumbscrews.

3.

4.

5.

Install the access panel (on page 20 ).

Do one of the following: o

Slide the server into the rack. o

Install the server into the rack (" Installing the server into the rack " on page 28 ).

Power up the server (on page 17 ).

Operations 23

Setup

Optional installation services

Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are available to meet your needs.

HP Care Pack Services offer upgraded service levels to expand your standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. Some of the Care Pack services are:

Hardware support o

6-Hour Call-to-Repair o

4-Hour 24x7 Same Day o

4-Hour Same Business Day

Software support o o

Microsoft® operating systems

Linux operating systems o

HP ProLiant Essentials (HP SIM and RDP)

Integrated hardware and software support o

Critical Service o o o

Proactive 24

Support Plus

Support Plus 24

Startup and implementation services for both hardware and software

For more information on HP Care Pack Services, see the HP website

( http://www.hp.com/services/carepack ).

Rack planning resources

The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more information on the content of each resource, see the rack resource kit documentation.

Optimum environment

When installing the server in a rack, select a location that meets the environmental standards described in this section.

Setup 24

Space and airflow requirements

To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where to install a rack:

Leave a minimum clearance of 63.5 cm (25 inches) in front of the rack.

Leave a minimum clearance of 76.2 cm (30 inches) behind the rack.

Leave a minimum clearance of 121.9 cm (48 inches) from the back of the rack to the back of another rack or row of racks.

HP servers draw in cool air through the front and expel warm air through the rear. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet.

CAUTION: To prevent improper cooling and damage to the equipment, do not block the ventilation openings.

When vertical space in the rack is not filled by a server or rack component, the gaps between the components might cause changes in airflow through the rack and across the servers. To maintain airflow cover all gaps with blanking panels.

CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

The 9000 and 10000 series racks provide proper server cooling from flow-through perforations in the front and rear doors that provide 64% open area for ventilation.

CAUTION: When using a Compaq branded 7000 series rack, install the high airflow rack door insert (PN 327281-B21 for 42U rack, PN 157847-B21 for 22U rack) to provide proper front-to-back airflow and cooling.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

Front and rear doors—If the 42U rack includes closing front and rear doors, you must allow

5,350 sq cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).

• Side—The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 in).

Temperature requirements

To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, climate-controlled environment.

The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C

(95°F). The temperature in the room where the rack is located must not exceed 35°C (95°F).

CAUTION: To reduce the risk of damage to the equipment when installing third-party options:

Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the maximum allowable limits.

• Do not exceed the manufacturer’s TMRA.

Setup 25

Power requirements

Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992

(code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option.

WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility.

CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply. This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.

When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines:

Balance the server power load between available AC supply branch circuits.

Do not allow the overall system AC current load to exceed 80 percent of the branch circuit AC current rating.

Do not use common power outlet strips for this equipment.

Provide a separate electrical circuit for the server.

Electrical grounding requirements

The server must be grounded properly for proper operation and safety. In the United States, you must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as any local and regional building codes. In Canada, you must install the equipment in accordance with

Canadian Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, you must install the equipment in accordance with any regional or national electrical wiring codes, such as the

International Electrotechnical Commission (IEC) Code 364, parts 1 through 7. Furthermore, you must be sure that all power distribution devices used in the installation, such as branch wiring and receptacles, are listed or certified grounding-type devices.

Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a PDU that is either permanently wired to the building’s branch circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips for the server is not recommended.

Server warnings and cautions

Setup 26

WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment:

Observe local occupational health and safety requirements and guidelines for manual material handling.

Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. HP recommends that a minimum of two people are required for all rack server installations. A third person may be required to help align the server if the server is installed higher than chest level.

Use caution when installing the server in or removing the server from the rack; it is unstable when not fastened to the rails.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.

CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply. This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.

CAUTION: Do not operate the server for long periods with the access panel open or removed.

Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.

Rack warnings

WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:

The leveling jacks are extended to the floor.

• The full weight of the rack rests on the leveling jacks.

• The stabilizing feet are attached to the rack if it is a single-rack installation.

The racks are coupled together in multiple-rack installations.

Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.

WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack:

At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and might become unstable when being moved on its casters.

Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides.

WARNING: To reduce the risk of personal injury or damage to the equipment, adequately stabilize the rack before extending a component outside the rack. Extend only one component at a time. A rack may become unstable if more than one component is extended.

Setup 27

WARNING: When installing a server in a telco rack, be sure that the rack frame is adequately secured at the top and bottom to the building structure.

Identifying the contents of the server shipping carton

Unpack the server shipping carton and locate the materials and documentation necessary for installing the server. All the rack mounting hardware necessary for installing the server into the rack is included with the rack or the server.

The contents of the server shipping carton include:

Server

Power cord

Printed setup documentation, Documentation CD, and software products

Rack mounting hardware kit and documentation (optional)

You need the following items for some procedures:

T-25 Torx screwdriver (to use on the screws located inside the server quick-release levers)

T-10/T-15 Torx screwdriver (on page 16 )

Flathead screwdriver (for dedicated iLO module installation)

Hardware options

Operating system or application software

Installing hardware options

Install any hardware options before initializing the server. For options installation information, see the option

documentation. For server-specific information, see "Hardware options installation (on page 32 )."

Installing the server into the rack

To install the server into a rack with square, round, or threaded holes, refer to the instructions that ship with the rack hardware kit.

If you are installing the server into a telco rack, order the appropriate option kit at the RackSolutions website

( http://www.racksolutions.com/hp ). Follow the server-specific instructions on the website to install the rack brackets.

Use the following information when connecting peripheral cables and power cords to the server.

Setup 28

WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment:

Observe local occupational health and safety requirements and guidelines for manual material handling.

Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. HP recommends that a minimum of two people are required for all rack server installations. A third person may be required to help align the server if the server is installed higher than chest level.

Use caution when installing the server in or removing the server from the rack; it is unstable when not fastened to the rails.

CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack.

Install the heaviest item first, and continue to populate the rack from the bottom to the top.

To install the server in an HP, Compaq-branded, Telco, or third party rack:

1.

Install the server and cable management arm option into the rack. See the documentation that ships with the Quick Deploy Rail System.

2.

Connect peripheral devices to the server. For information on identifying connectors, see "Rear panel

components (on page 8 )."

WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into RJ-45 connectors.

3.

4.

Connect the power cord to the rear of the server.

When using a hot-plug HP CS power supply, use the strain relief clip from the server hardware kit to secure the power cord.

5.

Connect the power cord to the power source.

Setup 29

WARNING: To reduce the risk of electric shock or damage to the equipment:

Do not disable the power cord grounding plug. The grounding plug is an important safety feature.

• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.

Unplug the power cord from the power supply to disconnect power to the equipment.

• Do not route the power cord where it can be walked on or pinched by items placed against it.

Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.

Installing the operating system

This ProLiant server does not ship with provisioning media. Everything needed to manage and install the system software and firmware is preloaded on the server.

To operate properly, the server must have a supported operating system. For the latest information on operating system support, see the HP website ( http://www.hp.com/go/supportos ).

To install an operating system on the server, use one of the following methods:

Intelligent Provisioning—The iLO Management Engine is a new feature on ProLiant servers that contains

Intelligent Provisioning for embedded deployment, updating, and provisioning capabilities. Intelligent

Provisioning can configure the server and install an operating system, eliminating the need for

SmartStart CDs and Smart Update Firmware DVDs.

To install an operating system on the server with Intelligent Provisioning (local or remote): a. b.

Connect the Ethernet cable, and then power on the server.

During server POST, press the F10 key. c. d. e.

Complete the initial Preferences and Registration portion of Intelligent Provisioning (on page 64 ).

At the 1 Start screen, click the Configure and Install button.

To finish the installation, follow the onscreen prompts. An Internet connection is required to update the firmware and systems software.

Remote deployment installation—To remotely deploy an operating system, use Insight Control server deployment for an automated solution.

For additional system software and firmware updates, download the HP Service Pack for ProLiant from the HP website ( http://www.hp.com/go/spp/download ). Software and firmware must be updated before using the server for the first time, unless any installed software or components require an older version. For more

information, see "Keeping the system current (on page 72 )."

The Smart Update Firmware DVD ISO is also available at the download tab on the HP website

( http://www.hp.com/go/foundation ).

For more information on using these installation methods, see the HP website ( http://www.hp.com/go/ilo ).

Powering on and selecting boot options

1.

2.

Connect the Ethernet cable and press the Power On/Standby button.

During the initial boot:

Setup 30

o o

To modify the server configuration ROM default settings, press F9 when prompted from the start up sequence to enter the RBSU. By default, RBSU runs in the English language.

If you do not need to modify the server configuration and are ready to install the system software, press F10 to access Intelligent Provisioning.

NOTE: If an HP Smart Array controller has been added or is embedded in the system, the controller defaults to a RAID configuration based on the size and number of hard drives installed.

For more information on modifying the controller default settings, see the documentation on the

Documentation CD.

For more information on automatic configuration, see the HP ROM-Based Setup Utility User Guide on the

Documentation CD or the iLO Management Engine Information Library

( http://www.hp.com/go/ilomgmtengine/docs ).

Registering the server

To register the server, refer to the HP Registration website ( http://register.hp.com

).

Setup 31

Hardware options installation

Introduction

If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.

Security bezel option

The security bezel helps prevent unauthorized physical access to the front panel components.

Install the security bezel and then lock it with the key provided with the kit.

Drive options

The server supports up to four non-hot-plug or hot-plug LFF drives and up to eight hot-plug SFF drives.

The embedded storage controller supports SATA drive installation only. For SAS drive installation, install the storage controller card and Mini-SAS cable option kits. The storage controller card option supports both

SATA and SAS drives.

Hardware options installation 32

Drive installation guidelines

When adding drives to the server, observe the following general guidelines:

The system automatically sets all device numbers.

Populate drive bays based on the drive numbering sequence. Start from the drive bay with the lowest

device number (" Drive numbering " on page 13 ).

When drives are grouped together into the same drive array, they must be of the same capacity to provide the greatest storage space efficiency.

Installing a non-hot-plug drive

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

To install the component:

1.

Power down the server (on page 17 ).

2.

Remove all power: a.

Disconnect each power cord from the power source.

3. b.

Disconnect each power cord from the server.

Remove the drive carrier.

4.

Remove the two metal brackets from the drive carrier.

Hardware options installation 33

5.

Install the drive in the carrier.

6.

Install the drive.

7.

8.

9.

10.

Connect each power cord to the server.

Connect each power cord to the power source.

Power up the server (on page 17 ).

Determine the status of the drive from the drive LED definitions (on page 13 ).

Installing a hot-plug drive

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

To install the component:

Hardware options installation 34

1.

Remove the drive blank.

2.

Prepare the drive.

3.

Install the drive.

4.

Determine the status of the drive from the drive LED definitions (on page 13 ).

Mini-SAS cable option

To connect the cable option:

1.

2.

Power down the server (on page 17 ).

Remove all power: a.

Disconnect each power cord from the power source.

3. b.

Disconnect each power cord from the server.

Do one of the following:

Hardware options installation 35

4.

5.

6. o o

Extend the server from the rack (on page 17 ).

Remove the server from the rack (on page

Remove the access panel (on page 19 ).

Remove the PCI riser cage (on page 21 ).

18 ).

Connect the Mini-SAS cable to the storage controller.

7.

8.

Install the storage controller (" Installing a storage controller " on page 38 ).

Route the Mini-SAS cable along the side of the system board towards the front chassis, and then connect the cable to the drive backplane: o

Full-height controller connection

Hardware options installation 36

o

Low-profile controller connection

9.

Secure the excess length of the Mini-SAS cable in the cable clip.

10.

11.

12.

13.

Connect the rest of the drive cables required in this drive configuration. For more information, see

"Storage cabling (on page 55 )."

Install the access panel (on page 20 ).

Do one of the following: o o

Slide the server into the rack.

Install the server into the rack (" Installing the server into the rack

Install the drives (" Drive options " on page 32 ).

" on page 28 ).

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

14.

15.

Connect each power cord to the server.

Connect each power cord to the power source.

Hardware options installation 37

16.

Power up the server (on page 17 ).

Controller options

The server ships with an embedded Smart Array B120i controller. For more information about the controller and its features, see the HP Dynamic Smart Array RAID Controller User Guide on the HP website

( http://www.hp.com/support/DSA_RAID_UG_en ).

To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).

Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs on the HP website ( http://www.hp.com/support ).

The server supports FBWC. FBWC consists of a cache module and a capacitor pack. The DDR cache module buffers and stores data being written by the controller. When the system is powered on, the capacitor pack fully charges in approximately 5 minutes. If a system power failure occurs, a fully charged capacitor pack provides power for up to 80 seconds. During that interval, the controller transfers the cached data from DDR memory to flash memory, where the data remains indefinitely or until a controller retrieves the data.

The data protection and the time limit also apply if a power outage occurs. When power is restored to the system, an initialization process writes the preserved data to the storage drives.

CAUTION: The cache module connector does not use the industry-standard DDR3 mini-DIMM pinout. Do not use the controller with cache modules designed for other controller models, because the controller can malfunction and you can lose data. Also, do not transfer this cache module to an unsupported controller model, because you can lose data.

CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the capacitor pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress.

CAUTION: After the server is powered down, wait for 30 seconds, and then check the amber LED before unplugging the cable from the cache module. If the amber LED flashes after 30 seconds, do not remove the cable from the cache module. The cache module is backing up data. Data will be lost if the cable is detached when the amber LED is still flashing.

IMPORTANT: The capacitor pack might have a low charge when installed. If the pack does have low charge a POST error message appears when the server is powered up, indicating that the capacitor pack is temporarily disabled. No action is necessary. The internal circuitry automatically recharges the capacitors and enables the capacitor pack. This process might take up to 4 hours. During this time, the cache module functions properly but without the performance advantage of the capacitor pack.

Installing a storage controller

HP recommends installing the storage controller option in a full-height expansion slot for better cable routing.

IMPORTANT: For additional installation and configuration information, refer to the documentation that ships with the option.

To install the component:

Hardware options installation 38

4.

5.

6.

1.

2.

3.

7.

8.

Power down the server (on page 17 ).

Remove all power: a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

Do one of the following: o

Extend the server from the rack (on page 17 ).

o

Remove the server from the rack (on page 18 ).

Remove the access panel (on page 19 ).

Install the storage controller (" Expansion board options " on page 48 ).

Connect all necessary internal and external cabling to the storage controller. For more information on these cabling requirements, see the document the ships with the option. For internal cable routing

information in different drive configuration, see "Storage cabling (on page 55 )."

Install the access panel (on page 20 ).

Do one of the following: o o

Slide the server into the rack.

Install the server into the rack (" Installing the server into the rack

Install the drives (" Drive options " on page 32 ).

" on page 28 ).

9.

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

10.

11.

12.

Connect each power cord to the server.

Connect each power cord to the power source.

Power up the server (on page 17 ).

For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant

Servers User Guide on the HP website ( http://www.hp.com/support/SAC_UG_ProLiantServers_en ). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).

Upgrade options exist for the integrated array controller. For a list of supported options, see the QuickSpecs on the HP website ( http://www.hp.com/support ).

Installing the FBWC module and capacitor pack

CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up.

To install the component:

1.

2.

Power down the server (on page 17 ).

Remove all power:

3. a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

Do one of the following: o

Extend the server from the rack (on page 17 ).

Hardware options installation 39

4.

5.

6. o

Remove the server from the rack (on page 18 ).

Remove the access panel (on page 19 ).

Remove the PCI riser cage (on page 21 ).

CAUTION: When connecting or disconnecting the capacitor pack cable, the connectors on the cache module and cable are susceptible to damage. Avoid excessive force and use caution to avoid damage to these connectors.

Connect the capacitor pack cable to the cache module.

7.

Install the cache module on the storage controller.

8.

9.

10.

Install the storage controller (" Installing a storage controller " on page 38 ).

Route the capacitor pack cable towards the front chassis. For more information on the capacitor pack

cabling in different drive configurations, see "Storage cabling (on page 55 )."

Install the capacitor pack: a.

Insert the cable end of the capacitor pack in the holder.

Hardware options installation 40

b.

Press the opposite end of the capacitor pack in the holder.

11.

12.

13.

14.

15.

Install the access panel (on page 20 ).

Do one of the following: o

Slide the server into the rack. o

Install the server into the rack (" Installing the server into the rack " on page 28 ).

Connect each power cord to the server.

Connect each power cord to the power source.

Power up the server (on page 17 ).

Optical drive option

To install the component:

1.

2.

Power down the server (on page 17 ).

Remove all power:

3. a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

Do one of the following: o

Extend the server from the rack (on page 17 ).

o

Remove the server from the rack (on page 18 ).

Hardware options installation 41

4.

Remove the optical drive blank.

5.

6.

Retain the blank for future use.

Remove the access panel (on page 19 ).

If you are installing the optical drive in an LFF drive model, do the following: a.

Thread the optical drive cable through the optical drive bay. b.

Connect the cable to the optical drive.

7.

Install the optical drive into the bay, and then secure it with the screw:

Hardware options installation 42

o

Four-bay LFF drive model o

Eight-bay SFF drive model

8.

9.

If you are installing the optical drive in an SFF drive model, connect the optical drive cable to the optical drive.

Connect the optical drive cable: a.

Route the optical drive cable through the cable clip on the front chassis. b. c.

Route the optical drive cable along the side of the system board, and then connect the cable to the system board.

Connect the four-pin (1x4) power supply cable to the power connector of the optical drive cable.

Hardware options installation 43

Four-bay LFF drive model

Eight-bay SFF drive model

10.

11.

12.

13.

14.

Install the access panel (on page 20 ).

Do one of the following: o

Slide the server into the rack. o

Install the server into the rack (" Installing the server into the rack " on page 28 ).

Connect each power cord to the server.

Connect each power cord to the power source.

Power up the server (on page 17 ).

Memory options

Hardware options installation 44

IMPORTANT: This server does not support mixing LRDIMMs, RDIMMs, or UDIMMs. Attempting to mix any combination of these DIMMs can cause the server to halt during BIOS initialization.

The server memory subsystem supports UDIMMs only. UDIMMs represent the most basic type of memory module and offer lower latency and (relatively) low power consumption, but are limited in capacity.

The server supports dual-rank, PC3-10600E/PC3-12800E (DDR3 ECC) DIMMs operating at 1333 or 1600

MHz speed.

Depending on the processor model and the number of DIMMs installed, the memory clock speed might be reduced to 1333 or 1066 MHz. For more information, see "General DIMM slot population guidelines (on

page 46 )."

HP SmartMemory

HP SmartMemory, introduced for Gen8 servers, authenticates and unlocks certain features available only on

HP Qualified memory and verifies whether installed memory has passed HP qualification and test processes.

Qualified memory is performance-tuned for HP ProLiant and BladeSystem servers and provides future enhanced support through HP Active Health and manageability software.

Certain performance features are unique with HP SmartMemory. The industry supports UDIMM at 2 DIMMs per channel at 1066 MT/s. HP SmartMemory supports 2 DIMMs per channel at 1333 MT/s, or 25% greater bandwidth.

DIMM identification

To determine DIMM characteristics, use the label attached to the DIMM and the following illustration and table.

1

2

Item Description

Size

Rank

Definition

1R = Single-rank

2R = Dual-rank

3R = Three-rank

4R = Quad-rank

Hardware options installation 45

Item Description

3

4

5

6

Data width

Voltage rating

Memory speed

DIMM type

Definition x4 = 4-bit x8 = 8-bit

L = Low voltage (1.35V)

U = Ultra low voltage (1.25V)

Blank or omitted = Standard

12800 = 1600-MT/s

10600 = 1333-MT/s

8500 = 1066-MT/s

R = RDIMM (registered)

E = UDIMM (unbuffered with ECC)

L = LRDIMM (load reduced)

For the latest supported memory information, see the QuickSpecs on the HP website

( http://h18000.www1.hp.com/products/quickspecs/ProductBulletin.html

). At the website, choose the geographic region, and then locate the product by name or product category.

Single-rank and dual-rank DIMMs

DIMM configuration requirements are based on these classifications:

Single-rank DIMM—One set of memory chips that is accessed while writing to or reading from the memory.

Dual-rank DIMM—Two single-rank DIMMs on the same module, with only one rank accessible at a time.

The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the DIMM.

Dual-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if current

DRAM technology supports 2-GB single-rank DIMMs, a dual-rank DIMM would be 4 GB.

Memory subsystem architecture

The memory subsystem in this server is divided into channels. The processor supports two channels, and each channel supports two DIMM slots.

Channel

1

Population order

C

A

Slot number

4

3

2

D

B

2

1

The server supports a maximum of 32 GB, using 2 GB, 4 GB, and 8 GB single-rank or dual-rank UDIMMs.

DIMM slots in this server are identified by number and by letter. Letters identify the population order. Slot numbers are reported by ROM messages during boot and for error reporting. For the DIMM slot locations,

see "DIMM slot locations (on page 11 )."

General DIMM slot population guidelines

The server has four memory slots.

The server supports two channels with two DIMM slots per channel.

Hardware options installation 46

o o

Memory channel 1 consists of the two DIMMs that are closest to the processor.

Memory channel 2 consists of the two DIMMs that are located farthest from the processor.

White DIMM slot indicate the first slot of a channel (3-A, 1-B).

Memory speed support depends on the type of processor installed. See the technical specification of the installed processor for more information.

The server supports up to 1600 MT/s ECC UDIMMs.

The server supports up to 32 GB (4x8 GB) UDIMMs.

The server does not support: o

RDIMMs o

Non-ECC UDIMMs o

Elpida DIMMs

When installing DIMMs: o o

Populate the DIMM slots in this sequence: 3-A, 1-B, 4-C, 2-D.

Use HP-qualified UDIMMs.

For detailed memory configuration rules and guidelines, use the Online DDR3 Memory Configuration Tool on the HP website ( http://www.hp.com/go/ddr3memory-configurator ).

Installing a DIMM

1.

Power down the server (on page 17 ).

2.

3.

4.

5.

6.

Remove all power: a.

Disconnect each power cord from the power source. b.

Disconnect each power cord from the server.

Do one of the following: o o

Extend the server from the rack (on page 17 ).

Remove the server from the rack (on page

Remove the access panel (on page 19 ).

18 ).

Remove the air baffle (on page 20 ).

Open the DIMM slot latches.

Hardware options installation 47

7.

Install the DIMM.

8.

9.

10.

11.

12.

13.

Install the air baffle (on page 21 ).

Install the access panel (on page 20 ).

Do one of the following: o

Slide the server into the rack. o

Install the server into the rack (" Installing the server into the rack " on page 28 ).

Connect each power cord to the server.

Connect each power cord to the power source.

Power up the server (on page 17 ).

Expansion board options

The server has both full-height and low-profile expansion slots for controller option installation (" PCIe riser board slot definitions " on page 11 ).

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all expansion slots have either an expansion slot cover or an expansion board installed.

To install the component:

1.

Power down the server (on page 17 ).

2.

Remove all power: a.

Disconnect each power cord from the power source.

3.

4.

5. b.

Disconnect each power cord from the server.

Do one of the following: o

Extend the server from the rack (on page 17 ).

o

Remove the server from the rack (on page 18 ).

Remove the access panel (on page 19 ).

Remove the PCI riser cage (on page 21 ).

Hardware options installation 48

6.

Identify the expansion slot compatible with the new option, and then remove the cover opposite that slot.

7.

Install the expansion board.

8.

Install the PCI riser cage (on page 22 ).

IMPORTANT: The server does not power up if the PCI riser cage is not seated properly.

9.

10.

11.

12.

13.

14.

Connect all necessary internal and external cables to the expansion board. For more information on these cabling requirements, see the documentation that ships with the option.

Install the access panel (on page 20 ).

Do one of the following: o

Slide the server into the rack. o

Install the server into the rack (" Installing the server into the rack " on page 28 ).

Connect each power cord to the server.

Connect each power cord to the power source.

Power up the server (on page 17 ).

Dedicated iLO management port option

To install the component:

1.

Power down the server (on page 17 ).

2.

Remove all power: a.

Disconnect each power cord from the power source.

3. b.

Disconnect each power cord from the server.

Do one of the following:

Hardware options installation 49

4.

5. o o

Extend the server from the rack (on page 17 ).

Remove the server from the rack (on page 18 ).

Remove the access panel (on page 19 ).

Using a flat screwdriver, toggle the knockout to loosen it, and then pull it out of the chassis.

6.

Install the dedicated iLO management module.

7.

8.

9.

10.

11.

Install the access panel (on page 20 ).

Do one of the following: o o

Slide the server into the rack.

Install the server into the rack (" Installing the server into the rack

Connect each power cord to the server.

" on page 28 ).

Connect each power cord to the power source.

Power up the server (on page 17 ).

Hardware options installation 50

Enabling the dedicated iLO management port

The onboard NIC 1/shared iLO connector is set as the default system iLO port.

To enable the installed dedicated iLO module:

1.

During the server startup sequence after module installation, to access iLO RBSU, press the F8 key.

2.

Select the Network menu.

3.

4.

5.

6.

7.

Click the Network Interface Adapter field.

To change the setting to ON, press the spacebar.

To save the new settings, press the F10 key.

Select the File menu, and then to close iLO RBSU, click Exit.

To confirm exiting iLO RBSU, click OK. The server automatically reboots.

IMPORTANT: If the iLO RBSU settings are reset to the default values, access to the machine will be lost. Access the physical machine, and then set the Network Interface Adapter field to ON.

HP Trusted Platform Module option

Use these instructions to install and enable a TPM on a supported server. This procedure includes three sections:

1.

Installing the Trusted Platform Module board.

2.

3.

Retaining the recovery key/password (on page 53 ).

Enabling the Trusted Platform Module (on page 53 ).

Enabling the TPM requires accessing RBSU (" HP ROM-Based Setup Utility " on page 67 ). For more

information about RBSU, see the HP website ( http://www.hp.com/go/ilomgmtengine/docs ).

TPM installation requires the use of drive encryption technology, such as the Microsoft Windows BitLocker

Drive Encryption feature. For more information on BitLocker, see the Microsoft website

( http://www.microsoft.com

).

CAUTION: Always observe the guidelines in this document. Failure to follow these guidelines can cause hardware damage or halt data access.

When installing or replacing a TPM, observe the following guidelines:

Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board.

When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology. For security reasons, only the customer can enable these features.

When returning a system board for service replacement, do not remove the TPM from the system board.

When requested, HP Service provides a TPM with the spare system board.

Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.

When using BitLocker, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity.

Hardware options installation 51

HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the encryption technology feature documentation provided by the operating system.

Installing the Trusted Platform Module board

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

To install the component:

1.

Power down the server (on page 17 ).

2.

Remove all power:

3.

4. a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

Do one of the following: o o

Extend the server from the rack (on page 17 ).

Remove the server from the rack (on page

Remove the access panel (on page 19 ).

18 ).

CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.

5.

Install the TPM board. Press down on the connector to seat the board (" System board components " on page 10 ).

Hardware options installation 52

6.

Install the TPM security rivet by pressing the rivet firmly into the system board.

7.

8.

9.

10.

11.

Install the access panel (on page 20 ).

Do one of the following: o

Slide the server into the rack. o

Install the server into the rack (" Installing the server into the rack " on page 28 ).

Connect each power cord to the server.

Connect each power cord to the power source.

Power up the server (on page 17 ).

Retaining the recovery key/password

The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after

BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.

To help ensure maximum security, observe the following guidelines when retaining the recovery key/password:

Always store the recovery key/password in multiple locations.

Always store copies of the recovery key/password away from the server.

Do not save the recovery key/password on the encrypted hard drive.

Enabling the Trusted Platform Module

1.

2.

3.

4.

5.

When prompted during the start-up sequence, access RBSU by pressing the F9 key.

From the Main Menu, select Server Security.

From the Server Security Menu, select Trusted Platform Module.

From the Trusted Platform Module Menu, select TPM Functionality.

Select Enable, and then press the Enter key to modify the TPM Functionality setting.

Hardware options installation 53

6.

7.

8.

Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.

Reboot the server.

Enable the TPM in the OS. For OS-specific instructions, see the OS documentation.

CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system board, replacing a hard drive, or modifying OS application TPM settings.

For more information on firmware updates and hardware procedures, see the HP Trusted Platform Module

Best Practices White Paper on the HP website ( http://www.hp.com/support ).

For more information on adjusting TPM usage in BitLocker™, see the Microsoft website

( http://technet.microsoft.com/en-us/library/cc732774.aspx

).

Hardware options installation 54

Cabling

Cabling overview

This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance.

For information on cabling peripheral components, refer to the white paper on high-density deployment at the HP website ( http://www.hp.com/products/servers/platforms ).

CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.

Storage cabling

The FBWC capacitor pack cabling is shown in the following images. The FBWC solution is a separately purchased option. Capacitor pack cabling is only supported in Smart Array controller options that support

FBWC installation.

Four-bay LFF non-hot-plug drive cage cabling

Mini-SAS cable connected to the system board

Item

1

2

Description

Power cable

700-mm Mini-SAS cable for non-hot-plug drive configuration

Cabling 55

Mini-SAS cable connected to a storage controller in the full-height expansion slot

Description

Power cable

Item

1

2

Capacitor pack cable

3

700-mm Mini-SAS cable for non-hot-plug drive configuration

Mini-SAS cable connected to a storage controller in the low-profile expansion slot

2

3

Item

1

Description

Power cable

Capacitor pack cable

700-mm Mini-SAS cable for non-hot-plug drive configuration

Cabling 56

Four-bay LFF hot-plug drive cage cabling

Mini-SAS cable connected to the system board

Description

Power cable

Item

1

2

560-mm Mini-SAS cable

Mini-SAS cable connected to a storage controller in the full-height expansion slot

2

3

Item

1

Description

Power cable

Capacitor pack cable

890-mm Mini-SAS cable

Cabling 57

Mini-SAS cable connected to a storage controller in the low-profile expansion slot

Description

Power cable

Capacitor pack cable

890-mm Mini-SAS cable

Item

1

2

3

Eight-bay SFF hot-plug drive cage cabling

Mini-SAS cables connected to a storage controller in the full-height expansion slot

Item

1

2

Description

560-mm Mini-SAS cable

700-mm Mini-SAS cable for hot-plug drive configuration

Cabling 58

Item

3

4

Description

Power cable

Capacitor pack cable

Optical drive cabling

LFF drive cage model

Item

1

Description

Optical drive power cable

2

Optical drive SATA cable

SFF drive cage model

Cabling 59

Item

1

2

Description

Optical drive power cable

Optical drive SATA cable

Power supply cabling

Nonredundant power supply cabling

Item

1

2

Description

24-pin power supply cable

4-pin power supply cable

Cabling 60

Redundant power supply cabling

Item

1

2

3

Description

24-pin power supply cable

26-pin RPS cable

4-pin power supply cable

CAUTION: The default and redundant power supplies in the server must have the same output power capacity. Verify that all power supplies have the same part number and label color. The system becomes unstable and might shut down when it detects mismatched power supplies.

Cabling 61

Software and configuration utilities

Server mode

The software and configuration utilities presented in this section operate in online mode, offline mode, or in both modes.

Software or configuration utility Server mode

HP iLO (on page 62 )

Online and Offline

Active Health System (on page 63 )

Integrated Management Log (on page 64 )

Intelligent Provisioning (on page 64 )

HP Insight Diagnostics (on page 65 )

HP Insight Remote Support software (on page 66 )

Erase Utility (on page 65 )

Scripting Toolkit (on page 66 )

HP Service Pack for ProLiant (on page 67 )

HP Smart Update Manager (on page 67 )

HP ROM-Based Setup Utility (on page 67 )

Array Configuration Utility (on page 69 )

Option ROM Configuration for Arrays (on page 70 )

ROMPaq utility (on page 71 )

Online and Offline

Online and Offline

Offline

Online and Offline

Online

Offline

Online

Online and Offline

Online and Offline

Offline

Online and Offline

Offline

Offline

Server QuickSpecs

For more information about product features, specifications, options, configurations, and compatibility, see the QuickSpecs on the HP website ( http://www.hp.com/go/productbulletin ). At the website, choose the geographic region, and then locate the product by name or product category.

HP iLO Management Engine

The HP iLO Management Engine is a set of embedded management features supporting the complete lifecycle of the server, from initial deployment through ongoing management.

HP iLO

The iLO subsystem is a standard component of selected HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server administration. The iLO subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO independent of the host server and its operating system.

Software and configuration utilities 62

iLO enables and manages the Active Health System (on page 63 ) and also features Agentless Management.

All key internal subsystems are monitored by iLO. SNMP alerts are sent directly by iLO regardless of the host operating system or even if no host operating system is installed.

HP Insight Remote Support software (on page 66 ) is also available in HP iLO with no operating system

software, drivers, or agents.

Using iLO, you can do the following:

Access a high-performance and secure Remote Console to the server from anywhere in the world.

Use the shared iLO Remote Console to collaborate with up to six server administrators.

Remotely mount high-performance Virtual Media devices to the server.

Securely and remotely control the power state of the managed server.

Have true Agentless Management with SNMP alerts from iLO regardless of the state of the host server.

Access Active Health System troubleshooting features through the iLO interface.

Subscribe to HP Insight Remote Support software without installing any drivers or agents.

For more information about iLO features (which may require an iLO Advanced Pack or iLO Advanced for

BladeSystem license), see the iLO documentation on the Documentation CD or on the HP website

( http://www.hp.com/go/ilo/docs ).

Active Health System

HP Active Health System provides the following features:

Combined diagnostics tools/scanners

Always on, continuous monitoring for increased stability and shorter downtimes

Rich configuration history

Health and service alerts

Easy export and upload to Service and Support

The HP Active Health System monitors and records changes in the server hardware and system configuration.

The Active Health System assists in diagnosing problems and delivering rapid resolution when server failures occur.

The Active Health System collects the following types of data:

Server model

Serial number

Processor model and speed

Storage capacity and speed

Memory capacity and speed

Firmware/BIOS

HP Active Health System does not collect information about Active Health System users' operations, finances, customers, employees, partners, or data center, such as IP addresses, host names, user names, and passwords. HP Active Health System does not parse or change operating system data from third-party error event log activities, such as content created or passed through by the operating system.

Software and configuration utilities 63

The data that is collected is managed according to the HP Data Privacy policy. For more information see the

HP website ( http://www.hp.com/go/privacy ).

The Active Health System log, in conjunction with the system monitoring provided by Agentless Management or SNMP Pass-thru, provides continuous monitoring of hardware and configuration changes, system status, and service alerts for various server components.

The Agentless Management Service is available in the SPP, which is a disk image (.iso) that you can download from the HP website ( http://www.hp.com/go/spp/download ). The Active Health System log can be downloaded manually from iLO or HP Intelligent Provisioning and sent to HP. For more information, see the HP iLO User Guide or HP Intelligent Provisioning User Guide on the HP website

( http://www.hp.com/go/ilo/docs ).

Integrated Management Log

The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.

You can view recorded events in the IML in several ways, including the following:

From within HP SIM

From within operating system-specific IML viewers o

For Windows: IML Viewer o

For Linux: IML Viewer Application

From within the iLO user interface

From within HP Insight Diagnostics (on page 65 )

Intelligent Provisioning

Several packaging changes have taken place with HP ProLiant Gen8 servers: SmartStart CDs and the Smart

Update Firmware DVD will no longer ship with these new servers. Instead, the deployment capability is embedded in the server as part of HP iLO Management Engine’s Intelligent Provisioning.

Intelligent Provisioning is an essential single-server deployment tool embedded in HP ProLiant Gen8 servers that simplifies HP ProLiant server setup, providing a reliable and consistent way to deploy HP ProLiant server configurations.

Intelligent Provisioning assists with the OS installation process by preparing the system for installing

"off-the-shelf" versions of leading operating system software and automatically integrating optimized

HP ProLiant server support software from SPP. SPP is the installation package for operating system-specific bundles of HP ProLiant optimized drivers, utilities, management agents, and system firmware.

Intelligent Provisioning provides maintenance-related tasks through Perform Maintenance features.

Intelligent Provisioning provides installation help for Microsoft Windows, Red Hat and SUSE Linux, and

VMware. For specific OS support, see the HP Intelligent Provisioning Release Notes.

For more information on Intelligent Provisioning software, see the HP website ( http://www.hp.com/go/ilo ).

For more information about Intelligent Provisioning drivers, firmware, and SPP, see the HP website

( http://www.hp.com/go/spp/download ).

Software and configuration utilities 64

HP Insight Diagnostics

HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation.

HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS

is not running. To run this utility, boot the server using Intelligent Provisioning (on page 64 ).

HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other related data needed for effective server management. Available in Microsoft Windows and Linux versions, the utility helps to ensure proper system operation.

For more information or to download the utility, see the HP website ( http://www.hp.com/servers/diags ). HP

Insight Diagnostics Online Edition is also available in the SPP. For more information, see the HP website

( http://www.hp.com/go/spp/download ).

HP Insight Diagnostics survey functionality

HP Insight Diagnostics (on page 65 ) provides survey functionality that gathers critical hardware and software

information on ProLiant servers.

This functionality supports operating systems that are supported by the server. For operating systems supported by the server, see the HP website ( http://www.hp.com/go/supportos ).

If a significant change occurs between data-gathering intervals, the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration.

Survey functionality is installed with every Intelligent Provisioning-assisted HP Insight Diagnostics installation,

or it can be installed through the SPP (" HP Service Pack for ProLiant " on page 67 ).

Erase Utility

CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives completely. Refer to the instructions for using this utility.

The Erase utility enables you to erase system CMOS, NVRAM, and hard drives. Run the Erase Utility if you must erase the system for the following reasons:

You want to install a new operating system on a server with an existing operating system.

You encounter an error when completing the steps of a factory-installed operating system installation.

To access the Erase Utility, click the Perform Maintenance icon from the Intelligent Provisioning home screen and then select Erase.

Run the Erase utility to:

Reset all settings — erases all drives, NVRAM, and RBSU

Reset all disks — erases all drives

Reset RBSU — erases current RBSU settings

After selecting the appropriate option, click Erase System. Click Exit to reboot the server after the erase task is completed. Click Cancel Erase to exit the utility without erasing.

Software and configuration utilities 65

HP Insight Remote Support software

HP strongly recommends that you install HP Insight Remote Support software to complete the installation or upgrade of your product and to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or

HP contractual support agreement. HP Insight Remote Support supplements your monitoring 24 x 7 to ensure maximum system availability by providing intelligent event diagnosis, and automatic, secure submission of hardware event notifications to HP, which will initiate a fast and accurate resolution, based on your product’s service level. Notifications may be sent to your authorized HP Channel Partner for on-site service, if configured and available in your country. The software is available in two variants:

HP Insight Remote Support Standard: This software supports server and storage devices and is optimized for environments with 1–50 servers. Ideal for customers who can benefit from proactive notification but do not need proactive service delivery and integration with a management platform.

HP Insight Remote Support Advanced: For customers with mid-size to large environments with over 500 devices who require HP Proactive Services, or customers currently using HP Operations Manager or

SAP Solution Manager to manage their environment, HP recommends installing the latest HP Insight

Remote Support Advanced software. This software provides comprehensive remote monitoring and proactive service support for nearly all HP servers, storage, network, and SAN environments, plus selected non-HP servers that have a support obligation with HP. It is integrated with HP Systems Insight

Manager. A dedicated server is recommended to host both HP Systems Insight Manager and HP Insight

Remote Support Advanced.

Details for both versions are available on the HP website ( http://www.hp.com/go/insightremotesupport ).

To download the software, go to Software Depot ( http://www.software.hp.com

).

Select Insight Remote Support from the menu on the right.

The HP Insight Remote Support software release notes detail the specific prerequisites, supported hardware, and associated operating systems. For more information:

See the HP Insight Remote Support Standard Release Notes on the HP website

( http://www.hp.com/go/insightremotestandard-docs ).

See the HP Insight Remote Support Advanced Release Notes on the HP website

( http://www.hp.com/go/insightremoteadvanced-docs ).

Scripting Toolkit

The Scripting Toolkit is a server deployment product that enables you to build an unattended automated installation for high-volume server deployments. The Scripting Toolkit is designed to support ProLiant BL, ML,

DL, and SL servers. The toolkit includes a modular set of utilities and important documentation that describes how to apply these tools to build an automated server deployment process.

The Scripting Toolkit provides a flexible way to create standard server configuration scripts. These scripts are used to automate many of the manual steps in the server configuration process. This automated server configuration process cuts time from each deployment, making it possible to scale rapid, high-volume server deployments.

For more information, and to download the Scripting Toolkit, see the HP website

( http://www.hp.com/go/ProLiantSTK ).

Software and configuration utilities 66

HP Service Pack for ProLiant

SPP is a release set that contains a comprehensive collection of firmware and system software components, all tested together as a single solution stack for HP ProLiant servers, their options, BladeSystem enclosures, and limited HP external storage.

SPP has several key features for updating HP ProLiant servers. Using HP SUM as the deployment tool, SPP can be used in an online mode on a Windows or Linux hosted operating system, or in an offline mode where the server is booted to the ISO so that the server can be updated automatically with no user interaction or updated in interactive mode.

For more information or to download SPP, see the HP website ( http://www.hp.com/go/spp ).

HP Smart Update Manager

The HP SUM provides intelligent and flexible firmware and software deployment. This technology assists in reducing the complexity of provisioning and updating HP ProLiant Servers, options, and Blades within the data center. HP SUM is used to deploy firmware and software in SPP.

HP SUM enables system administrators to upgrade ROM images efficiently across a wide range of servers and options. This tool has the following features:

Enables GUI and a command-line, scriptable interface

Provides scriptable, command-line deployment

Requires no agent for remote installations

Enables dependency checking, which ensures appropriate install order and dependency checking between components

Deploys software and firmware on Windows and Linux operating systems

Performs local or remote (one-to-many) online deployment

Deploys firmware and software together

Supports offline and online deployment

Deploys necessary component updates only

Downloads the latest components from Web

Enables direct update of BMC firmware (HP iLO)

For more information about HP SUM and to access the HP Smart Update Manager User Guide, see the HP website ( http://www.hp.com/go/hpsum/documentation ).

HP ROM-Based Setup Utility

RBSU is a configuration utility embedded in ProLiant servers that performs a wide range of configuration activities that can include the following:

Configuring system devices and installed options

Enabling and disabling system features

Displaying system information

Selecting the primary boot controller

Software and configuration utilities 67

Configuring memory options

Language selection

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/rbsu ).

Using RBSU

To use RBSU, use the following keys:

To access RBSU, press the F9 key during power-up when prompted.

To navigate the menu system, use the arrow keys.

To make selections, press the Enter key.

To access Help for a highlighted configuration option, press the F1 key.

IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does not prompt you for confirmation of settings before you exit the utility. To change a selected setting, you must select a different setting and press the Enter key.

Default configuration settings are applied to the server at one of the following times:

Upon the first system power-up

After defaults have been restored

Default configuration settings are sufficient for proper typical server operation, but configuration settings can be modified using RBSU. The system will prompt you for access to RBSU with each power-up.

Auto-configuration process

The auto-configuration process automatically runs when you boot the server for the first time. During the power-up sequence, the system ROM automatically configures the entire system without needing any intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a default setting based on the number of drives connected to the server.

NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the array. You must run ORCA to configure the array settings.

NOTE: The server may not support all the following examples.

Drives installed

1

2

3, 4, 5, or 6

More than 6

Drives used

1

2

3, 4, 5, or 6

0

RAID level

RAID 0

RAID 1

RAID 5

None

To change any ORCA default settings and override the auto-configuration process, press the F8 key when prompted.

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/rbsu ).

Software and configuration utilities 68

Boot options

Near the end of the boot process, the boot options screen is displayed. This screen is visible for several seconds before the system attempts to boot from a supported boot device. During this time, you can do the following:

Access RBSU by pressing the F9 key.

Access Intelligent Provisioning Maintenance Menu by pressing the F10 key.

Access the boot menu by pressing the F11 key.

Force a PXE Network boot by pressing the F12 key.

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.

1.

During the server startup sequence, press the F9 key to access RBSU.

2.

3.

Select the Advanced Options menu.

Select Service Options.

4.

5.

6.

7.

8.

9.

10.

11.

Select Serial Number. The following warning appears:

Warning: The serial number should ONLY be modified by qualified service personnel. This value should always match the serial number located on the chassis.

Press the Enter key to clear the warning.

Enter the serial number and press the Enter key.

Select Product ID. The following warning appears:

Warning: The Product ID should ONLY be modified by qualified service personnel. This value should always match the Product ID located on the chassis.

Enter the product ID and press the Enter key.

Press the Esc key to close the menu.

Press the Esc key to exit RBSU.

Press the F10 key to confirm exiting RBSU. The server automatically reboots.

Utilities and features

Array Configuration Utility

ACU is a utility with the following features:

Runs as a local application or remote service accessed through the HP System Management Homepage

Supports online array capacity expansion, logical drive extension, assignment of online spares, and

RAID or stripe size migration

Suggests the optimum configuration for an unconfigured system

For supported controllers, provides access to licensed features, including: o

Moving and deleting individual logical volumes

Software and configuration utilities 69

o o o o o

Advanced Capacity Expansion (SATA to SAS and SAS to SATA)

Offline Split Mirror

RAID 6 and RAID 60

RAID 1 (ADM) and RAID 10 (ADM)

HP Drive Erase

Video-On-Demand Advanced Controller Settings o

Provides different operating modes, enabling faster configuration or greater control over the configuration options

Remains available any time that the server is on

Displays on-screen tips for individual steps of a configuration procedure

Provides context-sensitive searchable help content

Provides diagnostic and SmartSSD Wear Gauge functionality on the Diagnostics tab

ACU is now available as an embedded utility, starting with HP ProLiant Gen8 servers. To access ACU, use one of the following methods:

If an optional controller is not installed, press F10 during boot.

If an optional controller is installed, when the system recognizes the controller during POST, press F5.

For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers running Microsoft® operating systems require one of the following supported browsers:

Internet Explorer 6.0 or later

Mozilla Firefox 2.0 or later

For Linux servers, see the README.TXT file for additional browser and support information.

For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant

Servers User Guide on the HP website ( http://www.hp.com/support/SAC_UG_ProLiantServers_en ). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign

RAID levels, and establish online spare configurations.

The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Deleting a logical drive configuration

Setting the controller to be the boot controller

Selecting the boot volume

If you do not use the utility, ORCA will default to the standard configuration.

For more information regarding the default configurations that ORCA uses, see the HP ROM-Based Setup

Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/rbsu ).

Software and configuration utilities 70

For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant

Servers User Guide on the HP website ( http://www.hp.com/support/SAC_UG_ProLiantServers_en ). To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website ( http://www.hp.com/support/CASAC_RG_en ).

ROMPaq utility

The ROMPaq utility enables you to upgrade the system firmware (BIOS). To upgrade the firmware, insert a

ROMPaq USB Key into an available USB port and boot the system. In addition to ROMPaq, Online Flash

Components for Windows and Linux operating systems are available for updating the system firmware.

The ROMPaq utility checks the system and provides a choice (if more than one exists) of available firmware revisions.

For more information, go to the HP website ( http://www.hp.com/go/hpsc ) and click on Drivers, Software

& Firmware. Then, enter your product name in the Find an HP product field and click Go.

Automatic Server Recovery

ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND (does not apply to HP ProLiant DL980 Servers), or panic. A system fail-safe timer, the

ASR timer, starts when the System Management driver, also known as the Health Driver, is loaded. When the operating system is functioning properly, the system periodically resets the timer. However, when the operating system fails, the timer expires and restarts the server.

ASR increases server availability by restarting the server within a specified time after a system hang. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the System Management Homepage or through RBSU.

USB support

HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provided by the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB devices through legacy USB support, which is enabled by default in the system ROM.

Legacy USB support provides USB functionality in environments where USB support is not available normally.

Specifically, HP provides legacy USB functionality for the following:

POST

RBSU

Diagnostics

DOS

Operating environments which do not provide native USB support

Redundant ROM support

The server enables you to upgrade or configure the ROM safely with redundant ROM support. The server has a single ROM that acts as two separate ROM images. In the standard implementation, one side of the ROM contains the current ROM program version, while the other side of the ROM contains a backup version.

Software and configuration utilities 71

NOTE: The server ships with the same version programmed on each side of the ROM.

Safety and security benefits

When you flash the system ROM, ROMPaq writes over the backup ROM and saves the current ROM as a backup, enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason. This feature protects the existing ROM version, even if you experience a power failure while flashing the ROM.

Keeping the system current

Drivers

IMPORTANT: Always perform a backup before installing or updating device drivers.

The server includes new hardware that may not have driver support on all OS installation media.

If you are installing an Intelligent Provisioning-supported OS, use Intelligent Provisioning (on page 64 ) and its

Configure and Install feature to install the OS and latest supported drivers.

If you do not use Intelligent Provisioning to install an OS, drivers for some of the new hardware are required.

These drivers, as well as other option drivers, ROM images, and value-add software can be downloaded as part of an SPP.

If you are installing drivers from SPP, be sure that you are using the latest SPP version that your server supports. To verify that your server is using the latest supported version and for more information about SPP, see the HP website ( http://www.hp.com/go/spp/download ).

To locate the drivers for a particular server, go to the HP website ( http://www.hp.com/go/hpsc ) and click on Drivers, Software & Firmware. Then, enter your product name in the Find an HP product field and click

Go.

Software and firmware

Software and firmware should be updated before using the server for the first time, unless any installed software or components require an older version. For system software and firmware updates, download the

SPP (" HP Service Pack for ProLiant " on page 67 ) from the HP website (

http://www.hp.com/go/spp ).

Version control

The VCRM and VCA are web-enabled Insight Management Agents tools that HP SIM uses to schedule software update tasks to the entire enterprise.

VCRM manages the repository for SPP. Administrators can view the SPP contents or configure VCRM to automatically update the repository with internet downloads of the latest software and firmware from

HP.

VCA compares installed software versions on the node with updates available in the VCRM managed repository. Administrators configure VCA to point to a repository managed by VCRM.

Software and configuration utilities 72

For more information about version control tools, see the HP Systems Insight Manager User Guide, the HP

Version Control Agent User Guide, and the HP Version Control Repository User Guide on the HP website

( http://www.hp.com/go/hpsim ).

HP Operating Systems and Virtualization Software Support for

ProLiant Servers

For information about specific versions of a supported operating system, see the HP website

( http://www.hp.com/go/ossupport ).

Change control and proactive notification

HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products.

For more information, refer to the HP website ( http://www.hp.com/go/pcn ).

Software and configuration utilities 73

Troubleshooting

Troubleshooting resources

The HP ProLiant Gen8 Troubleshooting Guide, Volume I: Troubleshooting provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, issue resolution, and software maintenance on ProLiant servers and server blades. To view the guide, select a language:

English ( http://www.hp.com/support/ProLiant_TSG_v1_en )

French ( http://www.hp.com/support/ProLiant_TSG_v1_fr )

Spanish ( http://www.hp.com/support/ProLiant_TSG_v1_sp )

German ( http://www.hp.com/support/ProLiant_TSG_v1_gr )

Japanese ( http://www.hp.com/support/ProLiant_TSG_v1_jp )

Simplified Chinese ( http://www.hp.com/support/ProLiant_TSG_v1_sc )

The HP ProLiant Gen8 Troubleshooting Guide, Volume II: Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the guide, select a language:

English ( http://www.hp.com/support/ProLiant_EMG_v1_en )

French ( http://www.hp.com/support/ProLiant_EMG_v1_fr )

Spanish ( http://www.hp.com/support/ProLiant_EMG_v1_sp )

German ( http://www.hp.com/support/ProLiant_EMG_v1_gr )

Japanese ( http://www.hp.com/support/ProLiant_EMG_v1_jp )

Simplified Chinese ( http://www.hp.com/support/ProLiant_EMG_v1_sc )

Troubleshooting 74

System battery replacement

If the server no longer automatically displays the correct date and time, you might have to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

• Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

2.

Power down the server (on page 17 ).

Remove all power: a. b.

Disconnect each power cord from the power source.

Disconnect each power cord from the server.

3.

4.

5.

6.

7.

Do one of the following: o

Extend the server from the rack (on page 17 ).

o

Remove the server from the rack (on page 18 ).

Remove the access panel (on page 19 ).

Remove the air baffle (on page 20 ).

Locate the battery on the system board (" System board components " on page 10 ).

Remove the battery.

System battery replacement 75

IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through RBSU.

To replace the component, reverse the removal procedure.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

System battery replacement 76

Regulatory compliance notices

Regulatory compliance identification numbers

For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.

Federal Communications Commission notice

Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio

Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and

B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user.

FCC rating label

The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement.

FCC Notice, Class A Equipment

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.

FCC Notice, Class B Equipment

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to

Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to

Regulatory compliance notices 77

radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.

Consult the dealer or an experienced radio or television technician for help.

Declaration of conformity for products marked with the FCC logo, United States only

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

For questions regarding this product, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 530113

Houston, Texas 77269-2000

1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.)

For questions regarding this FCC declaration, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 510101

Houston, Texas 77269-2000

1­281-514-3333

To identify this product, refer to the part, series, or model number found on the product.

Modifications

The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.

Cables

Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.

Canadian notice (Avis Canadien)

Class A equipment

Regulatory compliance notices 78

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Class B equipment

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

European Union regulatory notice

Products bearing the CE marking comply with the following EU Directives:

Low Voltage Directive 2006/95/EC

EMC Directive 2004/108/EC

Ecodesign Directive 2009/125/EC, where applicable

CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP.

Compliance with these directives implies conformity to applicable harmonized European standards

(European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website

( http://www.hp.eu/certificates ) (type the product number in the search field).

The compliance is indicated by one of the following conformity markings placed on the product:

For non-telecommunications products and for EU harmonized telecommunications products, such as

Bluetooth® within power class below 10mW.

For EU non-harmonized telecommunications products (If applicable, a 4-digit notified body number is inserted between CE and !).

Please refer to the regulatory label provided on the product.

The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger

Strasse 140, 71034 Boeblingen, GERMANY.

Disposal of waste equipment by users in private households in the European Union

Regulatory compliance notices 79

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

Japanese notice

BSMI notice

Korean notice

Class A equipment

Regulatory compliance notices 80

Class B equipment

Chinese notice

Class A equipment

Vietnam compliance marking notice

This marking is for applicable products only.

Ukraine notice

Laser compliance

This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation.

Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser

Notice No. 50, dated June 24, 2007; and with IEC 60825-1:2007.

Regulatory compliance notices 81

WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:

• Do not try to open the module enclosure. There are no user-serviceable components inside.

Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.

• Allow only HP Authorized Service technicians to repair the unit.

The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.

Battery replacement notice

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

• Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Taiwan battery recycling notice

The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the

Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion.

Contact a qualified Taiwanese recycler for proper battery disposal.

Power cord statement for Japan

Regulatory compliance notices 82

Acoustics statement for Germany (Geräuschemission)

Schalldruckpegel L pA

< 70 dB(A)

Zuschauerpositionen (bystander positions), Normaler Betrieb (normal operation)

Nach ISO 7779:1999 (Typprüfung)

Regulatory compliance notices 83

Electrostatic discharge

Preventing electrostatic discharge

To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.

To prevent electrostatic damage:

Avoid hand contact by transporting and storing products in static-safe containers.

Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.

Place parts on a grounded surface before removing them from their containers.

Avoid touching pins, leads, or circuitry.

Always be properly grounded when touching a static-sensitive component or assembly.

Grounding methods to prevent electrostatic discharge

Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:

Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.

Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.

Use conductive field service tools.

Use a portable field service kit with a folding static-dissipating work mat.

If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.

For more information on static electricity or assistance with product installation, contact an authorized reseller.

Electrostatic discharge 84

Specifications

Environmental specifications

Specification Value

Temperature range*

Operating

10°C to 35°C (50°F to 95°F)

Nonoperating

-30°C to 60°C (-22°F to 140°F)

Relative humidity

(noncondensing)

Operating, maximum wet bulb temperature of 28°C (82.4°F)

10% to 90%

Nonoperating, maximum wet bulb temperature of 38.7°C

(101.7°F)

5% to 95%

* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.

Server specifications

Specification Value

Height

4.32 cm (1.70 in)

Depth for models with LFF drive cage 75.00 cm (29.50 in)

Depth for models with SFF drive cage 69.90 cm (27.50 in)

Width

43.46 cm (17.11 in)

Weight (approximate range)

10.00 kg to 24.00 kg (22.00 lb to 53.00 lb)

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:

HP 350 W 1U Factory Integrated Power Supply

HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)

HP 460 W CS Platinum Plus Hot-plug Power Supply (94% efficiency)

HP 350 W 1U Factory Integrated Power Supply

Specification

Input requirements

Value

Rated input voltage

Rated input frequency

100 V AC–240 V AC

50 Hz–60 Hz

Specifications 85

Rated input current

Rated input power

Power supply output

Efficiency

Maximum peak power

6 A

430 W at 115 V

430 W at 230 V

Not less than 82% at 100% load

Not less than 85% at 50% load

Not less than 82% at 20% load

400 W at 100 V to 120 V AC input

400 W at 200 V to 240 V AC input

HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)

Specification

Input requirements

Rated input voltage

Rated input frequency

Rated input current

Rated input power

Power supply output

Efficiency

Value

100 V AC–240 V AC

50 Hz–60 Hz

6 A–3 A

526 W at 100 V AC

505 W at 200 V AC

Not less than 87.5% at 100% load

Not less than 89.5% at 50% load

Not less than 87.5% at 20% load

Rated steady-state output power 460 W at 100 V to 120 V AC output

460 W at 200 V to 240 V AC output

Maximum peak power

460 W at 100 V to 120 V AC output

460 W at 200 V to 240 V AC output

HP 460 W CS Platinum Plus Hot-plug Power Supply (94% efficiency)

Specification

Input requirements

Rated input voltage

Rated input frequency

Rated input current

Rated input power

Power supply output

Efficiency

Value

100 V AC–240 V AC

50 Hz–60 Hz

6 A–3 A

509 W at 100 V AC

495 W at 230 V AC

Not less than 89% at 100% load

Not less than 92% at 50% load

Not less than 90% at 20% load

Specifications 86

Rated steady-state output power 460 W at 100 V to 120 V AC output

460 W at 200 V to 240 V AC output

Maximum peak power

460 W at 100 V to 120 V AC output

460 W at 200 V to 240 V AC output

Hot-plug power supply calculations

For hot-plug power supply specifications and calculators to determine electrical and heat loading for the server, refer to the HP Enterprise Configurator website ( http://h30099.www3.hp.com/configurator/ ).

Specifications 87

Support and other resources

Before you contact HP

Be sure to have the following information available before you call HP:

Active Health System log

Download and have available an Active Health System log for 3 days before the failure was detected.

For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website ( http://www.hp.com/go/ilo/docs ).

Onboard Administrator SHOW ALL report (for HP BladeSystem products only)

For more information on obtaining the Onboard Administrator SHOW ALL report, see the HP website

( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c

02843807 ).

Technical support registration number (if applicable)

Product serial number

Product model name and number

Product identification number

Applicable error messages

Add-on boards or hardware

Third-party hardware or software

Operating system type and revision level

HP contact information

For United States and worldwide contact information, see the Contact HP website

( http://www.hp.com/go/assistance ).

In the United States:

To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may be recorded or monitored.

If you have purchased a Care Pack (service upgrade), see the Support & Drivers website

( http://www8.hp.com/us/en/support-drivers.html

). If the problem cannot be resolved at the website, call 1-800-633-3600. For more information about Care Packs, see the HP website

( http://pro-aq-sama.houston.hp.com/services/cache/10950-0-0-225-121.html

).

Customer Self Repair

HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service

Support and other resources 88

providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:

Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.

Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.

NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty,

HP requires that an authorized service provider replace the part. These parts are identified as "No" in the

Illustrated Parts Catalog.

Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits.

If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days. The defective part must be returned with the associated documentation in the provided shipping material. Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.

For more information about HP's Customer Self Repair program, contact your local service provider. For the

North American program, refer to the HP website ( http://www.hp.com/go/selfrepair ).

Réparation par le client (CSR)

Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces CSR:

Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.

Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.

REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.

Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance téléphonique, appelez le

Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d'expédition et de retour, et détermine la société de courses ou le transporteur à utiliser.

Support and other resources 89

Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP

( http://www.hp.com/go/selfrepair ).

Riparazione da parte del cliente

Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza

HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:

Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.

Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.

NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.

In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP.

Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.

Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il programma in Nord America fare riferimento al sito Web HP ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere

Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der

Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses

Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:

Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den

Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen

Service berechnet.

Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer

Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche

Kosten anfallen.

Support and other resources 90

HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des

Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.

CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert.

Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen

Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen

Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen

Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer

Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den

Kurier-/Frachtdienst.

Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter

( http://www.hp.com/go/selfrepair ).

Reparaciones del propio cliente

Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self

Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente

CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:

Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a

HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.

Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.

NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra "No" en el catálogo ilustrado de componentes.

Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas

Support and other resources 91

sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.

Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite la página web de HP siguiente ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee categorieën CSR-onderdelen:

Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.

Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.

OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen.

Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".

Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service

Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.

Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website ( http://www.hp.com/go/selfrepair ).

Reparo feito pelo cliente

Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente.

Existem duas categorias de peças CSR:

Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.

Support and other resources 92

Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.

OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado.

Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis.

A peça com defeito deve ser enviada com a documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a

HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.

Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP

( http://www.hp.com/go/selfrepair ).

Support and other resources 93

Support and other resources 94

Support and other resources 95

Acronyms and abbreviations

ABEND abnormal end

ACU

Array Configuration Utility

AMP

Advanced Memory Protection

ASR

Automatic Server Recovery

BMC baseboard management controller

BSMI

Bureau of Standards, Metrology and Inspection

CE

Conformité Européenne (European Conformity)

CSA

Canadian Standards Association

CSR

Customer Self Repair

DDR double data rate

EMI electromagnetic interference

FBWC flash-backed write cache

Acronyms and abbreviations 96

FCC

Federal Communications Commission

HP CS

HP Common Slot (power supply)

HP SIM

HP Systems Insight Manager

HP SUM

HP Smart Update Manager

IEC

International Electrotechnical Commission iLO

Integrated Lights-Out

IML

Integrated Management Log

ISO

International Organization for Standardization

LFF large form factor

LRDIMM load reduced dual in-line memory module

NMI nonmaskable interrupt

NVRAM nonvolatile memory

ORCA

Option ROM Configuration for Arrays

PCIe peripheral component interconnect express

Acronyms and abbreviations 97

PDU power distribution unit

POST

Power-On Self Test

PXE preboot execution environment

RBSU

ROM-Based Setup Utility

RDIMM registered dual in-line memory module

RDP

Rapid Deployment Pack

RF radio frequency

RFI radio frequency interference

RPS redundant power supply

SAS serial attached SCSI

SATA serial ATA

SD

Secure Digital

SFF small form factor

SPP

HP Service Pack for ProLiant

Acronyms and abbreviations 98

TMRA recommended ambient operating temperature

TPM

Trusted Platform Module

UDIMM unregistered dual in-line memory module

UID unit identification

USB universal serial bus

VCA

Version Control Agent

VCRM

Version Control Repository Manager

Acronyms and abbreviations 99

Documentation feedback

HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback ( mailto:[email protected]

).

Include the document title and part number, version number, or the URL when submitting your feedback.

Documentation feedback 100

Index

A

access panel 19, 20

Active Health System 62, 63

ACU (Array Configuration Utility) 62, 69

air baffle 20, 21

airflow requirements 24, 25

Array Configuration Utility (ACU) 69

ASR (Automatic Server Recovery) 71

authorized reseller 88

auto-configuration process 68

Automatic Server Recovery (ASR) 71

B

Basic Input/Output System (BIOS) 62, 71

battery 75, 82

BIOS (Basic Input/Output System) 62, 71

BIOS upgrade 62, 71

boot options 30, 69

BSMI notice 80

buttons 7

C

cable shielding 78 cables 55, 78

cabling 55

cabling, drive 55, 57, 58

cabling, DVD-ROM drive 59

cabling, FBWC 55, 57, 58 cabling, hot-plug SAS drive 57, 58

cabling, non-hot-plug drive 55

cabling, non-redundant power supply 60

cabling, optical drive 59

cabling, redundant power supply 61

Canadian notice 78

capacitor pack 39

Care Pack 24

Change Control 73

Chinese notice 81

components, identification 7

configuration of system 30, 62

connectors 7

contacting HP 88

controller 38 controller options 38

CSR (customer self repair) 88 customer self repair (CSR) 88

D

dedicated iLO management connector 49, 51

diagnostic tools 62, 65, 71

diagnostics utility 65

DIMM identification 45

DIMM population guidelines 46

DIMMs 46, 47

DIMMs, installation 47

DIMMs, single- and dual-rank 46

drive LEDs 13 drive numbering 13

drivers 72

drives 13, 32

drives, determining status of 13

E

electrical grounding requirements 26

electrostatic discharge 84

enabling the Trusted Platform Module 53

environmental requirements 24, 26

environmental specifications 85

Erase Utility 62, 65

error messages 74

European Union notice 79

expansion board options 48 expansion boards 48 expansion slot covers, removing 48

extending server from rack 17

F

fan module locations 15

FBWC capacitor pack 39

FBWC module 39

FBWC module LEDs 14

FCC rating label 77

Federal Communications Commission (FCC)

notice 77, 78

firmware 72

Index 101

front panel buttons 8

front panel components 7

front panel LEDs 8

G

grounding methods 84

grounding requirements 26

H

hard drives, determining status of 13

hard drives, installing 32, 33

hardware options 28, 32 hardware options installation 32

health driver 71

help resources 88

HP Insight Diagnostics 65

HP Insight Remote Support software 66

HP Service Pack for ProLiant 62, 67

HP Smart Update Manager overview 62, 67

HP technical support 88

I

identification number 77

iLO (Integrated Lights-Out) 51, 62, 63, 64

IML (Integrated Management Log) 62, 64

Insight Diagnostics 65, 72

installation services 24

installation, server options 28, 32 installing hardware 32

installing operating system 30

Integrated Lights-Out (iLO) 62

Integrated Management Log (IML) 64

Intelligent Provisioning 62, 64

J

Japanese notice 80

K

Korean notices 80

L

laser devices 81

LEDs, drive 13

LEDs, front panel 13

LEDs, rear panel 9

LEDs, troubleshooting 74

M

memory 44, 45

memory options 32, 44

memory subsystem architecture 46

Mini-SAS cable 35

N

NMI header 12

non-hot-plug drives, installing 33

O

operating system installation 30

operating systems 30, 73

optical drive 41, 59

optimum environment 24

Option ROM Configuration for Arrays (ORCA) 62,

70

options installation 24, 28, 32, 38

ORCA (Option ROM Configuration for Arrays) 62,

70

P

passwords 53

PCI riser board expansion slot definitions 11

PCI riser cage 21, 22

PCI riser cage, installing 22

PCI riser cage, removing 21

PDU (power distribution unit) 26

phone numbers 88

power cabling 60

power cord 82

power distribution unit (PDU) 26

Power On button 30

power requirements 26, 87 power supply 87 power supply specifications 87

powering down 17 preparation procedures 17

problem diagnosis 74

R

rack installation 24 rack resources 24

rack warnings 27

RBSU (ROM-Based Setup Utility) 62, 67, 68, 69

rear panel buttons 9

rear panel components 8

rear panel LEDs 9

Index 102

recommended ambient operating temperature

(TMRA) 25

recovery key 53

redundant ROM 71

registering the server 31

regulatory compliance notices 77, 79

removing server from rack 18

required information 88

requirements, electrical grounding 26

requirements, environmental 24

requirements, power 26, 87

requirements, site 25 requirements, temperature 25

retaining the recovery key/password 53

ROM redundancy 71

ROM-Based Setup Utility (RBSU) 53, 67

ROMPaq utility 62, 71

S

safety considerations 72

scripted installation 66 scripting toolkit 62, 66

security bezel 32

security bezel, removing 19

serial number 69

series number 77

server features and options 32

Server mode 62

shipping carton contents 28

site requirements 25

Smart Update Manager 62, 67

specifications, environmental 85 specifications, server 85

SPP 67

static electricity 84

storage controller 35

support 88

supported operating systems 73

system battery 75

system board components 10

system board LEDs 12

system components 7

system maintenance switch 11

T

T-10/T-15 Torx screwdriver 16

Taiwan battery recycling notice 82

technical support 88 telephone numbers 88

temperature requirements 25

TMRA (recommended ambient operating

temperature) 25

Torx screwdriver 16

TPM (Trusted Platform Module) 51, 53

TPM connector 10

troubleshooting 74

Trusted Platform Module (TPM) 51, 53

U

uninterruptible power supply (UPS) 26

updating the system ROM 71

UPS (uninterruptible power supply) 26

USB support 71

utilities 62, 69

utilities, deployment 62, 66, 67

V

ventilation 24

Version Control 72

W

warnings 26, 27

website, HP 88

Index 103

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents